| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAccepted-AOC SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.5 L+₹11,493 (1.81%)Rejected-Finance BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L2 | Rejected-Finance Lowest Two | |
| 3 | L3₹7.1 L+₹74,813 (11.8%)Rejected-Finance 50A 7B 5C UMARPUR NIWA DHOOMANGANJ PRAYAGRAJ UP | PRAYAGRAJ | UTTAR PRADESH | 211011 | L3 | Rejected-Finance Lowest Three |
Tender Value
₹8.0 L
EMD Value
₹16,000
Closing Date
24 May 2023, 6:00 pmClosed
AGE (I) Kanasar
Asst Garrison Engineer (I) Kanasar, Bikaner Military Station Kanasar,Bikaner
REPAIR / MAINTENANCE OF STREET LIGHTS NETWORK AND CONNECTED WORKS AT ZONE B AT MIL STN KANASAR
2023_MES_591402_1
CA NO. AGE (I) KNS/Token No. 03/2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE(I) Kanasar
Contractor shall be enlisted with MES in Class E and above and category b(i) subject to satisfactory remarks wrt performance in respect of works in hand as reflected in Work Load Return (WLR) of any other report circulated by competent engineer
8 documents required · 8 mandatory
₹500
AGE (I) Kanasar
₹16,000
2 Nov 2023
26 Apr 2023
26 May 2023
26 Apr 2023
24 May 2023
10 May 2023
26 Apr 2023 - 3 May 2023
Amount
S & F in replacement and testing LED street light fitting of 15 Watt including LED lamps complete with body robust, corrosion resistant,superior finish and without any cracks or through holes, made in a single piece by pressure die cast housing with toughened glass with Ingress Protection of IP 65/66 protection as per IS-10322-1982 (Part-I) with latest amendments and high power SMD LED's with secondary optics for better light distribution,input voltage range 100-300 V, AC, frequency 50-60 Hz,efficacy ≥ 100 LM/W, P.F >0.95 with THD<10%,ambient temp from -10° C to 50°C, RH 10% to 90%, lamp starting time <10 second and surge protection ≥10 KV .Driver should be potted and have high voltage withstanding capacity upto 300 V, AC, double phase protection complete all as specified and directed.
S & F in replacement and testing LED street light fitting of 45 Watt including LED lamps complete with body robust, corrosion resistant,superior finish and without any cracks or through holes, made in a single piece by pressure die cast housing with toughened glass with Ingress Protection of IP 65/66 protection as per IS-10322-1982 (Part-I) with latest amendments and high power SMD LED's with secondary optics for better light distribution,input voltage range 100-300 V, AC, frequency 50-60 Hz,efficacy ≥ 100 LM/W, P.F >0.95 with THD<10%,ambient temp from -10° C to 50°C, RH 10% to 90%, lamp starting time <10 second and surge protection ≥10 KV .Driver should be potted and have high voltage withstanding capacity upto 300 V, AC, double phase protection complete all as specified and directed.
S & F in replacement and testing LED street light fitting of 90 Watt including LED lamps complete with body robust, corrosion resistant,superior finish and without any cracks or through holes, made in a single piece by pressure die cast aluminium housing with toughened glass with Ingress Protection of IP 66 protection as per IS-10322-1982 (Part-I) with latest amendments and high power SMD LED's with secondary optics for better light distribution,input voltage range 100-300 V, AC, frequency 50-60 Hz,efficacy ≥ 100 LM/W, P.F >0.95 with THD<10%,ambient temp from -10° C to 50°C, RH 10% to 90%, lamp starting time <10 second and surge protection ≥10 KV .Driver should be potted with 4 KV internal surge protection and have high voltage withstanding capacity upto 300 V, AC, double phase protection complete all as specified and directed.
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with constant voltage & current driver and lampas per IS-10322-1982 (Part-I) with latest amendments and high power SMD LED's with secondary optics for better light distribution,input voltage range 100-300 V, AC, frequency 50-60 Hz,efficacy ≥ 110/125 LM/W,beam angle>160 P.F >0.95 with THD<10%,ambient temp from -10° C to 60°C, RH 10% to 90%, lamp starting time <10 second and surge protection ≥4 KV .Driver should be potted with 4 KV internal surge protection and have high voltage withstanding capacity upto 300 V, AC, double phase protection complete all as specified and directed
Excavation in trenches in any type of soil not exceeding 1.5m depth and not exceeding 1.5 metre in width for laying of under ground cable and erection of poles and getting out complete all as specified and directed.
Returning filling with earth obtained from excavation including spreading, watering & consolidation in layers not exceeding 15 cms thick, complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 m & depositing at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material & labour for Tibba Sand filling in trenches with clean dry fine sand unwashed including gently punning around cables complete all as specified and directed
Supply and laying well burnt old size class B Brick laid dry flat for protection over the cable, width equal to the length of cable comlete all as specified.
Taking out existing serviceable /unserviceable bricks over UG Cables, from trenches and stacking at site for re use all as directed.
Laying only old serviceable bricks retrieved from item srl No. 10 above.
Boring of holes under road, pavement hard standing up to 4 mtr length by trenchless technology using ultra sound technique and necessary machine 100 mm dia for laying of cable all as directed by Engr-In-Charge
Supply and laying GI pipe dia 40 mm, light grade for the protection of the cable passing through road crossing etc. complete all as specified and directed. .
Supply and laying GI pipe dia 50 mm, light grade for the protection of the cable passing through road crossing etc. complete all as specified and directed.
Supply, laying and testing 10 Sqmm 4 core cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric power cables with stranded aluminium conductor 1100 Volts grade under ground cable laid in trenches/through pipe/fixed along pole etc all as directed by Engineer-in-Charge.
Supply, laying and testing 35 Sqmm 3.5 core cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric power cables with stranded aluminium conductor 1100 Volts grade under ground cable laid in trenches/through pipe/fixed along pole etc all as directed by Engineer-in-Charge.
Material & labour for cable jointing kit for 1.1 KV (Earthed) grade cable for Outdoor straight through joint complete with jointing material and accessories suitablae for 4/3.5 core XLPE armoured aluminium conductor cable of size 6 sqmm to 16 Sqmm complete all as specified and directed..
Material & labour for cable jointing kit for 1.1 KV (Earthed) grade cable for Outdoor straight through joint complete with jointing material and accessories suitablae for 4/3.5 core XLPE armoured aluminium conductor cable of size 25 sqmm to 50 Sqmm complete all as specified and directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire,one twin core cable flat or circular of size 6 sqmm complete all as specified and directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire,one twin core cable flat or circular of size 10 sqmm complete all as specified and directed.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 1m x 2 m complete all as specified and directed.
M & L for Cleaning and prepration of old painted surface with amren paper of steel tubular pole 9/9.5 long and painting with one coat of enamelled aluminium paint including clamps etc. and making alternative black and white strips on pole with synthetic enamel paint (each strip 30 cm height) upto 1.5 mtr long height from top of PCC foundation block and writing pole Nos including applying one coat of cement base paint on PCC coping complete all as directed by Engineer-in-Charge.
Material & labour for cleaning internal & external surface, removing other foreign material and rubbing of external surface by amren paper of feeder pillar box/LT panels and preparing the both surface for paint, spraying by gun one coat of synthetic enamel paint of existing colour of panel on Internal and External surface, including minor repairing of panels like door hinges, locks and making provision for external lock with welding/nuts bolts and providing detachable gland plate with cable gland with closure for cable entry as required on ground etc complete all as specified and directed .
BIDAWAT ENTERPRISES
SS CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .