Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹12 L+₹1.6 L (15.8%)Rejected-Finance AT AMRITPUR PO NB CHILKA DIST KHURDA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹13.0 L+₹2.6 L (25.3%)Rejected-Finance AMRITPUR PO INS CHILKA DIST KHURDA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹13.4 L+₹3.1 L (29.5%)Rejected-Finance AT AMRITPUR PO NB CHILKA VIA BALUGAON DIST KHURDA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L4 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹28,000
Closing Date
12 Mar 2021, 6:00 pmClosed
Garrison Engineer Chilka
Garrison Engineer Chilka PO INS Chilka Distt Khordha Odisha 752037
SPL REPAIR OF VINTAGE ALUMINIUM WIRING WITH NEW COPPER WIRING IN VARIOUS WARDS AND DEPARTMENTS OF INHS NIVARINI AT INS CHILKA UNDER GE CHILKA
2021_MES_421792_1
GE/CHL/8705 OF 2020-2021
Open Tender
Civil Works
Item Rate
182 days
Garrison Engineer Chilka
MES Enlisted Contractor of class E category b i
6 documents required · 6 mandatory
₹500
Yes
Garrison Engineer Chilka
₹28,000
Yes
30 Mar 2021
12 Feb 2021
19 Mar 2021
12 Feb 2021
12 Mar 2021
26 Feb 2021
12 Feb 2021 - 19 Feb 2021
Amount
Taking down carefully copper/ aluminium point wiring for light, fan, socket or power point complete with fittings such as switches, fan regulators, light fittings, tube light fittings, bracket light fittings and ceilling rose, holders etc including making good the disturbed surface of walls, complete all as specified and as directed.
M & L for point wiring with PVC FRLS insulated unsheathed multi stranded copper conductor cable of size 1.5 Sqmm drawn through in including surface PVC casing and caping (ISI Marked) not less than 20mm wide with existing sunken box including 3 mm thick laminated sheets for mounting switches/sockets with all accessories as required including 1.5 Sqmm copper conductor FRLS cable for earth continuity conductor of green colour for one light point/ fan point/ bell point/ one 5/6 Amp socket outlet controlled by one 5/6 Amps one way switch complete all as specified and as directed.
All as per item No 2 above but, one socket outlet, three pin, 5/6 Amp on the same board with other switches complete all as specified and as directed.
All as per item No 2 above but for staircase light point controlled by 02 Nos two way switch complete all as specified and as directed.
All as per item No. 2 here-in-before but for 15/16Amp socket out let, independent with 4.0 Sqmm copper cable of PVC FRLS insulated, unsheathed, multi stranded and 4.0 Sqmm copper conductor cable FRLS as earth continuity conductor of green colour complete all as specified and as directed.
Taking down carefully sub main wiring including batten/ conduit by unscrewing from wall,ceiling and making good surfaces to match with existing complete all as specified and as directed.
M&L sub main wiring with 4 runs of 10 Sqmm PVC FRLS insulated unsheathed copper cable multistand 1100 Volt and two runs of copper earth wire 10 Sqmm PVC FRLS drawn in and including concealed PVC conduit not less than 25mm dia and necessary cutting and chasing as required including making good to existing surface complete all as specified and as directed. Note:- 4 runs of 10 Sqmm copper cable, 2 run of 10 Sqmm copper earth wire and one run of PVC conduit shall be measured as one unit length.
M&L sub main wiring with two runs of 6.0 sqmm PVC FRLS insulated unsheathed copper cable multistand 1100 Volt and one run of copper earth wire 6.0 sqmm PVC FRLS drawn in and including surface casing and caping not less than 25mm wide complete all as specified and as directed. Note:- 2 runs of 6 sqmm copper cable, one run of 6.0 sqmm copper earth wire and one run of casing andcaping shall be measured as one unit length.
M&L sub main wiring with two runs of 4.0 sqmm PVC FRLS insulated unsheathed copper cable multistand 1100 Volt and one run of copper earth wire 4.0 sqmm PVC FRLS drawn in and including surface casing and caping not less than 25mm wide complete all as specified and as directed. Note:- 2 runs of 4 sqmm copper cable, one run of 4.0 sqmm copper earth wire and one run of casing and caping shall be measured as one unit length.
S&F switch piano, flush type, single pole, one way, 5/6 Amp, complete all as specified and as directed.
S&F switch piano, flush type, single pole, two way, 5/6 Amp, complete all as specified and as directed.
S&F switch socket combination 3 pin 5 Amp, 230 volt complete all as specified and as directed.
S&F switch socket combination 2 in 1, 3 pin 5/15 Amp, 230 volt, multipurpose, complete all as specified and as directed.
S&F ceiling rose, surface bakelite 65 x 30mm, three terminals including PVC box of size 3"x3" round type complete all as specified and as directed.
S&F five stepped socket type electronic fan regulator for ceiling fan of any sweep including necessary connection complete all as specified and as directed.
S&F bell push, flush type, AC 230 volts complete all as specified and as directed.
S&F bell electric, AC, 230 volts, complete all as specified and as directed.
S&F in replacement 10 Watt LED Bulk Head fitting Environmenatal friendly, ultra morden, energy saving, surface mounted, decorative oval bulk head edge- lit LED luminaries comprising of high brightness LEDs complete all as specified and as directed. Make:- Bajaj Cat No BIBWP10WLED (Product code 112334) or Havells Cat Part No. HEXAFT10WLED857SSYMBOPC or Philips Cat Part No. WT202WLED6SCWPSUSIPC as approved.
S&F in replacement 1X18 Watt indoor type retrofit batten type luminaries complete with LED retrofit T8 polycarbonate tube of capacity 18 Watt with decorative holder including connection with three core twisted flexible copper conductor cable of suitable size upto ceiling rose complete all as specified and as directed. Make:- Havells Cat Part No. REGALBATTENT8UPTO1X22WDSBSWH (Batten) and PHOTONULTRA18W LED865G13(LHLDCLXNUL8X018)(LED Lamp)or Wipro Cat Part No. W10921208 (Batten / Channel ) & LL13-181-65SE(LED Lamp) or Bajaj Cat part No for Batten : BLRB-DB118 &Tube : BLRB 18W CW or Philips Cat Part No.BN550WLED20-3000 as approved.
S&F 9 W tubelight fitting with LED lamp of capacity 9 Watt , Endura linear LED Wall mounted LED batten with polycarbonate housing & intergated driver for efficient heat dissipation with including connection with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed. Make:- Havells Cat part No: LUMILINEBS 9 W LED865SPCWH or Bajaj Cat part No: BCLSB 10 WH or equivalent in Philips
S&F in replacement of LED street light 25W, made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having top opening separate driver compartment with IP 66 protection and impact resistance of IK07 complete all as specified and as directed . Make :- Bajaj Cat Part No.BCLST 25W LED or Havells Cat Part No : ENDURAPEARLSL25WLED757SASYTOPC as approved.
Taking down defective exhaust fan from its position and refixing the same after necessary minor repair to make its functional complete all as specified and as directed.
M&L for spray painting with white synthetic enamel paint including preparation of old surface of the ceiling fan of any make/model/sweep, filling cavities with filler after cleaning dust in situ or in other position complete all as specified and as directed. Make :- Berger paint(Luxol)/Asian paint (Apcolite) / Jenson & Nicholson paint Ltd (Brolac)
Taking down defective ceiling fan from its position and refixing the same after necessary minor repair to make its functional complete all as specified and as directed.
M&L for rewinding of ceiling fan motor of 1200 mm sweep of any make with super enameled copper wire of existing gauge including replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with golden colour varnish, greasing the bearings, replacement of missing / worn out nuts, bolts and washers, split pins etc complete all as specified and as directed
S&F in repair capacitor/ condenser of ceiling fan 2.5 mfd of approved make complete all as specified and as directed. Make :- Nicco/Havells/Universal
S&F in repair capacitor /condenser of exhaust fan 4 mfd of approved make complete all as specified and as directed. Make :- Nicco/Havells/Universal
M&L for rewinding of Exhaust fan /wall mounting fan motor of 300/380 mm sweep of any make with super enameled copper wire of existing gauge including replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with varnish , greasing the bearing, replacement of missing/worn out nuts, bolts and washers, split pins etc complete all as specified and as directed.
S&F in replacement of ball bearing 6201 / 6202 / 6203 including metal filling, machining if required complete all as specified and as directed. Make :- SKF/NBC as approved
S&F in replacement of clamp with nuts , bolts and rubber bush suitable for ceiling fan of any sweep and make as per existing size and shape complete all as specified and as directed
Taking down carefully existing unserviceable MCB DBs with MCBs any type by unscrewing from wall,ceiling and making good surfaces to match with the existing complete all as specified and as directed.
S&F factory made sheet metal enclosure for DBs double door (fixed flush to the wall), SPN, 240 volt, 8 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 sqmm copper PVC sheathed stranded cable for earth continuity and suitable for housing MCB’s complete all as specified and as directed. Make:- C&S Electric Ltd /Standard/Havells
S&F MCB 6 to 32 Amp, 240 Volt, SP, breaking capacity 10 KA 'C' series, complete all as specified and as directed. Make:- C&S Electric Ltd/Standard/Havells.
S&F MCB 40 Amp, 240 Volt, SPN, breaking capacity 10 KA 'C' series, complete all as specified and as directed. Make:- C&S Electric Ltd/Standard/Havells.
S&F in replacement of LED retrofit lamp B22 holder base with polycarbonate body and aluminium heat sink of 09/10W complete all as specified and as directed. Make:- Bajaj/Havells/Philips
S&F in replacement angle holder for LED bulb of any type complete all as specified and as directed.
S&F in replacement of Factory made sheet metal enclosure for DBs double door (fixed flush to the wall), TPN, 415 volt, 4 Way, IP-42 protection with 200 Amp rated bus bar and 6.0 sqmm copper PVC sheathed stranded cable for earth continuity and suitable for housing MCB’s complete all as specified and as directed. Make:- C&S Electric Ltd/Standard/Havells.
S&F in replacement MCB 63 Amp, 415 Volt, TPN, breaking capacity 10 KA 'C' series, complete all as specified and as directed. Make:- C&S Electric Ltd/Standard/Havells.
M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galavanised earth strip 32mmx6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part-I - 2009, connected to earthing point of outdoor panel boards all as specified including excavation and earth work any type of soil, PCC 1:3:6 type C-1 using 20mm graded stone aggregate for chamber and 40mm thick RCC 1:2:4 type B-1 using 20mm graded stone aggregate, reinforced with 8mm dia deformed (TMT bars) at 150mm c/c both ways, 50mm dia GI pipe light grade for ptotection, 20mm dia GI medium grade pipe for watering , funnel etc complete all as specified and testing on completion.
M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4.0 mm dia (upto 7.5 M in length from earth plate) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part-2009, connected to earthing with DBs all as specified including excavation and earth work in any type of soil, PCC 1:3:6 type C-1 using 20mm graded stone aggregate in chamber & 40mm thick RCC 1:2:4 type B-1 using 20mm graded stone aggregate as in cover slab, reinforced, with 8mm dia TMT bar at 150mm c/c both ways, 15mm dia galvanised iron pipe light grade for earth lead protection, 20mm dia galvanised ironI medium grade pipe for watering , water funnel etc complete all as specified and testing on completion.
PABITRA MOHAN PARIDA
PRASANTA KUMAR PANDA
PRADIPTA KUMAR PANI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .