Tender Value
Refer Docs
EMD Value
₹72,000
Closing Date
10 Mar 2022, 6:00 pmClosed
GE (SOUTH) PATHANKOT
GE (SOUTH) PATHANKOT
REP MAINT LTOH LINE FDER PILAR BOX PERIMTR SECURITY LIGHTS REPR TO DG SET CAPCITOR WINDW SPLIT AC REF AC ITEMS IMPRVMNT TO EM INSTLN AT OTG BHADORIYA AND OTHR CONCTD ITEM AT DAMTAL NANGAL BHUR KANDRORI MIRTHAL KAUNTERPUR COMPLEX UNDER GE S PATHANKOT
2022_MES_507014_1
GES/PKT/T-56/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (SOUTH) PATHANKOT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (SOUTH) PATHANKOT
₹72,000
Yes
6 May 2022
9 Feb 2022
12 Mar 2022
9 Feb 2022
10 Mar 2022
24 Feb 2022
Amount
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr deep hard /dense type of soil getting out and levelling of bottom surface to required level for poles/stay assebly/cable all as specifed and directed.
All as per Srl item 1 above but exc depth 1.5m and not exc. 3m
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25m thick all as specified and directed.
Removing excavated material from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5mtr from the starting point all as directed.
M&L for Sub class ‘B’ bricks old size laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required.
Supplying & Laying in trenches clear sand for cushioning under ground cable 8 cm below and 15 cm above complete in level all as specified.
Laying only old bricks retrieved from item No.1 of any size/type laid along alignment of cable as protection to cable in trenches complete all as specified and directed.
Removing existing 1100 volts grade, XLPE/PVC, armoured, electric power cables (heavy duty) with aluminium conductor of sizes 6 Sqmm 4 core to 70 Sqmm 3.5 core from trench/ duct/ pipe carefully for identifying the defects and relaying the same after rectification of defects complete all as directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining, cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule
Supply and lay cable XLPE insulated armoured heavy duty electric cable with aluminium counductor, 1100 volts grade of crosssectional area 16 Sq mm 2 core. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule
Supply and lay cable XLPE insulated armoured heavy duty electric cable with aluminium counductor, 1100 volts grade of crosssectional area 16 Sq mm 4 core. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule
All as per Srl item 10 above but of size 25 Sqmm 3.5 core
All as per Srl item 10 above but of size 25 Sqmm 4 core
All as per Srl item 10 above but of size 35 Sqmm 3.5 core
All as per Srl item 10 above but of size 50 Sqmm 3.5 core
All as per Srl item 10 above but of size 70 Sqmm 3.5 core
All as per Srl item 10 above but of size 90 Sqmm 3.5 core
Supplying and fixing in replacement of old u/s service cable size 10 sqmm, twin core multistranded 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service with galvanised steel wire complete all as spd and directed.
All as per Srl item 17 above but of size 6 Sqmm.
Material, labour , testing & commissioning of straight through jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 10 to 16 Sqmm 3.5/4 core with working voltage 1100 volts .
Material, labour , testing & commissioning of straight through jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 16 to 50 Sqmm 3.5/4 core with working voltage 1100 volts .
Material, labour , testing & commissioning of straight through jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 25 to 70 Sqmm 3.5/4 core with working voltage 1100 volts .
Material, labour , testing & commissioning of straight through jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 70 to 120 Sqmm 3.5/4 core with working voltage 1100 volts .
Material, labour , testing & commissioning of straight through jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 150 to 185 Sqmm 3.5/4 core with working voltage 1100 volts .
Material, labour , testing & commissioning of straight through jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 95 to 400 Sqmm 3.5/4 core with working voltage 1100 volts .
Supply and fixing galvanised steel tube light grade of 15 mm dia, over the electrict pole with the help of suitable size MS clamp, passing the service cable from the busbar to the light fitting throught it, and making connection, of the cable to both the ends from bus bar to the light complete all as directed and specified.
M&L for GI pipe light grade 40 mm dia for cable protection on road crossings /plinth protection with fixed to the pole wall etc. suitable fittings for cable protection .
M&L for GI pipe light grade 50 mm dia for cable protection on road crossings /plinth protection with fixed to the pole wall etc. suitable fittings for cable protection .
Taking down defective LED street light fitting of any size/ capacity from height of pole/walls/high mast of any location exceeding 7.0 m height for repair work and re-fixing back after repair work including checking, inspecting, testing and commmissioning complete all as directed by Engr-in-Charge. Note: a) The M/L for Items like electronic drivers, surge protection devices etc shall be measured and paid separately under relevant items here in under this Schedule. b) Necessary tools like ladders & other T&P required etc shall be arranged by the Contractor. c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site.d) The M/L for repairs to LED panel is not included in the scope and shall be measured and paid separately.
Supply and fixing in replacement of Surge protection device of capacity 10 KV suitable for LED light fitting
Supply and fixing Electronic driver potted type IP-65, suitable for 200 to 300 W LED light fitting complete all as specified.
Supply and fixing Electronic driver potted type IP-65, suitable for 125 to 180 W LED light fitting complete all as specified.
Supply and fixing Electronic driver potted type IP-65, suitable for 90 to 120 W LED light fitting complete all as specified.
S&F Electronic driver potted type IP-65, suitable for 70 to 80 W LED light fitting complete all as specified.
S&F Electronic driver potted type IP-65, suitable for 30 to 60 W LED light fitting complete all as specified.
S&F in repair Electronic digital Timer (Astronomical) suitable for street light timer DB panels .
Supply & fixing in repair LED Flood light fittings on rail/ steel tubular poles of height not exceeding 7.5 mtrs, comprising of epoxy powder coated housing, enclosed with glass cover in frame, of minimum wattage 200 Watts (with total lumen output not less than 20000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) with ingress protection IP 65/66 and SPD of capacity 10 KV etc including necessary clamps etc complete and testing on completion all as specified and as directed. Note : (i) MS Clamp fittings with nut bolts and GI bracket will be measured and paid separately.(ii) Minimum 2 years guarantee period of LED fittings (iii) Driver shall be IP 66 degree of protection potted seal type with inbuilt SPD and external SPD of capacity 10 KV to be provided in addition to inbuilt. (iv) Power factor more than 0.9 (v) Contractor shall submit LM 79 and LM 80 test reports from manufacturer from approved laboratory.
Supply & fixing in repair LED street light fittings on rail/ steel tubular poles of height not exceeding 7.5 mtrs, comprising of epoxy powder coated housing, enclosed with glass cover in frame, of minimum wattage 90 Watts (with total lumen output not less than 9000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) with ingress protection IP 65/66 and SPD of capacity 10 KV etc including necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items. (ii) Minimum 2 years guarantee period of LED fittings (iii) Driver shall be IP 66 degree of protection potted seal type with inbuilt SPD and external SPD of capacity 10 KV to be provided in addition to inbuilt. (iv) Power factor more than 0.9 (v) Contractor shall submit LM 79 and LM 80 test reports from manufacturer from approved laboratory.
Supply & fixing in repair LED street light fittings on rail/ steel tubular poles of height not exceeding 7.5 mtrs, comprising of epoxy powder coated housing, enclosed with glass cover in frame, of minimum wattage 50 Watts (with total lumen output not less than 5000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) with ingress protection IP 65/66 and SPD of capacity 10 KV etc including necessary clamps etc complete and testing on completion all as specified and as directed. Note : (i) MS Clamp fittings with nut bolts and GI bracket will be measured and paid separately.(ii) Minimum 2 years guarantee period of LED fittings (iii) Driver shall be IP 66 degree of protection potted seal type with inbuilt SPD and external SPD of capacity 10 KV to be provided in addition to inbuilt. (iv) Power factor more than 0.9 (v) Contractor shall submit LM 79 and LM 80 test reports from manufacturer from approved laboratory.
Supply & fixing in repair LED street light fittings on rail/ steel tubular poles of height not exceeding 7.5 mtrs, comprising of epoxy powder coated housing, enclosed with glass cover in frame, of minimum wattage 120 Watss (with total lumen output not less than 12000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) with ingress protection IP 65/66 and SPD of capacity 10 KV etc including necessary clamps etc complete and testing on completion all as specified and as directed. Note : (i) MS Clamp fittings with nut bolts and GI bracket will be measured and paid separately.(ii) Minimum 2 years guarantee period of LED fittings (iii) Driver shall be IP 66 degree of protection potted seal type with inbuilt SPD and external SPD of capacity 10 KV to be provided in addition to inbuilt. (iv) Power factor more than 0.9 (v) Contractor shall submit LM 79 and LM 80 test reports from manufacturer from approved laboratory.
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 60 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 7200 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 72 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 7200 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 100 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 12000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 150 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
Supply & fix replacement decorative path way light lighting LED decorative post top lantern for 360 degree 40 watts 230 volts, 50 HZ, maple shaped in sothing opal/ prismatic finish made up of polycarbonate,including all accessories prewired complete.Note :- (i) Minimum 2 years gaurntee period of LED fittings (ii) Driver shall be IP 66 degree of protection potted seal type. (iii) Power factor more than 0.9
Taking down old unserviceable street light fittings from any height and Supply & Supply & fixing LED street light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,with lumen output not less than 9000 lumens suitable wattage for efficiency not less than 100 lumens/Watt,min wattage 90 watt, with ingress protection IP 65 and SPD of capacity 10 KV etc complete and testing on completion all as specified and as directed. Note: The GI pipe if rquired bracket will be measured and paid separately under relevant schedule items
Supply and Fix in replacement existing UNSV tube light fitting with LED 20W inverter batten type fitting 4 feet long aluminium extruded housing,IP-20 ,rated voltage 230 V, 50 hz, charing time 10-12 hours and backup time 04 hours system wattage 20W +/- 10%, system current less than 102 mA, power factor more than 0.95, system lumen efficiency 100lm/watt,CCT 6500K, CRI more than 80, THD less than 30%, driver efficiency more than 85% complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or directed.
Supply and fix bldg security light fittings with LED security light fittings 60 watt, IP 65 having pressure die cast aluminium alloy housing, prismatic polycarbonate cover complete including making connection with 3 core copper flexible cable of suitable size including galvanised iron pipe bracket 0.90 mtr long of 25 mm dia and fixing with bldg for fixing of street light fitting all as directed. Note: (i) Driver Efficacy – more than 85% ( constrant current driver).(ii)Driver Type – Potted (iii) THD - < 10% (iv)Led Driver Current – less than 750 mA(v) Efficacy of Led Fixtrue – 100 lm/watt ( minimum) (vi) Efficacy of Led Chip – more than 130 lm/watt( Vii) Surge Protection – 4 KV & above as per IEC standard inbuilt in Driver and External SPD 5KV (vii) Working Humidity - 10% to 90% RH (ix) Led Make – Nichia/Philips Lumiled/ Cree /Osram/ Seoul (x) Life – 50,000 hours at 70% lumens(xi) CRI – more than 70 (xii) Lens – Each Led shall be of High Power ( 1 to 3 watt only) with mandatory modular lens. (xiii) Working Temp – 0 to 50 degree C. (xiv) Heat Sink – Pressure die cast aluminium (xv) Junciton Temp – 100 degree C (xvi) Body of Fitting – Pressue Die Cast with company logo / make engraved or embossed in housing LM 6 Grade.(xvii) Impact code – Min IK05 or more (xviii) LM79 report from Third Party ( instead of company in house lab) NABL /UL accredited lab. (xix) LM80 report from Led Manufacturer.(xx) Low/High voltage, reverse polarity, overload and short circuit protection inbuilt in fixtrue.(xxi) MS Clamp fittings with nut bolts and GI bracket, junction box included in the rate.(xxii) Test certificates to be submitted before commencement of work/ claiming for payment .(xxiii) Warranty certificate for minimum 2 years to be submitted from OEM.
Supply and erect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-11 (11.0 metres long) all as directed incl dismantling old one. NOTE :- Earth work, Cement concrete in foundation, coping etc will be measured and paid separately under relevant item.
Supply and erect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) all as directed incl dismantling old one. NOTE :- Earth work, Cement concrete in foundation, coping etc will be measured and paid separately under relevant item.
Earthing complete with Galvanised Steel earthplate of size 60x60cmx6.3mm thick electrode and GI wire 8 sqmm dia as earth lead, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to earth wire 4 sqmm by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I, including testing on completion (Rates inclusive of neccessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground etc. all as required at site for complete earthing).
M&L for Galvanised iron round bracket made out of 40mm dia GI tubing including making provision for fixing of 04/06 no flood light on 11 mtr steel tubular pole ad fixing and connecting up of LED lights (LED lights shall be measured seperately under respective items of sch ) complete all as specified and directed. Note: The inner diameter of ring shall not be less than 1.0m
S&F in repair PVC insulated 3 core 2.5 Sq mm stranded Aluminium conductor cable for connecting OH line/junction box to street light fitting testing and commissioning all as directed.
Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings all as directed.
M&L for bracket for street light fitting made out of 40 mm bore pipe light grade GI tube bent to shape required, not less than 1.20 meter long, fixed with and including MS flat iron clamps made out of 40x6 mm FI, bolts, nuts, washers etc complete including dismantling old defective.
M&L for bracket for street light fitting made out of 25 mm bore pipe light grade GI tube bent to shape required,not less than 1.20 meter long, fixed with and including MS flat iron clamps made out of 40x6 mm FI, bolts, nuts, washers etc complete including dismantling old defective.
S&F in repair powder coated Mild steel junction box wtih MCB SP 03-10 Amps-01 No outdoor type , CRCA sheet with front openable hinged door , locking arrangements with 4 Nos Aluminum bus bars , 200 Amps, mounted on porcelain insulator, glands and lugs etc. and fixed to pole/ PTL post etc with suitable size flat iron clamps, nuts, bolts complete including taking down all as specified and directed.
S&F in replacement of bus bar chamber including taking down with MCB SP 10-16 Amps-01 No outdoor type made out of MS sheet 3mm thick with copper bus bar three phase & neutral fixed with insulators and fixing on pole with proper clamps, nuts , bolts & washers of required size and making connection of LT cables with thimbles and making good the disturbed wall surfaces incl water proof PVC sticker like danger mark all as required at site.
Scraping of old paint from the HT/LT pannel/bus bar fixed along PCC plinth without removing and preparation of surfaces for repainting externally. Repainting the bus bar /pannel complete externally by applying one coat of synthetic enamel paint incl fencing jali of approved colour and also repainting the plinth as per directed
M & L for insulation mat 3.3 KV ISI suitable LT panel complete all as specified and as directed.
Restretching of ACSR conductor of any size of over head lines LT/HT on poles including binding with insulators, jointing jumpers etc including connections of incoming and out going cables complete all as specified and directed. Note: ACSR conductor Required for winding etc to be included in quoted rates.
Dismantling unserviceable cross arms including clamps, bolts, nuts, washers etc from pole.
Supply, fabricate and fix cross arms any size along with, brackets, clamps, bolts, nuts, washers, bracers etc including drilling holes, cold/hot complete and fixed to pole including one primer coat and one under and finishing coat of paint.
Dismantlin of ACSR conductor of any size, from insulator etc from the structure/over head line all as directed.
M&L replacement of ACSR conductor of any size as ordered by Engr-in-charge including tightening and bindingh with new binding wires to insulators all as directed.
Dismantling insulators any type, size
M&L pin type insulator vitreous, white, brown, or green insulator includig one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 100 mm height, 65 mm dia for 1100 volts grade.
Material & labour for fixing in repairs Stay assembly complete with accessories such as MS stay plate of size 300mmx300mmx6mm thick, stay rod 20mm dia, stay bow, nuts, bolts and check nuts of GI including GI stay strand of size 7/4 mm all as shown in electrical plate No. 1 of SSR Part-I of 2009 or directed by Engr-in-charge. Note: Earth work ( Excavation, Returning & refilling and removal), PCC, stay clamp and loop type insulators will be measured and paid separately under relevant schedule items).
Taking down old burnt out MCCB (of any size, make ,shape ) and supply and fixing new MCCB with the existing cable after making it good by cutting out the burnt parts of the cable/lugs, crimping new lugs as per the suitable size, connecting with the new MCCB along with spraders, testing complete all as directed and specified
MCCB 04 pole of 250 current rating with rapturing capcity of 35 KA, 415V, 50Hz, (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100% complete all as specified
MCCB 04 pole of 160 A current rating with rapturing capcity of 25 KA, 415V, 50Hz, (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%, complete all as specified
MCCB 04 pole of 125 A current rating with rapturing capcity of 25KA, 415V, 50Hz, (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100% complete all as specified
MCCB 04 pole of 100 A current rating with rapturing capcity of 25KA, 415V, 50Hz, (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100% complete all as specified
MCCB 04 pole of 200 A current rating with rapturing capcity of 25 KA, 415V, 50Hz,(Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%, complete all as specified
MCCB 04 pole of 63 A current rating with rapturing capcity of 16 KA, 415V, 50Hz ,(Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%, complete all as specified
Disconnecting and removing existing unserviceable battery and S&F maintenance free battery 12V 180 AH including terminal clamps, copper lead 3m long each including testing and commissioning all as directed by Engineer-in-Charge.
S&F in repairs of MCCBs of following current carrying capacity including necessary connecting terminals to bus bar, nut bolts etc complete all as directed .
4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 200-250 A rated
4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 160-200 A rated
4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 125A to 160 A rated .
M & L for replacement of unsv/broken thermoplastic polycarbonate spring type locks suitable for panel locking (Mi DV 01 with Mi SR 4) complete.
M&L for PCC 1:4:8 type D2 with 40 mm graded aggregate as in foundation complete.
M&L for PCC 1:3:6 type C1 with 20 mm graded aggregate for coping of poles and stay including form work.
Plain cement concrete (1:2:4) type B-2 (Using 20 mm graded stone aggregate) for foundation coping complete all as specified
S&F loop-in/loop-out box of outer size size 250x 210x 115 mm made out of FRP(Hot moulded type) with weather proof canopy and locking screws along with with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed to to steel tubular/ rail/ PCC/RCC pole using 25 x 3mm FI clamp, including suitable gland and lugs for connecting cable complete all as directed including dismantling old one.
M&L for preparation of old painted steel surfaces of 9 m long steel poles incl removing oily/greasy spots and applying one coat of aluminium paint complete including applying a coat of white wash on pole coping and lettering the pole details with white letters/ blackground etc complete all as directed
Repairs to High Mast/mid mast pole motor of Capacity 1.0 HP/0.75 KW 415 Volts 50 Hz 3 Phase 930 RPM and necessary rewinding with super enamelled copper wire all as per existing and servicing/ greasing of reduction gear box complete all as specified and as directed.
Decarbonising of the control panel of High mast/ Mid mast and including sevicing of parts such as contactors/ timers including replacement of pitted lugs,thimbles, control wiring etc complete including painting with a coat of synthetic enamel paint
M & L for preparation of old painted surfaces of 09/11 m long steel poles incl removing oily/greasy sports and applying one coat of aluminium paint complete above 1.5 mtr and one coat of synthetic enamel paint of black and yellow in alternate strip of 30 cm witdth upto 1.5 mtr height including applying a coat of white wash on pole cooping and lettering the pole details with white letters/black background etc complete all as directed
M & L for preparation of old painted surfaces of 09/11 m long PCC poles incl removing oily/greasy sports and applying one coat of synthetic enamel paint of black and yellow in alternate strip of 30 cm witdth upto 1.5 mtr height including including applying a coat of white wash on pole cooping and lettering the pole details with white letters/black background etc complete all as directed
S & F in repair 3 pole power contactor with coil voltage 230 volt AC of current carring capacity 32 to 40 Amps complete including control wiring thimbles etc complete all as directed.
M&L for replacement of acrylic sheet instructions for pump operation in Hindi/Punjabi all as specified size of display not less than 2.0x1.0 ft with all decoration as specified.
M&L for fire point comprising of the following. (a) CO2 fire extinguisher 4.5 Kg (02 Nos), b) Dry carbon powder (ABC)-05 Kg (02 Nos) ,ceiling Hook,fire beater,sand buckets 9 mtrs capacity-02 Nos ,Showel complete with angle iron stand duly painted with two coats of synthetic enamel paint of approval colour over a coat of red oxide primer incl dismentling old unsv one.
M & L for laying stone graded coarse aggregate of size 40 mm for foundation filling at sub station two pole/ four pole complete all as specified and directed by engr-in charge.
M & L for laying stone graded coarse aggregate of size 20 mm for foundation filling at sub station two pole/ four pole complete all as specified and directed.
Material & Labour for taking down the defective split/ Window unit of the following capacity, shifting to work shop, taking out the defective unserviceable hermetically sealed compressor from the unit, replacing the compressor with new compressor of the same capacity, fixing to the unit inter connecting the refrigerating lines, flushing out the cooling coil & condenser, removal the coil & carbon thoroughly, cleaning with CTC, leak testing, pressure testing with Nitrogen gas, dehyderating, Vaccumissing, charging of Refrigerant gas, testing at work shop. Shifting to the location reinstalling the same in its Original position connecting up all etestion electrical, connection and Testing & Commissioning. All as specified as directed by Engineer-in-Charge.
1.5 TR Capacity
2 TR Capacity Note : Rate quoted is deemed to be inclusive of cutting, welding, brazing, sealing the refrigerant tubing, replacement of strainer, CTC, Nitrogen gas, Refrigerant gas, required to and from Transportion and Handling. M/L for spares will be measured and paid separately
Material and Labour for taking down the damage condenser fan blade of 1.5TR split/Window type AC’s of any make and supply & fixing suitable new fan blade and testing & commissioning the unit.
All as per Item 99 above But 2 TR Split AC
Material and Labour for taking down the damaged blower unit of any make split/Window AC and supply and fixing of new blower unit of suitable type and testing & commissioning the unit.
Material and Labour for complete scraping out the crusting painting of the complete body of out door unit metallic surface, cleaning the surface thoroughly, apply putty / metal paste, prepare the surface, apply 2 coat of synthetic enamel paint over a coat of red oxide primer for 1.5 / 2TR capacity split type AC’s.
Material and Labour for cleaning flushing the refrigeration system thoroughly with CTC, and Nitrogen gas, leak testing and locating the leaks, rectifying the leaks, by brazing the joints, replacing the damaged copper pipes, silver rod/ copper. Pressure testing, dehydrating, vaccumissing, gas charging testing & commissioning the system the work includes required strainer, N2 gas, Refrigeration gas and transportions Handling the unit. All as specified as directed by Engineer-in-Charge.
1.5 TR Capacity
2 TR Capacity
Material and Labour for taking down the unserviceable temperature sensor probes and supply & fixing new sensor probe suitable for any type, make split/Window type AC’s and testing & commissioning.
Material and Labour for taking down the defective unserviceable printed circuit Board and S/F of new printed circuit board for any make split/window type AC unit.
Material and Labour for taking down the defective unserviceable sealed fan motor & S&F new fan motor of the same capacity & size to suit the split/window AC unit of any make and capacity of 1.5 / 2 TR all as per existing at site
Material and Labour for taking down the damaged air filter set and S/F of new air filter set for split/window type AC’s of 1.5 / 2TR capacity.
Material and Labour for taking down the defective unserviceable starting/running capacitors 80/100 MFD 230V / 50Hz and supply and Fixing the new starting capacitor of the same capacity to split / window type AC’s and testing.
Material and Labour for taking down the defective unserviceable starting relay and supply and fixing new rely suitable for 1.5/2TR Window / Split type AC’s and Testing.
Material and Labour for taking down the defective unserviceable Thermostatic switch and S/F new thermostatic suitable for window type AC’s and Testing.
Material and Labour for taking down the damaged drain pipe and S/F of new insulated drain pipe suitable for split type AC’s.
Material and Labour for taking down the defective capillary tube set and supply & Fixing new suitable capillary set for split type AC’s.
Material and Labour for taking down the rusted out door unit stand and supply & fixing the stand with required anchor fastner and nut & bolts and rubber bushes for 1.5 / 2 TR Split unit.
Material and Labour for taking down the burned out door unit fan motor and rewinding, overhauling renewal of worn out shaft & bushes, and fixing to the unit, of 1.5 / 2 TR Split units.
Material and Labour for taking down the defective remote control unit and S/F of new remote control unit for split/ window type AC of 1.5 / 2 TR of any make and testing.
Material and Labour for taking down the defective definite purpose magnetic contactor of the split/ window AC’s of any make, and supply & fixing of new contactor of 240 VAC. 30 Amps 50 Hz, and coil volt of 208/240V 50/60Hz and Testing.
Material and Labour for taking down the defective unserviceable sealed motor of indoor unit of any make split unit of 1.5/2 TR capacity and S/F new fan motor suitable for Split type AC’s.
Material and Labour for taking down the defective starting capacitor of split / window type AC’s and supply & fixing the new starting capacitor of 80/100 MFD 230V, 275SV-50Hz and Testing for 1.5/2TR AC Unit.
Material and Labour for taking down the burned wiring kit and supply & fixing and testing of new wiring kit suitable for 1.5/2TR split and window type Ac unit.
Material and Labour for taking down by disconnecting water connections and shifting elective water cooler to work shop, taking down the defective sealed compressor and replacing with new compressor, the work includes flushing the complete system condenser, cooling coil with Nitrogen, removal all carbon, oil & dirt, brazing & inter connecting the refrigeration lines, de-hydrating, purging with refrigerant, vaccumissing and charging of R22/ 134a Refrigerant and testing & commissioning and shifting to original location and connecting up the electrical & water connection for the following capacity water coolers. All as specified as directed by Engineer-in-Charge.
40/60/80 Ltrs. capacity water cooler
120/150 Ltrs. capacity water cooler
Material and Labour for complete tinkering the corroded sheet metal parts, side panel, door, with existing gauge M.S. Sheet and renewal of the bottom base plate, mounting lets, fan motor base plate, and condenser should cover etc., with existing size gauge G.I. sheet, with required Angle Iron, Nut & Bolts all as per the existing size and shape including cutting, bending, welding and completing fixing all other components, complete scraping with old paint, prepare the surface, painting 2 coat of enamel paint over a coat of primer and complete cleaning the water tank and shifting to the location and testing any capacity of water coolers. All as specified as directed.
Material and Labour for charging the water cooler of the following capacitor including taking down, transporting to workshop flushing out the cooling coil, condenser, brazing the refrigerant lines, replacing of liquid line copper strainer, leak testing, purging with refrigerant, vaccumissing and charging of R22/R 134a gas, testing & commissioning and shifting to the location and connecting up the electrical & water connection. All as specified as directed.
40/60/80 Ltrs. capacity water cooler
120/150 Ltrs. capacity water cooler
Material and Labour for painting the water cooler including scraping out the old paint prepare the surface, painting 2 coat of enamel paint over a coat of primer, the work including necessary putty, metal paste etc., and disconnecting from the position and refixing after painting for any capacity of the water coolers.
Material and Labour for to the water cooler tank and cooling coil by dismantling the water cooler and carried out the lead soldering to cooling coil to the tank outer surface where ever the detached portion and rectify the leaks portion and re-assembly the water cooler of any capacity.
Material and Labour for taking down the damaged thermal insulation of the water cooler, and renew the thermal insulation as per the existing thickness and assembling the body with necessary sheet metal screws etc., for any capacity water coolers.
Material and Labour for taking down the defective starting relay and S/F of new starting relay for any capacity water cooler.
Material and Labour for taking down the defective overload relay and S/F of new over load relay suitable for any capacity water cooler.
Material and Labour for taking down the defective Running capacitor and Supply & Fixing new running capacitor 20/10 MFD, 440 VAC 50/60 Hz suitable water cooler.
Material and Labour for taking down the defective starting capacitor and Supply & Fixing new starting capacitor 60/80 MFD, 230V, 270SU-50 Hz for water cooler upto 120 Ltrs. Capacity.
Material and Labour for taking down the defective Running capacitor and Supply & Fixing new running capacitor of 25/36 MFD, 440 VAC, 50/ 60 Hz suitable for 150 Ltrs. Capacity water cooler.
Material and Labour for taking down the defective thermostatic switch and Supply and Fixing of new thermostatic switch for water coolers.
Supply and Fixing of Left/Punch cook for water cooler of any capacity.
Supply and Fixing float valve for water cooler of any capacity
Material and Labour for taking down the damaged drain connections and drain pipe and S/F of new drain connection & pipe with necessary clamps, Nipple, coupling etc., for any capacity water cooler.
Material and Labour for taking down the defective unserviceable sealed fan motor and S/F new fan motor with suitable capacitor for water cooler upto 40/80, 60/120 ltrs. Capacity.
Material and Labour for taking down the damaged condenser fan blade and supply and fixing of new fan blade suitable for 40/60/80 water coolers.
Material and Labour for taking down the corroded air cooler condenser and supply and fixing of new air cooled condenser with necessary brackets and fixing arrangements including welding brazing etc., for water cooling 40/60/80 Ltrs. Capacity.
Material and Labour for taking down the complete corroded sheet metal body of out door unit of split unit and supply and fixing of new out door unit suitable 1.5 TR split unit the work includes dismantling the components and reassembly and fixing to the existing location and testing for any make of split unit.
Material and Labour for taking down the complete corroded sheet metal body of indoor unit of split unit and supply and fixing of new indoorunit suitable 1.5 TR split unit the work includes dismantling the components and reassembly and fixing to the existing location and testing for any make of split unit.
Material and Labour for taking down the corroded air cooled condenser and supply and fixing of new air cooled condenser suitable for 1.5 TR Split Ac
Material and lbour for taking down complete old corroded, unserviceable window AC of 1.5 Ton capacity and depositing to MES Store and supply and fixing a new window AC of 1.5 Cpacity
M & L submain wiring with 4.0 Sq.mm (nominal area) PVC unsheathed multi strandard copper conductor PVC insulated 1100 volt grade single core cable drawn through and including rigid PVC conduit medium grade minimum 20mm size and its accessories complete along with 4.0 Sqmm cable but in green colour as continuous earthing wire and connecting to common earth dolly completely concealed ,surface,in walls/ceiling/roofs all as directed and specified including dismantling old one Note : Three runs of PVC copper cable and one run of PVC conduit will be measured as one Rm.
Material and Labour for complete carryout the servicing to Split/Window type AC’s including taking down from the position, dismantling the sheet metal parts, blowing out the dust, carryout the chemical cleaning to chocked cooling coil & condenser coil, by spray the dilated chemical cleaning agent, till remove complete chocking, flushing across the coils, cleaning all the sheet metal parts, filter, grill and fixing all the dismantled parts with sheet metal screws, lubricating the fan motor bush / bearing, checking all the electrical connections, renew any burned legs / clip and fixing back to position and testing.(Note: Gas Charging if required will be measured and paid seperately).
Supply and charging refrigerant R-22 complete one time for topping up or making full qty including plugging the leakage complete and as directed.
Supply and charging the refrigerator gas R-134A / R-34A /R-407/any environmental friendly refrigerant gas complete all as specified and as directed.
Supply and charging compressor oil suitable for AC's, water cooler ,Refrigerator and deep freezer complete including testing etc, complete all as specified and as directed.
Removing the old paint of the body of refrigerator of any capacity and making the body dent proof and preparing the surface and Painting the refrigerator with 2 coats of synthetic enameled paint of superior quality to match with existing paint with spray painting complete all as specified and directed.
S & F in replacement Refrigirator of capacity 310 Ltrs complete
S&F in replacement of existing UNSV sealed Compressor unit for Refrigerator of capacity 165 to 185 Ltrs including Gas charging.
S&F in replacement of existing UNSV sealed Compressor unit for Refrigerator of capacity 285 to 320 Ltrs including Gas charging.
S&F in replacement of existing UNSV cooling Thermostat switch suitable for refrigerator/deep freezer of any capacity.
S&F four layered Rotational moulded polyethylene water storage tanks of capacity 5000 Ltrs (cylindrical vertical with closed top) hoisted and fixed in position coplete including dismantiling of old one al as specified as directed.
S&F in repair Capacitor duty contactor with 1 No Aux contact 230V AC coil voltage suitable for minimum 10 KVAR capacitor.
S&F in repair Capacitor duty contactor with 1 No Aux contact 230V AC coil voltage suitable for minimum 25 KVAR capacitor.
S&F in repair Double metalised paper and polypropylene technology ( Mixed Dielectric) capacitor cylindrical/box type for power factor correction of 440 V, 50 HZ rated of capacity 3 to 15 KVAR.
S&F in repair Double metalised paper and polypropylene technology ( Mixed Dielectric) capacitor cylindrical/box type for power factor correction of 440 V, 50 HZ rated of capacity 20 to 25 KVAR.
M&L in replacement of existing unserviceable cantactor of current carring range 25 A to 40 Amp (AC-3 duty) at different places in APFC panels including required electrical connections with suitable size of single core pvc copper cable & testing all as directed.
M&L in replacement of existing unserviceable contactor current carring range 9 A to 18 Amp (AC-3 duty) at different places in APFC panels including required electrical connections with suitable size of single core pvc copper cable & testing all as directed .
M&L in replacement of existing unserviceable MCB 25-40 Amps TPN 415 volts at different places in LT Panels/APFC panels including required electrical connections & testing all as directed .
M&L in replacement of existing unserviceable MCB 32 - 63 Amps TPN 415 volts at different places in LT Panels/APFC panels including required electrical connections & testing all as directed .
S&F in repair APFC relay with inbuilt PF meter suitable for 5A CTR suitable for 8 Stage.
S&F in repair APFC relay with inbuilt PF meter suitable for 5A CTR suitable for 12 Stage.
All as per Item 170 above, but capacity 30 KVAR with incoming MCCB of capacity 63 Amps 4 pole (6x5)
All as per Item 170 above, but capacity 40 KVAR with incoming MCCB of capacity 80 Amps 4 pole (8x5)
Maintenance and servicing of DG set consisting of replacement of fuel filter, air filter and lub oil filter including replacement of eninge oil all as directed and testing on full connected load for the following capacity of DG Sets and any make as per OEM.Note: Engine oil will be measured and paid seperately.
DG Set 10 KVA to 20 KVA
DG Set 25 KVA to 50 KVA
DG Set 62.5 KVA to 75 KVA
M & L for replecement of existing unservicible Fan Belt and testing complete for the following capacity of DG Sets and any make as per OEM.
DG Set 10 KVA to 20 KVA
DG Set 25 KVA to 50 KVA
DG Set 62.5 KVA to 75 KVA
M & L for replecement of existing unservicible Hose Pipes with clamps and testing complete for the following capacity of DG Sets and any make:
DG Set 10 KVA to 20 KVA
DG Set 25 KVA to 50 KVA
DG Set 62.5 KVA to 75 KVA
Taking out the old unserviceable radiator from the DG set and taking it to work shop for overhauling & cleaning descaling with restore plus solution, removal of leakage, welding brazing & refixing it duly repaired etc complete all as directed for the following capacity of DG Sets and any make as per OEM.
DG Set 10 KVA to 20 KVA
DG Set 25 KVA to 50 KVA
DG Set 62.5 KVA to 75 KVA
M/L for cleaning the fuel tank both internally and externally by removing all the dust / sediments etc including replacement of PVC pipe fuel level indicator, writing of tank capacity, date of cleaning and next due date for tank to be cleaned for following capacities of DG Set and any make as per OEM.
DG Set 10 KVA to 20 KVA
DG Set 25 KVA to 50 KVA
DG Set 62.5 KVA to 75 KVA
Supply and fix in repair including testing, commissioning and calibration of Fuel consumption meter of any size and make suitable for DG set 10 KVA to 125 KVA
M & L for scrapping of old paint from DG set 10 KVA to 20 KVA and preparation of old painted surfaces for re-painting. Repainting complete body of DG set with superior quality super enamelled paint of colour as per standard engineering practice for engine, alternator, base frame etc by sparying including writting SM/MES No, all as specified and directed.
M&L for repair and overhauling of unsv self starter 12 V of any capacity DG set including repair/ replacement unsv/defective spares such as field coil, armature winding, carbon bushes, clutch bushes and pinion assy complete all as specified and directed.
M&L for repair and overhauling of unsv dynamo/ alternator 12 V of any capacity DG set including repair/replacement unsv/defective spares such as field coil, armature winding, carbon bushes, clutch bushes and pinion assy complete all as specified and directed.
S&F in repair AVR with functions to adjust generator output voltage, prevent voltage hunting, set under frequency roll off knee point, set generator droop to 5% at full load, match AVR input to accessory output, set the over excitation cut off level, set intial frequency related voltage dip, over-voltage protection cut off level, maximum short circuit current with sensing input voltage range 170 - 250 V AC max, 50 -60 HZ frequency with output max upto 120 V DC, continuous current 2.7A & transient 6A for 10 sec including necessary control wiring complete from alternator to AVR complete testing & commissioning for DG sets of capacity 10.5 to 25 KVA.
All as per srl item 198 above but for DG set capacity 50 to 75 KVA
Taking out the old unserviceable battery from the DG Set and supply and fix new 12 V, 180 AH maintenance free battery make Amron/Exide including testing and commissioning complete all as specified and directed
Taking out the old unserviceable battery from the DG Set and supply and fix new 12 V, 100 AH maintenance free battery make Amron/Exide including testing and commissioning complete all as specified and directed
M & L for repair of Water pump of 10.5 to 25 KVA DG set including replacement of defective unsv spare part of any make and model and refix the same after repair complete all as specified and as directed
M & L for repair of Water pump of 50 to 75 KVA DG set including replacement of defective unsv spare part of any make and model and refix the same after repair complete all as specified and as directed
M&L for Calibration of Fuel pump including replacement of unsv/defective spares of 10.5 to 25 KVA KVA DG Set of any make and model complete all as directed.
M&L for Calibration of Fuel pump including replacement of unsv/defective spares of 50 to 75 KVA DG Set of any make and model complete all as directed.
M&L for overhauling and calliberation of fuel injector assembly including replacement of unsv/defective spares of 10.5 to 25 KVA DG Set of any make and model complete all as directed.
M&L for overhauling and calliberation of fuel injector assembly including replacement of unsv/defective spares of 50 to 75 KVA DG Set of any make and model complete all as directed.
Supply and fix in replacement battery leads set, PVC insulated multisranded, copper conductor of min size 35 sqmm 1m long each duly fixed with brass clamps, copper lugs suitable for DG sets of different capacities.
M/L for replacement of coolant for radiator for DG set at various locations.
M/L for replecement of Lub Oil (Engine Oil) of grade 20W40 for Engine for DG set at various locations.Make: Servo/HP/Indian Oil.
M & L for replacement of starter ring gear assembly for capacity 50 to 75 KVA DG set.
Note for all items: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
M/S SATPAL AND BROTHERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .