AC Work under Construction Work of Sub Tehsil Building At Potla Distt- Bhilwara.
2026_CEPWD_603717_10
NIT22 2026-27 EE PWD Elec Dn Ajmer
Open Tender
Electrical Works
Percentage
270 days
Bhilwara
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
Egras Challan EE PWD Elec Dn Ajmer 7820
₹3,400
Yes
22 Oct 2026
10 Oct 2026
22 Oct 2026
10 Oct 2026
22 Oct 2026
10 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SITC of IP 54 OEM Fabricated DOL/Star-Delta Starter panel with switchgear selection as per Type-2 Coordination Chart and made out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection(for three phase pumps), Illuminated ON / OFF push buttons, ammeter, voltmeter, indicating lamps, 2P/4P MCB etc. suitable for following rating motors complete in all respect. | |||||
| 1.1 | For single phase Submersible / Monoblock pump | - | - | - | - |
| 1.2 | 0.5 HP to 1.5 HP (DOL starter) | 1 | Each | 5,643 | ₹5,643 |
| 2Supply , Installation, Testing and Commissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. Min 5 year Original Equipment Manufacturer (OEM) warranty of both compressor and Printed Circuit Board (PCB). | |||||
| 2.1 | Cooling capacity 6100- 6300 Watt, ISEER not less then 4.6 , ( 1.73 Tr to 1.80 Tr ), 5 star | 2 | Each | 53,311 | ₹1,06,622 |
| 3Supply, Fixing and testing of following capacity IS:8448 marked wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrial plug top making connection etc complete in all respect. | |||||
| 3.1 | 5 kVA | 2 | Each | 3,570 | ₹7,140 |
| 4Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia | |||||
| 4.1 | 50 mm dia per running inch length | 24 | inch | 67 | ₹1,608 |
| 5 | Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre approved by Engineer in charge. | 2 | Each | 542 | ₹1,084 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.92 MB
Tendernotice_2.pdf
PDF • 23.83 MB
Tendernotice_3.pdf
PDF • 4.91 MB
Tendernotice_4.pdf
PDF • 1.76 MB
BOQ_1070523.xls
BOQ • 0.38 MB
SanshodhanDate22.pdf
PDF • 0.81 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .