Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.8 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder. | |
| 2 | L2₹46.0 L+₹8.0 L (21.1%)Rejected-Finance | L2 | Rejected-Finance Not Lowest. | |
| 3 | L3₹50.3 L+₹12.3 L (32.3%)Rejected-Finance | L3 | Rejected-Finance Not Lowest. |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
3 Aug 2022, 6:00 pmClosed
GE Kamptee
Garrison Engineer, Kamptee Cantt - 441 001
REPAIR / REPLACEMENT TO ROOF SHEETS, FALSE CEILING, ROLLING SHUTTERS, SLIDING DOORS, PLASTERING WORKS IN AREA-I UNDER GE KAMPTEE
2022_MES_524699_2
8399/E8
Open Tender
Civil Works
Item Rate
180 days
Kamptee
Class D, Cat a (i)
7 documents required · 7 mandatory
₹500
Yes
GE Kamptee
₹70,000
Yes
28 Sept 2022
28 Jun 2022
5 Aug 2022
28 Jun 2022
3 Aug 2022
6 Jul 2022
Amount
Taking down cement plaster, any description on brick or stone walls including raking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on brick or concrete surfaces even & fair smooth, using water proofing liquid compound and without using extra cement complete all as specified and directed. Note: water proofing liquid will be measured and paid separately.
M&L for rendering 10mm thick in CM 1:6 on brick or concrete surfaces finished fair & even complete all as specified and directed.
Supply only liquid integral water proofing admixture of make pidilite or its equivalent complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint on walls complete all as specified and directed.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of Birla white care putty complete all as specified and directed.
Dismantling of ceiling boards (fibre, pulp, insulation etc) or insulation boards/ blankets any thickness, including cover fillets/ GI SNAP GRID/ POP ceiling etc complete all as specified and directed.
S&F 5mm thick colour/ printed designer PVC wall/ ceiling sheet instips and channel feathered at the edges for fixing on solid PVC wall/ ceiling lining insulated PVC wall/ ceiling lining and solid PVC partition inclusive of solvent cement and fixing arrangements (such as frame work etc and suitable fillet, H-joint, U-end, J-edge, External corner and internal corner, horizontally, vertically or at any height and angle) at site, complete all as specified and directed. Note:- PVC wall/ ceiling lining should be reversible, waterproof, washable, rib-reinforced, rigid, standard metal.
M&L for POP board false ceiling 12/12.5mm thick to flat surface over fixed including with necessary framing work, galvanised grid work, GI suspenders of 6mm thick and joints of ceiling board shall be finished with textile tape etc complete all as specified and directed.
M&L for POP curved surface/corners mouldings 150mm girth with screw on walls etc complete all as specified and directed.
M&L for preparing POP false ceiling and applying two coat of Luster paint over a coat of primer as per recommended by manufacture etc complete all as specified and directed.
M&L for 10 to 12mm thick toughened tinted/plain glass fixed to door or as partition or any other location including with brackets, supports, handles, lock, bottom machine and other accessories as required design complete all as specified and directed.
M&L for non-asbestos designer fibre cement building boards of size 595x595x4mm fixed or laid/inserted to GI frame work with screws/clips as in ceiling laid flat or sloping complete all as specified and directed. Note : GI frame work will be measured and paid for separately. Make : Everest Oceanic Brand
M&L for non-asbestos designer fibre cement building boards of size 595x595x6mm fixed or laid/inserted to GI frame work with screws/clips as in ceiling laid flat or sloping complete all as specified and directed. Note : GI frame work will be measured and paid for separately. Make : Everest Oceanic Brand
S&F GI framework for seamless ceiling of size 600mm x 600mm comprising of hot deep galvanized powder coated perimeter angle 0.43mm thick of size 24x24mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre, main runner Tee section 0.4mm thick with height 38mm and cross approx 1200mm centre to centre with GI cleat and steel expansion fasteners, including drilling holes for 4-6mm dia GI wire suspender and clips etc complete as per manufacturer's recommendations complete all as specified and directed. Notes:- (i) Ceiling boards shall be measured separately. (ii) The grid system shall be as per specification of make as specified and directed.
Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 10 sqm on plan and not exc 1.5m in depth and getting out soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material not exc. 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for and disposal of rubbish outside of MD land complete all as specified and directed.
M&L for cement concrete type B-2, 1:2:4 as in foundation, filling and mass concrete (Using 40mm graded stone aggregate) complete all as specified and directed.
Demolition of brickwork built in cement mortar or cement lime mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L for brick work with fly ash bricks old size, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 complete all as specified and directed.
Taking down door / window frame with shutter (without taking off shutter from the frame) area not exc 1.5 sqm complete all as specified and directed.
Taking down door / window frame with shutter (without taking off shutter from the frame) area exc 1.50 sqm but not exc 4 sqm complete all as specified and directed.
M&L for providing and fixing powder coated aluminium (minimum thickness of powder coating 50 micron) frame work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
M&L for providing and fixing powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Charge.
S&F brass mortise lock (4 levers), vertical type, size 100mm long including all fitting arrangements complete all as specified and directed.
S&F heavy duty double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel complete all as specified and directed.
S&F for sheet glass 5.50mm thick tinted quality and glazing exc 0.50 sqm in each panel complete all as specified and directed.
Dismantling timber scantling 40 Sqcm and over in section in any position unframed work complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F structural rolled mild steel as in roof trusses (framed), purlins crane gantries, rail and fastenings and heavy brackets framing (beam, tee, angle, channel or flat section) including distance pieces, cleats etc complete and similar work conforming to Fe 410-O or Fe 310-O complete all as specified and directed.
S&F framed work as in doors or gates of angle or other section with gusset plates, rails braces, etc. complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering running rails and guides) hanging; also fastening and fixing complete Fe 410 -W(Gde-E- 250) quality A complete all as specified and directed.
S&F mild steel in wind ties for roof including securing bolts, angle iron post and struts etc including cutting tops to shape as directed, drilling hole, notching for wire etc, flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe 410-O or Fe 310-O complete all as specified and directed.
Dismantling asbestos cement (corrugated, semi corrugated etc) sheet in roof covering complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed.
M&L for cutting chases, pinning in, making good to facings where required and cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps,cills, sunshades, shelves, lintels, etc.;and cutting chases for concealed cills, sunshades, shelves, lintels, etc. water tubing or concealed conduit wiring, etc. and making good, cutting exc 20cm girth complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPa as in weather boarding/eaves board in approved design/ pattern/shape to match with existing adjacent water boarding/eaves boards inclusive, as in ridges, hips, valley gutters, drip and straight and fixed with self tapping screw/nut bolt/normal GI screw/nail et as per site requirement and for entire completion of work at any height/ position complete all as specified and directed.
S&F for 6mm thick asbestos cement sheets, corrugated or semi corrugated fixed with ‘L’ or ‘J’ type hook and washers as in roof covering etc complete all as specified and directed.
All as per item No.40 above but except sheets and providing & fixing with new ‘L’ or ‘J’ type hook and washers complete all as specified and directed.
S&F mininimum 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed.
S&F expanded metal, (weight not exc 4 kg per square metre) cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified and as directed.
S&F steel work in tubular trusses / post including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS1161-1979 grade St.-240 complete all as specified and directed.
M&L for PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in roof kerbs or mud stops rounded or chamfered on edges, coping complete all as specified and directed.
M&L for preparation new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and as directed .
M&L for preparation of old steel surfaces of any description over 10cm width or girth & applying two coats of synthetic enamel paint complete all as specified and directed.
Disconnecting existing tanks of capacity exc 250 & not exc 500 Ltrs, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and re-fixing in position including cleaning and removing all the scale and dirt, etc from tank and from mouths of circulating pipes etc complete all as specified and directed.
All as per item No 48 above but capacity of tank exc 500 & not exc 1000 Ltrs complete all as specified and directed.
All as per item No 48 above but capacity of tank exc 1000 & not exc 2000 Ltrs complete all as specified and directed.
S&F GI tubing 15mm bore medium grade with all fittings and fixed to wall with clamps including taking up or down existing GI tubing complete all as specified and as directed.
S&F GI tubing 20mm bore medium grade with all fittings and fixed to wall with clamps including taking up or down existing GI tubing complete all as specified and as directed.
Taking down and refixing of shutter, area not exceeding 1 Sqm each of any height complete all as specified and directed. Note : Refixing including taking down, easing and adjusting and also refixing builders hardware as required including removal of unserviceable screws etc.
All as per item No 53 above but area exceeding 1 Sqm not exc 2 Sqm each complete all as specified and directed.
All as per item No 53 above but area exceeding 2 Sqm each complete all as specified and directed.
S&F in repair steel rolling shutters (1mm thick laths), without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated complete push pull or manual type complete all as specified and directed.
All as per item No 56 above but gear operated type with bevel gear box and crank handle complete all as specified and directed.
S&F safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed.
S&F ball bearing for rolling shutters complete all as specified and directed.
M&L for oiling, greasing and easing of fastener bolts, worn out parts etc in rolling shutters complete all as specified of any size complete all as specified and directed.
S&F in repairs PVC(SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to wall with necessary clamps complete all as specified and directed.
S&F in repairs PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to wall with necessary clamps complete all as specified and directed.
S&F in repair PVC (SWR) Bends any radius for 110mm bore complete all as specified and directed
S&F in repair PVC (SWR) Bends any radius for 75mm bore complete all as specified and directed
S&F in repair PVC (SWR) branch piece single Y equal or unequal for 110mm bore complete all as specified and directed.
S&F in repair PVC (SWR) branch piece single Y equal or unequal for 75mm bore complete all as specified and directed.
S&F PVC water tank cover suitable for existing tank of any size complete all as specified and directed.
M&L for running welding in repairs including cleaning and preparing surfaces for welding thickness of metal to be welded not exc 6mm such as MS butt hinges to MS frame, broken steel windows or ventilator, iron doors and similar work complete all as specified and directed.
Excavating in post holes (or similar holes) each not exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm in hard /dense soil, including with PCC 1:3:6 (using 20mm graded stone aggregate) for embeding angle iron / precast RCC post for fencing /wall complete all as specified and directed.
NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.)[(-) Rs.1,22,750.00]
VIJ ASSOCIATES
Varsha G Nagphase
Bidder Name
M/s Shrangi Rishi Construction
VIJ ASSOCIATES
Varsha G Nagphase
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .