Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 LAccepted-AOC N A | L1 | Accepted-AOC Accepted being L1 Bidder | |
| 2 | Rejected-Technical VILL KAZIYAPUR POST SURATGANJ TAHSHEEL RAMNAGAR KAZIYAPUR NEAR JHEEL LUCKNOW UTTAR PRADESH 227115 UDYAM UP 14 0003184 | 227115 | - | Rejected-Technical Rejected being L-3 bidder | |
| 3 | Rejected-Technical WARD NO 15 STATION ROAD SAKTI DISTT JANJGIR CHAMPA C G 495689 | SAKTI | JANJGIR CHAMPA | CHHATTISGARH | 495689 | - | Rejected-Technical Rejected being L-2 bidder |
Tender Value
₹5.6 L
EMD Value
₹6,700
Closing Date
6 Aug 2022, 5:00 pmClosed
SO EnM, SECL Raigarh Area
Office of the General Manager SECL Raigarh Area, ChhoteAtarmuda Raigarh 496001
Providing power supply (3.3 KV /440 V) to Mobile Crusher to be installed at CS10 of Jampali OCM, Raigarh Area.
2022_SECL_251285_1
SECL/GM/RGH/EnM/ e-Tender/22-23/07 dtd 25/07/2022
Open Tender
Electrical and Maintenance Works
Item Rate
10 days
Raigarh Area
Please refer Tender documents.
5 documents required · 5 mandatory
₹6,700
20 Sept 2022
26 Jul 2022
8 Aug 2022
26 Jul 2022
6 Aug 2022
27 Jul 2022
27 Jul 2022 - 30 Jul 2022
Amount
NOTE: Electric poles & conductor will be provided by SECL .
Erection of steel tubular Pole or rail pole structure in cement concrete1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling and secured with holding clamps,bolts,nuts,etc as required. Above 10.00 metre and upto 12.00 metre
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 8 mtrs upto 10 mtrs
Supplying of channel iron 75mm x40mm x 6 mm(7.14 kg per meter) pole top bracket/cross arm for single 11KV over head line conductor complete with 50mm x 6mm M.S flat iron clamps,bolts,nuts and washers including drilling holes for insulator pins,bolts, nuts etc and painting with primer and finish paint as required.
Supplying of channel iron 75mm x40mm x 6 mm(7.14 kg per meter) V shape cross arm for two11KV over head line conductor complete with 50mm x 6mm M.S flat iron clamps,bolts,nuts and washers including drilling holes for insulator pins,bolts, nuts etc and painting with primer and finish paint as required.
Erection of Pole top/straight two wire/V shape two wire,angle iron/channel iron,cross arm on steel tubular/rail/PCC pole for 11/22/33KV as required.
Supplying of two lengths of channel iron 75mm x 40mm x6 mm(7.14 kg per meter)double pole cross arm for three wire 11KV overhead line conductors complete with through bolts and nuts for clamping to the poles, 50mm x 6mm M.S flats welded on one side to the channel iron and with bolts and nutson the other side for tying the cross arms together,including drilling holes for insulator pins,bolts, nuts etc and painting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 11KV/22KV/33KV overhead lines as required
Supplying and erection of 11KV pin insulator complete with large steel head G.I pin, nuts,washers etc. as required.
Supplying and erection of 11KV Disc insulator for 11KV overhead line with galvanised insulator fittings,ball and socket type and complete with galvanised strain clamps,bolts,nuts,washers etc.as required.
Supply and erection of 75 mm x 90 mm shackle insulator with G.I. Bolt ,nuts and straps etc as required .
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required .
supply of angle iron bracket(50x50x6mm),65cm long
Erection of angle iron/channel iron,cross arm on wood/RCC/ steel tubular/rail/PCC pole etc. as required.
Erection of ACSR conductor of 7/2.11 mm to 7/3.00 mm diameter including binding etc. as required. Length= 0.200 km 5 conductor in 40M span= 200*5= 1000m & Length= 0.500 Km*3 conductor in 50 M span = 500*3 = 1500m, Total = 2500m
supply of clamps,nuts& bolts etc for running earth bracket
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.(without watering pipe)
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with lSI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 63A TP&N
Providing and fixing following rating & breaking capacity MCCB with thermomagnetic release and terminal spreaders inside the existing cubical panel board including drilling holes in cubicle panel, making connections, etc. as required. 200A,36KA, 4 pole
Providing and fixing following rating & breaking capacity MCCB with thermomagnetic release and terminal spreaders inside the existing cubical panel board including drilling holes in cubicle panel, making connections, etc. as required. 400A,50KA, 4 pole
Total impact of GST for the purpose of CTC
RAMESH KUMAR SWARNKAR
AJAY KUMAR SINGH
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_259662.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .