Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.7 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹26.5 L+₹2.3 L (9.41%)Rejected-Finance | L2 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 3 | L3₹26.8 L+₹2.5 L (10.4%)Rejected-Finance | L3 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 4 | L4₹26.8 L+₹2.6 L (10.7%)Rejected-Finance | L4 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 5 | L5₹27.0 L+₹2.7 L (11.2%)Rejected-Finance | L5 | Rejected-Finance HIGHER THEN L1 BIDDER |
Tender Value
₹24.3 L
EMD Value
₹49,000
Closing Date
14 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
HQ 136 WORKS ENGINEERS PIN - 914136 C/O 99 APO
SPECIAL REPAIR TO BLDG NO D-17 OF RAJPUT AT DALAPCHAND UNDER GE 867 EWS
2023_MES_579950_2
CWE/136-WE/58 OF 2022-23
Open Tender
Civil Works
Item Rate
240 days
Kalimpong
Class E, Category a(i)
9 documents required · 9 mandatory
₹500
GE 867 EWS
₹49,000
24 Apr 2023
30 Mar 2023
15 Apr 2023
30 Mar 2023
14 Apr 2023
8 Apr 2023
30 Mar 2023 - 4 Apr 2023
Amount
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.
S&F of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
S&F of pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and directed.
S&F of 150mm dia mild steel sheet (Thickness of sheet 1.25 mm) eaves gutters, galvanised class 3, half round with rounded edges, all as specified and directed.
S&F of 150mm dia mild steel sheet (Thickness of sheet 1.25 mm) Drop ends (for spigot or socket ends) or nozzles, all as specified and directed.
S&F of 150mm dia mild steel sheet (Thickness of sheet 1.25 mm) Stop ends (for spigot or socket ends), all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
S&F of bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, all as specified and directed.
S&F of rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe 410 -W (Gde- E- 250) quality- A, all as specified and directed.
Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing, all as specified and directed.
M&L for pre-cast cement concrete block masonry (1:3:6), type C-1 (using 20mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar (1:6), complete all as specified and as directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for, all as specified and directed.
M&L for reinforced cement concrete (1:2:4) (nominal mix), type B-1 (20 mm graded stone aggregate) in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and directed.
Use & waste of timber formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. rough finished flat surfaces of concrete, complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified and as directed.
M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified and as directed.
Taking down cement or cement lime plaster, any description on brick or stone masonry surfaces of walls etc including raking out joints, hacking for key, scrubbing down with water etc., complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces, complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces with water proofing compound, finished even and fair, complete all as specified and directed. Note: Water proofing compound will be measured and paid separately
Supply only integral water proofing compond, all as specified and as directed.
M&L for two coats of distemper oil emulsion (OBD), over a coat of priming coat (Chalk whiting, on plastered surfaces, preparatory to distempering) on newly prepared wall surfaces, including 3mm thick wall care putty on wall, all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
M&L for light shade virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tiles over and including 15mm thick screed bed or bedding layer in cement mortar (1:6), complete all as specified and directed.
M&L for light shade virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, on vertical surfaces such as skirtings, dados and risers to steps etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tiles over and including 10mm thick rendering in cement mortar (1:4), complete all as specified and directed.
Demolition of stone slabs and tiles laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc., complete all as specified and as directed.
M&L for 75mm thick plain cement concrete(1:4:8), type D-2, (using 40mm graded stone aggregate) as in sub-base, sub-floors, floors, pavings etc., all as specified and as directed.
M&L for chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and no pigments over and including 15mm thick screed bed or bedding layer in cement mortar (1:6), complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and directed.
M&L for 75 mm thick plain cement concrete(1:3:6), type C-2 (40 mm graded stone aggregate) as in floor, plinth protection, hard standing, paving etc., complete all as specified and directed.
M&L for plain cement concrete(1:3:6), type C-2 (using 40 mm graded stone aggregates) in surface channels and drains. complete all as specified and as directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds mitered / stopped ends etc., all as specified and directed.
Dismantling timber scantlings 40 Sqcm and over in section, in any position (framed work), all as specified and directed.
M&L for well seasoned second class hard wood timber scantling (clean sawn) in timber framed and fixed work, complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets, complete all as specified and directed.
S&F of Gl frame work (Size of grid 605 x 605mm) for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre, complete all as specified and directed.
S&F of hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long for grid sized 605 x 605mm, complete all as specified and directed.
M&L for 4mm thick asbestos cement plain building boards, fixed to timber framework / GI snap grid framework with screws in ceiling, complete all as specified and directed.
M&L for preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash in ceiling, complete all as specified and directed.
Taking down chowkhats or frame not exc 1.50 sqm each with shutter (without taking off shutters from the frame), complete all as specified and directed.
Taking down chowkhats or frame exc 1.50 and not exc 4 sqm each with shutter (without taking off shutters from the frame), complete all as specified and directed.
S&F of steel window with side hung shutter, including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and directed.
S&F steel window with side hung shutter, including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded, complete all as specified and directed.
S&F of mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed.
S&F of 3.0mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, complete all as specified and directed.
S&F of pressed steel frame of size 165 x 60mm for door with one or more rebates including necessary fixing, lugs, hinges, lock, strike plate etc., complete all as specified and directed.
S&F of 30mm thick flush door shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as specified and directed.
M&L for second class hard wood, 30mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, complete all as specified and directed.
S&F of galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and directed.
S&F of 140 mm long (overall length of cover plate) floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, all as specified and directed.
S&F of 200mm long aluminium anodised, barrel tower bolts of extruded section and fixed, all as specified and directed.
S&F of 150 mm size aluminium handles, cast type, anodised and fixed, all as specified and directed.
S&F of 300 mm long aluminium alloy, anodised sliding door bolts with haps staple (bolt type), and fixing clips of sheet, cast or extruted sections and fixing bolt and sliding bolts of extruted sections or cast aluminium alloy and fixed, complete all as specified and directed.
S&F in repairs of 20mm dia harrison rails (curtain rails), mild steel, chromium plated with fixing brackets, stops, rollers etc., all as specified and directed.
M&L for preparation of old wood or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with one coat of creosote oil, complete all as specified and directed.
M&L for preparation of old steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and directed.
M&L for preparation of new steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer, complete all as specified and directed.
M&L for preparation of new wooden surfaces or wood based surfaces of any description over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
S&F of 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed.
S&F of 110mm bore PVC (SWR) bends any radius, complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and directed.
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 20mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring, for one light point or one fan point or one bell point controlled by one switch, with 1.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 20mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring, for one 3 / 5 pin switch socket / socket outlet, 5 Amps on independent board, with 1.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.
Material and labour for point wiring with 4.0 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 25mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring, for one metal clad enclosure for geyser outlet or one 3 / 5 pin switch socket / socket outlet, 16 Amps on independent board, with 4.0 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.
M&L for switch socket combination 2 in 1, 5/6 Amps flush type, 240 Volts, all as specified and directed.
M&L for switch socket combination 3 pin, 16 Amps flush type, 240 Volts, all as specified and directed.
M&L for switch piano, flush type single pole, one way 5 Amps, 240 Volts, all as specified and directed.
M&L for ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body, three terminal, 240 Volts, all as specified and directed.
Supply and fixing of LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, all as specified and directed.
S&F of LED light fitting 1x9 Watt / 1X10 Watt bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, all as specified and directed.
M&L for lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed.
S&F of LED retro fit lamp B-22 holder base with poly carbonate body and aluminium heat shrink of 5 Watt complete with tube rod, all as specified and directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm × 60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron or steel earth lead wire 4.0mm dia size by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES SSR Part-I, connected to earthing test point all as specified or indicated including testing on completion, including necessary excavation and earth work in any type of soil, GI pipe 20mm dia light grade for watering and GI 15mm dia light grade pipe for protection of earth wire etc. upto test point, PCC (1:3:6) chamber with RCC cover in cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) reinforced with 8mm dia TMT bar 15cm C/C and suitable handle of 10mm dia round bar, funnel, wire mesh, charcoal dust, salt etc., connected to DB as indicated, complete all as specified and as directed. Notes: Contractor should conduct necessary test such as earth continuity, earth resistance test in presence of Engineer-in-Charge.
Supply and fixing of LED street light fitting 35 Watt 230 Volt AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, all as specified and directed.
S&F of sub main wiring with two single core 4.0 Sqmm PVC (FRLS) copper conductor, insulated multistranded unsheathed cable medium grade including PVC casing and capping of required size (not less than 25mm) conforming to IS 2079-1973 with accessories for sub main connection including 4.0 Sqmm FRLS insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified and directed. (Note: Three runs of 4.0 sqmm PVC FRLS copper conductor shall be measured as one unit length).
Supply and fixing of sheet metal enclosure, double door for MCB single pole & neutral DB's, 12 way with 200 Amps rated bus bar suitable for 240 Volt, AC, 50Hz, complete all as specified and directed.
Supply and fixing of sheet metal enclosure, double door for MCB single pole & neutral DB's, 8 way with 200 amps rated bus bar suitable for 240 Volt, AC, 50Hz, complete all as specified and directed.
Supply and fixing of 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole & neutral (SPN) and current carrying capacity of 32 Amps in the MCB DB complete with connection testing and commissioning, all as specified and directed.
Supply and fixing of 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole (SP) and current carrying capacity of 5 To 32 Amps in the MCB DB complete with connection testing and commissioning, all as specified and directed.
Note 1:- (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum / amendments and general condition of contracts before entry / quoting the rates. Note 2:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount.
MS BRAHMA CONSTRUCTION
DEEP CHANDRA JOSHI
ANTHONY PRADHAN
HEM RAJ GURUNG
G K SUTHAR
PRASAD PRADHAN AND SON
SUNIL PRADHAN
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .