Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹34.3 LAccepted-AOC STATION ROAD POST RANGIYA DIST KAMRUP ASSAM PIN 781354 | KAMRUP | ASSAM | 781354 | ₹34.3 L Quoted ₹34.4 L | L-1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER |
| 2 | L-2₹35.0 LRejected-Finance | ₹35.0 L | L-2 | Rejected-Finance BEING L2 BIDDER |
| 3 | L-3₹36.0 LRejected-Finance VILL BAREGAON PO CHAK CHAKA BAZAR DIST BARPE | BARPETA | ASSAM | 781301 | ₹36.0 L | L-3 | Rejected-Finance BEING L3 BIDDER |
| 4 | L-4₹36.6 LRejected-Finance | ₹36.6 L | L-4 | Rejected-Finance BEING L4 BIDDER |
| 5 | L-5₹36.9 LRejected-Finance | ₹36.9 L | L-5 | Rejected-Finance BEING L5 BIDDER |
| Sl No | Description | Qty | Unit | M/S KIRAN ENTERPRISE L1 | M/S S.S. Construction L8 | R K Enterprises L4 | OM CONSTRUCTIONS L6 | SYED ATAUR RAHMAN L2 | M/S SITAL BUILDERS L5 | M/s DEBOJIT ROY L3 | M/s Narzary Enterprise L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Surface dressing n exc 15 cm deep and getting out in soft/loose soil, complete all as per specified and as directed by Engineer-in-charge. | 221 | SQM | 25 ₹5,525 | 20 ₹4,420 | 26 ₹5,746 | 65 ₹14,365 | 20 ₹4,420 | 9 ₹1,989 | 20 ₹4,420 | 40 ₹8,840 |
| 2.00 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge. | 64.8 | CUM | 150 ₹9,720 | 225 ₹14,580 | 166 ₹10,756.80 | 125 ₹8,100 | 150 ₹9,720 | 139 ₹9,007.20 | 120 ₹7,776 | 180 ₹11,664 |
| 3.00 | Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge. | 17.72 | CUM | 60 ₹1,063.20 | 60 ₹1,063.20 | 33 ₹584.76 | 55 ₹974.60 | 75 ₹1,329 | 39 ₹691.08 | 100 ₹1,772 | 100 ₹1,772 |
| 4.00 | Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge. | 33.58 | CUM | 65 ₹2,182.70 | 90 ₹3,022.20 | 32 ₹1,074.56 | 60 ₹2,014.80 | 125 ₹4,197.50 | 39 ₹1,309.62 | 100 ₹3,358 | 130 ₹4,365.40 |
| 5.00 | M&L for anti-termite treating the bottom and sides of excavation @ 5 litres of emulsion per square metre of surface area, complete all as per specified and as directed by Engineer-in-charge. | 70 | SQM | 60 ₹4,200 | 110 ₹7,700 | 144 ₹10,080 | 135 ₹9,450 | 130 ₹9,100 | 139 ₹9,730 | 120 ₹8,400 | 110 ₹7,700 |
| 6.00 | M&L for anti-termite treating the backfill in contact with foundation @ 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured), complete all as per specified and as directed by Engineer-in-charge. | 15 | SQM | 65 ₹975 | 110 ₹1,650 | 144 ₹2,160 | 135 ₹2,025 | 200 ₹3,000 | 159 ₹2,385 | 120 ₹1,800 | 150 ₹2,250 |
| 7.00 | M&L for anti-termite treating the top surface of filled earth @ 5 litres of emulsion per square metre of surface, complete all as per specified and as directed by Engineer-in-charge. | 221 | SQM | 55 ₹12,155 | 110 ₹24,310 | 144 ₹31,824 | 135 ₹29,835 | 130 ₹28,730 | 139 ₹30,719 | 100 ₹22,100 | 110 ₹24,310 |
| 8.00 | M&L for anti-termite treating the soil under plinth protection @ 5 litres of emulsion per square metre of surface area, complete all as per specified and as directed by Engineer-in-charge. | 50 | SQM | 60 ₹3,000 | 110 ₹5,500 | 144 ₹7,200 | 135 ₹6,750 | 130 ₹6,500 | 179 ₹8,950 | 150 ₹7,500 | 110 ₹5,500 |
| 9.00 | M&L for anti-termite treating the soil along with external perimeter of building @ 2.25 litre of emulsion per metre of the perimeter wall, complete all as per specified and as directed by Engineer-in-charge. | 55 | RM | 55 ₹3,025 | 50 ₹2,750 | 144 ₹7,920 | 135 ₹7,425 | 60 ₹3,300 | 179 ₹9,845 | 120 ₹6,600 | 60 ₹3,300 |
| 10.00 | M&L for Hardcore with broken stones/ boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed by Engineer-in-charge. | 13.92 | CUM | 1,800 ₹25,056 | 2,000 ₹27,840 | 1,555 ₹21,645.60 | 1,700 ₹23,664 | 1,750 ₹24,360 | 1,999 ₹27,826.08 | 2,000 ₹27,840 | 1,800 ₹25,056 |
Updated dates
Tender Value
₹39.7 L
EMD Value
₹79,500
Closing Date
6 Nov 2025, 6:00 pmClosed
GE Rangia
GE Rangia C/O 99 APO Rangia
PROVN OF TRANSIT FACILITY AT TAMULPUR MIL STN UNDER GE RANGIA
2025_MES_734590_1
8867/RNG/E8
Open Tender
Civil Works
180 days
TAMULPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Rangia
₹79,500
Yes
26 Dec 2025
10 Oct 2025
8 Nov 2025
10 Oct 2025
6 Nov 2025
25 Oct 2025
10 Oct 2025 - 17 Oct 2025
Amount
Surface dressing n exc 15 cm deep and getting out in soft/loose soil, complete all as per specified and as directed by Engineer-in-charge.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge.
Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
M&L for anti-termite treating the bottom and sides of excavation @ 5 litres of emulsion per square metre of surface area, complete all as per specified and as directed by Engineer-in-charge.
M&L for anti-termite treating the backfill in contact with foundation @ 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured), complete all as per specified and as directed by Engineer-in-charge.
M&L for anti-termite treating the top surface of filled earth @ 5 litres of emulsion per square metre of surface, complete all as per specified and as directed by Engineer-in-charge.
M&L for anti-termite treating the soil under plinth protection @ 5 litres of emulsion per square metre of surface area, complete all as per specified and as directed by Engineer-in-charge.
M&L for anti-termite treating the soil along with external perimeter of building @ 2.25 litre of emulsion per metre of the perimeter wall, complete all as per specified and as directed by Engineer-in-charge.
M&L for Hardcore with broken stones/ boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed by Engineer-in-charge.
M&L for sand filling under floors or in foundations spreading and levelling in layers not exc. 25 cm thick including watering and consolidation or Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as per specified and as directed by Engineer-in-charge. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be measured and paid for.
M&L for PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundations, fillings and mass concrete complete all as per specified and as directed by Engineer-in-charge.
M&L for Reinforced Cement Concrete, M-25 (Design Mix) (20mm graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
M&L for Reinforced Cement Concrete, M-25 (Design Mix) (20mm graded stone aggregate) in Columns, pillars, piers, posts and struts, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
M&L for Reinforced Cement Concrete, M-25 (Design Mix) (20mm graded stone aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span, chajjas, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
M&L for Reinforced Cement Concrete, M-25 (Design Mix) (20mm graded stone aggregate) in in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves, coocking platform and the like, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
M&L for precast reinforced cement concrete 1:2:4, type-B1 (Using 20 mm graded stone aggregate) in landings, cover slabs (for manholes, etc.) shelves and similar articles with plain faces and set in cement mortar 1:4, complete all as per specified and as directed by Engineer-in-charge. NOTE : Reinforcement will be measured and paid separately under relevant Item.
M&L for PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) in surface channels and drains, including necessary formwork, complete all as specified and as directed by Engineer-in-charge.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions, rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, chajjas, etc. also splays between floors and beams, etc., rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge.
S&F of TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-charge.
S&F of TMT bars 6-8mm dia, cut to length, bent to shape required, in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-charge.
S&F of Mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and as directed by Engineer-in-charge.
S&F of mild steel flat iron or other steel section as in hold-fast, wall tie, wind ties for roof including drilling, securing bolts and similar work conforming to Fe-290 Gde E-165, complete all as specified and as directed by Engineer-in-charge.
M&L for Brickwork with Sub-class 'B' bricks, straight or curved on plan to any radius built and set in cement mortar 1:6, complete all as per specified and as directed by Engineer-in-charge.
M&L for Rendering 10mm thick in cement morter 1:6 on fair faces of brick work or concrete surfaces/ one side of lathing, finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-in-charge.
M&L for Rendering (Externally) 15mm thick in Cement Mortar 1:4 in two layers on other than fair faces Brick Walls/Concrete Surfaces/ other side of lathing, 5mm thick top layer mixed with WPC as per Manufactures instruction, plastered surfaces finished Even and Smooth without using Extra Cement, complete all as specified and as directed by Engineer-in-charge. NOTE: WPC shall be Measured and Paid as ‘Supply only’ under relevant Item.
Supply only Integral waterproofing compound, complete all as specified and as directed by Engineer-in-charge.
M&L for providing 40mm thick damp proof course to horizontal or vertical surfaces including necessary formwork in cement concrete (1:2:4), type B-0 (12.5mm gradded stone aggregates), complete all as per specified and as directed by Engineer-in-charge.
M&L for providing 100 mm thick Cement concrete type D-2, 1:4:8 (40mm graded stone aggregate) as in sub-base of floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and rough, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing 75 mm thick Cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) as in floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and fair, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing 40 mm thick Cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as in base of floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and rough, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing Non-skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc., laid over 20mm thick cement screed 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing Vitrified Ceramic light shade tiles 8 to 10 mm thick (square/ rectangular) area of each tile not exceeding 0.36 sqm, in floors etc., laid over 20mm thick cement screed 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing Vitrified Ceramic light shade tiles 8 to 10 mm thick (square/ rectangular) area of each tile not exceeding 0.36 sqm in vertical surface (like skirting, dado, etc.) over 10mm thick cement screed 1:3 set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing Glazed ceramic coloured tiles in vertical surface (like skirting, dado, etc.) 300x600x 7 mm thick, over 10mm thick cement screed 1:3 set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as per specified and as directed by Engineer-in-charge.
M&L for Granite (of any type) slab 20mm thick machine cut, over 20mm thick cement screed base 1:6, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing, complete all as per specified and as directed by Engineer-in-charge.
M&L for Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations, complete all as per specified and as directed by Engineer-in-charge.
S&F of Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube; complete all as specified and as directed by Engineer-in-charge.
S&F of Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement; complete all as specified and as directed by Engineer-in-charge.
S&F of 100 mm long Butt hinges, medium weight, stainless steel, complete all as specified and as directed by Engineer-in-charge.
S&F of 150 mm long Extruded aluminium alloy handles, febricated type, anodised, complete all as specified and as directed by Engineer-in-charge.
S&F of 150 mm long Aluminium anodised, barrel tower bolts of extruded section, complete all as specified and as directed by Engineer-in-charge.
S&F of 20 mm dia mild steel, chromium plated curtain rail with fixing brackets, stops, rollers etc., complete all as specified and as directed by Engineer-in-charge.
S&F of exposed powder coated GI snap grid frame work (600x600 mm) for false ceiling comprising of wall/cleat angle of size 25x25x0.35mm and cross tee of size 24x38x0.70mm with suspended hangers of 2 mm dia. G.I. (upto 1200mm length) adjusting level fixed to any type of roof by means of ceilling cleats with and including supplying & fixing/ laying/ inserting of pre-painted (white) 4mm thick designer classic E-boards (595x595 mm) to GI frame work, complete all as specified and as directed by Engineer-in-charge.
S&F of 0.50mm thick Pre-painted galvalume aluminum zinc coating GI based semi-corrugated (trapizoidal profile) steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-in-charge.
S&F of 0.50mm thick Pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-in-charge.
M&L for preparing newly plastered surfaces of wall and applying two coats of cement base paint of any shade over a coat of alkali-resistant priming paint, complete all as specified and as directed by Engineer-in-charge.
M&L for preparing newly plastered surfaces of wall and applying two coats of distemper oil emulsion of any shade over a coat of chalk whitening and a coat of avg 2.00mm thick wall care putty including rubbing down the putty surfaces to obtained smooth finish, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously un-treated steel/iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of Synthetic enamel paint (1st quality) of any tint over a coat of red oxide primer, complete all as specified and as directed by Engineer-in-charge.
S&F of Health faucet ABS Body chromium plated suitable for 15 mm dia pipe with 1.0 metre long flexible tube and ABS wall hook including making connections and fixed in position, complete all as specified and as directed by Engineer-in-charge.
M&L for cutting chases, pinning in brick walls making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth, complete all as per specified and as directed by Engineer-in-charge.
S&F of 25 mm bore (dia), gun metal gate valves with iron wheel head, screwed both ends for iron pipe, ISI Marked, as per IS: 778, complete all as specified and as directed by Engineer-in-charge.
S&F of 20mm dia (Outer) CPVC pipes SDR 13.5 & Plain CPVC SDR 13.5 fittings fixed to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 59 here-in-above, but for 25mm dia (Outer) CPVC pipes SDR 13.5 & Plain CPVC SDR 13.5 fittings, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 59 here-in-above, but for 32mm dia (Outer) CPVC pipes SDR 13.5 & Plain CPVC SDR 13.5 fittings, complete all as specified and as directed by Engineer-in-charge.
S&F of Brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges, complete all as specified and as directed by Engineer-in-charge.
S&F of Brass chromium plated towel ring, square type, fixing to wall with CP brass screws, complete all as specified and as directed by Engineer-in-charge.
S&F of sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, complete all as specified and as directed by Engineer-in-charge.
S&F of Vitreous China Thin Rim Table Top Basin, Shape - Square, Size: 420x420x150mm, white, including cutting for and pinning in ends of brackets or erecting stand, fixing of 15mm dia 450mm long PVC connection pipe and 32mm dia 900mm long PVC Flexible waste pipe with and including 32mm dia Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. complete all as specified and as directed by Engineer-in-charge. MAKE- JAQUAR, Cat Part No- JDS-WHT-25911
S&F of Vitreous China Bowl With Cistern For Coupled WC With UF Soft Close Slim Seat Cover, Hinges, Dual Flush Cistern Fitting And Fixing Accessories, Size: 365x630x750 mm, P Trap-180 mm, white, including connection to drain (or outgoing pipe) and antisyphonage pipe, etc., complete all as specified and as directed by Engineer-in-charge. MAKE- JAQUAR, Cat Part No- FNS-WHT-40751P180UFSMZ
S&F of 15 mm dia fancy type Brass CP basin mixer without pop up waste for mixing hot & cold water, screwed for iron pipe, complete all as specified and as directed by Engineer-in-charge.
S&F of 15 mm dia fancy type Brass CP telephonic wall mixer with over head shower for mixing hot & cold water, screwed for iron pipe, complete all as specified and as directed by Engineer-in-charge.
S&F of Brass chromium plated shower rose with arm of 125mm dia of rose and 200mm long arm, fixing to existing pipe or union of 15 mm dia, complete all as specified and as directed by Engineer-in-charge.
S&F of 15 mm dia fancy type chromium plated Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and as directed by Engineer-in-charge.
S&F of 15 mm dia fancy type chromium plated Bib taps, 2-in-1 (2-way) cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and as directed by Engineer-in-charge.
S&F of 15 mm dia fancy type chromium plated Pillar taps, cast copper alloy, with capstan heads, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe, complete all as specified and as directed by Engineer-in-charge.
S&F of 15 mm dia fancy type, chromium plated Stop valves/ Angle valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and as directed by Engineer-in-charge.
S&F of brass CP Soap Dish with wall flange, oval type, fixing to wall with CP brass screws, complete all as specified and as directed by Engineer-in-charge.
S&F of corner Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 30cm long, complete all as specified and as directed by Engineer-in-charge.
M&L for providing 100mm thick cement concrete 1:3:6, type C-2 (40mm graded aggregates) bed to 100/110mm dia drain pipes including packing under and haunching against the sides of pipes after they are laid and tested, complete all as specified and as directed by Engineer-in-charge.
M&L for providing 100mm thick cement concrete 1:3:6, type C-2 (40mm graded aggregates) bed to 150/160mm dia drain pipes including packing under and haunching against the sides of pipes after they are laid and tested, complete all as specified and as directed by Engineer-in-charge.
S&F of 160mm dia PVC (SWR) pipes including necessary fittings (bend, Tee, etc.) of any type, single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and as directed by Engineer-in-charge.
S&F of 110mm dia PVC (SWR) pipes including necessary fittings (bend, Tee, etc.) of any type, single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and as directed by Engineer-in-charge.
S&F of 75mm dia PVC (SWR) pipes including necessary fittings (bend, Tee, etc.) of any type, single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and as directed by Engineer-in-charge.
S&F of 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as specified and as directed by Engineer-in-charge.
S&F of 110mm dia PVC (SWR) vent cowl, complete all as specified and as directed by Engineer-in-charge.
S&F of PVC connection pipe 15mm dia with PTMT nuts of length 450mm, complete all as specified and as directed by Engineer-in-charge.
M&L for constuction of masonary (Brick work with sub class 'B' bricks in full brick wall in CM 1:6) two stagging walls with double stable of standard size of height upto 3.0m above GL as per drawing no RNG/ TD/ 37 sheet 1/1 for PVC Tank as per specification of SSR Part-I(2009), complete all as specified and as directed by Engineer-in-charge.
Supply, install and testing of LLDPE septic tank conventional design with top cover suitable for 10 Users with and including earthwork in excavation, 150mm thick P.C.C. 1:4:8 (type D-2) for bed, making connections of inlet/ outlet/ Vent pipe, returning filling and removing of surplus soil at a distance of not exceeding 50.0m from site, complete all as specified and as directed by Engineer-in-charge.
M&L for constuction of masonary soakage well of 1.80m internal dia and 3.0m effective depth with and including necessary earthwork in excavation in soft/ loose soil, P.C.C. 1:4:8 type D-2 as in foundation filling, brick masonary with sub class B bricks in one brick thick honey comb walling in CM 1:4, pre-cast R.C.C. (1:2:4) cover slab, 15mm thick rendering in CM 1:4 outside of well and cover slab upto a depth of 150mm below GL, broken brick loose filling inside the well including making connection with drains/ pipe with proper haunching, benching in cement concrete 1:2:4, type B-1, complete all as specified and as directed by Engineer-in-charge.
S&F of Rotational Moulded Polyethylene Water Storage Tank 1000 Litre capacity (Cylindrical Vertical with Closed Top), 3 layered, hoisted and fixed in position, all as specified in MES Schedule Part-I with and including providing 20 mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 210gm), complete all as specified and as directed by Engineer-in-charge.
M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and incl concealed (on wall only) PVC conduit (medium grade) with fittings of adequate dia and length with all accessories and fittings like bends, elbow, crosses, etc. with modular terminal boxes with cover plate and frame for mounting fittings like; switches, sockets, fan regulator, etc. incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly for one light/ fan/ exhaust fan/ bell point controlled by one 1-way switch/ bell push, complete all as per specified and as directed by Engineer-in-Charge.
All as per Item No. 88 here-in-above, but for One 3 pin socket outlet, 5 Amps, same board, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 88 here-in-above, but for One 3 pin socket outlet, 5 Amps, independent board, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 88 here-in-above, but for One 3 pin socket outlet, 15 Amps, independent board, with cables 4.0 sq. mm size, complete all as specified and as directed by Engineer-in-charge.
S&F Modular Switch, One Module, 1-Way10 Amps, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F Modular Switch, One Module, 1-Way, 20 Amps, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F Modular Socket, 2/3 Pin, combined, Two Module, 10 Amp, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F Modular Socket, 2/3 Pin, combined, Two Module, 20 Amp, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F of ceiling rose surface backelite three terminals, PVC/ polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge.
S&F of stepped type modular electronic fan regulator, 120W, 2-module, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F modular Bell push, one-module 10 amp, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of Bell Buzzer/ Ding Dong, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of Sub-main Wiring with 2-Runs of Single Core 6.0 Sq mm PVC insulated FRLSH multi-stranded 1100 Volts grade with Copper Conductor drawn through and including PVC conduit (medium grade) ISI marked and its Accessories including 1-Run of Single Core 6.0 Sq mm PVC insulated FRLSH unsheated multi-stranded 1100 Volts grade with Copper Conductor Cable as Earth Continuty Conductor along with the Wiring and connected from DB to DB/Main Board, complete all as specified and as directed. NOTE :- (a) Cost of PVC conduit (medium grade) with all Fittings/Accessories will deem to be included in the quoted UNIT RATE. (b) Cables as mentioned in SCHEDULE ‘A’ Items and 1-Run of PVC conduit with all Fittings/Accessories will be measured and paid as ONE UNIT. (c) Sub-main Wiring will be measured as length of PVC conduit only. Wire required for looping, etc as ordered will deem to be included in the quoted UNIT RATE.
S&F of Sheet Metal Enclosure Vertical MCB DB TPN (VTPN), 4 way 415 volt, with rated Bus-bar, Double door type DB suitable for mounting incoming MCCB and outgoing MCBs of any type, complete all as specified and as directed by Engineer-in-charge.
S&F of MCCB 63 Amps, 415 Volt for fixing on DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60947-2, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
S&F of Sheet Metal Enclosure MCB DB SPN, 8 way 240 volt, with rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoing MCBs of any type, complete all as specified and as directed by Engineer-in-charge.
S&F of MCB Single Pole & Neutral (SPN), 'C' Curve, 32 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
S&F of MCB Single Pole (SP), 'C' Curve, 6-32 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
S&F of surface and wall mounted LED tube light fitting (separate batten and rod shall be measured as single unit) 1x 20W, (4 Feet) with aluminium housing & integrated electronic driver, 6500K, 220-240 Volts, AC decorative regal type with and including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engineer-in-charge.
S&F of surface and wall mounted LED light fitting mirror type 1x 10W, (2 Feet) with aluminium housing & integrated electronic driver, 6500K, 220-240 Volts, AC decorative box type with and including LED lamp connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engineer-in-charge.
S&F of slim square panel LED luminaire with frame 600 mm x 600 mm, white powder coated with CRCA housing, 35/36 watt, 220-240 V, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cables of suitable size, complete all as specified and as directed by Engineer-in-charge.
S&F of Decorative wall light made up of high grade engineering plastic material suitable for upto 20 W LED lamp B22 base, with necessary elecrical connections, complete as all specified and as directed by Engineer-in-charge.
S&F of ceiling fans complete with blades, down rods, hook and other accessories, 230 V, 1400 mm sweep, Min air delivery 220 CFM with service value 6.00 BEE Five star rated with brushless direct current motor (BLDC), including connecting up with three core flexible copper cables of suitable size, complete all as specified and as directed by Engineer-in-charge.
S&F of exhaust fan, sturdy engineering plastic body, AC single Phase, 230V, 50 Hz, RPM 1200, Copper winding of size250mm sweep with, blades, frame and louvers including connecting up with three core flexible copper cables of suitable size, complete all as specified and as directed by Engineer-in-charge.
S&F Energy saving new generation environmental friendly long life versatile presure die cast aluminium housing IP 66 building security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts with pre wired and lens embedded PC cover having Bottom opening seperate driver compartment and Impact resistance of IK08 with necessary mounting arrangements, complete all as specified and as directed by Engineer-in-charge.
S&F of electric water heater (Geyser), vertical type storage, steel body and stainless steel inner tank with fero glass coating for corrosion resistance and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc, including commissioning and testing complete all as specified and as directed by Engineer-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (medium grade) and chamber and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs), complete all as specified & testing on completion. NOTE:- (i) Item includes the cost of 1.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr GI earth wire.
Supply & laying of LT XLPE insulated cable, sheathed, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, 1100 Volts grade, cross-sectional area 16 Sqmm 4 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
Supply & Laying sub class 'B' Bricks, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.
S&F of Galvanised Iron Pipe 40mm bore (dia) ‘light grade’ for protection of UG Cable, laid under Floors or Road Crossing, fixing to Pole with and including Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed by Engineer-in-charge.
M&L for laying 50mm dia (Outer) 3- layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply with all PP-R plain & brass threaded fittings laid in trenches/ fixed to wall and testing, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 118 here-in-above, but for 32mm dia (Outer) 3- layer PP-R pipes, complete all as specified and as directed by Engineer-in-charge.
S&F of 50mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed by Engineer-in-charge.
S&F of 32mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed by Engineer-in-charge.
SYED ATAUR RAHMAN (BID ID -3463330)
M/s DEBOJIT ROY (BID ID -3468696)
R K Enterprises (BID ID -3463014)
M/S SITAL BUILDERS (BID ID -3466374)
OM CONSTRUCTIONS (BID ID -3463125)
M/s Narzary Enterprise (BID ID -3463473)
M/S S.S. Construction (BID ID -3462940)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.08 MB
BOQ_822552.xls
BOQ • 0.71 MB
8867TENDERDOCUMENT.pdf
Tender Documents • 0.49 MB
Download all tender documents and submit your bid