| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.6 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹41.7 L+₹2.6 L (6.60%)Rejected-Finance 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹44.8 L+₹5.7 L (14.5%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹45.8 L+₹6.6 L (17.0%)Rejected-Finance 229 CHANDEL MARKET HARJINDER NAGAR KANPUR 208007 | KANPUR | KANPUR | UTTAR PRADESH | 208007 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹51.4 L+₹12.2 L (31.2%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
23 Oct 2024, 6:00 pmClosed
GE(AF) EM Chakeri, Kanpur
GE(AF) EM Chakeri, Kanpur
REPAIR/ MAINTENANCE OF FLAME PROOF LIGHT FITTING, WIRING AND CONNECTED ACCESSORIES ALONG WITH REPAIR/ MAINTENANCE OF HIGH BAY LIGHT FITTING WITH CONNECTED ITEMS AT AFS KANPUR
2024_MES_676551_1
8720/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Area under GE(AF) EM Chakeri Kanpur
As per tender documents
9 documents required · 9 mandatory
₹500
GE (AF) E/M CHAKERI
₹98,000
Yes
22 Jan 2025
25 Sept 2024
28 Oct 2024
26 Sept 2024
23 Oct 2024
9 Oct 2024
Amount
Receiving complaints from Concern Incharge of Internal section (Power House) lodged by user, Taking down highbay fiting (Normal/flameproof) HPSV / HPMV /HPMH/LED fittings,Aviation lights/ Flameproof tube light fittings/ bulkhead flameprrof fittings and Bulding security light fiting HPSV / HPMV /HPMH/LED LIGHT fittings /CFL Lights wattage,scraping out the unwanted materials with help of wet cottan cloth and nylon brush, cleaning reflector of the fittings externally, glass cover, control gear box, hanging assembly and internal surface and rehanging hibhbay light fittings at existing location from roof /wall or any location any capacity from any height any situation, repairs to the extent by removing connections from the system checking of unserviceable spare parts and serviceable parts ,replacement of unserviceable parts with new spares and testing complete, tightening the loose connection and made item functional, reassembling the fitting and re-fixing/ re-hanging the same after repair in existing location or other location (as directed) including replacement of three core proof copper cable of size 1 Sqmm and painting of MS Bracket and clamps with aluminium paint and tesing complete complete all as specified and directed by Engineer-in-Charge.
Note : (i) Spares required for repair (except connection cable) shall be measured and paid separately as supply only items here-in-after and the cost of connection cable shall be deemed to be included in the quoted rates. (ii) Necessary arrangement of Tools and plant required for repairing of highbay light fitting or any light fitting fixed on the hanger (upto roof) and cost of the same are deemed to be including in the quoted rate.
Taking down old unserviceable/deteriorated batten/PVC conduit point wiring from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets, ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1 : 3) or plaster of Peris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash all as required and directed by Engineer-in-Charge.
M & L for concealed point wiring on wall and surface on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.5 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for the following :- For one light, fan.
All as per item No 3 here-in-before but For one socket point controlled by one switch on independent board.
All as per item No 3 here-in-before but For one socket point controlled by one switch on same board.
As per item No 3 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
M & L for surface point wiring on wall and surface on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including casing caping 20 / 25 mm white / ivory with all accessories/ fittings such as junction boxes, bends, tee, elbow etc including PVC / Polycarbonate gang box of appropriate size for fixing of switches / sockets, fan regulators, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing all as specified and directed by Engineer-in-Charge for the following :- For one light, fan, call bell.
All as per item No 7 here-in-before but for one socket point controlled by one switch on independent board.
All as per item No 7 here-in-before but for one socket point controlled by one switch on same board.
All as per item No 7 here-in-before but in casing /caping for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FR insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
M & L for concealed point wiring on wall and surface on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid metallic stove enamelled steel conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.5 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for the following :- For one light, fan, call bell.
All as per item No 11 here-in-before but for one socket point controlled by one switch on independent board.
M & L for concealed point wiring on wall and surface wiring on ceiling / roof /hanger with necessary fixing arrangements with stranded PVC-FRLS insulated and unsheathed copper stranded conductor of size 2.5 Sqmm, 1100 volts grade drawn in and including 16 gauge stove enameled ERW rigid steel conduit (metallic) not less than 19 mm dia with all MS conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including PVC-FRLS insulated and unsheathed copper stranded conductor of size 2.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces for one light, fan point controlled by one switch complete all as specified and directed.
S&F, for switch flush type single pole one way 5 Amps, 240 volts, white finish complete all as specified.
S&F, for switch flush type 15 Amps, 240 Volts single pole white finish complete all as specified.
S&F, for socket outlet 5 pin, 5 Amps flush type white finish complete all as specified.
S&F, for socket outlet 2 in 1, 3 pin, 5/15 A, flush type universal, 240 V white finish complete all as specified.
S&F, electronic socket size, rotary, 5 speed step type regulator, 120-230 V white finish complete all as specified.
S&F, ceiling rose, surface backlite, 65 x 20 mm three terminal, ISI Marked .
M&L sub main wiring with two single core PVC-FR insulated unsheathed stranded copper conductor cable of size 2.5 sqmm drawn in existing/new conduit with 2.5 Sqmm PVC-FR insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring complete Note : (i) Two single core cable and one run of earth copper conductor will be measured and paid as one unit length (ii)Conduit pipe and fitting will be measured and paid separately if applicable.
M&L sub main wiring with two single core PVC-FR insulated unsheathed stranded copper conductor cable of size 4 sqmm drawn in existing/new conduit with 4 Sqmm PVC-FR insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring complete Note : (i) Two single core cable and one run of earth copper conductor will be measured and paid as one unit length (ii)Conduit pipe and fitting will be measured and paid separately if applicable.
M&L sub main wiring with two single core PVC-FR insulated unsheathed stranded copper conductor cable of size 6 sqmm drawn in existing/new conduit with 6 Sqmm PVC-FR insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring complete Note : (i) Two single core cable and one run of earth copper conductor will be measured and paid as one unit length (ii) Conduit pipe and fitting will be measured and paid separately if applicable.
S&F PVC conduit ISI marked of size not less than 20 mm dia concealed position on wall and surface postion on roof/ceiling or trusses inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly incl cutting chasing & making good to disturbed surfaces & matching with the existing colour of wall/floor etc incl taking down old PVC conduit all as directed by Engineer-in-Charge.
S&Fin replacment of rigid stove enameled steel conduit ISI marked of size not less than 20 mm dia concealed position on wall and surface postion on roof/ceiling or trusses inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly incl cutting chasing & making good to disturbed surfaces & matching with the existing colour of wall/floor etc all as directed by Engineer-in-Charge.
Supply and Fixing in replacement of energy saving & environment friendly and robust LED highbay light fitting 200 Watt 230 V AC suitable for ceiling suspended type and equipped with IP 65/66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specifed and directed.
S&F in replacement for LED Building Security Light 70 watt orf alumenium PDC housing glass cover with IP 66 protection complete all as specified and directed by engineer in charge
S&F in replacement for LED Building Security Light 90 watt orf alumenium PDC housing glass cover with IP 66 protection complete all as specified and directed by engineer in charge
M&L in replacement for LED Building Security Light 120 watt orf alumenium PDC housing glass cover with IP 66 protection all as specified and directed complete all as specified and directed by engineer in charge
Supply and fixing in replacement of high pressure die cost aluminium (LM6) alloy housing SMD LED Flood Light 100 watt ,luminaire of not less than 100 Lumens/ watt system lumen with and including mounting accessories specially desiged heat sinks dust free , PMMA material Penuts lenses for effective light distriubtion, co-related color temp upto 5700K, CRI 80 and above, maintenance of lumen @ L70 protection of fixture :- IP65, IK08, Class I, Line Frequancy 50/60 HZ, power factor 0.95 and above, Driver efficiency > 90%, Voltage rang 120-277 Volt AC, lumen standerd / test certificate as per IEC 60598 and IS 10322, fixture should have BIS certification, driver too has BIS certification as mandotary from Govt of India, complete incl taking down old unserviceable fitting all as specified and directed
M& L in replacement of Flood Light LED 120 Watt, 240 Volts complete with ELECTRONIC DRIVER including suitable size of reflector, hanging/ fixing arrangements & connecting with three core copper cable 2.5Sqmm including taking down old worn out high bay luminary complete all as directed by Engr-in-Charge
M& L in replacement of Flood Light LED 160 Watt, 240 Volts complete with ELECTRONIC DRIVER including suitable size of reflector, hanging/ fixing arrangements & connecting with three core copper cable 2.5Sqmm including taking down old worn out high bay luminary complete all as directed by Engr-in-Charge
M& L in replacement of high bay luminary LED 150 Watt, 240 Volts complete with ELECTRONIC DRIVER including suitable size of reflector, hanging/ fixing arrangements & connecting with three core copper cable 2.5Sqmm including taking down old worn out high bay luminary complete all as directed by Engr-in-Charge
M&l for bracket made out of GI pipe 50mm dia medium grade, 0.90 mtr long bent to shape with suitable fixing arrangement with FI nuts, bolts complete including taking down old unserviceable bracket all as directed by Engr-in-charge
S&F, in replacement, double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as directed.
S&F, in replacment of double door metallic sheet metal enclosure Type IP-43 & IK-09 for DB when MCBs to be used SPN 4 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position on wall and suface position on trusses and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as directed.
S&F in replacment of sheet metal enclosure for DB SPN 2 ways, 240 V complete fixed properly on in concealed position on wall and suface position on trusses and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as directed.
All as per item No 36 above but TPNL 4way, Double door 415 volts conforming to IP-42
S&F testing and commissioning of MCB SP 240 volt 6 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs.
All as per item No 38 above, but SPN 16-32 Amps -do-
All as per item No 38 above, but SPN 40-63 Amps -do-
All as per item No 38 above, but TP 40-63 Amps 415 volts -do-,
All as per item No 38 above but TPN 40-63 Amps 415 volts -do-,
S&F sheet metal enclosure TPN MCCB DB 4 Way, 415 volt (vertical type) with bus bar double door type IP 43 -IK 09 for DB when MCBs and MCCB 160 Amp (as incomer) to be used fixed properly on/inconcealed position and to provide required sizes of flexible conduit at any open surface near DBs for cables/wires complete all as specified and directed.
S&F in repair MCCB 125 Amps, 4 Pole, 415V, 16KA complete all as specified and directed.
S&F in repair MCCB 160 Amps, 4 Pole, 415V, 36KA complete all as specified and directed.
Supply and fixing LED driver suitable for highbay light fitting of capacity 100 watt as per fitting/make available at site including taking down and refixing complete all as specified and as directed by Engr-in-Charge .
Supply and fixing LED driver suitable for highbay light fitting of capacity upto 150 - 200 watt as per fitting/make available at site including taking down and refixing complete all as specified and as directed by Engr-in-Charge .
Supply and fixing LED driver suitable for building security light fitting of capacity upto 120 watt as per fitting/make available at site including taking down and refixing complete all as specified and as directed by Engr-in-Charge .
Taking down flame proof HPSV / HPMV /HPMH / LED fittings /Flame proof tube light fittings / bulkhead flameprrof fittings any location any capacity from any height any situation, repairs to the extent by removing connections from the system checking of unserviceable spare parts and serviceable parts, replacement of unserviceable parts with new spares and testing complete, tightening the loose connection and made item functional, reassembling the fitting and re-fixing / re-hanging the same after repair in existing location or other location (as directed) including replacement of three core proof copper cable of size 1 Sqmm and painting of MS Bracket and clamps with painting after cleaning with grey colour and tesing complete all as specified and directed. Note: Fitting other than as taken down vide item no. 1 shall be measured under this items. Spares required for repair (except connection cable) shall be measured and paid separately under respective supply only items of BOQ and the cost of connection cable shall be deemed to be included in the quoted rates.
Supply only in replacement Master LED Tube 1200 mm, 20 Watt complete all as specified and directed.
S&F in replacement Flame proof weather proof LED Flood light of capacity 100 watt epoxy finish with LM 6 aluminium housing , heat resistant borosilicate tubular glass held in two aluminium cups with inbuilt DRIVER accessories, including any minor T&P like nut bolt etc and mapower required at site for fitting of new LED light at existing location complete all as specified and directed.
S&F in replacement Flame proof weather proof LED luminaire 2 X16/20W, epoxy finish with LM 6 aluminium housing , heat resistant borosilicate tubular glass held in two aluminium cups with inbuilt DRIVER accessories & LED tube light complete all as specified and directed.
S&F in repair flame proof weather proof switch with cable termination in LM6 aluminium alloy housing 16 Amp, 240 volt complete all as specified and directed.
S&F in repair 60 watt LED flameproof wall glass in die cost alluminium with heat resistant to tonhened glass IP 65 protection for safe working in Gas/Vapour envirment CIMFR certificate desirable) alongwith driver and all other accessories complete all as specified and directed.
S&F in repair LED flood light fitting 45 watt LED Flame proof weather proof well glass luminaire with LM 6 aluminium alloy lamp housing , heat resistant and tuffend glass, hings cover with neroprene gasket, painted MS bar guard, epoxy finish provided with internal flameproof control gear & fixing accesories with suitable driver complete all as specified and directed.
S&F in repair LED Flame proof batten 1x16/20 Watt suitable for safe working in gas/vapour envirment with IP65 protection linked alongwith driver and all other accessories for installation complete all as specified and directed.
S&F in repair flame proof weather proof switch socket & plug combined 16 A, 250 V(2P+Earth) with cable termination in LM 6 aluminium alloy housing complete all as specified and directed.
S&F in repair flameproof weather proof main switch 32A TPN complete with fixing arrangement including taking down old unserviceable complete all as specified and directed.
S&F in replacement die cast aluminium alloy LM-6 Flame proof weather proof flood light fitting LED 120 watt, powder coated epoxy based light grey shade 631 as per IS : 5, 'O' ring endless Neoprene Rubber Gasket, heat resistant type clear toughened glass with two numbses cable entriy complete all as sepcified and directed.
S&F in replacement of ball bearing suitable for Flame Proof Exhaust fan 450 mm suitable complete all as specified and directed.
S&F condenser with PVC clamp of 2.5 mfd complete all as specified and directed.
Disconnecting & Taking down Flame proof Exhaust fan any make any size from any position at site transporating to MES store Yard & dismantling blades opening the stator and rotor of fan and providing new lubricating, grease in bearing/bushes, reassembling, commissioning and testing complete & refixing fan to site including providing nuts, bolts, locking bolts, blades screws, split pin, rubber reel, PVC connector, rubber pad, washers whereas required and refixing in position complete all as specified and directed. Note:- All major rerpair such as replacement of Bush, bearing , condensor, shaft, connection wire, winding & painting will be measured & paid separately under respective Item of BOQ
M&L for removing of burnt winding from Flame Proof Exhaust Fan 450/600 mm fans rewinding the same with equal gauge of super enameled copper winding wire, insulating paper, varnishing and testing complete including transportation to work shop and bringing back to store and testing complete all as specified and directed.
M&L for circular / rectangular framed shutters suitable for FLP 18" Exhaust fan made out of as per existing size and strength for shutter painted with two coat of synthetic enamelled over a coat of red oxide primer complete with neccesarry fixing accessories all as per existing complete all as specified and directed.
All as item No 64 but circular / rectangular framed shutters suitable for FLP 24" Exhaust fan.
S&F in repair flame proof weather proof threaded type junction box LM 6 aluminium alloy 3 way complete including taking down old unserviceable complete all as specified and directed.
All as per item No 66 above but flame proof weather proof threaded type junction box LM 6 aluminium alloy 4 way.
S&F in repair flame proof weather proof metallic hose conduit 3/4 " dia 300mm long including taking down old unserviceable complete all as specified and directed.
All as per item No 68 above but flame proof weather proof metallic hose conduit 3/4 " 500mm long.
S&F in repair flame Proof double compression brass cable gland 3/4" dia complete with nipples including taking down old unserviceable complete all as specified and directed.
S&F in repair LED aviation obstruction light fitting, red painted die-cast aluminium alloy housing , red coloured polycarbonate dome and accessores complete comprising of LED 300 TWIN complete all as specified and directed.
S&F in repair LED aviation obstruction light fitting, red painted die-cast aluminium alloy housing , red coloured polycarbonate dome and accessores complete comprising of LED 300 SINGLE complete all as specified and directed.
Material and Labour for high bay light wiring on celling /roof / trusses with necessary fixing arrangement for 3 core PVC insulated sheathed armoured stranded copper conductor cable of size 2.5 sqmm 1100 volt grade and PVC insulated 3 way brass connector of 6 amps to be provided for each high bay fittings including necessary fixing arrangement of cable with MS strip not less than 20x2.5 mm with suitable nut bolt and washer duly painted with aluminium paint over red oxide primer by maintaining distance not more than one meter. Note:- (i) The cost of PVC insulated brass connector 3 way with 2 mm thick ms enclosed box for each fitting shall be inclusive in quoted rate (iii) The cost of ms plate shall be inclusive in quoted rate
santosh electronics (BID ID -3140657)
M/s Sohanil Construction (BID ID -3147948)
A.B.Enterprises (BID ID -3147538)
PAWAN COOL CORPORATION (BID ID -3136891)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .