Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹2.9 L+₹65,072 (29.6%)Rejected-AOC E 73 FF GALI NO 17B SADH NAGAR PALAM COLONY NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L2 | Rejected-AOC other than lowest bidder |
Tender Value
₹4.0 L
EMD Value
₹7,990
Closing Date
3 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I CG
Noida
REPAIR TO ELECTRIC WATER GEYSERS IN OTM ACCN AND MD ACCN AT COAST GUARD STATION NOIDA
2021_MES_457998_1
AGE I CGN 09 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Noida
E b i
7 documents required · 7 mandatory
₹300
AGE I CG
₹7,990
10 Jan 2022
8 Jul 2021
5 Aug 2021
8 Jul 2021
3 Aug 2021
21 Jul 2021
60 days
Amount
Taking down electric water heater/geysers of capacity 25/35/50 ltrs and of any make from its mounting place , opening it for descaling /cleaning of inner tank from deposited scales with descaling solution including checking leak ,testing,sealing of joints, carrying out the minor repair on surface of outer body, bottom and top cover,and re-fixing the geyser in same posn Complete all as directed. Note : (a). Once the geyser is taken down then it shall be inspected by the deptt and may order major repair/replacement of any part which shall be paid seperately . (b) Any damage if occurred during the process of cleaning the geyser will be made good by contactor at no extra cost. (c) A register shall be maintained showing details of repair /replacement , date of taking off , date of refixing . This register shall have signature of contractor , MES Rep and Rep of User .A Geyser after taking off shall be refixed on the day when it was taken including major repair /replacement of parts. (d) In this case the geyser shall be refixed within 48 hours from taking down time revovery from contractor. (e) No Extra cost for transport will be paid for repairs to Market. (f) Spare reuired for replacement shall be measured and paid separately under separate items
M & L for Painting of geysers of any type, make and capacity 25 L with one coat of white paint (spray painting) super enameled white paints after removing of old paints, making smooth surface and marking MES number with black paint in capital letters including providing new PVC ring as per existing PVC ring complete all as specified and as directed by Engr-in-Charge.
M & L for Painting of geysers of any type, make and capacity 50 L with one coat of white paint (spray painting) super enameled white paints after removing of old paints, making smooth surface and marking MES number with black paint in capital letters including providing new PVC ring as per existing PVC ring complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of geyser element of 1.5 KW rating double tube type with cup type or circular/triangle shape including rubber washers suitable to fit in the existing geyser without any water leakage complete all as specified and as directed by Engr-in-Charge . Make : Micron King/Bajaj/Recold/thita/havells.
S&F in replacement of Ceramic heating element of 2 KW rating round long rod shape (construction of element on Ceramic) complete all as specified and as directed by Engr-in-Charge. Make : Micron King/Bajaj/Recold/thita/havells.
S&F in replacement of the Gasket (heat proof rubber) for apparatus plate suitable for the different make of 25 /35/50 litres capacity geysers as per site requirement complete, all as specified and as directed by Engr-in-ChargeMake as per existing or compatible as approved ISI marked
S&F in replacement of heavy duty element holding assembly/ apparatus plate made out of copper and chromium plate( different 6/9 hole or as per site requirement ) with provision for safety valve in its inlet and outlet, pocket for thermostat/ thermal cut system and drain plug all as per site requirement and directed by engineer in charge suitable for 25 litres capacity geysers. Make as per existing or compatible as approved ISI marked
S&F in replacement of heavy duty element holding assembly ( different type hole or without hole) with provision for safety valve in its inlet, pocket for thermostat/ thermal cut system and drain plug all as per site requirement and directed by engineer in charge suitable for 50 litres capacity geysers. MakeMake as per existing or compatible as approved ISI marked
S&F stainless steel inner tank heavy duty in replacement of steel inner tank having pressure bearing capacity 8Kg/Cm.sq. suitable to the existing 25 ltrs capacity geysers. Complete with Nut Bolt and washer, all as specified and as directed by Engr-in-Charge.Make Bajaj/Recold/Jaguar /USHA. Note : Only OEM manufacture SS tank will be accepted.
S&F stainless steel inner tank heavy duty in replacement of steel inner tank having pressure bearing capacity 8Kg/Cm.sq. suitable to the existing 50 ltrs capacity geysers.Complete, all as specified and as directed by Engr-in-Charge.Make Bajaj/Recold/Jaguar /USHA. Note : Only OEM manufacture SS tank will be accepted.
S&F in replacement the thermostat 7'' long for the geysers 25 Ltrs. capacity as per site requirement complete, all as specified and as directed by Engr-in-Charge. Make Bajaj/Digits/Recold/DASS PASS/THETA/Micron King
S&F in replacement the thermostat 11'' long for the geysers 25/35/50 Ltrs. capacity as per site requirement complete, all as specified and as directed by Engr-in-Charge. Make Bajaj/Digits/Recold/DASS PASS/THETA/Micron King
S&F in replacement of Multiple use safety valve /PRV 15mm, bedfor geyser inlet or all as specified and as directed by Engr-in-Charge .Make as per existing or compatible as approved ISI marked
Supply and fixing in replacement of the insulating material i. e. glass wool. complete, all as specified and as directed by Engr-in-Charge .Make as per existing or compatible as approved ISI marked
S&F in replacement steel ribbed connection pipe 450 mm long heavy duty (Hot water) with two brass nut and nylon washer suitable for 15mm dia inlet and outlet pipe of geyser and connecting up complete, all as specified and as directed by Engr-in-Charge .Make as per existing or compatible as approved ISI marked
S&F in replacement steel ribbed connecting pipe 2 Ft length heavy duty (Hot water) with two brass nut and nylon washer suitable for 15mm dia inlet and outlet pipe of geyser and connecting up complete, all as specified and as directed by Engr-in-Charge .Make as Approved ISI marked
S&F in replacement of 1100 Volt grade cable flexible 3 core PVC insulated PVC sheathed with stranded copper conductor of size 2.5 sqmm ISI mark Plaza/Havells/Kalinga.
S&F in replacement of metal plug top 2 pole and earth 240 volts complete all as specified and as directed in Engr–in- Charge . Make: Havells/Snider/Plaza/ Strandard
S&F in replacement of metal Socket 2 pole and earth 240 volts complete all as specified and as directed in Engr–in- Charge . Make: Havells/Snider / Plaza/ Strandard
S&F in replacement of bottom cover made of M S sheet 20 SWG duly painted with two coats of super enamel paint by spray painting complete all as specified and as directed in Engr–in- Charge suitable for 25 ltrs geysers. Make as per existing or compatible as approved ISI marked
S&F in replacement of top cover made of M S sheet 20 SWG duly painted with two coats of super enamel paint by spray painting suitable for 25 ltrs geysers. complete, all as specified and as directed by Engr-in-Charge .Make as per existing or compatible as approved ISI marked
S&F in replacement of indicating lamp Red or Green as per Geyser suitability complete all as specified and as directed by Engr-In-Charge Make as per existing or compatible as approved ISI marked
Supply and fix in replacement of outer body made/fabricated of 20 SWG MS sheet for Geysers of 25 ltrs capacity duly painted with spray paint with clamps 2 Nos of size 15mmx1mm thick with necessary nut and bolts complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of MCB SP 20A ,10KA,230 Volts 50 Hz complete. Make Havells/Legrand /L&T.
S&F sheet metal enclosures with socket single pole and netural with a two pin and earth plug socket complete with one single pole MCB of rating 20 Amp 10 KA of Make as directed in Engr – in- Charge. Make: Havells/Plaza/ Strandard
S & F fastner and bolts suitable size as required for 25/35/50 Ltrs geyser all as directed.
S&F (PRV) Pressure Reducing Valve of 20mm dia suitable for prefixing of 25 Ltr Geyser inlet complete all as directed by Engr in Charge.
M & L in replacement Geyser Heating Element assembly 2000 watt (in Round Shape bottom Assembly) with arrangement of 6 Nut bolt, One no suitable round rubber gasket including one magnesium Rod as required in Bajaj Geyser of Model No CALDIA 25 (150756) complete all as directed. Make Bajaj/Recold/Theeta (As per Sample held with AGE I office0.
S&F Magnesium anode Shakti verticle and Cadila 25 Ltr models complete all as directed by Engr in Charge.
S&F stainless steel inner tank heavy duty in replacement of steel inner tank, having pressure bearing capacity 8Kg/Cm.sq. suitable for existing 25 ltrs capacity geysers Make Racold & Bajaj square shape complete with nut bolt washer etc, all as specified and as directed by Engr-in-Charge.Make Bajaj/Recold/Jaguar /USHA. Note : Only OEM manufacture SS tank will be accepted.
Material and labour for checking the solar water heater of any capacity 300/500 Ltrs of any make for no water in tap , water not heated at all , although cold water flow is normal , water not hot enough or sufficient quantity of hot water is not available . little quantity of boiling hot water is received , leackage of water from collectors etc and cleaning of tubes and collectors etc and testing of solar water heator for desired temperature hot water complete all as directed by Engineer in Charge.
PRASAD ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .