| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.6 LAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹15.6 L+₹4,656.88 (0.30%)Rejected-Finance 1170 BENGALI MOHALLA NEAR PRABHAKAR HOSPITAL AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹16.8 L+₹1.3 L (8.07%)Rejected-Finance ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹18.0 L+₹2.4 L (15.4%)Rejected-Finance | L4 | Rejected-Finance Not lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
2 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF AMBALA
HQ CWE (AF) AMBALA AMBALA CANTT-133001
REPAIR / MAINTENANCE OF HT INFRASTRUCTURE IN DOMESTIC AND TECHNICAL AREA AT AF STATION BARNALA UNDER GE (AF) HALWARA
2021_MES_497737_1
CWE/AF AMB/HAL-39/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
HALWARA
For enlisted in MES Class E and category b ii and for unenlisted refer NIT
7 documents required · 7 mandatory
₹500
GE AF HALWARA
₹40,000
Yes
3 Mar 2022
28 Dec 2021
4 Feb 2022
28 Dec 2021
2 Feb 2022
19 Jan 2022
28 Dec 2021 - 8 Jan 2022
60 days
Amount
Supply, laying, jointing, testing and commissioning HT XLPE cable (heavy duty), 11000 volts (earthed), cross sectional area 120 Sqmm, 3 core, insulated, screened, sound compacted aluminium conductor, screening with extruded semi conducting layers, insulation screening with copper tape covers laid up with PVC (ST-2), extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked with IS-7098 Part II with amendment, laid in trenches /pipes /ducts /along poles/ walls/ equipment etc including taking out/down of old unserviceable HT cable from existing site complete all as specified and directed.
Description all as per BOQ item No. 1.00 here-in-above but cross sectional area 150 Sqmm. Notes for item No. 1.00 & 2.00:- (i) Cable shall be of manufacturing date not earlier than Jun 2021. All the cable shall be embossed with year of manufacturing, meterage at every metre, in addition to its own standard markings as per IS i.e. Size, voltage etc. (ii) Excavation & earth work, sand cushioning, protection pipes, end termination joints & protection covers shall be measured and paid separately. (iii) No straight through joint shall be permitted in less than single drum length. (iv) The contractor shall produce original purchase vouchers duly machine numbered alongwith excise duty gate pass of factory for verification and record. (v) Cable shall be tested in the presence of rep of Accepting Officer at the factory premises and by the GE or rep of GE after laying in the trenches & before returning filling in the trenches.
Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5mtr in depth for foundation etc or for walls, shafts, manholes not exceeding 10 sqm on plan or for laying pipes/cables etc and getting out, in soft/loose soil complete all as specified & directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick each in soft/loose soil complete all as specified and directed.
Removal of excavated soil to a distance not exceeding 50 mtr & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L Sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cm deep after laying the cable (punned down to 18 cm depth after laying and stretching of cable ) complete all as specified and directed.
M&L in replacement un-reinforced precast concrete cable cover , Class HV type-1, flat, size 300mmx180mmx40mm, laid flat for protection of cable , adjacent to each other, perpendicular to central axis of cable complete all as specified and directed.
S&F in replacement cable route indicator, showing 'MES HT UG Cable" and arrow mark painted with two coat synthetic enamel paint over & including one coat of zinc oxide primer, made out of 80mm dia, 6mm thick Cast iron plate fixed on MS flat of size 40mm x 6mm, 600mm long, including cutting, chasing, drilling, welding etc.(whichever required) and embedded in PCC block 1:3:6, type C-2 of size 20cm x 20cm x 30cm in the ground including excavation and earth work complete all as specified and directed.
Disconnecting of HT cable & control wiring connections from existing bus bar and disconneting trolly including servicing of complete parts of RMU 3 way, cleaning with carbon tetra chloride, lubrication of mechanical parts, adjustment and calibration of complete relays etc including checking parts, repairs to control wiring with single core copper conductor of existing size as required at site for RMU 3 way, of any type, any make for satisfactory running including replacement of defective spare parts/items and applying one coat of 11 KV insulation paint on bus bar, spouts and other connected parts/items, re-assembling the same, re-connecting all HT & AC/ DC connections to make it functional including tesing on existing load complete all as specified and directed.
Description all as per BOQ item No. 9.00 here-in-above but RMU 2 way.
Description all as per BOQ item No. 9.00 here-in-above but RMU 6 way. Notes for srl No 9.00 to 11.00: (i) Spare parts shall be measured and paid separately. (ii) Parts replaced shall be identical to those specified by original manufacturer. (iii) Parts of minor nature such as nuts, bolts, screws & washers required at site are deemed to be included in quoted rates. (iv) Servicing of complete parts shall be carried out through OEM/authorized rep of OEM. (v) A Board of Officers shall be appointed by the Accepting Officer for ascertaining the repair work required in RMU.
S&F in replacement self powered protection relay of RMU of make & specifications as existing at site complete all as specified and directed
S&F in replacement resin cast ring core protection Current Transformer of ratio 14.4/0.075Amp, Class 10P80, VA 0.1 or suitable for relay type W1C1, 50 C/S of RMU of make & specifications as existing at site complete all as specified and directed
S&F in replacement resin cast ring core metering current transformer of ratio 80/1Amp, Class 1.0, VA-2.5, 50C/S of RMU of make & specifications as existing at site complete all as specified and directed
S&F in replacement digital multifunction meter for 11 KV RMU of make & specifications as existing at site complete all as specified and directed.
S&F in replacement shunt tripping coil of RMU of make & specifications as existing at site complete all as specified and directed
S&F in replacement set consisting of 3 HV-Back up fuse link for three phase indoor type conforming to IEC 60282-1 suitable for fixing in 11 KV RMUs (for load upto 250 KVA) of current rating (capacity) 10Amp having short circuit rating not less than 63 KA complete all as specified and directed.
S&F in replacement set consisting of 3 HV- fuse link for three phases indoor type OCB for load upto 200 KVA transformer having shrot circuit rating not less than 63 KA complete all as specified and directed.
Servicing of HT panel, detection of defective components, replacement of worn out parts and servicing/cleaning of mechanical components after drewout of VCB trolly and testing for smooth operation manual/remote after calibration of relay through OEM of VCB/Test wing of UPPCl and resetting & generation of testing report by the primary injection set for 11KV VCB for OC/FE, parameter of relay setting for healthy system, complete all as specified and directed. Note :- (i) Replacement of wornout minor parts shall deemed to be included in quoted rate. Major parts shall be measured and paid separately. Testing and calibration shall be done from OEM or their Authorised representative. (ii) A Board of Officers shall be appointed by the Accepting Officer for ascertaining the repair work.
S&F in replacement Spring charging Motor of VCB 110-230Volt AC supply for the opening and closing of contacts, make & specifications as existing at site complete all as specified and directed.
S&F indicator lamp as per existing colour code for 11 KV VCB of make & specifications as exist at site complete all as specified and directed.
S&F in replacement digital multifunctional meter 96x96mm, range 0-300-150 Amp Model type 3 phase 4W EN 8400 class 1.0, auxilary supply 110 volt with RS 485 port complete all as specified and directed.
S&F Voltmeter ranging from 0-12 KV, digital type, 96mm x 96mm class 0.5, PTR 11000/rt3/110/rt3 complete all as specified and directed.
S&F in replacement cable jointing kit for 11000 volt earthed grade, indoor type, end termination heat shrinkable type joints with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 sqmm to 185sqmm complete all as specified and directed.
Description all as per BOQ item No. 26.00 here-in-above but size 240 sqmm.
S&F in replacement cable jointing kit for 11000 volt earthed grade, outdoor type, end termination heat shrinkable type joints with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 sqmm to 185sqmm complete all as specified and directed.
S&F in replacement cable jointing kit for 11000 volt earthed grade, straight through, end termination heat shrinkable type joints with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sqmm to 185sqmm complete all as specified and directed.
Description all as per BOQ item No. 29.00 here-in-above but size 240sqmm.
S&F in replacement Galvanised iron strip 25mm x 4mm with porcelain saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
Supply, installation, testing & commissioning of 11KV HT, CPRI approved, factory made feeder pillars box, outdoor type, made out of 2.15mm thick MS CRCA sheet, size not less than 165cm x 80cm x 117cm with top cover projection all around, weather proof, vermin proof, double door, powder coated, handle with locking arrangement, PVC insulated copper bus bar strip 3 Nos of size 130cm in length, 5cm in width and 5mm in thickness mounted on HT 11KV insulator 9 Nos.(three Nos per Bus bar), insulator should be mounted on MS sheet with thickness 3mm made in shape duly painted with weather proof resistive paint, the feeder pillar box should be mounted on MS frame made with MS angle of size 60mm x 60mm x 6mm and grouted on ground in PCC 1:3:6 type C-1 using 20 mm graded mechanically crushed stone aggregate including taking down/out old bus bar chamber complete all as specified and directed. Note: The earthwork complete & PCC work included in quoted rates.
Supply and installation Air break switch, gang operated, triple pole, 11000 volt, 400amp rating, outdoor type for horizontal or vertical operation, mechanically operated, mounted on insulators and steel frame with operating mechanism & operating rod of 25mm bore, heavy grade GI pipe from ground level with locking arrangements including making electrical connections to make it functional after testing including dismantling/taking down/out old unservieable air break gang operated switch from two/four pole structure complete all as specified and directed.
S&F in replacement lightning arresters gap less metal oxide type consisting of zinc oxide varistors, FRP core and silicon housing with all fittings transmission class discharge capacity 65 kilo amp 11000 volts complete all as specified and directed.
Supply only of tinned copper dropout fuse wire 15 amp, solid conductor of size 28 SWG complete all as specified and directed.
Supply only of self adhesive electrical insulation tape 7mtr long, 1.8cm wide & 0.125mm thick, ISI marked, colour as approved complete all as specified and directed.
M&L spreading of stone aggregate of nominal size not more than 40mm from the bay/yard manually without damaging any equipments, cable or parts of the Grid bays, spreading & levelling of finished gravel uniformaly in layers not exceeding 15 cm thick, watered and rammed to true surface complete all as specified and directed.
S&F cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed duly painted with two coats of aluminium paint over & including one coat of zinc oxide primer including dismantling of old cross arm etc. complete all as specified and directed.
S&F in replacement galvanised mild steel chain link fencing of 3.15mm dia mild steel wire, mesh size of 75mm x 75mm complete all as specified and directed.
S&F mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 including dismantling of old MS framed work complete all as specified & directed
M&L providing precast reinforced cement concrete type B-l, 1:2:4 (20 mm graded aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area exceeding 100sqcm but not exceeding 400sqcm, with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and fixed complete all as specified and as directed. Note : The quoted rates include for use of formwork (straight or curved).
Tracing out fault in 11 KV under ground cable with the help of fault tracing machine and rectifying the same with joints to restore the supply complete all as specified & directed. Note : (i) Cable Joint kit shall be measured and paid separately. (ii) Necessary earth work is included in quoted rates. (iii) All other necessary arrangements suitale for locating the faults is deemd to be included in the quoted rates (iv) T&P required for the entire job shall be provided by the contractor at his own end and nothing extra shall be admissible on this account.
Disconnecting HT/LT cables & Earthing connections of burnt /defective transformer of capacity upto 250KVA, 11KV/433 volts, 3 phase, any make/type, from pole/floor mounted, taking down from site of installation carefuly with the help of cranes and transporting the same to workshop for repair, opening, draining out transformer oil, dismantling complete & taking out core assembly & removing burntout windings, cleaning /washing of tank removing the dirt sludge and sticky materials from all parts of the transformer including core tank and cooling tubes, removal of damaged parts, dehydrating the core assembly, re-assembling after replacement of damaged parts of the transformer after repairs, making connections and filling dehydradated/fresh transformer oil and testing for all type of tests(routine test & full load test) including transportation back & reinstallation/connection of transformer at site complete all as specified and directed. Notes:- (i) Spare parts & new copper winding shall be measured and paid seperately. All parts/components replaced shall be identical to those specified by original manufacturer. (ii) The labour factor of dismantling/taking out of old spare parts & copper winding are included in quoted rates. (iii) The draining of old transformer oil is deemed to included in quoted rates but filling new transformer oil and dehydration & refilling of old transformer oil shall be measured & paid separately. (iv) A Board of Officers shall be appointed by the Accepting Officer for ascertaining the repair work required in transformer and all inventory shall be prepared in presence of Engineer-in-charge & Contractor. (v) The transformer shall be repaired at authorized dealer workshop as approved by GE and the cost of this aspect is deemed to be included in quoted rates.
M&L winding of transformer any capacity at HT/LT side with super enamelled copper wire of gauge & weight as exists, varnishing & drying by vaccum impregnating, provinding insulating material, fixing the coil in the position in core assembly and making connection as per original pattern including testing as per latest IS/BIS complete all as specified & directed. Notes: (i) Winding of transformer should be connected with tap changer after completion of winding work. (ii) Transformer shall be tested in front of rep of GE & test results shall be submitted to Engineer-in-charge. (iii) The quantity of winding shall be assesed by BOO.
S&F 11KV HT porcelain bushing, outdoor/indoor type for the transformer capacity upto 250 KVA complete all as specified and directed. Note: Transformer bushing model/make shall be compitable with existing model/make transformer.
S&F 1100 volt LT porcelain bushing, outdoor/indoor type for the transformer capacity upto 250 KVA complete all as specified and directed. Note: Transformer bushing model/make shall be compitable with existing model/make transformer.
S&F brass stud with accessories suitable for HT 11KV grade insulator with con & rubber washer, double Brass nuts & brass washer at both end of stud for transformer upto capacity 160 KVA to 250 KVA complete all as specified and directed.
S&F brass stud with accessories suitable for LT 1100 volt grade insulator with con & rubber washer, double Brass nuts & brass washer at both end of stud for transformer upto capacity 160 KVA to 250 KVA complete all as specified and directed.
S&F adhesive computerised cut sticker on 2mm thick aluminium sheet, blue back ground with white letter, sticker size 60cm X 90cm, letter size as suitable for display on substation wall for complete transformers rating and other details of all transformers installed inside substation complete all as specified and directed. Note : Name plate board shall be fixed to substation bldg wall with suitable fastener bolt.
S&F breather assembly of transparent plastic body with top and bottom portion pressed with metalic cover, filled with silica gel blue in colour and suitable for pipe entry of 15/20/25mm dia as per the site requirement, complete all as specified and directed.
Dehydration/centrifuging & filling of transformer oil by means Ultra High Vaccum double stage machine to remove impurities from oil such as moisture, dirt, air and other gases at site of installation in running condition of transformer including testing the oil before and after centrifuging from top and bottom of transformer to achieve the BDV value 40KV(rms) & above at 2.5mm air gap complete all as specified and directed. Note:- (i) Oil Test value record register shall be prepared in presence of AGE/JE and handed over the register to sub divn on completion of work. (ii) The contractor is required to submit the di-electric repot after dehydration and filtration of each transformer before claiming payment.
Supply & filling transformer oil of dielectric strength not less than 50 BDV to comply IS-335 of 1993 complete all as specified and directed. Note:- (i) Empty container shall become Govt property & shall be taken on charge throrugh receipt voucher. (ii) Oil Test value record register shall be prepared in presence of AGE/JE and handed over the register to sub divn on completion of work. (ii) The contractor is required to submit the di-electric repot of each transformer before claiming payment.
M&L in replacement earthing complete with galvanized steel earth plate electrode 60cm X 60cm X 6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of earth plate not less than 1.5 mtr below ground level, connected to GI earth lead strip 32 mm x 6 mm upto 7.5 mtr long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly & watering pipe light grade GI 20 mm bore including protection pipe GI light grade 40mm bore , wire mesh, funnel,lugs, salt, charcoal dust, excavation & earthwork in soft/losse soil and refilling pit chamber with PCC 1:2:4 type B1 using 20 mm graded mechnically crushed stone aggregates , RCC 1:2:4 type B-1 using 20 mm graded mechnically crushed stone aggregates pit cover slab 50 mm thick reinforced with 8 mm dia TMT bars @ 15 cm c/c both ways including necessary form work all as shown in electrical plate No 3 of SSR part-I, including testing on completion at site complete all as specified and directed. Notes:- (i) Any variation in length of earth lead and protection pipe of earth lead shall be adjusted through DO. (ii) On testing if the desired earth resistance is not obtained, earthing will be generated at No extra cost , till the desired earth resistance is obtained. (iii) The chamber shall be constructed atleast 1.5 mtr away from the earth electrode.
M&L for cleaning of entire substation building any size/area/height inside, wall, ceiling, floor and outside wall, plinth protection with suitable brush/broom & wiper, removing wild vegetation around substation building complete all as specified and directed. Notes:- (i) Each substation building cleaning complete shall be measured as one unit.
For Credit Schedule refer tender documents. The amount of credit schedule shall be deducted in total quoted amount of BOQ to arrive contract sum.
The Rahul Vig
NARINDER KUMAR SONS
JASSI TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .