Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC 894 NEAR 132 KV POWER HOUSE SINDHARI ROAD BALDEV NAGAR BARMER RAJ 344001 | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹20.4 L+₹93,710.50 (4.81%)Rejected-Finance 205 IIND PHASE INDUSTRIAL AREA BARMER 344001 | BARMER | BARMER | RAJASTHAN | 344001 | L2 | Rejected-Finance Highest | |
| 3 | L3₹22.5 L+₹3.1 L (15.8%)Rejected-Finance 102 VYAS COLONY NEAR AIR FORCE JODHPUR 342011 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342011 | L3 | Rejected-Finance Highest | |
| 4 | L4₹22.7 L+₹3.3 L (16.8%)Rejected-Finance NO 28 KUMHARON KI BASTI DHOONDHA BARMER RAJASTHAN 344035 | BARMER | RAJASTHAN | 344035 | L4 | Rejected-Finance Highest | |
| 5 | L5₹23.9 L+₹4.4 L (22.7%)Rejected-Finance | L5 | Rejected-Finance Highest |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
4 Oct 2024, 6:00 pmClosed
GE ARMY BARMER
MILITARY ENGINEER SERVICES GARRISON ENGINEER (ARMY) POST BOX NO-53, JALIPA MIL STN, BARMER-344 001
REPAIR MAINT OF STREET LIGHTS PERIMETER SECURITY LIGHTS AND OTHER ALLIED WORKS FOR POCKET A AT JASAI MIL STN UNDER GE ARMY BARMER
2024_MES_668692_1
8775/E8
Open Tender
Civil Works
Item Rate
270 days
GE ARMY BARMER
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ARMY BARMER
₹56,000
30 Nov 2024
31 Aug 2024
8 Oct 2024
31 Aug 2024
4 Oct 2024
13 Sept 2024
Amount
Repair and refixing to street/ security lights any type by removing from existing position and refixing after repair including replacement of the following items complete all as specified and directed. (a) Electronic Driver suitable for 25W to 120 Watt LED light fittings (b) Surge Protector not less than 5 KV rating suitable for 25W to 120 Watt LED light fittings. (c) PCB suitable for LED street light fittings 25W to 120 Watt. (d) Solar Street Light fittings 12 to 24 Watt. Note : (i) Items mentioned at (a) to (d) above to be incorporated in the work will be measured and paid seperately under respective item supply only items. (ii) T&P / Vehicle mounted Telescopic Ladder required for carry out the repair work on lights at a height up to 15 meter will be arranged by contractor at their own cost & the cost shall deemed to be inclusive in the quoted rate.
Repair and refixing of High mast lights fitting of any type by removing from existing position and refixing after repair including the replacement of following items complete all as specified and directed. (a) Electronic Driver 100W to 200Watt suitable for LED light fitting of rating. (b) Surge Protector not less than 5 KV rating suitable for 100W to 200Watt LED light fittings. (c) PCB suitable for LED flood light fittings 100W to 200Watt Note : (i) Items mentioned at (a) to (c) above to be incorporated in the work will be measured and paid seperately under respective item supply only items. (ii) T&P / Vehicle mounted Telescopic Ladder required for carry out the repair work on lights at a height up to 15 meter will be arranged by contractor at their own cost & the cost shall deemed to be inclusive in the quoted rate.
Labour only for making unserviceable street/security lights serviceable placed at pole by disconnection / Isolating power supply either from pole junction box or by disconnecting overhead jumpers and carrying out de-carbonization / de-sulphation at connection points with overhead conductor / light fitting / junction box terminal including replacement connection wire all as required and directed. Note : - (a) New cable as required shall be measured and paid separately under respective item. (b) T&P / Vehicle cost shall deemed to be inclusive in the quoted rate.
Dismantling of depriciated cross arms (Clamp, nut bolts )/ channels/ supports etc care fully from site complete all as specified and directed.
Material and labour for steel structure, cross arms bracing supports ,clamps, back plates of any type, section incl. nuts, bolts, washers, welding ,bending cold or hot in any size and shape all directed Including two coats of aluminium paints over a coat of red oxide primer incl preparation of surface complete all as specified and directed.
Restringing/Tightening only of ACSR conductor of any type and size of street / security light feeder including straightening properly on insulators and binding with aluminum taps /binding wire /conductor jumper etc complete of any size complete all as specified and directed. Note : - Single conductor shall be measured for length re-stringing.
Material and Labour for GI tubing 40 mm dia Medium grade in repairs incl. accessories complete all as specified and directed.
Material and Labour for GI tubing 50 mm dia Medium grade in repairs incl. accessories complete all as specified and directed.
Supply and lay in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross - secctional area 10 sq mm 2 core complete with connection, testing complete all as specified and directed.
Supply and lay in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross - secctional area 6 sq mm 2 core complete with connection, testing complete all as specified and directed.
S&F in replacement 2 core 10 Sqmm weather proof, PVC insulated and PVC sheathed multi stranded aluminium conductor cable, flat type 1100 volts as in service connection etc complete all as specified and directed.
S&F in replacement 2 core 6 Sqmm weather proof, PVC insulated and PVC sheathed multi stranded aluminium conductor cable, flat type 1100 volts as in service connection etc complete all as specified and directed.
S&F in replacement Single core 4 Sqmm weather proof, PVC insulated and PVC sheathed multi stranded aluminium conductor cable, flat type 1100 volts as in service connection etc complete all as specified and directed.
Supply only Aluminium conductor cable 1100 volts grade PVC insulated and PVC sheathed wheather proof multistranded of size 02 Core X 4.0 sqmm complete all as specified and directed.
Dismantling of broken U/S existing PCC earthing chamber with cover including galvanised steel strip any size and SWG of any size wire, earthing material, GI earth plate, GI Pipes, funnels etc complete all as specified and directed including removing of PCC from site and rate quoted shall deemed to be inclusive of these elements.
M&L for earthing complete with galvanized steel earth plate electrodes 600mmx600mmx6 mm thick buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanised iron earthing strip 32mm x6mm thick by means of bolt nuts check nuts and washers of galvanized iron or steel complete all as specified & shown in electrical plate No.3 of MES SSR part-I 2009 connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe up to 7.5 mtr length as protection & watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of strata incl PCC pit (1:3:6) type C-1 with RCC cover including charcoal , salt, funnel complete all as specified and directed at site. Note : Rate included for excavation & earth work in any type of strata as shown in electric plate no-3 in SSR Part-I.
M&L for motorized Auguring/driling in road of dia sutable for laying of 40/50 mm dia GI tubing pipe as per site requirement complete all as specified and directed.
Material and labour for Cement concrete (1:4:8) type D -2 using 40 mm graded stone aggregate for foundation of pole /struts/stay assembly etc including demolition of existing PCC & disposed off debris complete all as specified and directed. Note: The cost of demolition and removal of debris deemed to be inclusive in quoted rate.
Material and labour Cement concrete (1:3:6) type C -1 using 20 mm graded stone aggregate for pedestal of poles/copping including necessary form work ,smooth finish of exposed surfaces etc including removal/ disposal of debris ie. broken PCC complete all as specified and directed. Note: The cost of removal / disposal of PCC coping debris deemed to be inclusive in quoted rate.
Excavation in trenches not exceeding 1.5m wide and n.exc. 1.5m in depth for laying of cable and foundation in soft/loose soil complete all as specified and directed.
Returning filling in and well ramming in layers n. exc. 25cm including spreading, leveling and watering complete all as specified and directed.
Removing excavated material (soil/rock) and depositing at a distance not exceeding 50m complete all as specified and directed.
M&L for sand cushioning to U/G cable for cushioning 8cm below the cable and 15cm above cable complete all as specified and directed. Note: Punned thickness shall only be measured for payment purpose.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size 250 mm x 150 mm x 40 mm and abutting each other with gap between adjacent precast concrete cable cover not exceeding 10 mm over underground cables for protection complete all as specified and directed.
Suppling, fixing and testing of energy efficient, pressure die cast aluminium housing with heat resistant toughened glass & IP-66 protection, dust and water resistant, system efficacy of 110lm/W or more, secondary optics, 10KV SPD, LED Warm White/Cool White Flood luminaries 50 watt, suitable for installations on pole/ bldg including taking down unserviceable light fitting complete all as specified and directed. Make : Crompton/Wipro/ Havells.
Dismantling of ACSR conductor of any type and size from existing poles at various location complete all as specified and directed.
Material and labour for ACSR conductor(weasel) rabbit 1100 volt grade straightening properly on insulators and binding with aluminum taps /binding wire /conductor jumper etc complete all as specified and directed.
S&F in replacement of MCB single pole 'C' curve, 230 Volts 10 KA 6 to 32 Amp rating complete all as specified and directed. Make- ABB / Siemens / C&S / Legrand
Supply and fix in replacement of electric contactor three phase, 415 Volts, 50 Hz, upto 50 Amp load capacity suitable for street light timer box complete all as specified and directed. Make- ABB / Siemens /L&T / C&S / BCH
Supply and fix in replacement of electric contactor single phase, 230 Volt, 50 Hz, upto 40 Amps load capacity suitable for street light timer box complete all as specified and directed. Make- ABB / Siemens /L&T / C&S / BCH
Supply only Electronic Driver Input Voltage Range 160V to 260V AC Single Phase 50 Hz and Output Voltage not exceeding 60V DC suitable for 25/30 Watt LED type fitting complete all as specified and directed. Make-Philips/Wipro/Crompton/Havells
All as per srl item no 31 above but suitable for 45 to 50 Watt LED type light fitting.
All as per srl item no 31 above but suitable for 60 to 75 Watt LED type light fitting.
All as per srl item no 31 above but suitable for 90 to 100 Watt LED type light fitting.
All as per srl item no 31 above but suitable for 120 to 150 Watt LED type light fitting.
Supply only PCB of LED street light fittings suitable for 25 to 50 Watt fitting complete all as specified and directed. Make-Philips/Wipro/Crompton/Havells
Supply only PCB of LED street light fittings suitable for 60 to 75 Watt fitting complete all as specified and directed. Make-Philips/Wipro/Crompton/Havells
Supply only PCB of LED street light fittings suitable for 90 to 100 Watt fitting complete all as specified and directed. Make-Philips/Wipro/Crompton/Havells
Supply only PCB of LED street light fittings suitable for 120 to 150 Watt fitting complete all as specified and directed. Make-Philips/Wipro/Crompton/Havells
Supply only surge Protector not less then 5kV suitable for 25/30/45/60/75/90/100/120/150 Watt LED type light fittings complete all as specified and directed. Make : -Philips/Wipro/Crompton/Havells
M & L for preparation of old painted surface painting of tubular pole/rail pole upto 9 mtr long incl cross arm bracing etc. with one coat of aluminium paint incl painting of pole coping with black synthetic enamel paint and writing pole No. complete all as specified and directed. Note:- Zebra painting using yellow and black colour synthetic enamel paint alternatively upto 1.5mtr height from bottom of pole is deemed to be included in the quoted rate.
M & L for disconecting and re conecting of burnt LT XLPE cable to OH conductor on pole/ equipment including removing of faulty part of cable, preparation of cable for connection, suitable AL lugs, nut bolts etc complete all as specified and directed. Note: The cost of earth work for taking out LT cable loop and refiling will deemed to be included in the qoted rate.
Material and Labour for ZEBRA painting of PCC/steel poles 9/11 m long alongwith road upto 1.5 m height from pedestal, with one coat of enamel synthetic paints in 30 cm height using yellow incl painting of pole coping with black colour synthetic enamel paint and writing pole No complete all as specified and directed.
M&L for trimming and pruning of one complete tree up to a safe distance from the over head lines incl cutting branches of size not exceeding 80mm dia complete all directed at site and disposal of branches/bushes to a distance as indicated for purpose of fire wood for cookhouses of Army Units within the Army Unit and clearing the site complete all as specified and directed . NOTE:- 1. The necessary man power, tool & plant, cutting tools and T&P required for cutting/pruning of branches is deemed to incl in the rate quoted for the job. 2. Proper shut down will be taken by the authorised rep only.
Supply and fixing in replacement of burnt / unserviceable timer switch astronomical time watch digital type along with switch for (auto/manual) on and off including MCB as per requirement complete all as specified and directed. Make: Legrand D-21 type or techno commercially equivalent in Schenider/SEIMENS.
Dismantling of Timer Switch Panel Box of any type and size all directed including removing from site complete all as specified and directed.
Supply & Fix Automatic Timer switch suitable for 03 phase 415 Volts 50 Hz with Nature switch-02 EC infra ray sensor with pre dawn switching off timer, ,MCB, power contactor, and glass wool panel , infra ray sensor with pre dawn switching off timer, 4-8hrs, of Maximum load capacity of 4kw per phase. Degree of protection conforms to IP65. Cat No. SWADEEP-02EC12KW3P of Nature Switch or techno commercially equivalent in Legrand/SEIMENS.
Supply and fixing Automatic timer switch suitable for single phase 230 Volts 50 Hz with Nature switch-02 EC, infra ray sensor with pre dawn switching off timer, 4-8hrs ,MCB, power contactor, and glass wool panel of Maximum load capacity of 3kw, Degree of protection conforms to IP65 Cat No. Swadeep- 02 EC3KW1P of Make: Nature Switch or techno commercially equivalent in Legrand/SEIMENS.
Supply and fix in replacement of security light termination box pole junction box of size 250 x 200 x 100 mm, weather proof, along with connector for 3 phases and neutral and one MCB SP - 6 to 32 Amps rating. The Junction Box shall be insulated and made out of Polycarbonate with glass fiber reinforced. The Polycarbonate JB shall be environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid & anti corrosive. Degree of Ingress Protection IP 65, Pole Mounting type for 6/10/16sq.mm x 2/3.5/4.0 Core cable I/C & O/g .including MCB, Cable Glands etc complete all as specified and directed. Make :Sintex/Hensel or techno commercially equivalent.
Supply and fix in replacement of security light termination box pole junction box of size 140 x 140 x 95 mm, weather proof, along with connector for 3 phases and neutral and one MCB SP - 6 to 32 Amps rating. The Junction Box shall be insulated and made out of Polycarbonate with glass fiber reinforced. The Polycarbonate JB shall be environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid & anti corrosive. Degree of Ingress Protection IP 65, Pole Mounting type for 6/10/16sq.mm x 2/3.5/4.0 Core cable I/C & O/g including MCB, Cable Glands etc complete all as specified and directed. Make :Sintex/Hensel or techno commercially equivalent.
M&L in repair/replacement of PVC conduit 20 mm rigid non metallic including of all tee, bends, elbows etc including fixing accessories GI bracket of suitable size with nut bolts etc complete all as specified and directed . Make: Polycab/Havells or techno commercially equivalent.
Supply and fix in replacement of GI pipe Bracket of 40 mm dia light grade pipe bend to shape of approx length 1.5 Mtr incl 2 Nos MS Clamp of flat iron of suitable size complete with nut, bolt, washers MS Clamps of flat iron of suitable size (not less than 25 x 3mm) Including two coats of aluminium paints over a coat of red oxide primer complete all as specified and directed.
Dismantling of insulators any type any size from existing poles complete all as specified and directed.
Supply and fix pin type porcelain insulator, vitreous white brown or green including one galvanised mild steel spindle two GI washer and GI Nuts 100 mm height 65 mm dia for 1100 volts grade complete all as specified and directed.
Supply and fix shackle type porcelain vitreous white insulator 1100 volt grade 75 mm in height and 90 mm dia including galvanised mild steel strap of size 31mm x 3mm,12 mm dia insulators bolts, washers and nuts complete all as specified and directed.
Supply and fixing in replacement of Post Top Lantern Fixture made up of high grade unbreakable polycarbonate material suitable for 20 W LED lamp B22 base including LED lamp 20 watt with holder connecting complete all as specified and directed. Make :-Havells or techno commercially equivalent in Crompton/Philips/Wipro.
Supply and fixing in replacement energy efficient Lithium based Energy Efficient Integrated Solar Street Light of 12Watt, encases with Monocrystalline Solar PV Panel of 44/46Wp , Lithium Battery 11.1/12.8V, 24.6AH with inbuilt BMS, IP 65, High brightness W-LED(160-180lm/watt) lamp with Aluminum reflector for better light distribution , CRI >70, Color Temperature 5700K - 6500K, Microcontroller based charge controller cum driver, automatic dimming function ( first four hours at full brightness & rest of the time at lower light level with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 10C to (+)55C, weight not more than 10-12kg with adjustable MS clamp suitable for pole/wall mounting etc complete all as specified and directed. Protections: Short Circuit, overload, Reverse polarity and battery protections. Make:- Wipro/Crompton/ Havells.
Supply and fixing in replacement energy efficient Lithium based Energy Efficient Integrated Solar Street Light of 15/16Watt, encases with Monocrystalline Solar PV Panel of 30/35Wp , Lithium Battery 11.1/12.8V, 19.8AH with inbuilt BMS, IP 65, High brightness W-LED(160-180lm/watt) lamp with Aluminum reflector for better light distribution , CRI >70, Color Temperature 5700K - 6500K, Microcontroller based charge controller cum driver, automatic dimming function ( first four hours at full brightness & rest of the time at lower light level with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 10C to (+)55C, weight not more than 8-10kg with adjustable MS clamp suitable for pole/wall mounting etc complete all as specified and directed. Protections: Short Circuit, overload, Reverse polarity and battery protections.Make:- Wipro/Crompton/ Havells.
Supply and fix on pole GI pipe Bracket of 50 mm dia light grade pipe bend to shape of circular form with 1 mtr dia. including fixing arrangements at center as well as cirumferanced made out of GI material and 40 mm dia pipe light grade as supports towards center of suitable length all directed and complete with nut, bolt, washers complete all as specified and directed.
Supply of Solar Charge Controller 5Amp with protection circuits for 12 watt to 20 watt Solar Light System: 12V Nominal Capacity: 50Wp Max Regulation: Low Loss, Shunt Type OVD Battery Charging Type: PWM Protections: Short Circuit and Overload at load Reverse polarity of battery and panel Reverse current flow from battery to panel complete all as specified and directed. Make: Axxon/ Crompton/ Havells.
Supply of PIR Motion Sensor 170uA for 12 to 24Watt Solar Light Standard Detection 5m Lens Color : White Conditions Concerning target 1. The temperature difference between the target and the surroundings should be superior to 4 deg C 2. Movement speed : 1.0m/s 3. Target concept is human body. Make: Axxon/ Crompton/ Havells.
Supply of Lithium Battery 11.1V/ 28.6Ah with BMS Circuit and other necessary wires and connectors suitable for Integrated Solar Lights complete all as specified and directed. Make: Axxon/ Crompton/ Havells.
Supply of Lithium Battery 11.1V/ 19.8 Ah with BMS Circuit and other necessary wires and connectors suitable for Integrated Solar Lights complete all as specified and directed. Make: Axxon/ Crompton/ Havells.
Material and labour in replacement for prestressed cement concrete poles 9 M long of size 102 mm x 172 mm at top and 102 mm x 279 mm at bottom class-10, conforming to relavent latest IS including dismantling and refixing of cross arm, security light fittings, brackets or any other existing fittings etc connecting, testing including dismantling and removal of broken pole and coping complete all as specified and directed . NOTE:- (i) Demolition and disposal of old PCC foundation is included in the quoted rate. Provn of new PCC foundation will be measured and paid separately under relevant item. Painting of pole with two coats of synthetic enamel paint over a coat of primer in yellow and black alternate strips 30 cm wide 5 Nos is deemed inclusive in quoted rate. (ii) Removal of dismantled items from site are included in rate quoted by the contractor.
Supply and fix in replacement ,connecting and testing of LED flood light 120W with with innovative thermal management and in multiple optics and equipped with IP66 protection, ideal for stadium lighting and Highmast applications fixed on pole including taking down unserviceable light fitting complete all as specified and directed. Make : CG Cat Part No. LFLN-120-CDL/60 or Techno commercially equivalent model of make Havells/Philips/Bajaj/Wipro
Supply and fix in replacement,connecting and testing of energy efficient, pressure die cast housing with heat resistant toughened glass and individual high power LEDs with secondary optics and IP-66 protection of street light luminaries 45 watt , impact resistance, fixed on pole including taking down unserviceable light fitting complete all as specified and directed . Make : CG Cat Part No.LSTS-45-CDL-M or techno commercially equivalent model of make Bajaj/Philips/Havells/Wipro
M&L for maintenance and servicing of DG sets (monthly Inspection), of the following capacities including alternator, electric panel board connection to DG set for routine check (A check) of DG set for smooth functioning and carrying out maintanance as directed as specified for the following DG sets :- (a) 380 KVA Capacity-01 Nos (b) 250 KVA Capacity - 01 No (c) 125 KVA Capacity - 01 No (d) 100 KVA Capacity - 06 No (e) 82.5 KVA Capacity - 01 No (f) 62.5 KVA Capacity - 03No (g) 40 KVA Capacity - 01 No (h) 30 KVA Capacity - 02 No (j) 25KVA capacity:-02 No (k) 20KVA Capacity:-02 No
Note: (i) Checking engine oil level and topping up as and when required . Oil shall be measures and paid separately (ii) Checking and adjusting the belts for tension and replacement of belts. Note : Belt shall be measured and paid seperately (iii) Checking of air filter element all type. (iv) Checking of exhaust system for any leakage. (v) Draining of sediment/water from fuel filter and fuel tank. (vi) Cleaning of air cleaner element all type. (vii) Checking engine alternator coupling, mounting bolts and alignment. (viii) Tightening of all nuts and bolts in altenator terminal block. (ix) Checking of alternator carbon brush and connections in alternator. (x) Checking and tightening of all connection in DC control wiring. (xi) Checking of all radiator rubber hose, pipe clips and replacement if required. (xii) Checking and recording oil pressure, water and oil temperarute. (xiii) Checking anti vibration mounting and replacement if required. (xiv) Checking throttle linkage. (xv) Checking battery for cell test, electrolyte level, gravity and topping up to required level (xvi) Routine check / repair work of panel, switch, MCCB, main switch, all contactors, engine control unit. Replacement of Door hinges, locks etc also deemed to be inclusive in quoted rates. (xvii) Checking of AMF panel, all electrical connections etc. (xviii) Checking of earthing resistance. (xix) Cleaning of vegitation around the DG set up to 1.5 mtr area. (xx) Contractor shall employ skilled labour (FGM) for the above repairs and one company engineer/ technician for over all repairs once every in month.
M&L for Inspection, maintenance and servicing of DG Sets of following Capacities including alternator, electric panel board connection to DG set for routine check (B - Check) of DG set for smooth functioning and carrying out maintanance complete all as directed and specified. Note: (i) B-Check once in six month OR 250 Hrs running of DG set whichever is earlier. (ii) B- Check of all DG sets ones shall be paid as one Job (iii) All spare parts required shall be measured and paid separately as supply only (a) 380 KVA Capacity-01 Nos (b) 250 KVA Capacity - 01 No (c) 125 KVA Capacity - 01 No (d) 100 KVA Capacity - 06 No (e) 82.5 KVA Capacity - 01 No (f) 62.5 KVA Capacity - 03No (g) 40 KVA Capacity - 01 No (h) 30 KVA Capacity - 02 No (j) 25KVA capacity:-02 No (k) 20KVA Capacity:-02 No
Note: (i) Repeat the activities of A Check including replacement of lubricating oil. (ii) Replacing lubricant oil filter element with 'O' ring (iii) Replacing fuel filter element (primary and secondary) (iv) Replacing coolant (For Radiator) (v) Replacing Governer oil. (vi) Coolent, Lubricant oil shall be measured and paid seperately under relevant items (vii) Contractor shall employ skilled labour (FGM) for the above repairs and one company engineer/technician for over all repairs (viii) Replacing water body assembly. (ix) Replacing water separater. (x) Cleaning of Radiator with chemicals and replacement of radiator filter . (xi) Replacement of by pass filter. (xii) Checking of all radiator rubber hose and replacement if required. (xiii) Checking and recording oil pressure, water and oil temperarute (xiv) Checking anti vibration mounting and replacement if required. (xv) Checking throttle linkage (xvi) Checking battery for cell test, electrolyte level, gravity and topping up to required level (xvii) Routine check / repair work of panel, switch, MCCB, main switch, all contactors, engine control unit. Replacement of Door hinges, locks etc also deemed to be inclusive in quoted rates. (xviii) Checking of AMF panel, all electrical connections etc. (xix) Checking of earthing resistance (xx) Cleaning of vegitation around the DG set up to 1.5 mtr area.
Supply only Radiator Coolent complete all as specified and directed by Engineer in charge.
Supply only Diesel/ Fuel filter (Primery&Secondary) for 25 to 100 KVA DG Set.
Supply only Diesel/ Fuel filter (Primery&Secondary) for 125 to 380 KVA DG Set.
Supply only Fan belt suitable for DG sets upto 380KVA capacity.
Supply only defective fuel injectors suitable for DG sets upto 380KVA capacity.
Supply only Engine oil / Lube filter suitable for 25 KVA to 100 KVA DG Set
Supply only Engine oil /Lube filter suitable for 125KVA to 380 KVA DG Set
Supply only Air cleaner elements inner and outer suitable for 45 KVA to 125 KVA DG Sets
Supply only Air cleaner elements inner and outer suitable for 250 KVA to 380 KVA DG Sets
Material and labour for replacement of lub oil pump suitable upto 380 KVA DG Set complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement Diesel pipe set flexible suitable upto 380KVA DG Set incl benjo bolts, copper washers complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair Lead acid battery 12 Volts, 150 AH with initially charged all as specified and as directed by Engr-in-Charge.
Supply only cotton waste for dialy use at power house for cleaning of the DG sets, pump motors complete all as specified and directed by Engineer in charge.
M&L for engine oil, multi grade 15W40.
Dismantling the radiator and fan assembly from the engine for cleaning of copper tubes and cooling fins by using descaling solution, soldering, patch work if any leakage including transporting to workshop for repair and bringing back to site upto 380 KVA all as directed by Engineer-in-Charge.
M&L for replacement of defective water pumping assembly upto 380 KVA all as directed by Engineer-in-Charge.
M&L for repairing of alternator of DG set having capacity upto 125 KVA DG set all as directed by Engineer-in-Charge including following: (a) Disconnecting electrical cable connection of alternator and DG set coupling complete. (b) Dismantling of alternator complete for rewinding including burntout winding field winding coils and cleaning slots. (c) Rewiring of armature and field coil with super enamelled copper winding wire insulated complete with suitable size of copper wire.(d) Material and Labour for replacement of u/s alternator bearing. (e) cleaning of commutator and replace carbon brush set complete including service of brush holders. (f) Re-assembling of alternator complete after the repair/rewinding and servicing of alternator, general cleaning and greasing of bearing and make good by provision of proper alignment and electic connection.
Supply and fixing in repair of AVR for DG set having capacity upto 125 KVA all as directed by Engr-in-Charge.
Supply and fixing in repair of AVR for DG set having capacity above 125 KVA all as directed by Engr-in-Charge.
S&F Self starter armature, 12V DC of make & model suitable for existing self starter.
S&F 12V solenoid coil suitable for DG set upto 380KVA capacity of existing make & model.
M&L for dismantling self starter 12 V of DG set for repairing the starter by replacing carbon brushes, brush holder, bearings, solenoid coil, replacement of burnt aremeture, rewinding of Fd coils, replace of pinion gears etc, complete servicing and refixing after repair, testing/commissioning complete for DG Set of any capacity
Supply & Fixing in repair of heat proof asbestos rope 12 mm dia in engine exhaust pipe including dismantling of worn out Asbestos rope and minor welding/tightening in leakage exhaust complete all as directed conforming to IS specification fire proof/flame proof.
Opening of AMF Panel, Cleaning of dust using blower, Checking/Detecting, Removal of Faults, Re-wiring of old u/s wiring & Testing of Control Wiring complete as reqd and closing of AMF Panel after replacement of u/s parts and testing all as specified & directed by Engineer-in-Charge.
S&F in replacement 2 core 10 Sqmm weather proof, PVC insulated and PVC sheathed multi stranded aluminium conductor cable, flat type 1100 volts as in service connection etc complete.
Supply & Fixing in repair of Indicating Light, 240V AC, LED Type Red, Yellow, Blue.
Supply & Fixing in repair of Digital DG Set Controller as per existing model.
Supply & Fixing in repair of Ammeter Digital Type of existing model.
Supply & Fixing in repair of Voltmeter Digital Type of existing model.
Supply & Fixing in repair of Self Carbon Bush suitable for DG Set.
Supply & Fixing in repair of Oil Pressure Gauge of existing model.
Supply & Fixing in repair of Push switch STOP EMERGENCY
Supply & Fixing in repair of Battery lead (using multistranded copper conductor with end terminal lugs)
Supply & Fixing in repair of Current Transformer (200/5) of existing model.
M & L in replacement earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to and including galvanized earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and excavation and earth work in any type of soil, PCC 1:3:6 type C1 in chamber, precast RCC cover 50mm thick in cement concrete 1:2:4 type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4 Kg/Sqm) with cast iron frame, funnel with wire mesh, 20mm bore GI pipe medium grade watering pipe, lugs, 40mm bore GI pipe medium grade protection pipe upto 7.5m. NOTE : Item includes the cost of earth lead and GI protection pipe upto 7.5m. GI wire beyond 7.5m shall be measured and paid for separately.
S & F in repair Changeover switch 200 Amps 415 Volt with sheet metal enclosure, side handle operated .
S & F in repair Changeover switch 100 Amps 415 Volt with sheet metal enclosure side handle operated..
S&F in replacement MCCB 400 Amps 03 Pole, 415 Volts, 50 Hz, 36 KA complete with spreader and connecting limbs etc. complete.
M&L for repairing of Fuel Feed Pump complete suitable upto 380KVA.
M&L for repairing/overhauling of DG set having capacity upto 125 KVA DG set all as directed by Engineer-in-Charge including following: (a) Disconnecting electrical cable connection of engine and DG set coupling complete. (b) Dismantling of engine complete for overhauling, burntout parts repair, cleaning slots greasing etc. (c) Material and Labour for replacement of u/s parts. (d) Re-assembling of DG Set complete after the repair/rewinding and servicing of engine, general cleaning and greasing of bearing and make good by provision of proper alignment and electic connection.
National Rewinding Works (BID ID -3100613)
M/s Shiv Builder and Suppliers (BID ID -3116711)
DEVARAM CONSTRUCTION COMPANY (BID ID -3101711)
Devi Engineeing (BID ID -3101637)
M/S Tanisha Traders (BID ID -3101942)
M/s Malinath Electricals (BID ID -3102221)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .