GE (WEST) FEROZEPUR CANTT
GE (WEST) FEROZEPUR CANTT
REPAIR TO SUMMER APPLIANCES AND CERTAIN EM WORKS UNDER GE (WEST) FEROZEPUR CANTT
2022_MES_570055_2
802022/GE-74/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
FEROZEPUR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (WEST) FEROZEPUR CANTT
₹50,000
Yes
3 Apr 2023
2 Mar 2023
24 Mar 2023
2 Mar 2023
22 Mar 2023
9 Mar 2023
Amount
WATER COOLER STORAGE TYPE Taking out existing compressor unit from the water cooler of capacity 40/80/120/150 Ltr of any make including removed of all other unserviceable parts/spares such as strainers, filter, capillary tubes suction /discharge pipe, thermostat switch, float valve, push cock running , starting capacitor, over load relay complete all as specified and directed
Supply and Fixing company repaired compressor in lieu of defective compressor to water cooler of 150 Ltr/Hr cooling capacity including Painting, jointing capillary tube and testing the compressor complete all as specified and directed
All as per Srl No. 2 here-in-before but of cooling capacity 60 Ltr/Hr.
All as per srl no. 2 here-in-before but of cooling capacity 40 Ltr/Hr.
Supply and fixing new compressor to water cooler of 150 Ltr/Hr cooling capacity including, jointing capillary tube and testing the compressor complete all as specified and directed. Make :Carrier / Tecumseh /Copeland/Hittchi/videocon/Bluestar
Supply and fixing new compressor to water cooler of 60 Ltr/Hr cooling capacity including, jointing capillary tube and testing the compressor complete all as specified and directed. Make :Carrier / Tecumseh /Copeland/Hittchi/videocon/Bluestar
Supply and fixing new compressor to water cooler of 40 Ltr/Hr cooling capacity including, jointing capillary tube and testing the compressor complete all as specified and directed. Make :Carrier / Tecumseh /Copeland/Hittchi/videocon/Bluestar
M & L for servicing of water cooler any size and make including drain out water cleaning of water tank and cleaning of condersor coil with anti scaling solution complete all as specified and directed.
Charging of water cooler with F-22/134a gas complete including replacement/filling of compressor oil of Make KAPILA 'B' after leakage test and testing of water cooler on full load for 24 hrs continuously at site of any Make of any capacity complete all as directed
Repairing the water cooler / body by replacing rusted MS sheet body with new MS sheet of 16 SWG approx area 2.5 Sq ft complete including replacement of unserviceable channel legs, fan motar base complete all as specified and directed.
Spray painting of water cooler of any make of capacity 150/120 ltrs with two coats synthetic enamelled paint of approved colour as approved by Engineer-in-Charge over a coat of red oxide primer complete including removing / scraping old paint, dust, preparation of surface, filling of metal putty and writing of MES No/ SM No of water cooler with Black paint complete all as specified as directed.
Spray painting of water cooler of any make of capacity 80/40 ltrs with two coats synthetic enamelled paint of approved colour as approved by Engineer-in-Charge over a coat of red oxide primer complete including removing / scraping old paint, dust, preparation of surface, filling of metal putty and writing of MES No/ SM No of water cooler with Black paint complete all as specified as directed.
Taking out existing unserviceable fan motor of capacity 1/8 HP from water cooler, dismantling the motor and taking out old burnt copper winding wire, rewinding of fan motor with similar size super enamelled copper winding wire of Make of HTP/devidayal after providing 'E' class insulation material complete including replacement of unsv pad MS clamps, nut and bolt, varnishing & refixing the motor in the water cooler and testing of water cooler complete all as specified and directed.
Supply, fixing and connecting in replacement new fan motor of water cooler capacity 1/8 HP 230 Volt 50 c/s of make MIE/Khaitan/ Crompton Greaves complete all as specified and directed
Replacement of fan blades of fan motor of water cooler of make sidwal of capacity 150 ltr made out of GI Sheet complete all as per existing shape and size.
Supply,fixing and connecting the Running capacitor 36 MFD of water cooler of capacity 120/150 Ltr complete all as specified as directed.Make – USHA/UNISTAR/TIBCON or equivalent.
All as per srl item 16 here in before but Starting capacitor 80-100 MFD
All as per srl item 16 here in before but Over load protector as per sample
All as per srl item 16 here in before but Starting relay 1/8 HP as per sample
All as per srl item 16 here in before but Plunger type relay as per sample
All as per srl item 16 here in before but Thermostat switch for water cooler as per sample
All as per srl item 16 here in before Push cock brass HD chromium plated
All as per srl item 16 here in before but float valve ½” dia, brass with ball.
All as per srl item 16 here in before but Rubber hose pipe/ for 1 ½” dia and 1.5 m long drain pipe.
All as per srl item 16 here in before but Over load/relay complete box type Y-412
REFRIGIRATOR 310 LTR Taking out existing compressor unit from the refrigerator of any capacity, of any make including removed of all other unserviceable parts/spares such as over load relay, bulb, strainer, thermostate switch, bulb holder, capillary tubes, freezer door complete all as specified and directed.
Taking out existing compressor unit from the deep freezer of any capacity of any make including removed of all other unserviceable parts/spares such as over load relay, bulb, strainer, thermostate switch, bulb holder, capillary tubes, freezer door complete all as specified and directed.
Supply & Fixing only company repaired compressor in lieu of defective compressor to refrigerator of 180/165 ltr capacity including jointing capillary and testing the compressor complete all as specified and directed
Supply & Fixing only company repaired compressor in lieu of defective compressor to refrigerator of 310/280 ltr capacity including jointing capillary and testing the compressor complete all as specified and directed
Supply & Fixing company repaired compressor in lieu of defective compressor to deep freezer of 200/250 ltr capacity including jointing capillary and testing the compressor complete all as specified and directed
Supply & Fixing company repaired compressor in lieu of defective compressor to deep freezer of 300/400 ltr capacity including jointing capillary and testing the compressor complete all as specified and directed
Supply and fixing new compressor to refrigerator of capacity 310 ltr including, jointing capillary tube and testing the compressor complete all as specified and directed. Make :Carrier / Tecumseh /Copeland/Hittchi/videocon/Bluestar
Supply and fixing new compressor to Deep freezer of capacity 320 ltr including, jointing capillary tube and testing the compressor complete all as specified and directed. Make :Carrier / Tecumseh /Copeland/Hittchi/videocon/Bluestar
Supply and fixing new compressor to Deep freezer of capacity 250 ltr including, jointing capillary tube and testing the compressor complete all as specified and directed. Make :Carrier / Tecumseh /Copeland/Hittchi/videocon/Bluestar
Charging of Deepfreezer/refrigerator with HC/R-12 gas of any size of any make complete including replacement of compressor oil of make capila 'B' and testing complete all as specified and directed
Supply,fixing and connecting Plunger type relay 1/6 HP of REFRIGERATOR complete all as specified and directed.
All as per srl item No 36 here in before but Over load protector 1/6 HP. Make Hitachi
All as per srl item No 36 here in before but Thermostat switch with knob - u-50-1018
All as per srl item No 36 here in before but Glass cover heavy duty of Refrigerator capacity 310 ltrs
All as per srl item No 36 here in before but Freezer door for whirlpool Refrigerator of Cap 310 ltr
All as per srl item No 36 here in before but Butter box / any try any type and size as per sample complete suitable for whirlpool/Samsung refrigarater of Cap 310 Ltr
All as per srl item No 36 here in before but Crisper tray forany make and size Refrigerater as per sample
All as per srl item No 36 here in before but Replacement of the existing damage choked evaporator from the Refrigerator of Cap 310 Ltr of any Make
All as per srl item No 36 here in before but Replacement of the existing damage choked evaporator from the Refrigerator of Cap 165 Ltr of any Make
Taking out exiting unserviceable fan motor of capacity 1/8 HP from the cooler/Deep freezer/Refrigerator dismantling the motor and taking out old burnt copper winding and rewinding of blower motor with similar size of super enameled copper winding wire of make: HTP/ Devidayal after providing 'E' class insulator material including replacement of bushes, Name pad and varnishing refixing the motor in the DF Ref and testing of Desert Cooler complete all as specified and directed.
Taking out exiting unserviceable fan motor of capacity 1/8 HP from the cooler/Deep freezer/Refrigerator dismantling the motor and connecting new fan motor complete all as specified and directed.
AIR CONDITIONER WINDOW TYPE 1.5 TON CAP Dismantling/Taking out existing unserviceable window type Air conditioner of capacity 1.5 Ton of any make and capacity and refixing the same to its position after serviceing with anti scaling solution and cleaning complete including removal of all other unserviceable parts/spares such as strainer, pillar suction, starting capacitor overload Running capacitor relay etc complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 47 here in before but split type AC of Cap 1.5 Ton.
Supply and fixing company repaired compressor in lieu of defective compressor to Air Conditioner of 1.5 Ton capacity including jointing compressor, capillary, replacement of reverse valve copper tubing as required and testing the compressor complete all as specified and as directed
Supply and fixing New compressor in lieu of defective compressor to Air Conditioner of 1.5 Ton capacity including jointing compressor, capillary, replacement of reverse valve copper tubing as required and testing the compressor complete all as specified and as directed. Make :Carrier / Tecumseh /Copeland/Hittchi/videocon/Bluestar
Supply and fixing New compressor in lieu of defective compressor to Air Conditioner of 1.5 Ton capacity including jointing compressor, capillary, copper tubing as required and testing the compressor complete all as specified and as directed. Make :Carrier / Tecumseh /Copeland/Hittchi/videocon/Bluestar
Supply and fix in replacement of copper tubing for split type Air conmditioner of 3/8inch or nay size required at site all as specified and directed by Enge-in-chrage
Charging of Air conditioner of capacity 1.5 TR with R-22 gas/as on site complete including replacement/ filling of compressor oil of make. Kapila 'B' connecting lead tin coated thumble and installation of AC at site testing on full load for 24 hrs continuously complete all as specified and directed
Dismantling taking out existing unserviceable fan motor of capacity 1/8 HP from window type Air conditioner/Split type dismantling the motor and taking out old burnt copper winding wire and rewinding of fan motor with similar size super enameled copper winding wire of make. HTP/Devidayal after providing 'E' class insulation material complete including replacement of unsv rubber pad MS clamp nut bolt varnishing and refixing the motor in the A/C and testing of Air conditioner complete all as specified and directed.
Supply & fixing outer unit of spilt type AC 1.5 Tonn of existing make complete all as specified and directed
Supply & fixing inner unit of spilt type AC 1.5 Tonn of existing make complete all as specified and directed
Supply & fixing PCB unit of spilt type AC of exsting make complete all as specified and directed
M&L for repair of existing UNSV PCB unit of spilt type AC of exsting make complete all as specified and directed
Supply & fixing in replacement of condensor coil of window type AC of 1.5 TR Capacity any make complete all as specified and directed
Supply & fixing in replacement of condensor coil of split type AC of 1.5 TR Capacity any make complete all as specified and directed
Supply,fixing and connecting Running capacitor 36 MFD complete all as specified and directed
All as per srl item No 61 here in before but Over Load protector No SR-1622 complete all as specified and directed
All as per srl item No 61 here in before but Starting capacitor 100-120MFD.
All as per srl item No 61 here in before but Starting Relay box type 1/8 HP SR-1622 complete all as specified and directed
Taking out existing unserviceable fan motor from the Air conditionor supply fixing and connecting new fan motor 1/8 HP 230 Volt 50 C/s single phase complete including MS clamps and rubber pad complete all as specified and directed.
M & L for shifting of air conditioner split type of any make from its original position to another position including dismantling brick work/making hole in wall, 10mm thick plastering with cement mortar 1:4 and 2 way DB with 32amp MCB required for it complete all as specified and directed.
M & L for shifting of air conditioner window type of any make from its original position to another position including dismantling brick work/making hole in wall, 10mm thick plastering with cement mortar 1:4 and 2 way DB with 32amp MCB required for it complete all as specified and directed.
DESERT COOLER Taking out exiting unserviceable fan motor of capacity 1/8 HP from the desert cooler/ dismantling the motor and taking out old burnt copper winding and rewinding of blower motor with similar size of super enameled copper winding wire of make: HTP/ Devidayal after providing 'E' class insulator material including replacement of bushes, Name pad and varnishing refixing the motor in the Desert Cooler and testing of Desert Cooler complete all as specified and directed.
Taking out existing unserviceable tulu pump (water pump) from the desert cooler supply and fixing connecting new tulu pump 1/20 HP 230 Volt 50 C/S single phase of Make - MIE/Khaitan all as specified and directed
Taking out existing unserviceable fan motor from the desert cooler supply fixing and connecting new fan motor 1/8 HP 230 Volt 50 C/s single phase complete including MS clamps and rubber pad complete all as specified and directed.
Replacement of Desert Cooler front show grill made of PGI sheet 20 gauge duly painted all as specified and directed.
Replacement of Desert Cooler sides Shutters made of PGI sheet 20 gauge with pad sporting frame of size duly painted all as specified and directed. (Set of 3)
Replacement of capacitor 4 MFD, 230 volts 50 c/s of complete all as specified and directed
Replacement of 3 way PVC distributer
Taking out unserviceable fan blades of fan motor from the desert cooler and supply and fixing new blade of standard quality and as per existing size complete all as specified.
Taking out existing serviceable fan motor and tulu pump from the unsv body of desert cooler carefully and supply of complete desert cooler body made out of GI sheet 18 gauge duly painted complete including shutters front show grill made out of GI sheet, wooden wool pad and refixing the fan motor and tulu pump and testing complete all as specified and directed
Painting of desert cooler body at site of any make and capacity with one coat of approved quality synthetic enamelled paint over a coat of red oxide primer after cleaning of dust rust and preparation of surface both inside and 0ut side complete all as specified and directed.
Supply and fixing PVC pipe 15mm dia 3 mtr in each cooler
Taking out unserviceable supporting leg fan motor with screw and fixing new supporting legs as per existing size complete all as specified and directed
Replacement of wood wool pad, supporting wire frame (set of three) and fixing in water cooler all as specified and directed.
REPAIR TO VOLTAGE STABILIZER OF CAPACITY 5 KVA MAKE - INTEG/NAYAR/ BLUE LINE COMPRISING THE FOLOWING: Dismantling and opening of main transformer and taking out of old burnt copper winding wire, rewinding of main transformer with supper enamelled copper wire of make HTP/Devidyal after provisioning 'E' class insulator material varnishing and refixing complete all as specified.
Dismantling of printed circuit board complex with condenser choke pre fixer and time delay relay and supply & fixing of new printed circuit board complete.
Supply and fixing volt meter 0-300 volt single phase 230 volt make Bajaj/Crompton/GEC
REPAIR TO VOLTAGE STABILIZER OF CAPACITY 4 KVA OF MAKE - INTEG/ NAYAR/ ELECTRON COMPRISING OF FOLLOWING Dismantling and opening of main transformer and taking out of old burnt copper winding wire, rewinding of main transformer with supper enamelled copper wire of make HTP/Devidyal after provisioning 'E' class insulator material varnishing and refixing complete all as specified.
Dismantling of printed circuit board complete with condenser dioel pre fixer of time delay relay. and supply & fixing of new printed circuit board complete.
Supply and fixing Bakelite connector in main connection lead
Supply and fixing indicator lamp Neon type (Green Red)
Supply and fixing volt meter 0-300 volts single phase 230 volt make Bajaj/Crompton/GEC
REPAIR TO VOLTAGE STABILIZER OF CAPACITY 3 KVA MAKE- ELECTRON COMPRISING THE FOLLOWING :- Dismantling and opening of main transformer and taking out of old burnt copper winding wire, rewinding of main transformer with supper enamelled copper wire of make HTP/Devidyal after provisioning 'E' class insulator material varnishing and refixing complete all as specified
Supply and fixing volt meter 0-300 volt single phase 230 volt make Bajaj or equivalent standard.
REPAIR TO VOLTAGE STABILIZER OF CAPACITY 1 KVA/ 0.5 KVA MAKE - INTEG ELECTRON/ RECOLD COMPRISING THE FOLLOWING Dismantling and opening of main transformer and taking out of old burnt winding wire and rewinding of main transformer with super enameled copper winding wire of make HTP/Devidyal afer provisioning 'E' class insulator material, varnishing and refixing including replacement of high and low cut of voltage relay and refixing of time relay delay condenser and testing of voltage stabilizer on full load for 8 Hrs
Supply and fixing indication lamp neon type (Red) complete all as specified and directed.
Supply and fixing of push type switch complete all as specified and directed.
Supply and fix Voltage stabilizer with 100% copper winding for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA . Make: Microtek/Voltas or equivalent.
Taking out carefully existing unserviceable copper PVC flexible 3 core cable and supply and fixing PVC sheathed copper cable 3 core of size 40/ 00.0076 complete all as specified and directed.
Taking out carefully existing unserviceable copper PVC flexible 3 core cable and supply and fixing PVC sheathed copper cable 3 core of size 70/ 00.0076 complete all as specified and directed.
M&L for replacment of UNSV existing reverse valve copper tubing as required on site for AC all as specified and directed.
Servicing and reairing of Aqua Guard water purifier of any cap with following replacment of Make :- Aqua guard, Kent (a) Primery filter
(b) UV light
(c) Carbon Candle
(d) Spun Candle
(e) Long Spun Candle
(f) Long CTO Candle
(g) Mini CTO Candle
(h) Booster Pump 100gpd
(j) SMPS Power Supply
(k) SV Copper
(l) 100 GPD membrane
(m) Carbon stone powder
(n) Sensor of UV light
(o) PVC pipe gripper at Primery filter ( set of two)
(p) Replacement of solonide switch
(q) PVC pipe of Aqua Guard as per exiting size
(r) Primary filter case with clamps
(s) Repairing of power circuit board
M/s Shri Krishna Enterprises
VK ENTERPRISES
M/s Bansi Lal
PAWAN KUMAR GOVT. CONTRACTORS
Brar Enterprises
manoj and company
R K BUILDERS
Ms Hari Singh
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .