| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹9.3 L+₹20,178.10 (2.23%)Rejected-Finance | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹9.3 L+₹28,029.30 (3.10%)Rejected-Finance | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹9.5 L+₹43,118.70 (4.76%)Rejected-Finance E 140 2010 BKP VILL AMTALLA PO DUMARCHIR DIST PAKUR PIN 814111 JHARKHAND | PAKUR | PAKUR | JHARKHAND | 814111 | L4 | Rejected-Finance HIGH RATE | |
| 5 | L5₹9.6 L+₹55,787.85 (6.16%)Rejected-Finance HATIA ROAD DANGALPARA DISTT DUMKA JHARKHAND PIN 814101 | DUMKA | DUMKA | JHARKHAND | 814101 | L5 | Rejected-Finance HIGH RATE |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
26 Jan 2024, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Tapan Das AE(civil)
AGE I AF Singarsi
Repair replacement of PVC GI pipe line PVC water tank alongwith fitting of MD accn area at AF Station Singarsi under AGE I AF Singarsi
2024_MES_636128_1
C/8636/E8
Open Tender
Civil Works
Item Rate
180 days
AGE I AF Singarsi
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
AGE I AF Singarsi
₹18,000
Yes
16 Feb 2024
6 Jan 2024
27 Jan 2024
6 Jan 2024
26 Jan 2024
19 Jan 2024
Amount
Cutting holes into stone walls n. exc. 150 Sq cm built in cement mortar or cement lime mortar and walls of cement concrete,complete all as specified and as directed.
Cutting existing 20mm steel tubing for alterations or additions, complete all as specified and as directed
Taking up or down steel tubing 15mm bore and connections, including cleaning for refixing or removal to storeyard, complete all as specified and as directed.
Taking up or down steel tubing 20mm bore and connections, including cleaning for refixing or removal to storeyard, complete all as specified and as directed.
Supplying and laying of CPVC 20mm outer dia pipes of SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors, complete all as specified and as directed.
Supplying and laying of CPVC 25mm outer dia pipes of SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors,complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in roofs, floors other than ground floors beams staircases, landing, chajjas and similar suspended work, complete all as specified and as directed by Engineer-in-Charge.
M&L for cement concrete type B-0, 1:2:4 (12.5 mm Graded stone aggregate) as in roof padding , chajja repairs, complete all as specified and as directed by Engineer-in-Charge.
M&L for Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortal (1.4) with water proof compound for external brick surface finished even & smooth,complete all as specified and as directed.. Note:- WPC will be measured and paid separately.
M&L for Cleaning the roof surfaces and applying bitumen primer @ 0.30 kg/sqm, providing and laying 3mm thick APP modified water proofing membrane weighing not less than 3.00 kg/sqm reinforced with non woven polyester mat weighing not less than 160 gm/sqm, having softening point not less than 800 N /Sq cm, tearing strength of 180N, with minimum of 10 cm side laps and 15cm end laps, laying by application of torch, and applying industrial bitumen 85/25 @ 1.2 kg/sqm on top surface, complete all as specified and as directed by Engineer-in-Charge.
Supply only water proofing compound.
Dismantling water tanks of capacity exc 250 liters but n exc 500 Liters and removing from site to store, complete all as specified and directed by Engr-in-charge.
S & F Rotational moulded polyethylene water storage tanks with triple layered white colour with ISI marked (Make : Sintex) including plastic lid cover, (cylindrical vertical with closed top) hoisted and fixed in position of capacity 1000 ltrs including making connecrtion, 20mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed . (Minimum weight 210gms) complete all as specified in SSR Part I, complete all as specified and directed by Engr-in-charge.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position,complete all as specified and as directed.
Dotto as above except water tank but fixing only including re-fixing in position cleaing and re-connecting compete all as specified and directed by Engr-in-charge. (Cleaning repairing, etc. measured separately)
S&F CPVC Ball valve (gate valve) quarter turned screwed bothe eng for CPVC pipe or for union of 25mm dia bore and fixed all complete all as specified and as directed by engr in chargewheel head, screwed both ends for iron pipe and fixed.
S&F in repair 15mm bore dia Bib taps chromium plated, cast copper alloy with capstan handle, screwed down, screwed for iron pipe or for brass ferrule and complete all as specified and as directed by Engr-in-charge.
S&F 15mm bore dia Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, complete all as specified and as directed by Engr-in-charge
S&F for 15mm bore angle Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed,complete all as specified and as directed.
Demolition of Brickwork or stone/boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and as directed by Engr-in-charge
M&L for Brick work with fly ash bricks straight or curved on plan n. exc. 6m mean radious built in CM 1:6 etc, complete all as specified and directed.
Taking down cement or cement plaster of any description on brick or stone walls or from concrete surfaces including raking out joints, hacking for key, scrubbing down with water, etc and removing unserviceable material outside cantt area complete all as specified and as directed by Engr-in-charge.
M&L for Rendering 10 mm thick in CM 1:6 on fare faces of brick surface finished even and smooth without using extra cement etc all as specified (icluding necessay scafolding lifting arrangement for external surfaces), complete all as specified and as directed by Engr-in-charge.
M&L for Rendering 10 mm thick on fair faces of concrete surface of ceiling, finished in cement mortal (1:3) with even & smooth surface without using extra cement,complete all as specified and as directed by Engr-in-charge.
M&L for applying two coats of cement base paint incl preparation of new plastered surface, complete all as specified and as directed.
M&L for applying three coat of white washing on ceiling including prepration of new plastered surface of walls, complete all as specified and as directed.
M&L for GI pipe 80 "medium grade " ISI marked with and including all fittings ie bend , Tee, elbow , union ect and fixed complete to walls and ceilings or laid in floors/trenches, making good the disturbed surface as earlier, including taking out old U/S GI pipe, complete all as specified and as directed by Engr-in-Charge.
M&L for GI pipe 50 "medium grade " ISI marked with and including all fittings ie bend , Tee, elbow , union ect and fixed complete to walls and ceilings or laid in floors/trenches, making good the disturbed surface as earlier, including taking out old U/S GI pipe, complete all as specified and as directed by Engr-in-Charge.
M&L for GI pipe 40 "medium grade " ISI marked with and including all fittings ie bend , Tee, elbow , union ect and fixed complete to walls and ceilings or laid in floors/trenches, making good the disturbed surface as earlier, including taking out old U/S GI pipe, complete all as specified and as directed by Engr-in-Charge.
M&L for GI pipe 20 "medium grade " ISI marked with and including all fittings ie bend , Tee, elbow , union ect and fixed complete to walls and ceilings or laid in floors/trenches, making good the disturbed surface as earlier, including taking out old U/S GI pipe, complete all as specified and as directed by Engr-in-Charge.
M&L for cast iron sluice valve of 100 mm dia ISI Marked, confIrming to IS14846 both ends flanged with brass spindle, class PN1.6 and necessary new MS nuts, bolts, washer and gasket, including taking out old u/s ones for credit and making good etc, complete all as specified and directed by Engr-in-Charge.
S&F in repair gun metal gate valvesof size 50 mm with iron wheel head, screwed both end for iron pipe following bore of pipes, complete all as specified and as directed Make -Laxmi,Ramco.
S&F in repair gun metal gate valvesof size 40 mm with iron wheel head, screwed both end for iron pipe following bore of pipes complete all as specified and as directed. Make -Laxmi,Ramco.
S&F in repair gun metal gate valvesof size 20mm with iron wheel head, screwed both end for iron pipe following bore of pipes, complete all as specified and as directed. Make -Laxmi,Ramco.
DANATION CONSTRUCTIONS
M/S Subhadip Enterprise
M/S MBS TRADING CO
M/S KUMAR AVINASH
M/S New Builders Corporation
M/S SINGH ENTERPRISE
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .