Loading…
Loading…
Tender Value
₹43.6 L
EMD Value
₹88,000
Closing Date
7 Sept 2026, 6:00 pm
GARRISON ENGINEER JORHAT
GARRISON ENGINEER JORHAT
SPECIAL REPAIR TO LT PANEL AND OTHER CONNECTED ITEMS AT EM INSTALLATION UNDER JORHAT MIL STN
2026_MES_784903_1
8345/GE/E8
Open Tender
Civil Works
Item Rate
180 days
GE JORHAT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER JORHAT
₹88,000
Yes
18 Aug 2026
18 Aug 2026
8 Sept 2026
18 Aug 2026
7 Sept 2026
1 Sept 2026
18 Aug 2026 - 25 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, install, testing and commissioning as in replacement of cubical housing cabinet type CPRI approved Confirming to IP55 LT panel board outdoor type of size 0.80m x 0.80m x 0.40m, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15 mm thick CRCA MS Sheet and built upon suitable size MS angle iron frame work, having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synethetic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts, 50Hz, 3 phase 4 wire system and internal connection should be provided with aluminium strips of suitable size and necessary foundation work and comprising following:-
System Voltage-415V, 3-Ph, 4 wire, 50 HZ
Aluminium BUSBAR rating -400 Amps, cable entry (incomming and outgoing ) form bottom with cable gland
Incomming :-
(a) MCCB 4 Pole, 250 Amp, 36 KA - 01 Nos
(b) Digital voltmeter 0-500 volts with suitable PT and selector switch - 01 No
(c) Digital Amp meter 0-500 Amp with selector switch & suitable CT - 01 No
(d) Indicator lamp LBD type (RYB) complete with bakelite fuse fitting- 01 set
Outgoing -
(a) MCCB 160 A (Fixed Type),415 Volts 4 pole, 25 KA - 01 Nos
(b) MCCB 100 A (Fixed Type),415 Volts 4 pole, 18 KA - 01 No
(c) MCCB 63 A (Fixed Type),415 Volts 4 pole, 18 KA - 01 No | 8 | EACH | - | - |
| 2 | Supply , install, testing and commissioning as in replacement of cubical housing cabinet type CPRI approved LT panel board indoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 2.0 mm thick CRCA MS Sheet and built upon suitable size angle iron frame work , having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synethetic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts, 50Hz, 3 phase 4 wire system and internal connection should be provided with copper strips of suitable size and necessary foundation work and comprising following :-
System Voltage-415V, 3-Ph, 4 wire, 50 HZ
Aluminium BUSBAR rating -600 Amps, cable entry (incomming and outgoing ) form bottom with cable gland
Incomming :-
(a) MCCB 4 Pole, 400 Amp, 36 KA - 01 Nos
(b) Alum bus bar 500 Amp TPN - 01 Set
(c) Digital voltmeter 0-500 volts with suitable PT and selector switch - 01 No
(d) Digital Amp meter 0-500 Amp with selector switch & suitable CT - 01 No
(e) Indicator lamp LBD type (RYB) complete with bakelite fuse fitting- 01 set
Outgoing -
(a) MCCB 4 Pole, 320 Amp, 36 KA, - 01 Nos
(b) MCCB 4 Pole, 250 Amp, 36 KA, - 01 Nos
( c) MCCB 4 Pole, 160 Amp, 25 KA, - 01 Nos
(d) MCCB 4 Pole, 100 Amp, 25 KA, - 01 Nos
( e) MCCB 4 Pole, 63 Amp, 16KA, - 01 Nos | 6 | EACH | - | - |
| 3 | Supply, install, testing and commissioning as in replacement of cubical housing cabinet type CPRI approved Confirming to IP55 LT panel board outdoor type of size 0.80m x 0.80m x 0.40m, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15 mm thick CRCA MS Sheet and built upon suitable size MS angle iron frame work, having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synethetic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts, 50Hz, 3 phase 4 wire system and internal connection should be provided with aluminium strips of suitable size and necessary foundation work and comprising following:-
System Voltage-415V, 3-Ph, 4 wire, 50 HZ
Aluminium BUSBAR rating -500 Amps, cable entry incomming form bottom with cable gland
Incomming :
(a) MCCB 4 Pole, 320 Amp, 36 KA - 01 Nos
(c) Indicator lamp LBD type (RYB) complete with bakelite fuse fitting- 01 set | 6 | EACH | - | - |
| 4 | Supply , install, testing and commissioning as in replacement of cubical housing cabinet type CPRI approved Confirming to IP55 LT panel board outdoor type of size 0.80m x 0.80m x 0.40m, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15 mm thick CRCA MS Sheet and built upon suitable size MS angle iron frame work, having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synethetic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts, 50Hz, 3 phase 4 wire system and internal connection should be provided with aluminium strips of suitable size and necessary foundation work and comprising following:-
System Voltage-415V, 3-Ph, 4 wire, 50 HZ
Aluminium BUSBAR rating -400 Amps, cable entry incomming form bottom with cable gland
Incomming :-
(a) MCCB 4 Pole, 250 Amp, 36 KA - 01 Nos
(b) Indicator lamp LBD type (RYB) complete with bakelite fuse fitting- 01 set | 5 | EACH | - | - |
| 5 | Supply , install, testing and commissioning as in replacement of cubical housing cabinet type CPRI approved Confirming to IP55 LT panel board outdoor type of size 0.80m x 0.80m x 0.40m, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15 mm thick CRCA MS Sheet and built upon suitable size MS angle iron frame work, having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synethetic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts, 50Hz, 3 phase 4 wire system and internal connection should be provided with aluminium strips of suitable size and necessary foundation work and comprising following:-
System Voltage-415V, 3-Ph, 4 wire, 50 HZ
Aluminium BUSBAR rating -300 Amps, cable entry incomming form bottom with cable gland
Incomming :-
(a) MCCB 4 Pole, 160 Amp, 36 KA - 01 Nos
(c) Indicator lamp LBD type (RYB) complete with bakelite fuse fitting- 01 set | 5 | EACH | - | - |
| 6 | Supply and fixing as in replacement MCCB triple pole and neutral (Four pole) 400 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and fixed magnetic setting and breaking capacity 16 KA including making incoming and outgoing connections complete all as specified and as directed. | 4 | EACH | - | - |
| 7 | Supply and fixing as in replacement MCCB triple pole and neutral (Four pole) 250Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and fixed magnetic setting and breaking capacity 16 KA including making incoming and outgoing connections complete all as specified and as directed. | 3 | EACH | - | - |
| 8 | Supply and fixing as in replacement MCCB triple pole and neutral (Four pole) 160 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and fixed magnetic setting and breaking capacity 16 KA including making incoming and outgoing connections complete all as specified and as directed. | 4 | EACH | - | - |
| 9 | Materials and labour as in replacement for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip 32x6mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. | 41 | Each Set | - | - |
| 10 | Labour only for boring of hole under roads with mechanical arrangement upto 50 mm dia without disturbing the top surface of the road for passing the cable across the road complete all as specified and as directed. | 36 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.68 MB
1_CONTENT_TO_NOTE_8345.pdf
Tender Documents • 0.68 MB
2_General_Condition_8345.pdf
Tender Documents • 0.78 MB
3_Spl_Con_8345.pdf
Tender Documents • 0.37 MB
4_PS_8345.pdf
Tender Documents • 1.61 MB
BOQ_879517.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].