| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹33.4 LAccepted-AOC | L-1 | Accepted-AOC Being the lowest bidder | |
| 2 | L-2₹37.6 L+₹3.3 L (9.66%)Rejected-AOC | L-2 | Rejected-AOC Not being the lowest bidder | |
| 3 | L-3₹40.0 L+₹5.7 L (16.6%)Rejected-AOC | L-3 | Rejected-AOC Not being the lowest bidder | |
| 4 | L-4₹41.2 L+₹6.9 L (20.3%)Rejected-AOC | L-4 | Rejected-AOC Not being the lowest bidder | |
| 5 | L-5₹41.3 L+₹7.1 L (20.6%)Rejected-AOC | L-5 | Rejected-AOC Not being the lowest bidder |
Tender Value
Refer Docs
EMD Value
₹72,000
Closing Date
15 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL SANGRAM SINGH
GE Kaluchak Pin-900673 C/o 56 APO
SPECIAL REPAIRS TO BUILDING NO T161 T72 T2 T3 T4 AND T5 BOUNDARY WALL OF CSD DEPOT COMPLEX AND PROVN OF 01 TOILET BLOCK UNDER CERTAIN UNITS OF BD BARI MIL STN UNDER GE KALUCHAK
2020_MES_378469_1
GE/KC/NIT-48/2020-21
Open Tender
Civil Works
Item Rate
180 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹72,000
Yes
24 Nov 2020
17 Sept 2020
17 Oct 2020
17 Sept 2020
15 Oct 2020
3 Oct 2020
17 Sept 2020 - 2 Oct 2020
60 days
Amount
B/R Portion
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils exceeding 50m but not exceeding 100m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Cement concrete type D-2 1:4:8 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
Demolition of brick work masonry built in cement mortar including all quoins, pillars etc. but excluding ashlars facing, dressed stone work and precast concrete articles complete all as specified and as directed.
Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, complete all as specified and directed.
Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, complete, but except brick, i.e. using serviceable bricks obtained from demolition, complete all as specified and as directed.
Plain cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in roof padding, roof kerbs or mud stops, kerbs etc and in similar works including weathering, slightly rounded or chamfered angles and throating and necessary form work complete, all as specified and as directed.
Plain cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in cills, lintels upto 1.5 metre clear span, steps, seismic and other similar band, plinth course, string courses, lacing courses, parapets and railing upto 60cm in height, copings, kneelers, apex stone, bed plates, kerbs etc and in similar works including weathering, slightly rounded or chamfered angles and throating and necessary form work complete, all as specified and as directed.
Reinforced Cement Concrete Design Mix M-25 (using 20 mm graded crushed stone aggregate) as in foundation including footing, foundation beam, plinth beam, base of column and mass concrete complete as required, complete all as specified and as directed.
Reinforced Cement Concrete Design Mix M-25 (using 20 mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
Reinforced Cement Concrete Design Mix M-25 (using 20 mm graded crushed stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and as directed.
RCC 1:2:4 (Nominal mix) Type B-1 (using 20mm graded crushed stone aggregate ) in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
RCC 1:2:4 (Nominal mix) Type B-1 (using 20mm graded crushed stone aggregate ) as in slabs supported on walls, beams, lintel bands and in columns in floors or roofs, landings, balconies and in shelves and the like complete all as specified and as directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finish flat surfaces of concrete, complete, all as specified and as directed.
Formwork to flat surfaces of concrete to side and soffit of floor & roof beam, lintel, in floor or roofs, landings, balconies and shelves etc rough finish flat surfaces of concrete, complete, all as specified and as directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finish flat surfaces of concrete, complete, all as specified and as directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions and similar work; finish flat surfaces of concrete, complete, all as specified and as directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20cm wide and sides of RCC / PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm rough finish surfaces of concrete, complete, all as specified and as directed.
TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified and as directed.
TMT bars 5mm dia and over upto and including 10mm dia, cut to length bent to shape including binding with MS annealed wire of dia not less than 0.90mm as in stirrups, spacers and binders, complete, all as specified and as directed.
Taking down cement plaster on bricks or stone wall/ceiling decayed surfaces of concrete from roof projection or RCC chajjas etc. including racking out joints, hacking for key, scrubbing down with water etc., complete all as specified and directed.
Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces, using water proofing compound, finished even and smooth with out using extra cement, complete all as specified and directed. (Note : Water proofing compound shall be measured and paid seperately under respective items)
Rendering 15mm thick in cement mortar 1:6 on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement, complete all as specified and directed.
Rendering 5mm thick in cement mortar 1:3 on fair faces of brick work or concrete surfaces as in ceilings finished even and smooth without using extra cement, complete all as specified and directed.
Rendering 10mm thick in cement mortar 1:3 on roof slab surfaces, using water proofing compound as per manufacturer instructions finished even and smooth without using extra cement, complete all as specified and directed. (Note : Water proofing compound shall be measured and paid seperately under respective items)
Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth with out using extra cement, complete all as specified and directed.
Supply only Liquid Water proofing Compound all as specified and as directed.
Hard core of broken stone gauge exceeding 63mm and not exceeding 100mm deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surfaces, complete, all as specified and as directed.
75 mm thick Cement concrete type D-2, 1:4:8 (using 40 mm graded crushed stone aggregate) in sub base, complete all as specified and directed.
75mm thick, plain cement concrete 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection etc., finishing surface even and smooth without using extra cement including making joints with bitumastic filling in proportion of bitumen and sand 1:3 by weight complete as specified and directed. Note : The concrete shall be laid at a stretch not exceeding 3.0 m in length and joint shall be made at every turning / corners, complete all as specified and directed.
Demolition of cement concrete in ground floors and paving (un-reinforced) not exceeding 15cm. thickness, below or above ground level, complete and removing rubbish from the site, complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for and removing rubbish from the site, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed.
25mm thick PCC 1:2:4, type B-0 (using 12.50mm graded crushed stone aggregate) as in sub-base, finished even and fair, to receive tiles, complete all as specified and as directed.
Non-skid coloured ceramic tiles of any shade and any pattern of size (Pattern consists combination of two or more tiles) 300mm x 300mm x 7mm thick, over and including 15mm thick screed bed in CM 1:4 as in floors etc. jointed in neat cement slurry and pointed in coloured cement to match coloured tiles, complete all as specified and directed.
Glazed ceramic coloured wall tiles in any type and in any pattern (Pattern consist of combination two or more diffrent colour tiles etc.) in vertical surfaces of size 450mm x 300mm x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick backing coat in CM 1:4, finished fair to received the tile, complete all as specified and directed.
Non-skid coloured ceramic tiles of any shade and any pattern of size (Pattern consists combination of two or more tiles) 400mm x 400mm x 7mm thick, over and including 15mm thick screed bed in CM 1:4 as in floors etc. jointed in neat cement slurry and pointed in coloured cement to match coloured tiles, complete all as specified and directed.
18mm to 20mm thick of size not less than 53 x 53cm, machine cut Kota stone slab flooring laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror finish polishing, over and including 15mm thick screed bed or bedding layer of cement mortar 1:4 all as specified and as directed.
16mm to 18mm thick, machine cut Kota stone as in riser or steps, skirting, dado and pillars laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and rounding off edges complete with mirror finish polishing, over and including 15mm thick screed bed or bedding layer of cement mortar 1:3 all as specified and as directed.
18-20 mm thick Granite stone (table rubbed and polished) in steps, risers, jambs, pillars, window cills, cooking platform bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone over and including 15mm thick screed bed in cement mortar 1:4 finished fair to received the granite including rounding the exposed edges, complete all as specified and directed.
Factory made precast concrete designer paver tiles any colour, shape and size not less then 300mm x 300mm x 10mm thickness (Pavigres of Kajaria or Durastone of Somany or equivalent in design and pattern as approved by GE, set, jointed and pointed in neat cement slurry in floor or path with grey cement and pigment over and including 15mm thick CM 1:6 screed bed or bedding layer complete all as specified and directed.
Taking down chowkhats with shutters (without taking off shutter from the frames) not exceeding 1.50 Sqm each, removing from site and making good the disturbed surfaces with cement sand mortar complete all as specified and directed.
Taking down chowkhats with shutters (without taking off shutter from the frames) exceeding 1.50 Sqm and not exceeding 4.00 Sqm each, removing from site and making good the disturbed surfaces with cement sand mortar complete all as specified and directed.
Pressed steel frame for door with one or more rebates including necessary lugs, fixing lugs hinges, lock strike plate etc. of size 125mm x 60 mm and made of 1.25mm thick MS sheet, complete all as specified and directed including necessary welding complete and including medium weight 03 Nos of MS butt hinges of size 75mm / 100mm / 125mm and 01 No 50mm Size of medium weight MS butt hinge complete all as specified and directed.
PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in back filling of pressed steel door frames and in bed block for holdfast and similar works etc. complete all as specified and directed.
35mm thick 2nd class Hard wood factory made rail and style plain framed, panelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed.
35mm thick, 2nd Class hard wood, factory made, glazed and skeleton shutters open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats, complete all as specified and as directed.
Box type steel windows comprising of tubular frame and shutters made out of 1.25mm thick MS steel tube, factory made, with double side shutters wire gauged shutter and glass glazed shutter (wire and glass panes shall be measured and paid separately) with side hung shutters with steel handle and steel peg stay dovetailed or welded including 2 Nos tower bolts 150 mm long for each leaf and 8mm square bar grills at spacing as shown on drg welded to F1 frame work, including other fittings, hinges, handles tarred hold fasts PCC blocks etc all as shown on Drawing No CEPZ/TD-354/09 sheet 1/3 to 3/3 including taking down old steel window of any size complete all as specified and directed.
Steel ventilator with side hung double shutters (Ventilator consisting of one shutter out side and one shutter of similar dimension inside of single Mild Steel frame ) including hinges with steel handle of 100mm and steel peg stay complete with glazig bars, and including MS guard bars and grills made out of 10mm MS square bars, lugs as in hold fast with locking arrangements, complete all as specified and directed.
Steel ventilator with top hung shutter including hinges, steel peg stay, lugs as in hold fast with locking arrangements, complete all as specified and directed.
Factory made solid panel PVC door/cup board shutter 30mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails M.S frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement or stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail. Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame at site as per specification in SSR Part-I.
18/19mm thick Prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination, fixed with screws to timber frame work with ovar board or partical board for external 6mm thick teak wood lipping as in cupboards, kitchen cabinets etc., complete all as specified and directed.
Extra over rates of block board or veneered particle board for external teak wood lipping 6mm thick fixed with nails complete all as specified and directed.
Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) 300mm, and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
Steel locking bolt with mild steel electro galvanised plate and bright bolt not less than 10mm dia and 100mm long complete all as specified and directed.
Butt hinges, medium weight, cold rolled mild steel, 100mm size, complete all as specified and directed.
Butt hinges, medium weight, cold rolled mild steel, 75mm size, complete all as specified and directed.
Aluminium anodized barrel tower bolt of extruded section and fixed complete of Size 150mm long complete all as specified and directed.
Aluminium handle cast type anodized of size 150mm complete all as specified and directed.
Floor door stopper of length of cover plate 150mm of aluminium alloy body and tongue, aodized, with hard drawn steel spring complete all as specified and as directed.
Extruded Aluminium alloy handle fabricated type anodized of size 100mm complete all as specified and directed.
Magnetic catches of size 25/30mm for cup board shutter etc complete all as specified and directed.
Hasp and staple, safety type, 100mm, brass with hinge pin including bolt to hinge plate and fixed with screws, complete all as specified and directed.
2nd class hard wood fillets, square or rectangular in section, wrought, sectional area exc 13 sqcm but not exc 25 sqcm complete all as specified and directed.
Mild Steel ordinary rat tail rod pattern springs including roller and roller plate of 300mm size, fixed in repair complete all as specified and as directed.
3.00mm thick sheet glass ordinary quality and glazing with oil putty / screws, in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
3mm thick figured glass, pin head type and glazing with oil putty or wooden beads in square not exceeding 0.5 Sqm each complete all as specified and directed.
Galvanised steel wire cloth 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tank or galvanized wire staple complete, all as specified and as directed.
Complete removal of the existing roof treatment including grubbing up of tree roots and Preparation of the concrete roof surfaces by scrubbing down with steel brushes and cleaning with water all loose dirt/dust and applying the following Roof Treatment complete all as directed :- (a) Applying 1st course of 15mm thick screed bed with cement mortar 1:4 over concrete surface. (b) Applying 2nd course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 3rd coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
(d) Applying 4th course of APP (Atactic Polypropylene) modified polymeric membrane 3 mm thick weight not less than 3.6 Kilogram/Square Metre with 160 Grams/Square Metre non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat. (e) Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kilogram/Square Metre. (f) Applying two coats of aluminium paint over APP membrane complete all as specified and as directed.
Taking down cement plaster and decayed concrete of any description, upto triple storey of building, from roof projection, chajjas etc and making good the decayed portion with cement mortar 1:3 mixed with water proofing compound (as per manufacturer instruction) or mixed with WPC or PCC 1:2:4 type B-0 (using 12.5mm graded aggregate) including necessary form work, fixing of GI wire netting 0.90mm dia and 12mm mesh in patches area n.exc 3.00 Sqm where ever required and finally finishing the surface with 15 mm thick cement plaster in CM 1:3 and applying two coats of white wash/colour wash/cement base paint / exterior emulsion paint to match the existing surface /finish, complete all as specified and as directed. Note : Water proofing compound shall shall be measured and paid seprately.
Dismantling of asbestos cement sheets corrugated or semi corrugated etc. in roof covering including ridge complete and set aside, complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating G.I based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in roof covering, fixed with self taping screws, complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating G.I based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in ridges, fixed with self taping screws, complete all as specified and directed.
4mm thick ceiling board fixed with screws as per manufacturers instructions as in false ceiling fixed on and including hot dipped galvanised iron imposed grid with 24mm wide ‘T’ section, imposed flanges which shall be under coated white. The frame shall comprise of main runner made from 0.33mm thick galvanised steel sheet and size of 24 x 32 x 300mm and spaced at 12mm centre securely fixed to the structural soffits by approved hangers at 1200mm maximum centres hangers of GI wire 4mm dia to be fixed by the approved rawl plug, level adjusters and screws etc. The last hanger at the end of each runner shall not be greater than 450mm from adjacent wall flush fitting of 1200mm long cross Tee with double stiching to be inter locked between main runners at 600 mm centre to from 1200 x 600 mm modules cross Tee longer than 600mm modules to be formed by fitting 600 mm long cross Tee. The Tee perimeter wall angle shall be of 0.45mm thick galvanised steel of size 19 x 19mm and 300 mm long of white colour all as per the manufacturers instructions complete all as specified and directed.
Dismantling of timber scantling 40 sqcm and over in section and any position in framed work complete all as specified and directed.
Dismantling of wrought iron or Mild steel work of any description not otherwise provided for complete all as specified and directed.
Mild steel framed work such as gate grills, gratings, framed guard bars; angle iron, plate etc., and similar work including pintle hinges, stops, welding, rivetting, bolting, hold fasts, sliding bolt, and other necessary fittings conforming to Fe 410-O or Gde-Fe-310-O, complete all as specified and as directed.
Mild steel plates (plain or chequered) channel, square cut or notched (Ordinary and counter sunk) forming holes, without any attachment as in gusset plates conforming to grade FE.-410-S, complete all as specified and directed.
Mild steel rolled work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (beam, tee, angle, square / rectangle sections, channel or flat section) including distance pieces, cleats etc. confirming to grade FE 410-W (Gde E-250, Quality-A) complete all as specified and directed.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed the bothe ends, each screwed end to be fitted with washers and one hexagonal or square nut, 12 to 20mm dia but length of bolt exceeding 30cm and not exceeding 60cm complete all as specified and directed.
Barbed razor tape concertina coil, SG hot dip galvanised spring tensile wire, dia of coil when stretched 600mm having minimum 10 number of circles per running metre, minimum 15 clips per running metre and minimum weight of coil 0.96 Kg/RM complete all as specified and as directed.
Rolled Mild Steel in angle iron post and strusts / double swan neck horn on security wall including securing bolt, including cutting top to shape, notching for wires etc. including all necessary drilling, bolting or rivetting as required confirming to FE-290 Gde-E-165 complete all as specified and directed.
Galvanised, 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provn of galvanised mild steel wire, staples or steel pins, etc as directed.
Dismantling RCC /PVC water tanks exceeding 500 ltr capacity but not exceeding 1000ltrs complete all as specified and directed.
Rotational moulded polyethylene water storage tanks tripple layer (cylindrical vertical with closed top) hoisted and fixed in position, including over flow and drain out pipe complete of 1000 litre capacity complete all as specified and directed.
Rotational moulded polyethylene water storage tanks tripple layer (cylindrical vertical with closed top) hoisted and fixed in position, including over flow and drain out pipe complete of 500 litre capacity complete all as specified and directed.
Ball brass valves high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed to 20mm bore dia of pipe (Minimum weight 210gms) complete all as specified and directed.
Gun metal globe or gate valve with iron wheel heads, screwed both ends for 20mm dia bore iron pipe complete all as specified and directed.
Gun metal globe or gate valve with iron wheel heads, screwed both ends for 25mm dia bore iron pipe complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connection including cleaning for re-fixing or removal to store complete all as specified and as directed.
Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 15mm, complete all as specified and as directed.
Taking up or down 20mm bore steel tubing and connection including cleaning for re-fixing or removal to store complete all as specified and as directed.
Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 20mm, complete all as specified and as directed.
Vitreous china Orissa pan of pattern, long pan size 580mm x 440mm, with ‘P’ or ‘S’ trap, front or back inlet and integral foot rest complete including lime concrete bedding and connection to drain or outgoing pipe and to flushing pipe, and anti siphon pipe, fixed in repairs complete all as specified and directed.
10 litres capacity PVC low level flush cistern of approved make complete with PVC flush pipe and connection to water closet fixed in repairs complete all as specified and directed.
PVC connection 45cm long fitted with PTMT nut and washer on both ends, fixed to 15mm bore iron pipes, complete all as specified and directed.
PVC connection 60cm long fitted with PTMT nut and washer on both ends, fixed to 15mm bore iron pipes, complete all as specified and directed.
Vitreous china coloured urinal with cartridge Half stall flat back (Large ) of size 635mm x 395mmx 420mm complete with all accessories including CP spreader, PVC connection and waste pipe etc. complete all as specified and as directed.
15mm thick marble stone (table rubbed and polished ) fixed for urinal partition complete all as specified and directed.
Mild steel framed brackets of angle iron, cut to shape, including bedding and welding complete as in stay of marble stone partition wall complete all as directed.
Vitreous china wash hand basin white, flat back of size 580mm x 450mm including cutting for and pinning in ends of brackets or eracting stand, fixed in repair, complete all as specified and as directed.
Vitreous china wash hand basin with pedestal, oval shape, coloured, size 520mm x 400mm fixed in black granite stone slab, including cutting of size in granite, moulding of edges, including 32mm bore brass chromium plated waste coupling with long screwed shank and fly nuts, PVC flexible waste pipe of bore 32mm and adequate length, 15mm bore PVC connection pipe 450mm long with brass nuts on both side, complete all as specified and as directed.
Towel rail, brass chromium plated, 20 mm dia, D type, 60 cm long between hinges, complete all as specified and directed.
Grating doom 100mm dia with or without waste hole of PTMT (minimum weight 40 Gm ) complete all as specified and directed.
Bib tap cast copper alloy chromium plated, with capstan headed handle, screwed down, screwed for 15mm bore iron pipe or for brass ferrule complete all as specified and directed.
Angle valve CP cast copper alloy, fancy type, with capstan head handle, screwed down, high pressure screwed both ends for 15mm bore iron pipe or for unions complete all as specified and directed.
Stop valve /angle valve cast copper alloy with crutch or butterfly handle, screwed down, high pressure screwed both ends for 15mm bore iron pipe or for unions complete all as specified and directed.
Stop valve cast copper alloy with crutch or butterfly handle, screwed down, high pressure screwed both ends for 20mm bore iron pipe or for unions complete all as specified and directed.
Stop valve chromium plated fancy type cast copper alloy with long shank and cup (concealed type) screwed down, high pressure with capstan headed handle, screwed both ends for iron pipe or for unions of 15mm bore fixed in repair complete all as specified and as directed.
Stop valve chromium plated fancy type cast copper alloy with long shank and cup screwed down, high pressure with capstan headed handle, screwed both ends for iron pipe or for unions of 15mm bore fixed in repair complete all as specified and as directed.
Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, long screwed for iron pipe 15mm bore and fixed in repair complete all as specified and directed.
25 mm dia curtain rod, chromium plated with fixing brackets stop rollers complete, all as specified and as directed.
Cutting chases in brick wall, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting not exceeding 20cm girth complete, all as specified and as directed.
PVC (SWR) pipes 110mm single socketed, in any length with rubber ring joints, laid in trenches or floors complete all as specified and directed.
PVC (SWR) pipes 75mm single socketed, in any length with rubber ring joints, laid in trenches or floors complete all as specified and directed.
PVC (SWR) bends 110mm, complete all as specified and directed.
PVC (SWR) bends 75mm, complete all as specified and directed.
PVC (SWR) vent cowl 110mm, complete all as specified and directed.
PVC (SWR) vent cowl 75mm, complete all as specified and directed.
PVC (SWR) Junction (Single T) equal or unequal 110mm, complete all as specified and directed.
PVC (SWR) Reducer 110mm, larger bore measured complete all as specified and directed.
PVC (SWR) Reducer 75mm, larger bore measured complete all as specified and directed.
40mm dia PVC pipe including bend, Tee etc complete all as specified and directed.
PVC (SWR) floor trap 75mm dia with CP grating including jointing to waste fixed in PCC (1:2:4) type B-1 complete all as specified and directed.
Salt glazed stone ware (SGSW) drain pipes of grade 'A' 150mm bore laid in trenches and jointed on concrete bed complete all as specified and directed.
Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested, for 150mm bore of pipe plain cement concrete 1:3:6 type C-2 (Using 40mm graded stone aggregates) complete all as specified and directed.
Construction of Septic Tank for 10 users including excavation in any type of soil, foundation in PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) brick work in cement mortar 1:4, RCC (M-25 design Mix) slab including cast iron manhole cover having 6mm plate embedded all around with angle iron frame vent shaft etc, complete all as specified and shown on CE Pathankot Zone TD Drawing No CEPZ/C-TD/013/13 Sheet 1 to 5.
Precast cement concrete 1:2:4, type B-1 (Using 20 mm graded crushed stone aggregate) in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:4 including necessary form work, complete, all as specified and as directed.
Preparation of new or previously untreated wall surfaces and applying three coats of white wash, complete all as specified and directed.
Preparation of old or previously treated wall surfaces and applying one coat of white wash, complete all as specified and directed.
Preparation of new or previously untreated ceiling surfaces and applying three coats of white wash, complete all as specified and directed.
Preparation of old or previously treated ceiling surfaces and applying one coat of white wash, complete all as specified and directed.
Preparation new plastered surfaces of wall and applying two coats of oil emulsion distemper over a coat of chalk whitening primer coat complete all as specified and as directed.
Preparation of new or previously untreated ceiling surfaces and applying two coats of oil bound distamper, complete all as specified and directed.
Preparation of old plastered or unplastered surfaces of wall and applying one coat of cement base paint complete all as specified and directed.
Preparation of new plastered external surfaces of wall and applying two coats of cement base paint including one coat of cement primer completeall as specified and directed.
Complete removal of existing treatment from external wall surface including preparation of old plastered external surfaces of wall and applying two coats of cement base paint including one coat of cement primer complete all as specified and directed.
Complete removal of existing treatment including preparation of old plastered external surfaces of wall and applying two coats of oil bound distamper over a coat of wall care putty (Birla/JK) of average thickness 2 to 3mm complete all as specified and directed.
Preparation new plastered surfaces of wall and applying two coats of oil emulsion distemper roller finish over a coat of alkali resistant primer coat over and including a coat of wall care putty (Birla/JK) of average thickness 2 to 3mm complete all as specified and as directed.
Preparation of new wooden surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed.
Preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and as directed.
Preparation of old steel surfaces of any description, over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed.
E/M Portion
Taking out carefully copper/aluminium point wiring, (Light, fan, socket or power) complete with all fitting, fixtures such as switch socket out let, ceiling rose, holder, regulator, DB's etc. including making good the disturbed surface of wall/floors, complete all as specified and as directed.
Taking down distribution board / wooden board, switch fuse units, steel enclosures for MCB of any type and removing from site complete all as specified and as directed.
Point wiring with multi stranded copper conductor of size 1.5Sqmm PVC insulated unsheathed FRLS cable in and including PVC conduit and accessories of suitable size for concealed wiring including 1.50 Sqmm copper earth wire (green colour) FRLS Cable for one light point or fan point or bell point controlled by one No, one way switch using cable of different insulation colour for colour coding including 3mm thick laminated sheet cover, mild steel sheet or cast iron boxes including cutting chases and making good to disturbed surfaces of wall / floor, complete all as specified and as directed.
All as per the description of Serial Item No 148 here-in-before but for one 3 pin socket outlet 5 Amp independent, complete all as specified and as directed.
All as per the description of Serial Item No 148 here-in-before but for one 3 pin socket outlet 5 Amp on the same board, complete all as specified and as directed.
All as per the description of Serial Item No 148 here-in-before but for one 3 pin socket outlet 15 Amp independent board using cable of size 4.0 Sqmm conduit all as specified and directed.
Switch piano flush type single pole, one way 5 Amp, complete all as specified and as directed.
Switch socket outlet combination universal type, 2 in 1, 3 pin 5 and 15 Amp, piano flush type, 240 volts, complete all as specified and as directed.
Switch socket out let combination universal type, 2 in 1, 2 and 3 pin 5 Amp, piano flush type, 240 volts, complete all as specified and as directed.
Ceiling rose surface bakelite three terminals 240 volts complete all as specified and as directed.
Lamp holder PVC case body of Bakelite with back plate suitable for batten fittings with and including Inverter LED lamp, 6500K, 900lm in white colour of 9 Watt base cap B-22 with poly carbonate diffuser and aluminium heat sink, complete all as specified and as directed.
Supply, Installation, Testing and commissioning of 1200mm sweep 230 Volts AC Ceiling Fan, two star BEE rating confirming to IS : 374 of 2019, 3 Blade along with copper wound stator (Capacitor start), with minimum air delivery 210 Cubic metre per minute, power consumption not more than 50 Watt, Top Speed min 370 RPM, aluminium blades, capacitor, down rod, canopy etc as required including making connection with three core 1.5Sqmm flexible copper cable upto ceiling rose complete including taking down old unserviceable fan of any type / size from existing location and deposited in MES store yard complete all as specified and as directed. Make : Havells / CG/ Usha/ Bajaj.
Exhaust Fan, Metal Body, 450mm sweep, single phase, 230 volts 50 Hz AC, 1400 RPM, energy saving 3 star rated, heavy duty totally enclosed, heavy duty motor with die-cast aluminiun rotor mounted on two ball bearings complete with louvers and shutters including cutting hole for fixing exhaust fan to wall and making good the disturbed surfaces (including plastering, necessary brickwork and distempering) to match with the existing specification, connecting electrically using 3 core 0.75 Sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site and as directed. Make : Havells model : Turbo force SP/ Usha Model No. 300 S.PH Turbo HDEF900RPM ISI GREY.
Supply and fixing of storage water heater (Geyser), vertical type, of 25 ltr capacity of inner tank, outer tank, syphon assembly, thermostat heating element, safety valve etc complete all as per manufacturer design and specifications including making of all fixing arrangements complete having BEE Five Star Rating including grouting of nuts and bolts and necessary PCC work as specified and directed by Engineer-in-Charge. Make : HAVELLS Model No. : Monza DX Cat Part No.GHWAMGSIH025 or equivalent model of make as per list of make in particular specifications.
Cutting existing Steel tubing 15mm bore for alteration or additions (Each cut measured).
Screwing existing Steel tubing 15mm bore for alteration or additions.
Road cutting including PCC hardstanding, excavation etc for laying of GI pipe and making good the disturbed surfaces complete all as specified and as directed.
Electronic fan regulator stepped type with five step 240 volts 100 watt suitable for 1200mm / 1400mm sweep AC ceiling fan complete all as specified and as directed.
Tube light fitting integrated type including LED 20 Watt tube rod 4' long, indoor decorative LED extruded aluminium batten in anodised finish with opal diffuser, IP-20 complete with housing and all accessories pre wired and making connections with three core copper flexible cable of size 23 / 0.0076 from ceiling rose to PVC connector to light fitting complete all as specified and as directed. Make : Crompton Greaves Model Bright Linea, CAT No. CCS-100-20-65-HL2-DP-NWH / Philips Cat Part No. BN021CLED20SPSUCWGRS2 / C & S CAT No. LTTB4F20WLED/W /Havells CAT No. LUMILINEPLUSBS20WLED865SPCSS.
MCB DP 6 to 32 Amp, 240 volts 50Hz,10 KA AC supply, complete all as specified and as directed.
MCB SP 6 to 32 Amp 10 KA, complete all as specified and as directed.
Sheet metal enclosure factory made double door, IP-43 for DB 240 volts (Where MCBs are required) SPN 2Way, complete all as specified and as directed.
Factory made epoxy powder coated Distribution board SPN 12 ways (SPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 100 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one SPN/DP-MCB as incomer and SP MCBs outgoing complete all as specified and confirming to IS : 8623. Make: Legrand Cat No. 507622/ Schneider Cat No. A9HSND12 / C&S Cat No. CSDBSPNDDA2+12 or equivalent model of ABB.
Factory made epoxy powder coated Distribution board vertical TPN 8 ways (TPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one FP-MCCB 160/250 Amp as incomer and SP/TP MCBs outgoing complete all as specified and confirming to IS : 8623. Make: C&S, Cat No. CSDBMCCB100DD08IP43S /Schneider A9HVD08L or equivalent model of GE power/Legrand/ ABB.
Single Pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole 20 Amp and 240 Volts, 10 KA, C series MCB complete all as specified and as directed.
Thermal magnetic release MCCB, 4 Pole, 415 Volts, 63 Amp, 25 KA, complete all as specified and as directed. C&S CAT No. CS2B4C63 or equivalent from the list of make.
On load change over switch in sheet metal enclosure, 63 Amps, four pole, modular type, positive isolation, door interlock and padlock facility confirming to IS/IEC 60947-3, complete all as specified & directed. Make. C&S Cat Part No. ECSCS63NM4CO (NM SERIES) or equivalent of SCHNEIDER /SIEMENS/ ABB.
Integral LED Security Light luminaire 60 Watt, 230 Volts made of pressure die-cast aluminium housing with high power LED lens and toughened glass and electronic driver IP-66 including GI 40mm mounting brscket bent to shape (weld free) 1.7 metre in length fixed on wall /pole with necessary MS clamp, nuts and bolts and making connection with PVC copper flexible cable 1.5sqmm complete all as specified and directed. Make : Philips Cat No. BRP410LEDCW069NRFGS1PSUGR /Crompton Greaves Cat Part No LSTP-60-CDL-M / C&S Cart Part No. LTESS60WLED/LS/Havells cat No. ENDURAPEARLNEOSL60WLED757PASYTOPC.
Excavating in trenches in any type of soil, not exceeding 1.5m wide and not exceeding 1.5m in depth for electric poles / stay foundation and under ground electric power cables, CI /GI pipes etc and getting out, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed.
Removing excavated surplus material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 10 Sqmm 2 core, including glands, lugs, nut, bolts washers as required at site and testing complete all as specified and directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 2 core, including glands, lugs, nut, bolts washers as required at site and testing complete all as specified and directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 4 core, including glands, lugs, nut, bolts washers as required at site and testing complete all as specified and directed.
Supply and laying brick covering with width equal to length of bricks as mechanical protection to underground cable using old size sub class 'B' bricks, laid flat size 230mm x 115mm x 75 mm, all as specified and as directed.
Sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches complete, all as specified and as directed. Note : The punned thickness 18cm shall be considered for measurement purpose.
Steel pipe galvanised medium grade, 40 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor /trenches complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 25mm, complete all as specified and as directed.
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 3 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on completion.
M/s Des Raj and Sons
KAMAL CONSTRUCTION
ASHOK KUMAR
Kanwal Nain Behl
Bidder Name
Kanwal Nain Behl
M/S Sudagar Mal
KAMAL CONSTRUCTION
ASHOK KUMAR
M/s Des Raj and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .