Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹74.2 LAccepted-AOC OLD NO 79 1 NEW NO 14 KAPPAL POLU STREET OLD WASHERMENPET CHENNAI 21 | CHENNAI | TAMIL NADU | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹80.5 L+₹5.9 L (7.89%)Rejected-AOC NO 36 KALAIVANAR STREET BHARATHI NAGAR MINJUR 601 203 | MINJUR | THIRUVALLUR | TAMIL NADU | 601203 | L2 | Rejected-AOC L2 bidder |
Tender Value
Refer Docs
EMD Value
₹77,600
Closing Date
27 Jul 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer/ MTS and GTS
Chief Engineer/ MTS and GTS
Carrying out the maintenance works in Fire and Safety sub division and monitoring and recording of parameters in Operation sub division at Basin Bridge GTPS, for a period of one year from the date of commencement of works during 2023-24
2023_EB_347841_1
SE/GTS/OT-23/2023-24
Open Tender
Miscellaneous Works
Item Rate
365 days
Chennai
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹77,600
Yes
2 Sept 2023
21 Jul 2023
28 Jul 2023
21 Jul 2023
27 Jul 2023
21 Jul 2023
Amount
FIRE & SAFETY SUB DIVISION WORKS:
Centralized A/c plant pump Gland leak tightness, Checking belt tension in compressor, detection of gas leak, water make up in the cooling tower tray, clearing any choking in sprinklers, AHUs, etc.
Removal of Filters, cleaning & fixing in AHU's /FUPH Pump filters cleaning /AHU chiller coil cleaning
A/C plant condenser cleaning works / Oil seal/ Head gasket replacement / AHU duct filter/ Diffuser cleaning.
Fire protection System Gland tightness in leaky valves and Pumps, clearing the chocked drain lines, checking the levels of lube oil, fuel, radiator water, etc.
Works involved Fire protection system testing (actuating the MVWS, HVWS, FOAM systems and normalized by balancing of all misbalanced valves and keep the system ready)/system Header draining and pressurizing works for attending emergency nature works
15 Nos. of 45 kg CO2 cylinder weighing and checking in unit 3/ unit 4 /set of 24 nos. of 4.5 Kg CO2 & one no of 9 Kg CO2 fire extinguishers weight, hose clearing
8 Nos. of 45 kg CO2 cylinder weighing and checking in unit 1/unit 2
Set of 3 nos. of 22.5 kg CO2 fire extinguishers weight & hose Clearing/Checking and cleaning of pressurized fire Extinguisher/Checking & Cleaning of CO2 flooding system in unit 1/unit 2
All Fire hose boxes cleaning and hose within a box drying work/Valve chambers cleaning.
Set of 4 nos. of 10 kg DCP/ set of 6 nos. of 2 kg DCP/set of 4 nos. of mech foam portable fire extinguishers weighing, powder /liquid checking works/ Checking & Cleaning of CO2 flooding system in unit 3/unit 4
Set of 5 nos. of 5 kg DCP/set of 2 nos. of mech foam 50 litre capacity fire extinguishers weighing, powder / liquid checking works
One no. of 75 kg DCP fire extinguishers weight, powder sieving, hose clearing
Diesel engine Fuel filling in DG set / FWPH diesel engines
Cleaning of Spray Nozzle in one transformer /weighing & Servicing of 8 nos. 45 Kg CO2 cylinder with puncturing devices in unit 3/unit 4/ CO2 dampers checking and oiling of one unit.
Fuel handling system Pumps & valves gland tightness, removal of weeds in Tank farm area, Clearing roof, etc.
HSD Fuel Tanker unloading / Centrifuge Tray Cleaning
Rectification works / Bowl cleaning works in one no. FUPH Centrifuge
Cleaning of any one of the area Equipments (FUPH / FWPH / A/C plant/ Fuel tank area/DG set) /Cleaning of all portable fire extinguishers / Lubrication of all pumps/Lubrication of all Valves & Hydrants / Cooling tower & sprinkler cleaning 1 no. / FUPH trench and pit
Rectification works in any Pump/ Valve/Deluge Valve FPS, FHS and A/C plant system
Gland/Gland bolts/Gland packing replacement in FPS, FHS, A/C plant valve and pumps system
Window A/c / spilt A/c / package unit coils cleaning works
Rectification works in Window A/C / spilt A/C such as Electrical wiring /capacitors & relay replacement works, etc.
Painting works in FPS, FHS & A/C plant system
Welding works involving gas / arc / cold cutting in pipes, structures and platform
Miscellaneous works in FPS, FHS and A/C plant system
Rectification works in any Valves/pumps/pipeline gasket provision or Valve replacing/removing/ Pump coupling & decoupling/ coupling bush replacement/Pump alignment, Compressor/AHU belt removal & provision/ Lube oil/ filter replacement in compressor / R22 transferring from one compressor to another compressor of A/C plant in FPS, FHS and A/C plant system
Diesel Engine Fuel/lube oil filters/ lube oil/ Fuel hose replacement /Air lock release in FWPH engine per No. / R22 gas refilling in A/c plant compressor/ Lifting of materials
Foam testing for 2 nos. of Diesel tank
Clearing of chocking in MVWS Nozzles in cable gallery
Clearing of chocking in MVWS Nozzles in each Diesel tank
Pump breakdown/Overhauling works in FPS, FHS and A/C plant system
Leak testing of A/C plant compressor system By N2 gas
Window/spilt A/C R22 gas filling works including R22 gas
Window / spilt A/C Body Repair Works/ fan motor repair works
Emergency break down works in any one of FPS, FHS and centralized A/c system
OPERATION SUB DIVISION WORKS:
(i) Monitoring (checking for any abnormalities and leakages, if any) and recording of parameters in the Fuel Forwarding Pump House, MCC Room, Generator, Auxiliary, Turbine, Reduction gear Compartments and recording of DC voltage of all the four Unit Batteries and (ii) Monitoring and recording of parameters in the Fire Water Pump House and maintaining of raw water and fire water reservoir levels.
To Assist the Chemist in Dosing of chemicals for Chlorination, Dechlorination and Antiscaling, during Regeneration of beds (SAC,SBA & MB),during back washing, Rinsing of beds (PSF & ACF) and during handling of chemicals for Regeneration process and to assist the chemist to prepare indicators, Titrant and washing of glass vessels during testing of Raw water and cooling water samples from Units 1 to 4, testing Lube oil samples collected from Units 1 to 4 to test acidity, viscosity and Specific gravity, testing Naphtha and HSD samples during the Receipt of tankers
Assisting the Stores Custodian in arranging and keeping the materials in the respective racks, in periodical verification of the materials in monthly basis to compare the actual stock and ledger stock and assisting the Stores Custodian in receiving the materials at stores and issuing the materials and in weighment of scrap items received through devolution by field and other office works as directed by Stores Custodian
Monitoring and recording of parameters in the 110KV switchyard, Switchyard Control Room, Batteries & Battery chargers of Station, BHEL & Carrier Communication and D.G. set when in service and assisting in Opening & closing of the 110 KV isolators during feeder tripping / normalization and Recording of parameters in all the four units at the Central Control Room, assisting in carrying out isolation / restoration operations in issuing Line Clear and checking the oil levels in GTG, before starting of the units
Checking the oil levels in Generator Transformers, Station Transformers and in the AC plant & service air compressors, Recording of parameters in the AC Plant & Service Air compressors and Recording of readings in 11KV HT Room and 415 V LT room, etc.
RAMYA ELECTRICAL WORKS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .