| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.6 LAccepted-AOC | L1 | Accepted-AOC Accept | |
| 2 | L2₹44.9 L+₹5.0 L (12.5%)Rejected-Finance J L BHAWAN MANKAR ROAD BUD BUD BAZAR PO BUD BUD DISTT BURDWAN WB | BUD BUD | BURDWAN | WEST BENGAL | 713403 | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹50.0 L+₹10.1 L (25.2%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹50.2 L+₹10.3 L (25.7%)Rejected-Finance 16 N SANCHAR NAGAR EXTENSION NEAR JMB SWEETS INDORE 16 N SANCHAR NAGAR EXTN NEAR JMB INDORE KANADIYA ROAD INDORE MADHYA PRADESH 452001 | INDORE | MADHYA PRADESH | 452001 | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹51.1 L+₹11.2 L (28.1%)Rejected-Finance NEAR CENTRAL SCHOOL BALASORE DIST BALASORE ORISSA 756 001 | BALASORE | BALASORE | ORISSA | 756001 | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
22 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CHANDIPUR
GE I R and D Chandipur, Post- Chandipur, PIN-756025
WELCOME MAINTENANCE AND CERTAIN MISC BR AND EM REPAIR TO MD ACCN AT DEFENCE COLONY OT ROAD UNDER AGE BALASORE
2020_MES_347954_1
8566/CDP
Open Tender
Civil Works
Item Rate
334 days
CHANDIPUR
Please refer Tender Documents
6 documents required · 6 mandatory
₹500
Yes
GE I R and D Chandipur
₹88,000
Yes
14 Sept 2020
28 May 2020
24 Jun 2020
28 May 2020
22 Jun 2020
10 Jun 2020
60 days
Amount
PART-I (B/R PORTION) Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engineer-in-charge.
M&L Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even and smooth Without using extra cement complet including taking down old cement plaster all as specified.
M&L for 5 mm thick cement plaster in cement mortar 1:3 of ceiling, finished even and smooth with out using extra cement including taking down old cement plaster complete all as directed.
M&L three coats of white wash on newly plastered surfaces of wall including preparation of surfaces complete all as specified and as directed by Engineer-in-charge.
M&L Preparation of old plaster surfaces and one coat of white wash on wall complete all as specified and as directed by Engineer-in-charge.
M&L three coats of white wash on newly plastered surfaces of ceiling including preparation of surfaces complete all as specified and as directed by Engineer-in-charge.
M&L Preparation of old plaster surfaces and one coat of white wash on ceiling complete all as specified and as directed by Engineer-in-Charge.
M&L Preparation of new plaster surfaces on wall and applying two coats of oil emulsion distemper over one coat of alkali resistant priming paint on wall complete all as specified.
M & L Preparation of new plaster surfaces of walls and applying two coat of oil emulsion distemper over a coat of alkali resistant primer including a coat of 3mm thick wall care putty complete all as specified and directed
M&L Preparation of old plaster and two coat oil bound distemper applying of decorated plastered surfaces on wall complete all as specified and as directed.
M&L for preparation of old plastered surfaces and applying one coat of oil bound acrylic distemper over old plastered surfaces of wall surfaces complete all as specified and as directed.
M & L Complete removal of existing treatment of walls and applying two coat of oil emulsion distemper over a coat of alkali resistant primer including a coat of 3mm thick wall care putty complete all as specified and directed.
M & L applying one coat of plastic emulsion paint over old decorated surfaces including preparation of surfaces complete all as specified.
M&L preparation of old surfaces and applying one coat of synthetic enamel paint to wooden surfaces over 10 cm width or girth complete all as specified and as directed by Engineer-in-Charge.
M&L preparation of old surfaces and applying one coat of synthetic enamel paint to steel surfaces over 10 cm width or girth complete all as specified and as directed by Engineer-in-Charge.
Taking up or down steel water tubing and connecting incl cleaning for refixing or removal to stores for 15 mm bore complete all as specified and as directed by Engineer-in-charge.
Taking up or down steel water tubing and connecting incl cleaning for refixing or removal to stores for 20 mm bore complete all as specified and as directed by Engineer-in-charge.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed by Engineer-in-charge.
Taking down PVC(SWR) pipes including all fittings complete all as specified and as directed by Engineer-in-charge.
Taking down shutter of any description exc 1.00 sqm but n exc 2sqm complete all as specified and directed.
Taking down shutter of any description n exc 1.00 sqm complete all as specified and directed.
Taking down chowkath or frame exc 1.5 sqm n exc 4 sqm with shutter (without taking of shutters from frames ) complete all as specified and directed.
Taking down chowkath or frame n exc 1.5 sqm with shutter (without taking of shutters from frames ) complete all as specified and directed.
Resecuring or easening, adjusting without taking down of shutters exc 1 Sqm and n.exc 2 Sqm each in situ complete all as specified and as directed by Engineer-in-charge.
M&L Plain cement concrete 1:3:6, type C1 ( Using 20 mm graded aggregates ) in bed blocks for fixing hold fasts etc including necessary form work complete all as specified and as directed by Engineer-in-charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed by Engineer-in-charge.
S&F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, frame rabated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
S/F 35mm thick2nd class HW glazed and Skelton shutter open rebated and prepared and to receive gauze etc without sash bar complete all as specified and as directed by Engineer-in-charge.
S/F 35 mm thick factory made (two panel ) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces klin seasoned and chemically pressure treated complete all as specified and as directed by Engineer-in-charge.
S&F 35mm thick factory made flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides complete all as specified.
S&F 30mm thick 2nd class HW, glazed and skelton shutters open rebated and prepared to receive glass / gauge (without sash bar) edges of forming plain chamfered orrounded fitted with cut and mitred bead for securing glass / gauge etc size of shutter as per SSR part-1 section 8 clause 8.24(a).
S/F factory made solid panel PVC door shutter prelaminated one side 30 mm thick(style) conisiting of frame made out of M S tubes for top and bottomrails. MS frame shall be covered with heat moulded plain colour PVC ;C; channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail. Pannelling of plain colour PVC sheet to be fitted ithe MS frame welded/sealed to the stile and rail with suitable PVC sheet bedding and jointed with solvent cement as per specification and drawing.
S&F solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS Square tube, suppling & fixing in opening as per specification & drawing.
S&F in repair 12 mm thick prelaminated particle board , interior garde , prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screw to timber frame work complete all as specified and as directed by Engineer-in-charge. Make-Kitply/Greenply/National.
S&F in repair 18/19 mm thick prelaminated particle board , interior garde , prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screw to timber frame work complete all as specified and as directed by Engineer-in-charge. Make-Kitply/Greenply/National
S&F 75 mm long aluminium,anodised barrel tower bolts of extruded section complete all as specified and as directed by Engineer-in-charge.
All as per item here-in-before but 150 mm long complete all as specified and as directed by Engineer-in-charge.
S&F aluminium sliding door bolt 300mmlong, plate type, stove enamelled black, with bright bolt not less than 16mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and as directed by Engineer-in-charge.
S&F 100 mm size steel butt hinges medium weight , cold rolled complete all as specified and as directed by Engineer-in-charge.
S&F 75 mm size steel butt hinges medium weight , cold rolled complete all as specified and as directed by Engineer-in-charge.
S&F 300 mm long ms ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed by Engineer-in-charge.
S&F in repair 300 mm long ms ordinary rat tail rod pattern springs including roller and roller plate complete.
S&F 150 mm size alumunium handle, cast type, anodised complete all as specified and as directed by Engineer-in-charge.
S&F 75 mm size alumunium handle, cast type, anodised complete all as specified and as directed by Engineer-in-charge.
S/F in repair 100 mm hasp and staple brass with mild steel hinge pin including bolt to hinge plate fixed with screw complete all as specified and as directed by Engineer-in-charge.
S/F in repair brass handles,150mm long complete all as specified and as directed by Engineer-in-charge.
S&F in repair brass barrel tower bolts, extruded section 100mm long complete all as specified and as directed by Engineer-in-charge.
S&F in repair mild steel piano hinges, width of flaps 30mm complete all as specified and as directed by Engineer-in-charge.
S&F 140 mm floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring , fixed in floor complete all as specified and as directed by Engineer-in-charge.
S&F in repair 140 mm floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor complete all as specified and as directed by Engineer-in-charge.
S&F galvanised stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire stapple in repairs complete all as specified and as directed by Engineer-in-charge.
All as per item here-in-before but supplying and fixing in new doors and windows complete all as specified and as directed by Engineer-in-charge.
Hacking out old broken glass panes (any thickness size quality or description ) from wooden frame fixed with oil putty or beads area not exc 0.5 Sqm each all as directed.
S/F sheet glass ordinary quality and glazing with oil putty not exe 0.5 sqm in each pane 3mm thick complete all as specified and as directed by Engineer-in-charge.
Supply and fix 4mm thick frosted glass, ordinary quality and glazing with oil putty in squares not exceeding 0.50sqm in each pane complete all as directed.
Securing glass of any description in existing wooden metal frames glazed with oil putty beads including removing loose or decayed putty/ beads, painting/puttied surface to match existing work complete all as specified and as directed by Engineer-in-charge.
S&F in repairs for CP curtain rod 20mm dia with socket complete all as specified.
Supply & fix framed work such as grills, gratings, etc., with ends of bars shouldered and/or riv-eted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 390 Gde E-165 complete all as directed by the Engr-in-Charge.
M&L MS flat iron for hold fast and similar item conforming to Fe-290-0 complete all as specified and as directed by Engineer-in-charge.
M & L granite slab (of any type) 20 mm thick machine cut, bedded and jointed with gray cement slurry and pointed with white cement with admixture of pigments to match the shade of granite stone including cutting and polishing complete.
M&L PCC 25 mm thick PCC 1:2:4 type B-0 ( Using 12.5 mm graded aggregates), for laying floor finishes such as tiles etc complete all as specified and as directed by Engineer-in-charge.
M&L Rendering 10 mm thick cement plaster in CM 1:3 on fair faces of brick Work (internal surfaces) for fixing of wall tiling complete all as specified and as directed by Engineer-in-charge.
M&L for 15 mm thick screed bed or bedding layer of mortar in CM 1:6 for laying floor finishes for non skid ceramic and grinaite tiles complete all as specified and as directed by Engineer-in-charge.
M&L Glazed ceramic coloured tiles 450 x 350X7 mm thick coloured tiles as in dado, skirting and vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles complete all as specified and as directed by Engineer-in-charge.
M&L Non Skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exc 0.11 sqm ( 300 x 300 mm ) in floors etc set & jointed in neat cement slurry and pointed in coloured cement complete all as specified and as directed by Engineer-in-charge.
M&L Non Skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exc 0.18 sqm ( 400 x 400 mm) in floors etc set & jointed in neat cement slurry and pointed in coloured cement complete all as specified and as directed by Engineer-in-charge.
M&L for vertified ceramic tiles 10mm thick light shade (Square/rectangular) polished area of each tiles not exceeding 0.36 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed.
M&L Preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed by Engineer-in-charge.
M&L two coat syenthetic enamel paint over a coat of red oxide primer on new steel surface with complete preparation of surface.
S&F 20mm bore3-layer PP-R Polypropylene random copolymer)concealed pipes SDR 7.4(PN-16) UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc.
All as per item no here in before , but 25mm dia pipe complete all as specified and as directed by Engineer-in-charge.
Refixing of GI pipe with new fittings-15mm dia complete all as specified and as directed by Engineer-in-charge.
Refixing of GI pipe with new fittings-20mm dia complete all as specified and as directed by Engineer-in-charge.
S/F HDPE pipe of pressure 6 Kgf / sqcm fixed complete to walls/floor 50 mm dia complete all as specified and as directed by Engineer-in-charge.
S&F in repairs 500 litre capacity rotational moulded polythylene water storage tank ( cylindrical vertical with closed top) hoisted and fixed in position all as per specified in SSR part-I.Make-Sintex/Polycon
Disconnecting existing tanks of capacity Exc 250L and n. exc 500L , setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately)Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc complete all as specified and as directed by Engineer-in-charge.
S&F in repair 15 mm dia fancy type CP bib taps, cast copper alloy with crutch or butterfly handle, screwed down fixed in repairs complete all as specified and as directed by Engineer-in-charge.
S&F in repairs 15 mm dia fancy type CP pillar taps, cast copper alloy with capstan head, chromium plated screwed down fixed high pressure, long screwed shanks and fly nuts, screwed for iron pipe in repairs complete all as specified and as directed by Engineer-in-charge.
S&F in repairs 15 mm dia CP concealed type stop valves/ angular stop valves , cast copper alloy, screwed down,high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or unions in repairs complete all as specified and as directed by Engineer-in-charge.
S/F PVC ball valves high pressure with polythene float and fly nut complete, screwed for iron pipe of 20mm bore in repair complete all as specified and as directed by Engineer-in-charge.
S&F PVC grating doom 100 mm dia complete all as specified and as directed by Engineer-in-charge.
S/F PVC connection pipe 15mm size with PTMT nuts 450mm long complete all as specified and as directed by Engineer-in-charge.
S&F PVC (SWR & RWP) pipes single socketed in any length with rubber ring joints of dia 110mm fixed in repair complete all as specified and as directed by Engineer-in-charge.
S/F PVC (SWR & RWP) bends any radius of bore 110 mm incl. With access door fixed in repair complete all as specified and as directed by Engineer-in-charge.(SUPRME/PRINCE/ ORIPLAST)
S/F PVC (SWR & RWP) junction single (single 'Y') equal or un equal of bore 110 mm incl. With access door fixed in repair complete all as specified and as directed by Engineer-in-charge.(SUPRME/PRINCE/ ORIPLAST)
S&F PVC (SWR & RWP) pipes single socketed in any length with rubber ring joints of dia 75 mm fixed in repair complete all as specified and as directed by Engineer-in-charge. (SUPRME/PRINCE/ ORIPLAST)
S/F PVC (SWR & RWP) bends any radius of bore 75 mm incl. With access door fixed in repair complete all as specified and as directed by Engineer-in-charge. (SUPRME/PRINCE/ ORIPLAST)
S/F PVC (SWR & RWP) junction single (single 'Y') equal or un equal of bore 75 mm fixed in repair complete all as specified and as directed by Engineer-in-charge. (SUPRME/PRINCE/ ORIPLAST)
S/F PVC (SWR & RWP) floor trap plain with grating inclu. Jointing with solvent cement of out let dia 75mm fixed in repair complete all as specified and as directed by Engineer-in-charge.
M&L for vitreous china squatting pan of Orissa pattern size 580 X 440 mm white with intregal foot rest (excluding flushing cystern and flush pipe) in repairs complete all as specified and as directed by Engineer-in-charge.
M&L PVC valve less syphonic action type flushing cistern 10 ltr capacity low levelhigh level white with inlet ball valve , float flush pipe and handle including bracket fixed in repair complete all as specified and as directed by Engineer-in-charge.
S&F vitreous china wash hand basin white, flat back, size 550x400 mm with brackets including cutting for and pinning in end of brackets in repairs complete all as specified and as directed by Engineer-in-charge.
S&F sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard railing 60 cm long in repairs complete all as specified and as directed by Engineer-in-charge.
S/F brass chromium plated shower rose 125 mm size fixed in repair complete all as specified and as directed by Engineer-in-charge.
S&F Brass CP tubular towel rail, 20mm dia, "D" type, 60 cm long between flanges fixed in repair complete all as specified and as directed by Engineer-in-charge. (Make-Prayag/Jaquar)
S&F stainless steel sink, 1.00 mm thick for kitchen with plug, waste pipe, washer including cantilever cast iron bracket, connecting union overall size 915 mm x 460 mm with bowl size 410 mm x 330 mm x 160 mm fixed in repair complete all as specified and as directed by Engineer-in-charge. Make-Nirali/Blue star
S&F CP soap case in repair complete all as specified and as directed by Engineer-in-charge.
S & F in repair Bib tap of PTMT any colour 15 mm dia (Prayag as or equivalent) all as specified.
S & F in repair stop valve of PTMT any colour screwed for iron pipe and fixed 15 mm bore (Prayag as or equivalent) all as specified.
M&L vitreous china wash down water closet pan( pedestal pattern)nwhite fixed in repairs complete all as specified and as directed by Engineer-in-charge.
S & F plastic water closet seat white closed pattern with flat bottom and cover and mild steel chromium plated hinging devised fixed ir repair complete all as specified and as directed by Engineer-in-charge.
M & L health faucet Abs with Double lock 1.2 meter stainless steel flexible hose and wall hook complete all as specified and as directed by Engineer-in-charge.
S&F in repair stainless steel kitchen rack of 0.6 mm thick of approved make with plugs, washers, over all size 750mm x 600mm complete all as directed by Engr-in-Charge complete all as specified and as directed.
PART-II (E/M PORTION) Taking down carefully copper /aluminium point wiring (light, fan socket or power) complete, including fixture and fittings such as switches, ceiling rose, pendants, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as directed by Engr-in-Charge.
Supply and fix in repair circuit/sub-main wiring with PVC insulated & unsheathed two run of 1.5 Sqmm single core multi stranded copper conductor cable (FRLS), 1100 Volt grade alongwith one run of 1.0 Sqmm PVC insulated & unsheathed copper conductor cable (FRLS), 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through in pvc concealed conduit complete all as specified and as directed by the Engr-in-Charge. Note : (i) Two runs of 1.5 Sqmm and one run of 1.0 Sqmm cable shall measured as one length.
.-Ditto- all as per item No 106 here-in-before but through casing caping and -ditto-.
.Supply and fix in repair circuit/sub-main wiring (surface type) with PVC insulated & unsheathed two run of 2.5 sq mm single core multi stranded copper conductor cable (FRLS), 1100 Volt grade alongwith one run of 1.0 sq mm PVC insulated & unsheathed copper conductor cable (FRLS), 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through in pvc concealed conduit complete all as specified and as directed by the Engr-in-Charge. Note : (i) Two runs of 2.5 Sqmm and one run of 1.0 Sqmm cable shall be considered as single length.
.-Ditto- all as per item No 108 above but casing caping and -ditto-.
.Supply and fix in repair circuit/sub-main wiring (surface type) with PVC insulated & unsheathed two run of 4 sq mm single core multi stranded copper conductor cable (FRLS), 1100 Volt grade alongwith one run of 2.5 sq mm PVC insulated copper conductor cable (FRLS), 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through in pvc concealed conduit complete all as specified and as directed by the Engr-in-Charge. Note : (i) Two runs of 4 sqmm and one run of 2.5 sqmm cable shall be considered as one length.
.-Ditto- all as per item No 110 above but casing caping and -ditto-.
Supply and fix in repair circuit/sub-main wiring (surface type) with PVC insulated & unsheathed two run of 6 sq mm single core multi stranded copper conductor cable (FRLS), 1100 Volt grade alongwith one run of 4 sq mm PVC insulated & unsheathed copper conductor cable (FRLS), 1100 Volt grade,connected to common earth dolly as earth continuity conductor, drawn through in pvc concealed conduit complete all as specified and as directed by the Engr-in-Charge. Note : (i) Two runs of 6 sqmm and one run of 4 sqmm cable shall be considered as one length.
.-Ditto- all as per item No 112 above but through casing caping and -ditto-.
Material and labour for one light point or one Ceiling fan/ Exhaust fan point controlled by one switch wiring with copper conductor (FRLS) PVC insulated unsheathed cables of size 1.5 mm2 2 run and one run of 1.5 mm2 for earth continuity to be drawn in PVC concealed conduit non metallic not less than 20 mm width MS sheet metal switch / terminal box 1.2 mm thick and Hylum sheet switch including all necessary wall cutting for sinking's of boxes and making good disturbed surface to walls all as directed and specified .
All as per item No. 114 above but for 5 Amps independent switch point wiring with 2 x 1.5 mm2 copper conductor cable and 1.5 mm2 copper conductor cable as earth continuity conductor.
- Do- all as per item No. 114 above but on same board for 5 Amps switch point wiring with 2 x 1.5 mm2 copper conductor cable and 1.5 mm2 copper conductor cable as earth continuity conductor.
- Do - all as per item No. 114 above but for 5 /15 Amps independent switch point wiring with 2 x 4 mm2 copper conductor cable and 2.5 mm2 copper conductor cable as earth continuity conductor.
- Do - all as per item No. 114 above but for one bell/ buzzer point controlled by one push button on the same board with other swithces independent with 1.5 mm2 copper conductor cables.
- Do - all as per item No. 114 mentioned here in above but for one light point controlled by two way switches.ditto complete all as specified.
Material and labour for one light point or one Ceiling fan/ Exhaust fan point controlled by one switch wiring with copper conductor (FRLS) PVC insulated unsheathed cables of size 1.5 mm2 2 run and one run of 1.5 mm2 for earth continuity to be drawn in PVC casing caping, MS sheet metal terminal box 1.2 mm thick and Hylum sheet and making good disturbed surface to walls all as directed and specified .
All as per item No. 120 above but for 5 Amps independent switch point wiring with 2 x 1.5 mm2 copper conductor cable and 1.5 mm2 copper conductor cable as earth continuity conductor.
- Do- all as per item No. 120 above but on same board for 5 Amps switch point wiring with 2 x 1.5 mm2 copper conductor cable and 1.5 mm2 copper conductor cable as earth continuity conductor.
- Do - all as per item No. 120 above but for 5 /15 Amps independent switch point wiring with 2 x 4 mm2 copper conductor cable and 2.5 mm2 copper conductor cable as earth continuity conductor.
- Do - all as per item No. 120 above but for one bell/ buzzer point controlled by one push button on the same board with other switches or independent with 1.5 mm2 copper conductor cables
M&L in repair switch piano, flush type single pole, one way 5 Amps including connection complete all as directed by Engr-in-Charge.
M&L in repair switch piano, flush type single pole, two way 5 Amps including connection complete all as directed by Engr-in-Charge.
Supply and fixing of call bell Dingdong, 230 V AC, single pole complete all as directed by Engr-in-Charge.
Supply and fixing in repair bell push, flush type , 5 Amp complete all as directed by Engr-in-Charge.
M&L in repair switch socket combination 2 in 1, 5 Amps flush type including connection complete all as directed by Engr-in-Charge.
M&L in repair switch socket outlet multipurpose 3 Pin, 15 Amps and one 5 amps controlled by one switch complete all as directed by Engr-in-Charge.
M&L in repair ceiling rose PVC poly carbonate, isolated body with three terminals including connection complete all as directed by Engr-in-Charge.
S&F in repair stepped type electronic fan requlator flush type 230/240 volts complete all as directed by Engr-in-Charge.
M&L in repair lamp holder angular type PVC / Polycarbonate type insulated body with back plate suitable for batten fittings complete all as directed by Engr-in-Charge.
Supply and fixing in repair of MCB DB single door made of sheet steel phosphasted, powder painted with bus bar, neutral link, earth bar and din rail of SPN 8 way, 240 Volts double door fixed in wall including making good disturbed surfaces complete all as directed by Engr-in-Charge. Make : Havells or equivalent type of standard, Legrand
- do all as above but 04 way, 240V
- do all as above but double door 04 way, 415V
S&F in repair Isolator TPN, 415 Volt 100 A, Make : Havells/C&S/Legrand
S&F in repair MCB SPN 40 amps, 415 Volts, Make : Havells/C&S/Legrand
S&F in repair MCB SPN 63 amps, 415 Volts, Make : Havells/C&S/Legrand
S & F in repair MCB SPN 6-32 Amps Rating 240 volt, Make : Havells/C&S/Legrand
S&F in repair MCB SP 6-32 Amps Rating 240 volt, Make : Havells/C&S/Legrand.
S&F in repair LED type Bulk Head fitting e TARTA 6W engineering plastic housing with prismatic diffuser all as directed, Cat Part No : C&S cat no:CG801B10WLED, Make : Philips/CG
S&F in repair LED type intigrated batten fitting T5 Nakshatra Series indoor decorative aluminium extructed fitting 20W 4FT white all as directed. Make: C&S Cat Part No : LTIB4F20WLED/W Make : Philips/CG
-Do all as above but 10W, 2FT white,,Make :C&S CAT NO: LTTB2F10WLED/W or Philips/CG
S&F in repair LED T8 tubular lamp with pc body and diffuser and inbuilt driver ,white all as directed. Make: CG Cat Part No : LT-20-865-2 or equvelent make of Philips/C&s
S&F in repair AC single phase electronic kwh energy meter of sheet steel body/polycarbonate body ,counter type display with transparent hinhe type box,rating 5-30A, 240V make:HPL code no- SPPC1310000002OC00
Taking down geyser and scraping, cleaning including brazing of inner vessel of the geyser at leakage point to made it leak proof including testing pressure and assembling of all component refixing complete for 25 Ltr capacity complete all as specified and as directed by the Engr-in-Charge.
Supply and fixing as in replacement for heating elements of 1.5 /2 KW 230 V suitable for water heater of any type including connection with suitable cable complete all as specified and as directed by the Engr-in-Charge.
Supply and fixing as in replacement for thermostat switch of geyser 230 V, 30 degree to 90 degree centigrade temp range to be set at 70 degree to 50 degree centi grade suitable for water heater complete all as specified and as directed by the Engr-in-Charge.
Supply and fixing as in replacement for 450mm long brass CP braided hoses with 2 nuts without nipple suitable for geysers complete all as specified and as directed by the Engr-in-Charge. Make : Jaquar Cat No 805B or equivalent approved make.
Supply and fixing as in replacement for PVC inlet connector pipe 450mm long for geyser, heavy duty,with brass coupling both ends sutiable to fix inlet of geyser complete all as specified and as directed by the Engr-in-Charge. Make : Prayag/Polyfuf.
Supply and fixing as in replacement for apparatus plate , including suitable for water storage heater of 25 ltrs capacity complete all as specified and as directed by the Engr-in-Charge.
Material and labour preparation to old painted surface of storage water heater of 25 ltr capacity and painting with two coats of synthetic enamel paint (white) by using spray gun complete all as specified and as directed by the Engr-in-Charge.
Supply and fixing as in replacement for copper container suitable for Geyser 25 ltr complete all as specified and as directed by the Engr-in-Charge.
Taking down ceiling fan of any type, any make and any sweep for repairing, opening the body and blade, checking for repalcement of unserviceable minor spares like nut,bolt,bush,clamp & down rod as required and cleaning, overoiling, greasing, replacement of unserviceable spare by new one, re-assembling of all components in original position, testing and hanging up the same complete all as specified and as directed by the Engr-in-Charge. Note : New spare parts required for replacement shall be measured and paid seperately as 'Supply only"
Supply only Ball bearing of size 6201/6202/6203 for ceiling fan of 1200/1400mm Sweep complete all as specified and as directed by the Engr-in-Charge. Make : TATA/SKF
Supply only as in replacement 2.5mfd capacitor complete all as specified and as directed by the Engr-in-Charge.
.-Ditto- all as per item No 53 above but 3.5 mfd capacity and ditto.
Material and labour for painting of ceiling fan of size 1200mm & 1400mm sweep with down rod upto 2.00 mtr long with two coats of synthetic enamel spray white paint including preparation old painted surface including writing of MES No with letters n exc 15cm height complete all as specified and as directed by the Engr-in-Charge.
Rewinding of ceiling fan, 1200mm and 1400mm sweep with synthetic enamel copper wire including insulation of starter with polyster paper/manllex paper with cotontak binding, heat varnished and complete all as specified and as directed by the Engr-in-Charge.
Taking down exhaust fan of any type, any make and any sweep for repairing, opening the body and blade, checking for repalcement of unserviceable minor spares like nut,bolt,bush,clamp & down rod as required and cleaning, overoiling, greasing, replacement of unserviceable spare by new one, re-assembling of all components in original position, testing and hanging up the same complete all as specified and as directed by the Engr-in-Charge. Note : New spare parts required for replacement shall be measured and paid seperately as 'Supply only"
Supply only Ball bearing 2001/ 2002/ 2003 for exhaust fans complete all as specified and as directed by the Engr-in-Charge. Make : TATA/SKF
Rewinding of ceiling fan, exhaust fan of 230mm sweep with synthetic enamel copper wire including insulation of starter with polyster paper/manllex paper with cotontak binding, heat varnished and complete all as specified and as directed by the Engr-in-Charge.
.-Ditto- all as per item No 163 above but for exhaust fan of sweep exc 230mm but n exc 450mm and -ditto-.
Supply and fixing as in replacement M.S. galvanised louvers suitable for exhust fan of size 300/230mm sweep complete all as specified and as directed by the Engr-in-Charge.
Materials and labour for earthing as in repair complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 32 x 6mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed by the Engr-in-Charge.
Material and labour in replacement for Galvanised iron strip 32 x 6 mm burried in ground complete all as specified and directed by the Engineer-in-Charge.
FRIENDS CONSTRUCTION
M/s R.C REFRIGERATION
Ajay Associates
M/S T.N.CONSTRUCTION
jlenterprise
RANA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .