| 1 | L1₹32.5 LAccepted-AOC MATHOSHREE PLOT NO 55 SR NO 787 A BEHIND ASHWANI HOSPITAL GOVIND NAGAR NASIK 422 009 | NASIK | NASHIK | MAHARASHTRA | 422009 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹33.6 L+₹1.0 L (3.07%)Rejected-Finance 47 VED NAGAR COLONY DEORI ROAD AGRA 282 001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹33.6 L+₹1.1 L (3.31%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹35.4 L+₹2.8 L (8.72%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L4 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹82,000
Closing Date
14 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJ VIKAS KUMAR SRIVASTAVA, GE
GARRISON ENGINEER DAMAN TAT RAKSHAK VIHAR DALWADA NANI DAMAN POST DAMAN (UT) PIN 396210
REPLACEMENT OF AC PLANT HT LT EQUIPMENT AGAINST BER AND CONNECTED WORKS AT TECHNICAL AREA OF ICGAS DAMAN
2021_MES_421347_2
8520/E8
Open Tender
Civil Works
Item Rate
180 days
GARRISON ENGINEER DAMAN
PLEASE REFER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER DAMAN
₹82,000
Yes
27 May 2021
13 Mar 2021
16 Apr 2021
13 Mar 2021
14 Apr 2021
31 Mar 2021
60 days
Amount
Supply, Installing, Commissioning & Testing of factory assembled, indoor type, water cooled, Ductable package AC Plant operating on Electric Supply 380/420 Volts, 3 phase, 50 Hz with and including suitable foundation / civil works as per manufacturer's instructions subject to approval of the GE and also comprising of the following components and with the under mentioned features :- (a) Cooling capacity : 5.5 TR / 16632 Kcal/Hr. (b) Refrigerant R407C. (c) Suitable blower. (d) Cooling coil copper tube. (e) Weather/vermin proof steel housing suitably finished/painted for indoor use. (f) Micro Processor based controller with LCD display. (g) Hermetically sealed scroll compressor- 1 No per unit. (h) Air Filter (j) Any other equipments / parts / components / accessories as recommended by the manufacturer and as directed by the GE for entire satisfactory completion of the item. Note :- Package plant 2 x 5.5 TR working at a time and 1 x 5.5 TR at standby. Make : Blue Star/ Voltas/ Daikin/ Carrier as approved by the GE.
Supplying, installing, commissioning and testing of FRP induced draft round / rectangular type counter flow cooling tower of capcity 13 TR supported over hot dip galvanised steel structure, fitted with axial flow fan, direct driven, operated with 3 phase, 415 Volts, AC supply with suitable starters, overload protection and single phase preventors , PVC/Polypropylene fills/ Nozzels with maximum allowable temperature 50 degree centigrade, drift losses 0.005% of water circulation with and including suitable foundation as per manufacturer's instructions & as approved by the GE and float valve of suitable size complete all as specified. Make: Mihir/Adavce/Paharpur /Delta as approved by the GE.
Supplying, installing, commissioning and testing of Energy Efficient series Monoblock centrifugal pump set for condenser cooling water circulation, three phase, 50 cycle, 415V, AC supply with and including suitable starters, overload protection and single phase preventors and also including suitable foundation as per manufacturer's instructions & as approved by the GE, neoprene rubber antivibration ribbed pads complete all as specified, 415 volts, 50 Hz, 3 HP,discharge , 5.5 LPS at 18 metre head, Make: Kirloskar/Best & Crompton(Beacon)/ Groundfoss as approved by the GE.
Supply and Laying MS 'C' class pipes, Heavy grade, 65mm bore with and including all fittings, laid in floors or fixed to walls or ceilings etc, complete all as specified and directed.
Supply and Laying MS 'C' class pipes, Heavy grade, 80mm bore with and including all fittings, laid in floors or fixed to walls or ceilings etc, complete all as specified and directed.
Supply and Fixing 65 mm bore waffer type butterfly valve complete with companion flanges, nuts, bolts, gaskets etc. and confirming to PN - 1.6 ratings, all as specified & directed.
Supply and Fixing 80 mm bore waffer type butterfly valve complete with companion flanges, nuts, bolts, gaskets etc. and confirming to PN - 1.6 ratings, all as specified & directed.
Supply and fix Y strainer Cast Iron 80 mm complete with companion flanges, nuts, bolts, gaskets etc and confirming to PN-1.6 ratings, complete all as specified and directed.
Supply and Fixing gun-metal non return valves of size 80mm bore, complete with companion flanges, nuts, bolts, gaskets etc. and conforming to PN-1.6 ratings, complete all as specified and directed.
Supply, assembly and erection of 22 guage GI sheet with TDF flange, rectangular/ square duct made out of 'L' shaped hollow profile, duly factory boxed, including all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc, complete, all as specified.
Supply, install, testing and commissioning aluminium powder coated grills for supply air/ return air, complete all as specified and as directed.
M & L for Strip Heater 1.5 KW x 3, complete all as specified and directed, Make : Girish/Racold/Bajaj/Daspass. Note: The quoted rates shall also be deemed to include the cost of wiring between control contactor to strip heaters with suitable capacity of PVC copper conductor cable including PVC conduit and its accessories etc.
M & L for Volume control damper made out of GI sheet 16 guage with fusible plug, complete all as specified and directed.
M & L for Fire damper made out of GI sheet 16 guage with fusible plug, complete all as specified and directed.
Supply and fixing Nitrile rubber foam acoustic insulation of 19 mm thick and finally covered with and including 24 gauge perforated aluminium sheet for ACOUSTIC lining, complete all as specified and directed.
Supply, erection, testing and commissioning of INSULATION comprising of the following as under: a) Duct thermal insulation with 19mm thick closed cell elstomeric Nitrile Rubber Closed Cell, class O fire rating
Supply and fixing GI pipe 40mm bore, medium grade with and including all fittings for drain water, complete all as specified and directed.
Supply and fixing Thermostats of rating 0 to 25 degree centigrade suitable for 11 TR package unit, complete all as specified and directed.
Supply and Fixing industrial type pressure guages made out of SS 304 material, SS siphon, all as specified and directed.
Supply and fixing dial type Themometer, complete all as specified and directed.
Supply and laying cable tray made of 2 mm thick GI sheet, 150 mm width for laying control cable, complete all as specified and directed.
Supply & fixing, testing PVC Tank, ISI marked, 3 Layered, closed lid, cylindrical shaped having capacity 2000 Litres including provision of brass float valve, sippon scalled gauge drain, over flow and making pipe connections, valves and fittings etc, complete all as specified and directed.
Supplying and laying 3 core, 2.5 sqmm, PVC insulated, armoured & PVC sheathed with stranded copper conductor, heavy duty, LT 1100 volts grade cable, including testing, complete all as specified and directed.
Supplying and laying 3 core, 04 sqmm, PVC insulated, armoured & PVC sheathed with stranded copper conductor, heavy duty, LT 1100 volts grade cable, including testing, complete all as specified and directed.
Supplying and laying 4 core, 10 sqmm, PVC insulated, armoured & PVC sheathed with stranded copper conductor, heavy duty, LT 1100 volts grade cable, including testing, complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600 mm x 600 mmx 6.00mm thick, burried directly in ground/vertically (Earth pit not less than 2.25Mtr deep below ground level) with top edge of the earth plate not less than 1.5 Mtr below normal ground level, connected to galvanised earth strip of size 32 mm x 6mm complete by means of bolts and nuts, check nuts and washers of galvanised iron or steel, protected by providing 40mm bore GI pipe light grade and connected to main feeder pillar board including watering arrangements with 20 mm bore GI pipe medium grade, PCC 1:2:4 type B-1 chamber, funnel, wire mesh, RCC 1:2:4, 50 mm thick cover reinforced with XPM, necessary excavation in any type of soil, returning, filling, removal of surplus spoil, charcoal and salt filling, complete all as shown in electrical plate No 3 of MES Sch part I, connected to earthing test point, all as specified, indicated and testing on completion. Note : Length of 32mm x 6mm earth lead & protection pipe upto 7.5mtr shall be deemed to be included in the quoted rate.
Supply and fix GI Strip 32 x 6 mm fixed on wall, floor and laid in trenches, complete all as specified and directed.
Material and labour for rubber mat of 2 mtr x 1 mtr x 19 mm thick complete all as specified and directed.
Supply electric rubber hand gloves suitable for 11 KV all as specified and directed.
supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz ,indoor type, cubicle, floor mounted, IP- 52 protection class , free standing, dust and vermin proof, air ventilation made out of 2.00 mm thick CRCA sheet and suitable sized angle iron and flat duly powder coated and shall be CPRI approved Factory Fabricated, and as approved by GE.Panel shall have front and rear opening,locking arrangement, cable alleys, bus bar chamber and switch gear compartment ,hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate,aluminium bus bar duly covered with heat shrink sleeves colour coaded duly fixed on DMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length,incoming and outgoing MCCBs shall have extended bus bar links and civil work/PCC foundation as per site requirement and removing of old unserviceable LT panel of any type after disconnecting of existing cables complete all as specified and directed including comprising of following :- (i) MCCB 250 Amps,4P,35 KA,415 volts,50Hz- 2 Nos (ii)MCCB 200Amps,4P,35 KA,415 volts,50Hz- 1 nos (iii)MCCB 100Amps,4P,25 KA,415 volts,50Hz-6 nos (iv) MCCB 63Amps,4P,25 KA,415 volts,50Hz- 3 nos (v)MCCB 32Amps,4P,25 KA,415 volts,50Hz- 2 nos (vi) Digital, voltmeter,Ammeter,with CTs,VSS & ASS-01 set (vii)LED phase indication lamps RYB-01 set (viii) Aluminium bus bar TPN 1400 Amps rating -01 set (ix)ACB 1000 Amps, Microprocessor realease, 4 pole- 01 ( as a incommer ) (x) Change over switch 400 Amps -01 Nos
supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz ,indoor type, cubicle, floor mounted, IP- 52 protection class , free standing, dust and vermin proof, air ventilation made out of 2.00 mm thick CRCA sheet and suitable sized angle iron and flat duly powder coated and shall be CPRI approved Factory Fabricated, and as approved by GE.Panel shall have front and rear opening,locking arrangement, cable alleys, bus bar chamber and switch gear compartment ,hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate,aluminium bus bar duly covered with heat shrink sleeves colour coaded duly fixed on DMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length,incoming and outgoing MCCBs shall have extended bus bar links and civil work/PCC foundation as per site requirement and removing of old unserviceable LT panel of any type after disconnecting of existing cables complete all as specified and directed including comprising of following :- (i)MCCB 200Amps,4P,35 KA,415 volts,50Hz- 2 nos (ii) MCCB 160Amps,4P,35 KA,415 volts,50Hz- 1 nos (iii)MCCB 100Amps,4P,25 KA,415 volts,50Hz- 1 nos (iv)MCCB 63Amps,4P,25 KA,415 volts,50Hz- 1 nos (v) MCCB 32Amps,4P,25 KA,415 volts,50Hz- 1 nos (vi)Digital, voltmeter,Ammeter,with CTs,VSS & ASS-01 set (vii) LED phase indication lamps RYB-01 set (viii) Aluminium bus bar TPN 600 Amps rating -01 set (ix) ACB 400 Amps, Microprocessor realease, 4 pole- 01 (x) Change over switch 400 Amps- 01
Supply and fix cable jointing kit for 11 KV ( Earthed) grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE cable armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed. Make - Raychem/ M- seal/ Denson
Supply and fix cable jointing kit for 11 KV ( Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE cable armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed. Make - Raychem/ M- seal/ Denson
Supply, laying in trenches/ducts/along wall/through pipes etc, testing and commissioning LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 150 sqmm,3.5 core including making cable connections by providing necessary aluminium lugs duly crimped properly and stainless steel glands, nuts, bolts and washers etc complete in all respects, as specified and directed. Note :- (i) Excavation & Earth work, sand cushioning, cable cover and protection pipe shall be measured and paid separately. (ii) The cable shall be in one length unless otherwise directed by the GE. (iii) Make :- Havells/Polycab/KEI/Finolex
Supply, laying in trenches/ducts/along wall/through pipes etc, testing and commissioning LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 95 sqmm,3.5 core including making cable connections by providing necessary aluminium lugs duly crimped properly and stainless steel glands, nuts, bolts and washers etc complete in all respects, as specified and directed. Note :- (i) Excavation & Earth work, sand cushioning, cable cover and protection pipe shall be measured and paid separately. (ii) The cable shall be in one length unless otherwise directed by the GE. (iii) Make :- Havells/Polycab/KEI/Finolex
Supply, laying in trenches/ducts/along wall/through pipes etc, testing and commissioning LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 70 sqmm,3.5 core including making cable connections by providing necessary aluminium lugs duly crimped properly and stainless steel glands, nuts, bolts and washers etc complete in all respects, as specified and directed. Note :- (i) Excavation & Earth work, sand cushioning, cable cover and protection pipe shall be measured and paid separately. (ii) The cable shall be in one length unless otherwise directed by the GE. (iii) Make :- Havells/Polycab/KEI/Finolex
Material and labour in repairs for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6.3 mm thick buried directly in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron strip of size 32 X 6 mm from earth electrode to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate no 3 of SSR Part-I provision of G I Pipe 20mm bore eight grade for protection of GI strip and GI watering pipe of 40 mm bore medium grade,GI funnel with wire mesh,including char-coal, salt packed all around the earth electrode plate in layers,PCC earth pit chamber 1:3:6 type C1,RCC cover 1:2:4 type B1,excavation,earth work in any strata and returning filling, removal of surplus soil and testing for required value, complete all as specified and directed.
Material and labour for GI pipe 50mm dia "light grade" complete with all fittings laid in trenches, road/ culvert crossing, on wall, floors, on roof, on pole, for cable protection and including removing old unserviceable item complete all as specified and directed. Make :- Jindal/ Tata/ BST
Material and labour for GI pip 80 mm dia "light grade " complete with all fittings laid in trenches,road/culvert crossing,on wall, floors,on roof,on pole, for cable protection complete all as specified and directed . Make :- Jindal/Tata/BST
Cutting of existing road, concrete/bituminous surface by using of mechanical method of any type complete all as specified and directed Note:-PCC for making good road surfaces shall be measured and paid separately)
Material and labour for PCC (1:3:6) type C2 using(40 mm graded stone aggregate ) for making good distrubed road surfaces including necessary use and waste of form work complete all as specified and directed
Supply and filling in and spreading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and as directed. Note: Punned thickess i.e 18 cm shall be measured for paymeny purpose.
Supply and laying unreinforced precast factory made concrete cable cover, class LV, Type -I, flat, size 250mm x 150mm x 40mm, complete all as specified and directed.
Excavation in trenches , not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft loose soil complete all as specified and directed.
Returning filling in soil including spreading leveling watering and well rammimg in layer not exceeding 25 cm th each layer ,complete all as specified and directed
Removing excavated soil not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed Schedule of Credit : Nil
neeraj electricals
cooltech engineering services
Shree Ayyappa Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .