Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹20.8 L+₹1.1 L (5.40%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹21.8 L+₹2.0 L (10.3%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹23.5 L
EMD Value
₹47,000
Closing Date
28 Dec 2021, 5:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
SPECIAL REPAIRS TO ROOF FLOORING AND RE WIRING WATER PIPE LINE OF BLDG NO P 238 OF 11 MAHAR 08 SRW AT SI LINES UNDER GE BHOPAL
2021_MES_490742_1
8834/E8
Open Tender
Civil Works
Item Rate
180 days
BHJOPAL
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE BHOPAL
₹47,000
Yes
8 Feb 2022
26 Nov 2021
3 Jan 2022
26 Nov 2021
28 Dec 2021
14 Dec 2021
Amount
Note : Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below:-
Dismentling of Asbestos cement (corrugated or semi corrugated, etc.) sheets in roof covering complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and directed.
Taking down chowkats with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and directed.
Taking down shutters of any description not exceeding 1 Sqm each, complete all as specified and directed.
Taking down shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each complete all as specified and directed.
Taking up or down steel tubing and connections 15 mm bore, including cleaning (tubings and connections) for refixing or removal to store, complete all as specified and directed.
Taking up or down steel tubing and connections 20 mm bore, including cleaning (tubings and connections) for refixing or removal to store, complete all as specified and directed.
Dismantling of reinforced cement concrete in ground floors and pavings not exc 15 cm thickness (below or above ground level) (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
Demolition to cement concrete in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of brickwork or stone masonry built in cement or cement lime mortar complete all as specified and directed.
M&L for Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth complete all as specified and directed.
M&L for cutting holes in brick walls exc half brick but n exc one brick in cement mortar for incerting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete type B1, 1:2:4 as required, complete all as specified and directed.
S&F Pressed steel frames of size 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, with & including filing of cement concrete typ B-0, 1:2:4 using 12.5mm graded stone aggregates inside frames complete all as specified and directed.
S&F Steel work in tubular/structural trusses, purlins, etc including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS.1161-1979 grade St.-240 or steel sections conforming to Fe 410-W (Gde E-250) quality -A complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet, 0.5mm thickness, of colour as approved by GE, having tensile strength of 550 Mpa as in roof coverings/cladding to wall, etc, fixed with & including self tapping screws on angle frame complete all as specified and directed. [MAKE: TATA BLUE SCOPE / EVEREST INDUSTRIES/JINDAL]
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet, 0.5mm thickness, of colour as approved by GE, having tensile strength of 550 Mpa as in ridges, etc, fixed with & including self tapping screws complete all as specified and directed. [MAKE: TATA BLUE SCOPE / EVEREST INDUSTRIES/JINDAL]
S&F Mild steel conforming to Fe-290 Gde E-165 in framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars; ladders; railings and similar work complete all as specified and directed.
M&L for Providing cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate in cills, seismic and other similar bands, plinth courses, copings, bed plates, bond stones, roof kerb, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed.
S&F Steel water tubes, medium grade, ISI marked, galvanised, 15 mm bore with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and directed. [MAKE: TATA/ SURYA/ JINDAL/ PRAKASH]
S&F CPVC pipes, SDR 11 and plain CPVC SDR 11, 16 mm bore with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and directed.
S&F Steel water tubes, medium grade, ISI marked, galvanised, 20 mm bore with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and directed. [MAKE: TATA/ SURYA/ JINDAL/ PRAKASH]
M&L for Non skid ceramic coloured tiles 7mm to 8mm thick (square/rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors, skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles with & including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for Glazed ceramic coloured tiles 350mm x 250mm x 7mm thick or 450mm x 350mm x 7mm thick, in vertical surfaces such as skirting, dados and risers to steps, etc set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles with & including 10mm thick rendering in CM 1:3 complete all as specified and directed. [MAKE: SOMANY/ KAJARIA/ ORIENT/ JOHNSON]
M&L for Machine cut Kota stone slab flooring 20-25mm thick (size not less than 450mm x 600mm) with and including 20mm thick cement screed base in CM 1:3, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and mirror polishing complete all as specified and directed.
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar, etc with and including 10mm thick rendering in CM 1:3 and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and mirror polishing complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing tiles/ rubbish off the permises to a distance not exceeding 250m complete all as specified and directed.
Roughning of surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc, complete all as specified and directed.
M&L for 25mm thick Cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregate in sub base, complete all as specified and directed.
M&L for 18-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including grinding, moulding and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L for making good under cills and over arches, lintels and bressummers including all pinning where necessary in cement mortor 1:6, complete all as specified and directed.
Supplying, fabricating and fixing powder coated (minimum thickness 50 micron) aluminium sections of required size for door, windows, ventilators frames and shutters and partitions including aluminium hinges of required size jointing cleats, screws sash fasteners, plug for fixing with walls, columns, etc complete all as specified and directed. [MAKE: JINDAL/ AJIT INDIA/ HINDALCO]
S&F Sheet glass 4.8mm thick, ordinary quality and glazing with oil putty/rubber seal in squares not exceeding 0.5Sqm in each pane complete all as specified and directed.
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F Butt hinges, medium weight, cold rolled mild steel, 100 mm size complete all as specified and directed.
S&F Butt hinges, medium weight, cold rolled mild steel, 75 mm size complete all as specified and directed.
S&F Butt hinges, extruded alluminium alloy with galvanised mild steel hinge pin, anodised and fixed, 100 mm size complete all as specified and directed.
S&F 150 mm Aluminium handles, cast type, anodised complete all as specified and directed
S&F 100 mm Aluminium handles, cast type, anodised complete all as specified and directed
S&F 150 mm Aluminium anodised barrel Tower bolts extruded section and fixed complete all as specified and directed
S&F 100 mm Aluminium anodised barrel Tower bolts extruded section and fixed complete all as specified and directed
M&L for factory made second class hardwood glazed and skeleton door shutters 35mm thick, open rebated and prepared to receive glass, gauze, etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc complete all as specified and directed.
M&L for factory made, second class hardwood 35mm thick plain, framed, panelled shutters (any number of panels) with panels of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face veneers complete all as specified and directed.
M&L for Preparing new or previously untreated surfaces of wood and wood based materials of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over and including a coat of pink primer complete all as specified and directed.
M&L for preparing old painted surfaces of wood and wood based materials of any description over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
S&F 300mm long aluminium alloy anodised Sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed
S&F 15 mm wash basin mixutre, centre hole, mixing hot & cold water, fancy type, cast copper alloy, chromimum plated with capstan head, chromium plated, screwed down high pressure, screwed for iron pipe etc and fixed in repairs complete all as specfied and directed Make : Jaquar Cat No: 5001B or equivalent in Pragag/ Hindware equivalent
S&F handshower (Health faucet) with 8mm dia 1 meter long flexible tube and wall hook fixed in repairs complete all as specfied and directed Make: Jaquar Cat No- 573 or equivalent in Pragag/ Hindware.
S&F Chromium plated grating doom, including jointing with solvent cement, dia of outlet 100 mm complete all as specified and directed.
S&F in repairs PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F Bib taps cast copper alloy chromium plated with crutch or butterfly handle, fancy type, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified and directed. [MAKE:- Prayag (Cat No.8606) or equivalent in JAGUAR/MARC as approved by GE]
S&F Factory made solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed.
S&F Factory made solid 2mm thick moulded prelam panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top & bottom rails. MS frame shall be covered with heat moulded palin colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame wlded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, fixing tin the frame at site as specified and directed.
S&F PVC (SWR) floor/Nahani trap, plain with CP grating including jointing with solvent cement, dia of outlet 75 mm complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittings, heads, etc. including cleaning or refixing or removal to store, complete all as specified and directed.
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches, floors or fixed to walls, 75 mm bore complete all as specified and directed.
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches, floors or fixed to walls, 110 mm bore complete all as specified and directed.
S&F PVC (SWR) bends any radius, 75 mm bore complete all as specified and directed.
S&F PVC (SWR) bends any radius, 110 mm bore complete all as specified and directed.
S&F PVC (SWR) branch piece (single Y), equal or unequal, 75mm bore complete all as specified and directed.
S&F PVC (SWR) branch piece (single Y), equal or unequal, 110mm bore complete all as specified and directed.
S&F PVC (SWR) junction single (single T), equal or unequal, 75mm bore complete all as specified and directed.
S&F PVC (SWR) junction single (single T), equal or unequal, 110mm bore complete all as specified and directed.
S&F PVC (SWR) vent cowl 75mm bore complete all as specified and directed.
S&F PVC (SWR) vent cowl 110mm bore complete all as specified and directed.
S&F in repair PVC Flexible waste pipe 32 mm dia with socket for steel sink upto floor level and length not less than 0.60 M complete all as specified and directed.
S&F in repairs plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminum hinging device complete all as specified and directed. [MAKE:-PRAYAG/SOMANY/CERA/PARRYWARE /HINDWARE]
S&F in repairs Vitreous china urinal half stall ISI marked, white, with & including chromium plated waste coupling including connections to flush pipe and outgoing pipes complete all as specified and directed. [MAKE:-SOMANY smart / HINDWARE (Cat No.60002 starwhite) or equivalent in CERA/PARRYWARE as approved by GE.]
S&F in repairs Vitreous china squatting pan ‘Orissa’ pattern, size 580 x 440 mm, white with integral foot rests including provision of cement concrete bedding & ‘P’ or ‘S’ trap complete all as specified and directed. [MAKE:-SOMANY (Cat.No.121115) or equivalent in CERA /PARRYWARE/ HINDWARE as approved by GE.]
S&F in repairs tubular towel rail of aluminium anodised, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. [MAKE:- Prayag (Cat No.BA-40) or equivalent in JAQUAR/MARC as approved by GE]
S&F in repairs PVC low level flushing cistern 10 litres capacity, ISI marked, white, with all fitting and fixtures including brackets, PVC connection of 450mm long and 32 mm bore PVC flush pipe, complete all as specified and directed. [MAKE:- SOMANY (Cat No.121002), Prayag (Cat No.501 Smart flush cistern) or equivalent in PARRYWARE-SLIMLINE/CERA as approved by GE]
S&F Sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12.5 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed. [MAKE:- Prayag (Cat No.BEA-43) or equivalent in JAGUAR/CERA as approve by GE]
S&F two way Bib taps cast copper alloy chromium plated with crutch or butterfly handle, fancy type, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified and directed. [MAKE:- Prayag (Cat No.8612) or equivalent in JAGUAR/MARC as approved by GE]
S&F in repairs Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, fancy type, chromium plated, with long shank and cup (concealed type) screwed both ends for iron pipe or for unions 15mm bore complete all as specified and directed. [MAKE:- Prayag (Cat No.8618) or equivalent in JAGUAR/MARC as approved by GE]
M&L for rendering 15mm thick in cement mortar 1: 4 on faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. Note:- WPC shall be mixed where directed by Engr in charge and WPC shall be measured and paid seperately
M&L for rendering 15mm thick in cement mortar 1: 6 on faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed. [MAKE: ACCOPROOF/WATER SEAL/MC BOUCHAMIE, MUMBAI/FOSROC/CICO/PIDILITE]
Taking down cement or cement lime plaster, any description, on brick or stone walls, ceilings, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for applying 3mm thick wall care putty (Make: Birla/JK) complete all as specified and directed.
M&L for Cement concrete 1:3:6 type C2 using 40mm graded stone aggregate in plinth protection, 75mm thick, finished even and smooth without using extra cement, including making joints 12mm wide to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight complete all as specified and directed.
M&L for Brick work with fly ash bricks (Modular), straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L for Brick work with fly ash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed.
M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed.
M&L for struck pointing to random or polygonal rubble masonry, uncoursed or brought up to course in cement cement mortor 1:4 complete all as specified and directed.
M&L for Preparing new or previously untreated steel & iron surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over & including a coat of red oxide zinc chrome primer complete all as specified and directed.
M&L for preparing old painted steel & iron surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed
M&L for Factory made, machine pressed, M-35 grade concrete interlocking paver blocks (glossy /reflective type), with grey cement and pigment, any shape and size conforming to IS:15658-2006 (ISI Marked) of 60 mm thickness with & including 50 mm thick stone dust cushion and joints filled with sand complete all as specified and directed. [MAKE:- MEHTAB / NAVYA TILES / SAP PAVERS/ SAGAR TILES]
M&L for preparation of old/new surface and applying two coats of damp proof chemical (Acra coat of make Dr. Fixit) over a coat of cement based white putty, complete all as specified and directed.
M&L for Reinforced cement concrete design mix M-25 in slabs supported on walls, beams & columns complete all as specified and directed.
Use and waste of form work to soffits of suspended slabs as in roof slabs, floor slabs, landings and similar work not exceeding 200mm thick for rough finished flat surfaces complete all as specified and directed.
M&L for racking out joints/pointing to squared rubble masonry, coursed or uncoursed in cement or cement lime mortor, complete all as specified and directed.
S&F Mild steel TMT bars 10mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F Mild steel TMT bars 6 to 8mm dia as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Preparing new plastered or unplastered surfaces of wall and M&L for applying two coats of exterior acrylic emulsion paint, white or tinted over and including a coat of exterior wall primer on plastered surfaces complete all as specified and directed. [Make :Shalimar(Saktiman) / Asian(ACE) / Burger(wall masta)]
Complete removal of existing treatment and M&L for applying two coats of exterior acrylic emulsion paint, white or tinted over and including a coat of exterior wall primer on plastered surfaces complete all as specified and directed. [Make :Shalimar(Saktiman) / Asian(ACE) / Burger(wall masta)]
Preparing new plastered or unplastered surfaces of wall and M&L for applying two coats of distemper oil emulsion, white or tinted over a coat of primer and including 3mm thick wall care putty (Make: Birla/JK) on plastered surfaces complete all as specified and directed.
Complete removal of existing treatment and M&L for applying two coats of distemper oil emulsion, white or tinted over a coat of wall care putty on plastered surfaces complete all as specified and directed. Note : Putty shall be measured and paid seperately
S&F drepary rod decorative type min 25mm dia, curtain rod cromium plated with side fixing brackets, rings & decorative knobs complete all as specified and directed.
M&L for ShaliCryl ® 215 single component, UV resistant, unique elastomeric, high build exterior waterproofing coating based on a revolutionary acrylic polymer with quick-set capabilities to resist moisture attack. (a) Surface Preparation :- Remove all loose and foreign materials, if any, by a wash with a jet of air / water. • Repair structural defects before application of ShaliCryl® 215. • Fill voids and undulation area with Polymer Mortar made out of ShaliSBR Latex, Water, Cement and Sand in the Ratio of 1:1:5:12.5. • Fill cracks up to 3 mm with PlastiSeal and cracks over 3 mm with PlastiSeal P after opening the crack to a “V” cut. • In case of any poor plaster surface in existence (for old building), remove the same and corrected with new cement : sand in the ratio of 1 : 4 admixed with ShaliPlast LW+ @ 200 ml / bag of cement. (b) Primer Application :- Apply ShaliPrime WB as Primer after dilution with potable water in the ratio 1:0.5 for a theoretical Coverage 8-10 m2 / L of the mix and allow it to dry for 3 – 4 hrs. post elimination of undulation, roughness of concrete, joint marks, Voids and any other surface correction. (c) Application of Material • Apply first coat of ShaliCryl® 215 over the primed surface @ 160 ml / m2 . Add maximum of 10% potable water by volume for the first coat only, if required, to have brushable consistency only. • Allow the applied coating to dry 6 – 8 hrs of application. • Apply second coat of ShaliCryl® 215 without dilution over dried first coat @ 140 ml / m2 and allow it to dry. • Do not undertake any further work over the coated area within 72 hrs of final coat. • A coat of 100 micron of ShaliCryl TC 100 will improve water / dust repellent property.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning etc and hosting if required, reconneting and refixing in position capacity exc 500 and n exc 1000 ltr. including Cleaning and removing all scale and dirt etc from tanks and from mouth of circulating pipes etc complete all as specified and directed.
Refixing old steel tubing 20 mm bore, with and provision of new fittings (connections) in new or old position (walls, ceiling, floors, etc) complete all as specified and directed.
Refixing old steel tubing 15 mm bore, with and provision of new fittings (connections) in new or old position (walls, ceiling, floors, etc) complete all as specified and directed.
S&F in repairs wall mixture for mixing hot & cold water, fancy type, chromium plated, screwed for iron pipe or for unions 15mm bore, with provision for over head shower and long pipe and wall flanges complete all as specified and directed. [MAKE:- Prayag (Wall mixer cat No.7375) or equivalent in JAQUAR / PLUMBER / MARC as approved by GE]
S&F in repairs vitreous china wash down water closet pan, pedestal pattern, ISI marked, white, including plastic water closet seat, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminium hinging device complete all as specified and directed. [MAKE:-SOMANY (Cat No.120403 & 120404) or equivalent in CERA/PARRYWARE /HINDWARE as approved by GE.]
S&F in repairs chromium plated shower rose 125 mm size with swivel joints complete all as specified and directed. [MAKE:- Prayag (Cat No.BS-76) or equivalent in JAGUAR/CERA as approve by GE]
S&F in repairs stainless steel hand rails, Gde 304 conforming to IS of approved design including ornamental fittings globes and all necessary drilling, bolting, riveting, welding etc. fixed in steps/floors steps etc. complete all as specified and directed. Make-Jindal steel or equivalent as approved by GE
S&F in repairs prelaminated partcle board 18 mm thick, exterior grade, prelaminated one side with decorative choice lamination and other side with balancing white lamination fixed with screws to timber frame work including external fixing of teak wood liping 6 mm thick with nails and french polishing on wooden surfaces complete all as specified and directed.
Taking down existing old roof treatment of any description, type and in any position including removal of old tiles, screed, felt, etc complete all as specified and directed.
M&L for grouting by pressure injection with cement slurry of 50kg cement mixed with Pidicrete SM 225gms of M/s Pidilite industries Ltd. Or Cobex 100 of M/s Fosroc Chemicals as per instructions, complete all as specified and directed.
M&L for Water proofing treatment on roof surfaces with APP modified membrane with non woven polyester reinforced, weight not less than 3 KG/SQM and thickness of membrane not less than 3mm laid in following sequence including applying a coat of aluminium paint over APP membrane complete all as specified and directed.:- (a) Complete removal of existing treatment including padding/plastering (which shall be measured under item No 110.00) (b) Conduct ponding test for 72 hrs, after ponding test grouting is to be done at the leakage area as directed by Engr in charge (Grouting shall be measured under item No 111.00) (c ) After the surface is repaired with pressure grouting the slab will be tested for water tightness again for 72 hrs before processing further treatment. (d) Applying 10mm thick plaster in CM 1:4 mixed with water proofing compound [Make; Dr.Fixit Pidiproof LW+ of M/s Pidilite Industries or STP No. 1 (liquid) of M/s STP Ltd] @ 3% by weight of cement on cleaned roof surface. (e) Properly cleaning and drying of the plastered roof surfaces, parapets, gutters, drain mouths, etc for all foreign matters such as fungus, moss, dust, etc by wire brushing and dusting. Proper grooves shall be cut around CI drain outlets/pipes/chimney pipes and other similar situations to tuck in the treatment. (f) Applying a coat of bituminous primer conforming to IS: 3384-1965 @ 0.3Kg/Sqm on the prepared surface till the surface is properly impregnated. (g) Laying APP modified water proofing membrane with 100mm overlap in longitudinal direction and 100mm overlap in transverse direction sealed and bounded to the surface by torch application method. (h) All joints and changes in direction should be curved with cement mortar 1:3 with SBR latex @ 200ml per bag of cement and cured well before laying the membrane. A fillet of PCC 1:2:4 type B0 using 12.5mm graded stone aggregates shall be provided at all junctions of vertical and horizontal surfaces and wherever there is change of direction. (j) 72 hrs testing of treatment for water tightness by ponding of water.
S&F in repairs Vitreous china wash basin, ISI marked, white, flat back, size 550 x 400mm, including CP waste coupling, 32mm dia PVC waste pipe of suitable length, brackets and cutting for and pinning in ends of brackets, complete all as specified and directed. [MAKE:-SOMANY (Cat No.110107) or equivalent in CERA/PARRYWARE /HINDWARE as approved by GE.]
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface of walls, floors, etc.complete all as specified and directed.
M&L for point wiring complete for light/fan/exhaust fan on independent / combine with cable 1.50 sqmm (nominal area), FRLS PVC insulated, unsheathed, single core multi-stranded copper conductor cable, 1100 volts grade, ISI marked controlled by one one-way switch, drawn through and including concealed medium grade PVC conduit not less than 20 mm dia, ISI marked, with all accessories (PVC casing and capping of size 25 mm , ISI marked with complete accessories to be used wherever wiring to be run on ceilings and concrete surfaces) including one run of 1.5 sqmm FRLS muti-stranded copper conductor (green colour cable) as earth continuity wire connected to common earth dolly, including sunk sheet steel terminal box made out of 1.20 mm thick and not less than 60 mm in depth GI/MS/ pressed steel terminal box to be concealed in wall, duly painted with two coats of anti corrosive black bituminous paint over a coat of red oxide primer in and out sides and two coated of aluminium paint on internal surface , including laminated hylum sheet cover, ISI marked for mounting of fittings like switches, sockets, fan regulators, etc. fixed with galvanised screw and cup washer complete all as specified and directed. Note : (i) Wiring to be done as per approved colour code in IE rule.(ii) Rate includes chase cutting for concealed wiring. [Make of Cable : Polycab/ Plaza/ Havells]
All as per BOQ item No. 115.00 here-in-before, but for one switch socket combination 5/6 Amp on independent board, complete all as specified and directed.
All as per BOQ item No. 115.00 here-in-before, but for one three pin outlet 5 Amp on same board with other switches, complete all as specified and directed.
All as per BOQ item No. 115.00 here-in-before, but for one switch socket combination 6 pin 5 /15 Amp on independent board with wire of size 2.5 sqmm and 2.5 sqmm as earth wire, complete all as specified and directed.
S&F Switch piano, flush type, single pole, one way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Bell push, flush type, 6 Amp piano type, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA PC series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Switch socket combination 5 pin, type 5/6 Amps flush type, 230 volt AC complete all as specified and directed. MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE
S&F Socket outlet 5 pin 5 Amp flush type, 240 volt AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Switch socket combination 6 pin, type 5/15 Amps flush type, 230 volt AC complete all as specified and directed. MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE
S&F Ceiling rose surface bakelite, three terminals, 240V, 50Hz, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Bell, Ding Dong type, electric, single phase, 240 volt, AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA PC series) or equivalent in LEADER/ CRABTREE/LEGRAND /HAVELLS as approved by GE]
S&F LED tube light fitting, surface mounted lumanaires, 1 x 18 W, 240V, decorative ultra slim round /squar profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack with bipin holders, LED lamps,connector block, etc. complete with all accessories internally pre-wired and including connecting up with flexible copper conductor cable of suitable size complete all as specified and directed. Make : Havells Cat No : LHEXBLP7N1W018 or equivalant in C&G/Bajaj/Surya
Refixing of serviceable light fitting any type any make retrieved against item No. 126.00 with connection complete all as specified and directed.
Supply & fixing LED light fitting mirror type with hig out put diffuser 2 feet, 10 watt, 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible coppder conductor cable of suitable size complete all as specified and as directed [Make : Havells/CG/Bajaj or equivalent as approved by GE]
S&F Angle holder, PVC/Poly carbonate type with back plate suitable for conduit fittings complete all as spcified and directed. [MAKE FOR HOLDER:-ANCHOR (PENTA PC series)/ LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F LED lamp 10 watt, B22 CDL complete all as spcified and directed.
S&F LED light fitting, 1x10 W bulk head luminaries, with lamp holders, etc complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230 V, 50 Hz including 10 Watt LED lamp complete all as specified and as directed. (Make: Havells cat No HEXFT10WLED857SSYMBOPC/ Bajaj/C&G/Surya)
S&F building security light fitting 35 W made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC over having top opening separate driver compartment with IP-66 protection and impact resistance of IK07 with suitable galvanised iron pipe 'light grade' brackets 1 mtr length bent to shape to obtained required shape including clamps, nuts, bolts, washers etc. connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and as directed. [Make : Havells/CG/Bajaj or equivalent as approved by GE]
S&F steping type electronic fan regulator, of socket size complete all as specified and directed. (Make:- Legrand (Cat. No.573469) or equivalent in Anchor ROMA DEKO 'D' series / Crabtree)
M&L in replacement for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 6.0 sqmm nominal cross section area and drawing into and including surface 20mm dia, rigid non metallic PVC conduit, ISI marked, medium grade, / casing caping size 20 mm inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc and PVC insulated stranded copper conductor of 6.0 sqmm nominal cross section area as earth wire complete all as specified and directed. Note: - (i) Two runs of 6.0 sqmm cable, one run of 6.0 sqmm cable of earth continuity conductor & PVC conduit pipe/ casing caping shall be measured as one unit length.(ii) Cutting chases & making good for concealed sub main wiring will be measured and paid sepeartely under susequent item. [Make of Cable : Polycab/ Plaza/ Havells]
Supply and fixing factory made epoxy powder coated Distribution Board TP & N 4 ways ( VTPN MCCB DB ) and space for MCCB as incomer, with metal door ( IP-43 protection ) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including isolated Neutral Bar, Insulated busbar assembly, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified and directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE] NOTE:- MCCB shall be measured and paid seperatly.
S&F of MCCB 4 pole, 415 Volt fixed type, 100 Amp 16kA breaking capacity complete all as specified and directed. Make :- Havells/Indo Asian /L&T.
S&F in replacement sheet metal enclosure double door type surface mounted concealed in wall 8 ways, 240 Volts, ISI marked 200 amps bus bar dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE] NOTE:- MCB shall be measured and paid separately.
S&F in repairs MCB SP, 240 volts, 10 KA breaking capacity, 'C' curve, of capacity 5 to 32 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE]
S&F in repairs MCB SPN suitable for 240 volts, AC supply 6 to 32 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE]
S&F in repairs MCB SPN suitable for 240 volts, AC supply 50 to 63 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE]
Taking down carefully existing ceiling fan any type any make, incl servicing and painting of ceiling fan with white enameled paint and refixing after cleaning and painting and connection with flexible copper wire upto ceiling rose and checking of nuts bolt washers & safety pin etc complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR-2009 Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by 15mm dia light grade GI pipe and watering pipe shall be 20mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed. NOTE :- (i) The concrete pit shall be PCC (1:3:6) type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) The unit rate includes the cost of GI pipe medium grade for protection of earth wire and 4mm dia earh lead wire upto 7.5 M. (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated materials (soil) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
S&F 40mm GI tubing light grade with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S.flat iron clamps incl nut,bolt and washer including taking down old rusted pipe complete all as specified and directed. [MAKE:-TATA / JINDAL / PRAKASH / SWASTIK as approved by GE]
Cutting of bituminous road/PCC hard standing/road/floor for laying of GI pipe upto 80mm dia (trench not more than 0.3m x 0.3m) for passing of cable including making good the disturbed surfaces all as per existing complete all as specified and directed.Note:-GI pipe shall be measured & paid separately under relevant items of this schedule.
Supply, laying, connecting and testing LT XLPE insulated, screened, PVC bedded, armoured, heavy duty cable with aluminium conductor of size 25 sqmm, 3.5 core, 1100 volts grade, laid in trenches, passing through pipes/ducts, etc including taking out old unserveciable cable, any type complete all as specified and directed. [MAKE:- POLYCAB /HAVELLS INDIA LTD/V-MARC as approved by GE]
M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection (8 cm below cable & 15 cm above cable) complete all as specified and directed. [Note:-Compacted/punned thickness shall be measured & paid]
Supplying and laying sub class 'B' bricks (modular) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed.
Deduct schedule of credit (calculation will be done off line) Rs. 35895.00
Samaksh Enterprises
M/S RAKESH TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .