Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.2 LAccepted-AOC HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L1 | Accepted-AOC L1 | |
| 2 | L2₹48.8 L+₹5.8 L (13.5%)Rejected-Finance BUDOOBAGH NOWPORA 0 KHANYAR SRINAGAR JAMMU KASHMIR 190003 | SRINAGAR | JAMMU AND KASHMIR | 190003 | L2 | Rejected-Finance Reject due to L2 | |
| 3 | L3₹48.9 L+₹5.9 L (13.8%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L3 | Rejected-Finance Reject due to L3 | |
| 4 | L4₹49.3 L+₹6.3 L (14.6%)Rejected-Finance H NO 89 BEHIND DD LEH UT LADAKH | LEH | LEH | LADAKH | 194101 | L4 | Rejected-Finance Reject due to L4 | |
| 5 | Rejected-Technical R O 218 05 OPP J D A COMPLEX TRIKUTA NAGAR JAMMU J K PIN 180020 | JAMMU | JAMMU AND KASHMIR | 180020 | - | Rejected-Technical Due to not having requisite category |
| Sl No | Description | Qty | Unit | Top Mind Industries Pvt Limited L2 | national engineering L1 | SUMEET TRADING CORPORATION L3 | M/S HIGHLAND ENGINEERING L4 |
|---|---|---|---|---|---|---|---|
| 1.00COMPREHENSIVE MAINT OF ELECTRIC FIRED CHS AND SOLAR WATER HEATING DEVICES AT KHUMBATHANG | |||||||
| 2.00 | Material and labour for removing / opening of electric boiler control panel for checking serviceable state of control wiring and switches which includes replacement of minor parts (control wiring and other necessary items for making the panel serviceable) complete all as specified and directed by Engr-in-charge. | 4 | Each Job | 10,000 ₹40,000 | 7,500 ₹30,000 Lowest | 8,500 ₹34,000 | 8,000 ₹32,000 |
| 3.00 | Dismantling of mono block electric motor set of capacity 3 HP and taken it to civil workshop for rewinding the motor with existing size of super enamelled copper wire including all necessary insulating material and refixing the moter set at the original position and testing it on full load upto the entire satisfactrion of EIC. complete all as specified and directed by Engr-in-charge.
Note : Transpotation charge of motor from site to workshop and back is deemed to be included in the item rate | 4 | Each Job | 9,000 ₹36,000 Lowest | 11,200 ₹44,800 | 12,000 ₹48,000 | 11,500 ₹46,000 |
| 4.00 | Dismantling of mono block electric motor set of capacity 5 HP and taken it to civil workshop for rewinding the motor with existing size of super enamelled copper wire including all necessary insulating material and refixing the moter set at the original position and testing it on full load upto the entire satisfactrion of EIC. complete all as specified and directed by Engr-in-charge.
Note : Transpotation charge of motor from site to workshop and back is deemed to be included in the item rate | 3 | Each | 12,000 ₹36,000 Lowest | 13,000 ₹39,000 | 16,000 ₹48,000 | 15,500 ₹46,500 |
| 5.00 | Supply only glycol / coolant alongwith the necessary additives and inhibitor in cognition and supplied in barells complete all as specified and directed by Engr-in-charge. | 600 | Litre | 180 ₹1,08,000 | 140 ₹84,000 Lowest | 150 ₹90,000 | 145 ₹87,000 |
| 6.00 | Supply and fix heater bank of capicity 25 KW for electric based central heating system including thermostat as per the existing/suitable capacity all as specified and directed incl taking down old one complete all as specified and directed by EIC | 4 | Each | 15,000 ₹60,000 | 13,000 ₹52,000 | 11,000 ₹44,000 | 10,000 ₹40,000 Lowest |
| 7.00 | Supply and fix heater bank of capicity 7 KW for electric based central heating system all as specified and directed incl taking down old one complete all as specified and directed by EIC | 4 | Each | 12,000 ₹48,000 | 8,370 ₹33,480 Lowest | 12,000 ₹48,000 | 10,000 ₹40,000 |
| 8.00 | Supply and fix in repair heater bank of capicity 5 KW for electric based central heating incl thermostat of suitable capacity and other connected accessories incl taking down old one complete all as specified and directed by Engr-in-charge. | 4 | Each | 8,000 ₹32,000 | 7,500 ₹30,000 Lowest | 10,000 ₹40,000 | 8,000 ₹32,000 |
| 9.00 | Material & labour for complete decarbonising of boilers including replacement of damaged refractory complete all as specified and directed by Engr-in-charge. | 10 | Each Job | 10,000 ₹1,00,000 | 9,350 ₹93,500 Lowest | 12,000 ₹1,20,000 | 15,000 ₹1,50,000 |
| 10.00 | Supply and fix pressure switch incl taking down old one complete all as specified and directed by Engr-in-charge. | 2 | Each | 7,500 ₹15,000 | 3,250 ₹6,500 Lowest | 5,000 ₹10,000 | 4,500 ₹9,000 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
29 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE KHUMBATHANG
HQ CWE KHUMBATHANG PIN 900270 C/O 56 APO
COMPREHENSIVE MAINT OF ELECTRIC FIRED CHS, OIL FIRED CHS AND SOLAR WATER HEATING DEVICES AT KHUMBATHANG UNDER GE KHUMBATHANG
2025_MES_718951_1
80051/23/2025-26
Open Tender
Civil Works
Item Rate
180 days
KHUMBATHANG
Class D cat c (i)
8 documents required · 8 mandatory
₹500
GE KHUMBATHANG
₹90,000
Yes
14 Oct 2025
8 Jul 2025
30 Jul 2025
8 Jul 2025
29 Jul 2025
23 Jul 2025
8 Jul 2025 - 22 Jul 2025
Amount
COMPREHENSIVE MAINT OF ELECTRIC FIRED CHS AND SOLAR WATER HEATING DEVICES AT KHUMBATHANG
Material and labour for removing / opening of electric boiler control panel for checking serviceable state of control wiring and switches which includes replacement of minor parts (control wiring and other necessary items for making the panel serviceable) complete all as specified and directed by Engr-in-charge.
Dismantling of mono block electric motor set of capacity 3 HP and taken it to civil workshop for rewinding the motor with existing size of super enamelled copper wire including all necessary insulating material and refixing the moter set at the original position and testing it on full load upto the entire satisfactrion of EIC. complete all as specified and directed by Engr-in-charge. Note : Transpotation charge of motor from site to workshop and back is deemed to be included in the item rate
Dismantling of mono block electric motor set of capacity 5 HP and taken it to civil workshop for rewinding the motor with existing size of super enamelled copper wire including all necessary insulating material and refixing the moter set at the original position and testing it on full load upto the entire satisfactrion of EIC. complete all as specified and directed by Engr-in-charge. Note : Transpotation charge of motor from site to workshop and back is deemed to be included in the item rate
Supply only glycol / coolant alongwith the necessary additives and inhibitor in cognition and supplied in barells complete all as specified and directed by Engr-in-charge.
Supply and fix heater bank of capicity 25 KW for electric based central heating system including thermostat as per the existing/suitable capacity all as specified and directed incl taking down old one complete all as specified and directed by EIC
Supply and fix heater bank of capicity 7 KW for electric based central heating system all as specified and directed incl taking down old one complete all as specified and directed by EIC
Supply and fix in repair heater bank of capicity 5 KW for electric based central heating incl thermostat of suitable capacity and other connected accessories incl taking down old one complete all as specified and directed by Engr-in-charge.
Material & labour for complete decarbonising of boilers including replacement of damaged refractory complete all as specified and directed by Engr-in-charge.
Supply and fix pressure switch incl taking down old one complete all as specified and directed by Engr-in-charge.
Material and labour for replacement of damaged nitrile insulation of 19 mm thick over pipes of CHS of any size as required at site complete all as specified and directed by Engr-in-charge.
Material and labour for replacement of damaged aluminium cladding of any pipe size complete as required at site complete all as specified and directed by Engr-in-charge.
Supply and fix contactor A-26-30-10, 13 NO in repair AC 3 phase complete all as specified and directed by Engr-in-charge.
Supply and fix contactor MNX 9, in repair AC 3 phase complete all as specified and directed by Engr-in-charge. Make : L &T /ABB/Schnider
Material and labour for descaling of radiator panel associated with CHS installed at UGSC & FSH complete all as specified and directed by Engr-in-charge.
Labour for servicing of fan coil unit of indoor units, removing dust / other remains with suitable liquid complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of wall mounted fan coil unit of capacity 1.5 TR (4500 K Cal/Hrs 600 Cfm) complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of wall mounted fan coil unit of capacity 1.0 TR (3000 K Cal/Hrs 600 Cfm) complete all as specified and directed by Engr-in-charge.
Supply, installation, testing and commissioning of wall mounted type hecco panel of size 600mm x 300mm x 18mm or rating of 100W each, complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement PVC insulated stranded copper conductor size 2.5 Sqmm 2 core for connection anti freezing tracer complete all as specified and directed by Engr-in-charge.
Supply and fix in repair step up control system for 6 step including metre,control board and control wiring suitable for 63 KW electric boiler complete all as specified and directed by Engr-in-charge.
Supply and fix inrepair step up control system for 6 step including metre,control board and control wiring suitable for 45 KW electric boiler complete all as specified and directed by EIC.
Supply and fix in repair step up control system for 6 step including metre,control board and control wiring suitable for 75 KW electric boiler complete all as specified and directed by Engr-in-charge.
Supply and fixing in repair Relay 8 pin (MY2N) 240 Volt AC, for central heating system complete all as specifed and directed. Make :- Omron
Supply and fixing in repair Relay 14 pin (MY4N) 240 Volt AC, for central heating system complete all as specified and directed by Engr-in-charge.
Supply and fixing in repair Relay 8 pin (LY2N) 240 Volt AC, for central heating system complete all as specified and directed by Engr-in-charge.
Supply and fixing in repair Control module card, for central heating system complete all as specified and directed by Engr-in-charge.
Supply and fixing in repair step switch set, for central heating system complete all as specified and directed by Engr-in-charge.
Supply and fixing in repair push button switch, for central heating system complete all as specified and directed by Engr-in-charge.
Material and labour 3 layer PP-R Polypropylene random copolymer pipes SDR 7.4 & SDR 11 UV of the following sizes stabalised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass thereaded polypropylene random fittings to be laid in trenches/walls/floors etc.complete all as specified and directed. Note:- All connected PPR fittings viz. elbow, coupling, Tee, Reducer etc. any type/size as per existing shall be counted in RM for PPR Pipes. complete all as specified and directed by Engr-in-charge. (a) 25 mm dia
Material and labour 3 layer PP-R Polypropylene random copolymer pipes SDR 7.4 & SDR 11 UV of the following sizes stabalised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass thereaded polypropylene random fittings to be laid in trenches/walls/floors etc.complete all as specified and directed. Note:- All connected PPR fittings viz. elbow, coupling, Tee, Reducer etc. any type/size as per existing shall be counted in RM for PPR Pipes. complete all as specified and directed by Engr-in-charge. (a) 32 mm dia
Material and labour for PP-R gate valves (Brass insert) of the following sizes complete all as specified and directed by Engr-in-charge: - (a) 25 mm dia PPR pipe
Material and labour for PP-R gate valves (Brass insert) of the following sizes complete all as specified and directed by Engr-in-charge: - (a) 32 mm dia PPR pipe
Material and labour for welding of copper pipes using butane gas cylinders complete all as specified and directed by Engr-in-charge.
Supply and fixing in repair copper tubing dia as required at site suitable for hot and cool Air conditioning connection complete all as specifed and sirected by Engr-in-charge
Supply and fixing Level switch for central heating system complete all as specifed and directed by Engr-In-Charge.
COMPREHENSIVE MAINT OF OIL FIRED CHS AND SOLAR WATER HEATING DEVICES AT KHUMBATHANG
Supply only glycol alongwith the necessary additives and inhibitor in cognition and supplied in barells complete all as specified and directed by Engr-in-charge.
Material and labour for taking up/down unserviceable pump motor of capacity from 1 HP to 3 HP removing burnt winding and rewinding with new copper wire of suitable size, varnishing and painting of the exterior body complete with servicing by greasing, changing bushes/flanges and bearings of suitable size, refixing with new bolt and nuts of suitable size complete all as specified and directed by Engr-in-charge. Note:- Item rate includes replacement of unserviceable/wearout/tearout parts like nuts, bolts, washer, gaskets, rubber rings alongwith necessary major unserviceable parts of the motor.
Material and labour for complete decarbonising of boilers including replacement of damaged refractory complete all as specified and directed by Engr-in-charge.
Material and labour for replacement of damaged nitrile insulation of 19 mm thick over pipes of CHS of any size as required at site complete all as specified and directed by Engr-in-charge.
Material and labour for replacement of damaged asbestos rope insulation of 10 mm thick over Duct (outside) of CHS 200x200 mm size as required at site complete all as specified and directed by Engr-in-charge.
Material and labour for replacement of damaged aluminium cladding of any pipe size complete as required at site complete all as specified and directed by Engr-in-charge.
Labour only for opening the Oil based boiler, dismantaling the accessories and cleaning the boiler including replacement of necessary minor accesories as per site requirement complete all as specified and directed by Engr-in-charge.
Material and labour for descaling of radiator panel associated with CHS installed at signal center and A Mess complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of sequence control LOA24 with base of boiler complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of iginition transformer of boiler complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of Nozzle (1.5/45) 60 degree 2 GPH of boiler complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of iginition electrode complete all as specified and directed by Engr-in-charge.
Material and labour for replacement of fuel pump burner assembly (BFP 21 R3 with lead) complete all as specified and directed by Engr-in-charge.
Supply and fixing repair starter panel for diesel fired air heating of capacity 25000KCal/Hr complete with all accessroies such as contractor, relay, start/off button, amp meter, volt meter etc complete all as specified and directed by Engr-in-charge.
Supply and fixing in repair starter panel for diesel fired air heating of capacity 50000KCal/Hr complete with all accessroies such as contractor, relay, start/off button, amp meter, volt meter etc complete all as specified and directed by Engr-in-charge.
Supply and fixing repair starter panel for diesel fired air heating of capacity 100000KCal/Hr complete with all accessroies such as contractor, relay, start/off button, amp meter, volt meter etc complete all as specified and directed by Engr-in-charge.
Supply and fixing in repair the unsv diesel fired burner of capacity 25000Kcal/hr including the complete complete accessories like sequence controller with base, feul pump, Electrode, nozzle, transformer, photocell, diesel filter etc complete all as specified and directed by Engr-in-charge.
Supply and fixing diesel fired burner of capacity 50000Kcal/hr including the complete accessories like sequence controller with base, feul pump, Electrode, nozzle, transformer, photocell, diesel filter etc complete all as specifed and directed by EIC
Supply and fixing diesel fired burner of capacity 100000Kcal/hr including the complete accessories like sequence controller with base, feul pump, Electrode, nozzle, transformer, photocell, diesel filter etc complete all as specifed and directed by EIC
Supply and fixing diesel fired burner of capacity 200000Kcal/hr including the complete accessories like sequence controller with base, feul pump, Electrode, nozzle, transformer, photocell, diesel filter etc complete all as specifed and directed by EIC.
Supply fixing in repair the unsv photocell to make the burner serviceable complete all as specifed and directed by the Engr-in-charge.
Supply fixing in repair the unsv diesel filter to make the burner serviceable complete all as specifed and directed by the Engr-in-charge.
Supply and Fixing in repair 500 LPD solar water tank complete all as specified and directed by Engr-in-charge.
Supply and Fixing in repair solar plate gasket complete all as specified and directed by Engr-in-charge.
Supply and Fixing in repair borosilicate tube suitable for 500 LPD solar water heating system complete all as specified and directed by Engr-in-charge.
Supply and Fixing in repair flat plate collector (FPC) suitable for 500 LPD solar water heating system complete all as specified and directed by Engr-in-charge.
Supply, fabrication and installation in repair of return air ducting made of galvanised steel sheet metal casing cross section 400x400mm (24 gauge) with reoprene rubber gasket, elbow, split dampers, vanes, hagers, support etc complete all as specifed and directed by Engr-in-charge
Supply and fixing in repair copper tubing 8mmx12mm dia suitable for hot and cool Air conditioning connection complete all as specifed and directed by Engr-in-charge
Supply and fixing in repair voltage stabilizer of capacity 5 KVA, 50Hz, 220 volt complete all as specified and directed by Engr-in-charge.
Material and labour 3 layer PP-R Polypropylene random copolymer pipes SDR 7.4 & SDR 11 UV of the following sizes stabalised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass thereaded polypropylene random fittings to be laid in trenches/walls/floors etc. complete all as specified and directed by Engr-in-charge. Note:- All connected PPR fittings viz. elbow, coupling, Tee, Reducer etc. any type/size as per existing shall be counted in RM for PPR Pipes.complete all as specified and directed. (a) 25 mm dia
Material and labour 3 layer PP-R Polypropylene random copolymer pipes SDR 7.4 & SDR 11 UV of the following sizes stabalised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass thereaded polypropylene random fittings to be laid in trenches/walls/floors etc. complete all as specified and directed by Engr-in-charge. Note:- All connected PPR fittings viz. elbow, coupling, Tee, Reducer etc. any type/size as per existing shall be counted in RM for PPR Pipes.complete all as specified and directed. (a) 32 mm dia
Material and labour for PP-R gate valves (Brass insert) of the following sizes complete all as specified and directed by Engr-in-charge: - (a) 25 mm dia PPR pipe
Material and labour for PP-R gate valves (Brass insert) of the following sizes complete all as specified and directed by Engr-in-charge: - (a) 32 mm dia PPR pipe
Supply and Installation of Fuel line complete all as specified and directed by Engr-in-charge.
Supply and fix Ball Valve for Oil Tank complete all as specified and directed by Engr-in-charge.
Supply and fix Hexa Nipple for Oil Tank complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of wall mounted fan coil unit of capacity 1.5 TR (4500 K Cal/Hrs 600 Cfm) complete all as specified and directed by Engr-in-charge.
Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 1,78,789.00 and any other reduction if any from quoted amount.
Top Mind Industries Pvt Limited (BID ID -3370639)
SUMEET TRADING CORPORATION (BID ID -3376154)
M/S HIGHLAND ENGINEERING (BID ID -3374536)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .