Loading…
Loading…
Tender Value
₹8.3 L
EMD Value
₹16,600
Closing Date
16 Oct 2026, 6:00 pm
AGE (I) Naya Raipur
AGE (I) Naya Raipur, Military Engineer Services, C/O HQ COSA, Near International Cricket Stadium, Atal Nagar, Raipur (CG) 492101
As per BOQ
2026_MES_791198_1
8400/466/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) Naya Raipur
As per NIT
7 documents required · 7 mandatory
₹500
AGE (I) Naya Raipur
₹16,600
25 Sept 2026
25 Sept 2026
19 Oct 2026
25 Sept 2026
16 Oct 2026
9 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | S & F in replacemnet of MCB DB's 4 Way TPN, 415 volts for mounting MCBs/RCBO's ELCB's etc. as per IS specification of factory made fabricated out of CRCA sheet 1.2 mm thick powder coated fitted with DIN Channel neutral link and 200 Amps rated bus bar.The DB's shall double door type . Inner door fixed on spring loaded hinges with locking arrangement & outer door openable hinged with locking arrangement having IP-43 protection. | 2 | Each | - | - |
| 2 | S & F in replacement of MCB DB's 8 Way SPN, 240 volts for mounting MCBs/RCBO's ELCB's etc. as per IS specification of factory made fabricated out of CRCA sheet 1.2 mm thick powder coated fitted with DIN Channel neutral link and 200 Amps rated bus bar.The DB's shall double door type . Inner door fixed on spring loaded hinges with locking arrangement & outer door openable hinged with locking arrangement having IP-43 protection. | 4 | Each | - | - |
| 3 | Supply and fixing in replacement of 415V 10KA 'C' curve MCB of 40-100 Amps TPN/4P and current carrying capacity in the DB complete with connection testing and commissioning. | - | Each | - | - |
| 4 | S & F in replacement of MCB SPN 63 Amps 240 Volts C Curve 10 KA | 4 | Each | - | - |
| 5 | S & F in replacement of MCB SP 32 Amps 240 Volts C Curve 10 KA | - | Each | - | - |
| 6 | M&L for taking down old unsv submain wiring from existing places/ wall complete all as specified and directed by Engr-in-Charge. | - | RM | - | - |
| 7 | M&L in replacement of Sub main wiring with approved colour coding as per IS with two runs of single core PVC insulated cable FRLS with Multi Strand copper conductor of size 6 Sq. mm and drawing into PVC conduit including one run of PVC insulated 6 sqmm stranded copper conductor earth wire complete all as directed. | 200 | RM | - | - |
| 8 | M&L in replacement of Sub main wiring with approved colour coding as per IS with two runs of single core PVC insulated cable FRLS with Multi Strand copper conductor of size 4 Sq. mm and drawing into PVC conduit including one run of PVC insulated 4 sqmm stranded copper conductor earth wire complete all as directed. | 400 | RM | - | - |
| 9 | M&L in replacement of Earthing complete with galvanised steel earth plate electrode of size 60cm X 60cm X 6mm buried directly in ground (earth pit not less than 2.25 metres deep below the normal ground level) with top edge of the plate not less than 1.5m below normal GL connected to GI earth wire 4 mm dia by means of GI bolts, nuts, check nuts and washers and earth strip protected by 25 mm dia GI pipe medium grade and connected to main distribution board/earthing test point all as shown on electrical plate No.3 of SSR Part I and all as specified including testing on completion.Notes: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix, type B1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe for earth lead upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II and also refer Plate No-03. Earth strip and protection pipe beyond 7.5m shall be measured and paid separately. Note :- Earthing will be redone if desied erath result not found during testing of the same at site. | 1 | Each Set | - | - |
| 10 | Supplying, installing, testing and commissioning indoore type cubical LT control panel in replacement, suitable for 3 phase, 4 wire, 415 volts, 50 Hz and CPRI approved, factory made in an approved factory , panel with suitable gasket to make it dust / vermin proof & general construction confirming to IS:8623 / 93, compartmentalized cubical indoor type with compartments for each out going and incoming feeders of suitable size, made of 2 mm thick CRCA sheet painted with one coat of epoxy based powder coating with wall mounting arrengement and double hinged front openable shutters of each feeder control unit with locking arrangement in front, PVC sleeved electrolyte copper bus bar with Tin Coating of 400 Amps capacity for each phases and neutral fixed on suitable insulator all housed in suitable bus bar chamber along with provision of necessary cable entry/exit boxes fixed on suitable PCC foundations and comprising of following items:-
(a) 160 Amps 4P, 36KA MCCB - 02 Nos
(b) 100 Amp 4P, 16KA MCCB & ROH - 02 No
(c) 63 Amp 4P, 16KA MCB TPN - 05 No
(d) 125 Amp ATS 4P - 01 No.
(e) Multifunction Meter - 01 No
(f) Digital 0-500V Volt Meter - 01 No
(g) Digital 0-500A Ammeter - 01 No
(h) Selector switch for V/A meter - 02 No
(j) R Y B Phase Indication Lamps - 03 Nos
(k) CTs 400/5A, 15VA, CL-1 - 03 Nos
(l) Panel internal control wiring using PVC copper flexible in duct of suitable size - 01 Job | 1 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.18 MB
TenderPage466.pdf
Tender Documents • 1.06 MB
BOQ_887012.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .