Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹44.6 L
EMD Value
₹89,160
Closing Date
5 Nov 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (South) Meerut Cantt
SPL REPAIR TO BLDG NO E-09 AT 309 FD HOSP, ADDL/ALTN TO PARKING SHED AT DADS OFFICE AND BLDG NO P-309 AT 289 FD WKSP COY UNDER AGE AGE B/R-III AND AGE E/M-II OF GE (SOUTH) MEERUT CANTT
SPL REPAIR TO BLDG NO E-09 AT 309 FD HOSP, ADDL/ALTN TO PARKING SHED AT DADS OFFICE AND BLDG NO P-309 AT 289 FD WKSP COY UNDER AGE AGE B/R-III AND AGE E/M-II OF GE (SOUTH) MEERUT CANTT
2025_MES_733148_1
GE/MRT/S/8273/2025-2026
Open Tender
Civil Works
Item Rate
180 days
Meerut Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (South) Meerut
₹89,160
Yes
Garrison Engineer (South) Meerut Cantt
30 Sept 2025
30 Sept 2025
12 Nov 2025
30 Sept 2025
5 Nov 2025
17 Oct 2025
10 Oct 2025
Demolition of brick work or stone/boulder masonary built in cement mortar incl all quoins arches pillars etc complete all as specified & directed.
M&L Brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified & directed.
M&L Brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 except bricks complete all as specified & directed.
M&L 75 mm thick cement concrete 1:4:8 type D-2 using (40 mm graded stone agg) as in sub base complete all as specified & directed.
Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified & directed.
M&L 75 mm thick cement concrete type C-2, 1:3:6 (40 mm graded aggregate) finished even and smooth without using extra cement as in plinth protection complete all as specified & directed.
Supply and fixing made plain framed panelled shutter 35mm thick with lock rail and panel of 9mm BWP commercial ply or 12mm venered particle board with commercial veneering on both faces, the size of rail at stile as per IS: 1003 Pt-I kiln seasoned and chemically pressure treated complete all as specified
Supply and fixing for 35mm thick glazed and skeleton shutters of 2nd class hardwood open nebated and prepaired to receive glass gauge etc, (with sash bars) edgeg of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc. size of member of shutter as specified in SSR Pt-I section 8 clause 8.20(a) complete all as specified and directed
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) or insulation boards / slabs / blankets any thickness including cover fillets complete all as specified & directed.
S&F GI snap grid frame work of size 605 x 605 mm, for false ceiling comprising 40 x 25 x 2mm GI angles weight 0.36 kg fixed all along the wall at ends and with GI main and cross tee of size 36.50 mm x 25 mm x 1.4 mm width not less than 0.24 kg per RM including GI cleat bolts nuts and washers and 4mm dia GI wire suspenders in alternates panel and preparing holes / chases in wall for fixing angle including supply & fixing suitable non asbestos fibre cement boards in ceiling of size 600 mm x 600 mm complete as per approved make complete all as specified & directed.
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified & directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & directed.
Dismantling timber scantiling 40 Sqcm and over in section in any position complete all as specified and directed.
S&F structural steel work as in roof truss/purlin/rafter/post or simillar work, made of tubular/angular(equal/unequal angles/ISMB section/plates as per site requirement) including welding, special shaped washers etc. using ERW or induction butt welded tubes conforming to I.S 1161-1979 gde St-240 complete all as specified and directed.
M&L for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, Fe 410-W (Gde-E-250) quality A without any attachment complete all as specified and directed.
M&L for 5-6mm dia GI wire, fixed with 10mm dia round MS bar, including suitable hooking & Nut/washers at either end, fixing/grounting/inserting in wall for fixing of mosquito net complete all as specified & directed.
Taking down of cement plaster of any description from brick or stone wall etc. including raking out of joints, hacking for key, scrubbing down with water etc complete all as specified & directed.
M & L 15 mm thick rendering in CM 1:6 on fair faces of brick or concrete surfaces finished even and fair complete all as specified & directed.
Preparation of old plastered or unplastered surfaces including sraping/removing of existing/old treatment of wall, applying 2mm thick wall care putty, mak
Preparation of New plastered or unplastered surfaces of wall and applying applying 2mm thick wall care putty, making the surface smooth and applying two coat of oil emulsion distemper using roller complete all as specified & directed.
M&L applying two coats of exterior emulson paint (weather proof) on plastered or unplastered surfaces, using roller over and including applying 2mm thick putty after preparation & scraping the wall surfaces complete all as specified and directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding but not backing and removing rubbish off the premises complete all as specified & directed.
M&L for 18 to 20 mm thick black granite factory made bull nosed, polished (table rubbed and polished) as in jambs, window cills, cooking platform and the like etc in cement mortar 1:4 including pointing in white cement (1:2) using marble dust and admixture of pigment to match with shade of stone including rubbing and polishing over and including 10 mm thick rendering in cement mortar 1:4 including rounding of edges, making hole for gas pipe complete all as specified and directed.
Surface excavation Nexc (not exceeding) 30cm deep and averaging 15cm deep and geeting out in soft/loose soil complete all as specified & directed.
M&L hardcore (broken stone or boulders) of gauge nexc 63mm, deposited, spread and levelled in layers nexc 15cm thick, watered and rammed to a true surface complete all as specified & directed.
M&L 100mm thick PCC 1:3:6 type C-2 (using 40mm graded agg) as in sub-base complete all as specified & directed.
Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified & directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in & raming earth/ broken rubble mixed with earth around, in layers n. exc. 25cm, watering, & removing surplus soil to a distance n exc 50m & making good surface in soft/loose soil complete all as specified & directed.
Excavation in trenches not exc. 1.5 metre wide and not exc. 1.50 metre in depth for foundation etc and for manholes etc n.exc. 10 Sqm on plan and n.exc. 1.5 metre depth and getting out in soft/loose soil complete all as specified and directed.
Removing excavated materials (soils) to a distance not exc. 50 metre and depositing where directed at a level not exc. 1.50 above the starting point complete all as specified and directed.
Material & labour for 15 mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces, surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L applying two coats of exterior emulson paint (weather proof) on plastered or unplastered surfaces, using roller over and including applying 2mm thick putty after preparation & scraping the wall surfaces complete all as specified and directed.
Material & labour for 5 mm thick plaster in CM 1:3 on ceiling surfaces, surfaces finished even and smooth without using extra cement complete all as specified and directed.
S&F 200mm long, extruded aluminium alloy handles, fabricated type, anodised complete all as specified & directed.
Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.20Kg/Sqm including cleaning surface complete all as specified and directed.
M&L for cleaning of plastered /concrete surfaces and applying priming coat using bituminous primer @ 0.30 Kg/Sqm. followed by evenly a tack coat @ 1.20 Kg/Sqm. using with 85/25 grade bitumen, over laid with 3mm thick APP modified polymeric water proofing membrane with non woven polyester reinforced of weight not less than 3.6 Kg/Sqm. unrolled and bonded to substance with side and end laps 75mm and 100mm as per manufacturer’s instructions and finished top of APP water proofing polymeric membrane with a coat of hot blown industrial bitumen 85/25 grade @ 1.20 Kg/Sqm and finally finished with a coat of bituminous aluminium paint @ 0.20 Kg/Sqm complete all as specified and directed.
PVC (SWR), junction single, (Single T) equal or unequal any size mm bore complete all as specified & directed.
Provn of septic tanks, exc in ordinary soil foundation in PCC 1:2:4 brick work in CM 1:4 RCC Slab covers including RCC pre cost man hole cover having 6mm plate embeded all around/fire reinforced ever with angle iron frame vent shaft and sludge chambers etc of capacity 150 users complete all specified in drg No TD-217 sheet 1/7 to 7/7 and as directed by engr-in-charge.
Taking down carefully any type of battens or conduit point wiring with or except conduit (light, fan, socket or power) complete including fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, pendent light fittings, MCBs / isolators, fan regulators, tube light fittings etc removing material from site and making good disturbed surfaces of walls, ceilings etc including two coats of white / colour washing / distempering etc to match the existing complete all as specified & directed.
Per 1000 No's
Supply & fixing of socket outlet 3 pin, 05 / 06 Amps and 3 pin 15 / 16 Amps (2 in 1 Multipurpose) 240 volts complete all as specified & directed.
Material and labour for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, stranded, FRLS PVC insulated, unsheathed, copper conductor cable in and including new PVC concealed conduit of any size/dia complete with all accessories/fittings, brass screws, washer etc, sunk zinc coated pressed steel terminal boxes with 3mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated stranded copper conductor cable, unsheathed and connected to common earth and earth duly complete all as specified and directed for One light point controlled by one, one way switch 05 / 06 Amps.
Supply and fix in repair switch piano flush type, 05 / 06 Amps single pole, one way 240 voltscomplete all as specified & directed.
Supply and fix in repair switch piano flush type, 15 / 16 Amps single pole, one way 240 volts complete all as specified & directed.
Supply and fixing steped type electronic fan regulator flush type on the existing sheet etc. AC, 230 volts, duly ISI marked with and including connector complete all as specified & directed.
Supply & fixing lamp holder (Angular / Straight), insulated body, with back plate for batten fitting complete all as specified & directed.
S&F mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified & directed.
Supply and fix LED lamp 9/10 watt complete all as specified & directed.
Supply and fixing decorative LED tube light fitting/warm as directed 1x20 watt
surface mounting , intigrated with opal diffuser complete with all acessories complete all as specified & directed.
Supply and fixing sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 8 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting / chases on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces and taking down the old distribution board of any type complete all as specified & directed.
Supply and fixing Vertical Loadline sheet metal enclosure double door, Triple pole and neutral (TP&N vertical loadline) AC, 415 volts, 04 way, with 200 Amps rated copper bus bar and IP - 43 & IK 09 protection, with the inbuilt provison for fixing of 1 No MCCB of XT1160 frame suitable upto 160 Amp and 12 Nos MCB'S inside of DB, including 100 Amps ,18 KA 4 pole MCCB with metal door and flush to wall including grouting and cutting in existing wall and making good disturbed surface with two coats of white / colour washing / distempering etc to match the existing one complete all as specified & directed.
Supply and fixing MCB, SP, AC, 240 volts "B" series capacity of 06 to 32 Amps, 10kA and making connections complete all as specified & directed.
Supply & fixing MCB, DP (Double Pole), AC, 240 volts, B series capacity 40 Amps to 63 Amps 10kA and making connections complete all as specified & directed.
Material and labour for contineous brick edging with width equal to the depth of the brick of whole sub class 'B' bricks laid on edge complete all as specified and directed.
Supply and fixing in replacement ceiling fans complete with blades, down rods, electronic regulator and accessories, 230V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including taking down old unsv fan & will be deposited to AGE E/M-II (South) yard only
Taking down unsv cable of any type/size and S&F (in repair) , laying commissioning, testing of XLPE under ground LT cable 1100 volts grade of size 35 Sqmm 3.5 core armoured, PVC sheathed with aluminium conductor heavy duty laid in trenches, fixing on wall, under road crossing through protection pipe etc complete all as specified and directed.
M&L for washed river dry sand cushioning in trenches 80mm thick before laying the cable and 150mm thick after laying the cable including spreading levelling andhard punning complete all as specified & directed.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.05 MB
TenderdocumentsBR-EM.pdf
Tender Documents • 2.10 MB
BOQ_821096.xls
BOQ • 0.59 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .