COL PALLAWA JHA CWE
HQ CWE MAMUN PIN 145001
PROVN OF 02 x 500 KVA TROLLEY MOUNTED 11 KV DISTR TRANSFORMER AND 01x125 KVA TROLLEY MOUNTED DG SET AT MAMUN MIL STN
2026_MES_799587_1
CWE/M-46/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
MAMUN
as per tender documents
9 documents required · 9 mandatory
₹500
Yes
GE SOUTH MAMUN
₹87,400
Yes
20 Nov 2026
20 Nov 2026
18 Dec 2026
20 Nov 2026
11 Dec 2026
4 Dec 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation, Testing, Commissioning of Oil Cooled, Copper wound, Step down "BIS marked & BEE star labelled" transformer of capacity 500 KVA plinth mounted outdoor type with latest feature complete with standard fitted HT 11 KV 3 phase, LT 433 V 3, phase 4 wire, 50 C/S oil immerse, naturally cooled externally cooling tube delta connection on primary HT 11 KV side and star connection on secondary LT 433V with tapping at ±2.5% to ±5 % & ± 7.5 % on HV side and to be changed by means of hand operated off load tap changing gear including first filling of new transformer oil of dilectric strength not less than 55 KV with all fitting and accessories such as LT box with cable gland, HT box with cable gland, Silica gel, breather, Oil level indicator gauge, drain out valve (oil tank), exhaust vent, air release valve, temp gauge, cast iron wheel etc comply with EEL 2 IS 1180 2014 (Level III) with latest amendment 1,2,3 & 4 having total losses @50% load 1430W & total losses @100% load 4100W. Following items/ Accessories included in this rate, therefore No any extra cost will be paid for this items complete all as specified and directed by Engineer-in-charge.
(i) Name, rating & diagram plate
(ii) Off circuit tap changing switch
(iii) Earthling terminals
(iv) Lifting lugs
(v) Oil drain valve with plug
(vi) Oil filter valve with plug
(vii) Conservator with oil filling hole
(viii) Thermometer pocket
(ix) Air release plug,
(x) Silica gel breather,
(xi) Removable inspection opening
(xii) Explosion vent | 2 | Each Job | - | - |
| 2 | Supply and laying in trenches or fixed to wall/pole or passing through pipe or road crossing, testing and commissioning of HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty ) with aluminium conductor, 11KV (Earthed) grade, suitable for earthed system, with aluminium conductor of size 120 Sqmm 3 Core complete all specified and directed. | 72 | RM | - | - |
| 3 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm including testing complete all as specified and all as directed. | 4 | Each | - | - |
| 4 | M & L for LT UG cable 300 sqmm x 3.5 core, 1100 Volts grade XLPE insulated, armoured, heavy duty with aluminium conductor laid in trenches or fixed to walls/ poles or passing through pipes with and including, cable gland lugs/ thimbles/ ferrules including connecting, testing complete all as specified and as directed. | 56 | RM | - | - |
| 5 | M & L for LT UG cable 185 sqmm x 3.5 core, 1100 Volts grade XLPE insulated, armoured, heavy duty with aluminium conductor laid in trenches or fixed to walls/ poles or passing through pipes with and including, cable gland lugs/ thimbles/ ferrules including connecting, testing complete all as specified and as directed. | 57 | RM | - | - |
| 6 | M&L for cable end termination jointing kit , outdoor heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium cable of size 240 Sqmm to 300 Sqmm, 1100 volts complete all as specified and all as directed. | 4 | Each | - | - |
| 7 | M&L for cable end termination jointing kit , outdoor heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium cable of size 150 Sqmm to 185 Sqmm, 1100 volts complete all as specified and all as directed. | 2 | Each | - | - |
| 8 | M&L for trolley for 500 KVA transformer, factory fabricated manufactured of MS Sheet, angle irons, channels etc duly painted as per load class recommended by manufacturer's of transformer with four wheels and one spare wheel, hydraulic jack, toe rod/chain, air filling pump, four wheel drum brake system, spring loaded drawbar, leaf spring based suspension system provision for sliding screw jack 04 Nos for levelling of transformer etc complete all as specified and directed.
Note: Drawing of trolley duly approved from manufacturer of transformer shall be submitted by the contractor. | 2 | Each | - | - |
| 9 | Supply, Installation, Testing and Commissioning of capacity 125 KVA (100 KW) 415 Volt, 0.8 PF, 3 phase, 50 Hz factory assembled Silent Diesel Engine Driven Generating Set with flexible coupling 1500 RPM alongwith sound proof enclosure (accoustic enclosure) designed for reducing the sound level to 75 DB (A) average IS 8528 Part - 10 as per approved CPCB IV+ norms alongwith Retrofitted emission control device and as per GSR 371 (E) and independently supported from engine to outside of power house upto 1.00 mtr, AVM pads foundation as per manufacure's design, battery start with suitable cables for connecting from DG Set to panel board, DG set shall be capable of operating in including of the following accessories suitable for parallel operation/ independent operations:-
(A) Prime Mover:- Diesel Engine of suitable capacity water cooled radiator type closed circuit as per BIS 649 or IS-1002 direct inject type turbo with turbo charger. The DG Set shall be capable of running 24 hrs continously with 10% overloading for one hour in every 12 hrs as per BIS-5514/BIS-649, Engine shall be equipped with all standard fitting as per manufacturers recommendations and mounted on common base frame through flexible coupling with following accessories :-
(i) Battery charging ammeter
(ii) Battery charging voltmeter
(iii) Ignition key and starting with push button switch
(iv) Lubricating oil pressure gauge
(v) Electronic/Microprocessor based Governor controlling
(vii) Toggle switch for idle running.
(viii) Oil Temperature gauge
(ix) Safety control (Trip):-
(a) High water temperature
(b) Low lubricant oil pressure
(c) Over Speed | 1 | Each Job | - | - |
| 9.1 | (x) Lubricant oil heater to avoid freezing
(xi) 24 Hours starting equipment comprising of the following :-
(a) 01 No, 12 Volts, 180 AH Battery.
(b) Battery charging alternator with inbuilt regulator
(c) Self starter motor of suitable capacity
(d) Battery leads (Copper standard cable) of suitable size with brass thimbles and terminals
(B) Alternator:- Alternator of capacity of 125 KVA/100 KW at NTP, 50 Hz, 415 Volt, 1500 RPM, 0.8 PF, running rate @ 1500 RPM, with insulation class 'H' self excited, self regulated, screen protected with self excited field brush rotating fixed designed to be coupled with above engine through flexible couping, the alternator shall be conforming to BIS-2613 or IS-4722.
(C) Control Panel:- Alternator control inbuilt panel cubical type with internal wiring with copper conductor for 125 KVA, 415 volt, 03 Phase, 04 wire, 50 Hz alternator fabricated out 1.6mm thick MS sheet painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, microprocessor based generator set monitoring, metering and control system with LCD display designed to meet the demands of today's engine driven generator sets.
Engine Metering: Oil pressure, Engine temperature, Starting battery voltage, Engine running hours, AC Alternator Metering: L-L Voltage and L-N Voltage, Current (phase and total), kVA (phase and total) and Frequency kwh, Total & per phase (kw & kVA), PF, Utility Voltage and Freq
Engine Protection: Low lube oil pressure, High/Low coolant temperature, Battery High/Low/Weak Volts, Fail to Crank/Start, Sensor failure, Cranking lockout, Low fuel level | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.51 MB
BOQ_897122.xls
BOQ • 1.06 MB
TENDER46.pdf
Tender Documents • 0.97 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .