Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 CrAccepted-AOC BOKOTA NEMUGURI ROAD CITY TOWN SIVASAGAR P O CHARUBHANGA P S NEMUGURI DIST SIVASAGAR PIN 785674 ASSAM | SIVASAGAR | ASSAM | 785674 | ₹2.4 Cr | L1 | Accepted-AOC AOC given |
| 2 | L2₹2.5 Cr+₹18.9 L (8.04%)Rejected-Finance | ₹2.5 Cr+₹18.9 L (8.04%) | L2 | Rejected-Finance Rejected as L2 |
| 3 | L3₹2.6 Cr+₹19.4 L (8.21%)Rejected-Finance | ₹2.6 Cr+₹19.4 L (8.21%) | L3 | Rejected-Finance Rejected as L3 |
| Sl No | Description | Qty | Unit | Ranjan Dutta L2 | M/S BARUAH TRADERS L1 | M/s Mukti Enterprise L3 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. By Mechanical Means (B) RCC | 37.12 | Cum | 1,000 ₹37,125 Lowest | 1,000 ₹37,125 Lowest | 1,000 ₹37,125 Lowest |
| 2.00 | Earthwork in excavation for foundation of structures as per drawings and technical specifications , including setting out, construction of shoring and bracing, including dewatering and using machinery, removal of stumps and other deleterious matter, dressing of sides and bottom and back filling with approved material. I) In Ordinary Soil B. Mechanical means. ii) Depth up to 3.00 m (with dewatering) | 787.41 | Cum | 150 ₹1,18,111.35 | 120 ₹94,489.08 Lowest | 150 ₹1,18,111.35 |
| 3.00 | Bored cast-in-situ M 35 grade RCC pile excluding reinforcement complete as per drawing and Technical Specifications and removal of excavated earth with all lead and lift up to 1000 m.
Pile diameter = 1200 mm | 240 | Metre | 10,500 ₹25,20,000 | 8,600 ₹20,64,000 Lowest | 11,500 ₹27,60,000 |
| 4.00 | Pile load test on single vertical pile in accordance with I.S. 2911 (Part IV)as per technical specifications. a) Initial load test (Safe load = 160 t | 240 | MT | 500 ₹1,20,000 | 500 ₹1,20,000 | 350 ₹84,000 Lowest |
| 5.00 | Pile load test on single vertical pile in accordance with I.S. 2911 (Part IV)as per technical specifications.
b) Routine Load Test of 2x160x2.50
2 Nos. test for piles upto 50 Nos. | 400 | MT | 450 ₹1,80,000 | 300 ₹1,20,000 Lowest | 350 ₹1,40,000 |
| 6.00 | Pile integrity test of piles by using pile driving analyser or equivalent as approved by the E-IN-C and detail specification . Test to be carried out by an approved reputed agency including all incidental works. | 8 | each | 15,000 ₹1,20,000 | 10,000 ₹80,000 | 4,500 ₹36,000 Lowest |
| 7.00 | Cement concrete for reinforcement concrete in pile cap complete as per drawing and technical specifications.
D. RCC grade M - 35
i) Using concrete mixer | 155.14 | Cum | 10,000 ₹15,51,420 | 8,000 ₹12,41,136 Lowest | 8,000 ₹12,41,136 Lowest |
| 8.00 | Levelling course for Pile cap Providing and lying of PCC M - 15 levelling course 100 mm thick below the pile cap. as per drawing and technical specifications. | 9.17 | Cum | 6,500 ₹59,598.5 | 6,000 ₹55,014 Lowest | 8,000 ₹73,352 |
| 9.00 | Supplying, fitting and placing uncoated TMT Bar reinforcement in foundation complete as per drawing and Technical Specifications. (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent) | 50.05 | MT | 75,000 ₹37,53,750 Lowest | 80,000 ₹40,04,000 | 76,000 ₹38,03,800 |
| 10.00 | Plain/ Reinforced Cement Concrete in substructure complete as per Drawing and Technical Specifications. (N) Without plasticiser
H) a) RCC Grade M 35
a) Height up to 5.0 m
Case-I : Using Concrete Mixer | 112.9 | Cum | 10,000 ₹11,29,040 | 9,000 ₹10,16,136 | 8,000 ₹9,03,232 Lowest |
Tender Value
₹2.4 Cr
EMD Value
₹4.9 L
Closing Date
26 Mar 2026, 2:00 pmClosed
Chief Engineer, EAP, PWRD
O/o the Chief Engineer, EAP, PWRD, Assam, Fatasil
Construction of Bridge in Dibrugarh District i) Br. No.15/1 of Mahmora Ali Road
2026_PWRDW_51947_5
eCF No 720769/15
Open Tender
Civil Works - Bridges
Item Rate
720 days
Dibrugarh District
Please refer to Tender documents
7 documents required · 7 mandatory
₹5,000
₹4.9 L
Yes
O/o the Chief Engineer, EAP, PWRD, Assam, Fatasil
24 Aug 2026
13 Mar 2026
26 Mar 2026
13 Mar 2026
26 Mar 2026
13 Mar 2026
13 Mar 2026 - 19 Mar 2026
19 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. By Mechanical Means (B) RCC | - | Cum | 100 | - |
| 2 | Earthwork in excavation for foundation of structures as per drawings and technical specifications , including setting out, construction of shoring and bracing, including dewatering and using machinery, removal of stumps and other deleterious matter, dressing of sides and bottom and back filling with approved material. I) In Ordinary Soil B. Mechanical means. ii) Depth up to 3.00 m (with dewatering) | 0.6 | Cum | 100 | ₹59.9 |
| 3 | Bored cast-in-situ M 35 grade RCC pile excluding reinforcement complete as per drawing and Technical Specifications and removal of excavated earth with all lead and lift up to 1000 m.
Pile diameter = 1200 mm | - | Metre | 10 | - |
| 4 | Pile load test on single vertical pile in accordance with I.S. 2911 (Part IV)as per technical specifications. a) Initial load test (Safe load = 160 t | - | MT | 10 | - |
| 5 | Pile load test on single vertical pile in accordance with I.S. 2911 (Part IV)as per technical specifications.
b) Routine Load Test of 2x160x2.50
2 Nos. test for piles upto 50 Nos. | - | MT | 10 | - |
| 6 | Pile integrity test of piles by using pile driving analyser or equivalent as approved by the E-IN-C and detail specification . Test to be carried out by an approved reputed agency including all incidental works. | - | each | 10 | - |
| 7 | Cement concrete for reinforcement concrete in pile cap complete as per drawing and technical specifications.
D. RCC grade M - 35
i) Using concrete mixer | 0.8 | Cum | 10 | ₹7.99 |
| 8 | Levelling course for Pile cap Providing and lying of PCC M - 15 levelling course 100 mm thick below the pile cap. as per drawing and technical specifications. | - | Cum | - | - |
| 9 | Supplying, fitting and placing uncoated TMT Bar reinforcement in foundation complete as per drawing and Technical Specifications. (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent) | 1 | MT | - | - |
| 10 | Plain/ Reinforced Cement Concrete in substructure complete as per Drawing and Technical Specifications. (N) Without plasticiser
H) a) RCC Grade M 35
a) Height up to 5.0 m
Case-I : Using Concrete Mixer | 0.6 | Cum | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.23 MB
SBDDib_21.pdf
Tender Documents • 1.78 MB
BOQ_82350.xls
BOQ • 0.31 MB
ESMP.pdf
Additional Documents • 1.86 MB
Drawing.pdf
Additional Documents • 6.19 MB
LOT.pdf
Additional Documents • 0.16 MB
LOF.pdf
Additional Documents • 0.24 MB
Annexure-X.pdf
Additional Documents • 0.14 MB
Technical_Specification.pdf
Additional Documents • 2.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .