Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance A T ROAD JORHAT ASSAM 785001 | JORHAT | JORHAT | ASSAM | 785001 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance 13 D P STREET 13 DP STREET LILLYPUR HADDO SOUTH ANDAMAN ANDAMAN NICOBAR 744102 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744102 | Admitted-Finance |
Tender Value
₹4.8 L
EMD Value
₹9,600
Closing Date
19 Sept 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SO-1 (Wks)
SO-1 (Wks) HQ 25 Sect AR Jorhat (Assam)
Provision of repair and replacement of 11 KV two poles structure and allied E and M works for ARDTC under HQ 25 Sector AR, Jorhat
2023_ARMHA_771086_1
25 SECT/ENGR/MW-12/2023-24/05
Open Tender
Civil Works
Works
Jorhat
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
DIG HQ 25 Sector AR
₹9,600
7 Nov 2023
11 Sept 2023
20 Sept 2023
11 Sept 2023
19 Sept 2023
11 Sept 2023
11 Sept 2023 - 19 Sept 2023
Supply and fixing Gang operated air breaker switch triple pole vertical type 11 KV for current rating up to150 Amps double stack type mech operated mounted on insulator and steel frame with operating mechanisam work from ground level including operating rod GI tubing 25 mm dia medium grade single piece of 6.2 RM and handle complete including locking arrangement complete all as specified and directed by Engineer in Charge. Note- The AB switch shall be consist of 3 insulators per phase and 18 isolators.
Supply and fix drop out (DO) fuse unit expulsion type out door type 150 Amps rating single pole mounted in two insulators fixed to and including MS channel with nut bolt and washer, Synthetic bounded fuse carrying tube complete with HT fuse element up to 25 A capacity for HT 11 KV working pressure etc. complete all as specified and directed.
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for three wire 11KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (100 mm X 110 mm), G.I. bolts, nuts and washers, coach screws etc. as required
Disconnection of transformer 11 / 0.433 KV outdoor type of capacity 63 KVA removing primary and secondary terminals top cover with conservator tank neutral earth strip and draining out transformer oil and storeing to clean container ,cleaning of terminals , inspection of cores , replacement 5 mm thick rubberised cork sheet gasket for tank cover, reassembling the complete dismantled items reconnecting HT/LT supply cable ends complete all as directed .
Filtration of transformer oil 63 KVA outdoor type to achieving electric strength up to 40 KV for one minut at 4 mm gap as per relevant IS with portable filtration plant , testing of oil for di electric strength before and after filtration shall be conducted all as specified by the Engr- iin - Charge Note :- Test report after filtration to be produced to Dept.
M&L for replacing silica gel breather of the transformer 63 KVA capacity
M& L for cleaning of surface of the transformer of 11/0.433 KV , 63 KVA (make- Kirlosker) capacity by hand scraper removing the oil mark applying two coats of synthetic enamel paint suitable to existing colour all as specified and directed.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe of 2.7metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and laying in position cement concrete 1:3:6 (1 cement : 2 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required (Area- 2.0mx1.5mx.15m= 0.6 Cum)
Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels. . Area- (2.0X1.5)+ (2.0X 0.15)*2 + (1.5X0.15)*2 = 2.25 sqm
Supply 11 mtr PSC pole of 11 mtr (for 11 KV two pole structure) complete all as specified
Erection of RCC/ PCC pole of length 11 mtr in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required.
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required
Supply of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 70 sq. mm
Errection of one number XLPE power cable of 11 KV grade of 70 Sq mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 70 sq. mm 3 core, XLPE aluminium conductor cable of 11 KV grade as required
Supplying and fixing of light class G.I. pipe of 80 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required
M& L for cutting through existing bitumenous road of approx size width 50 cm depth 60 cm along cross section of the road for laying of GI pipe for encasing of cable after laying repairing the road to match with the original finishing by same way complete all as specified
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
M&L required T&P for taking out of transformer 11/0.433 KV 63 KVA capacity from existing position for necessary repairing work after repair, reainstalling & reconnecting HV and LV connection system and testing all as specified
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required Above 35 sq. mm and upto 95 sq. mm
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supply & laying jointing & testing in trenches on poles/ walls PVC XLPE insulated armoured heavy duty electric cable with aluminium multistrand conductor 1100 volt grade all as specified and directed of following cross sectional areas 70 Sqmm x 3 1/2 core.
Supply & Fix Brass compression gland for (38 mm) 3½ X 70 sq. mm 1.1 KV grade cable
Supply & Fix Aluminium lugs for 70 sq. mm cable
Ajay Enterprise
ANSIKA CONSTRUCTION
Mohan and Company
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .