Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance D 60 BRINDAVAN NAGAR CIVIL AERODROME POST COIMBATORE 641014 | COIMBATORE | COIMBATORE | TAMIL NADU | 641014 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance 201 PLOT NO 32 SHALAKA BLDG TPS II JUHU ROAD SANTACRUZ WEST MUMBAI SUBURBAN MAHARASHTRA 400054 | MUMBAI SUBURBAN | MAHARASHTRA | 400054 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
22 Mar 2021, 3:00 pmClosed
SM(Engg-E)
Operational Offices, RHQ/SR, AAI, Chennai Airport
CON. HOSTEL ACCOMMODATION IN SR RESIDENTIAL COLONY, CHENNAI AIRPORT. SH POWER SUPPLY WORKS
2021_AAI_73053_1
AAI/SR/SM(E-E)/COLONY/HOSTEL PS/2021
Open Tender
Electrical Works
Item Rate
90 days
Chennai Airport Residential Colony
Please refer Tender documents.
15 documents required · 15 mandatory
₹1,180
Exempted
25 Mar 2021
13 Mar 2021
23 Mar 2021
13 Mar 2021
22 Mar 2021
13 Mar 2021
13 Mar 2021 - 19 Mar 2021
Fabrication, SITC of Outdoor MV Switch Board Panel made of 2 mm thick CRCA Sheet Steel and outer shell made of 3 mm thick CRCA sheet steel, dust tight, vermin proof, totally enclosed, double door type, floor mounting, bottom entry type with rain guard and removable gland plates suitable for operation at 415 V, 3 Phase, 4 Wire, 50 Hz, A.C.System complete with all accessories, interconnection, connection, earthing, painting, including providing RCC pedestal and grouting the panel, etc., complete as required and comprising of the following:
A) Two Nos. of 250 A, 50 KA, 4P MCCBs with Thermal Magnetic Releases for Protection as INCOMERS with C.T. operated Digital VAF Meter, ON/OFF/TRIP Indication Lamps and Phase Indication Lamps, Interlocking Facility with Incomers and Buscouplers as required.
B) One No. 250 A, 50 KA, 4P MCCBs with Thermal Magnetic Releases for Protection as Bus Coupler with ON/OFF Indication Lamps as required.
C) One No. of 250 A, 50 KA, 4P MCCB with Thermal Magnetic Releases for Protection as Outgoing, C.T. operated Digital VAF Meter, ON/OFF/TRIP Indication Lamps and Phase Indication Lamps as required.
D) Twelve Nos. of 63 A, 25 KA, 4P MCCB with Thermal Magnetic Releases for Protection as Outgoing, ON/OFF/TRIP Indication Lamps and Phase Indication Lamps as required.
E) One Set of 300 Amps Al. Bus Bars with at Par Neutral BUS BARS as required.
F) All accessories such as fuses, auxillary contactors, auxillary switches, etc. complete as required.
ALL AS ABOVE 1 (A) To 1 (F)
Fabrication, SITC of Outdoor MV Switch Board Panel made of 2 mm thick CRCA Sheet Steel and outer shell made of 3 mm thick CRCA sheet steel, dust tight, vermin proof, totally enclosed, double door type, floor mounting, bottom entry type with rain guard and removable gland plates suitable for operation at 415 V, 3 Phase, 4 Wire, 50 Hz, A.C.System complete with all accessories, interconnection, connection, earthing, painting, including providing RCC pedestal and grouting the panel, etc., complete as required and comprising of the following:
Two Nos. of 250 A, 50 KA, 4P MCCBs with Thermal Magnetic Releases for Protection as INCOMERS with C.T. operated Digital VAF Meter, ON/OFF/TRIP Indication Lamps and Phase Indication Lamps, Interlocking Facility with Incomers and Buscouplers as required.
One No. 250 A, 50 KA, 4P MCCBs with Thermal Magnetic Releases for Protection as Bus Coupler with ON/OFF Indication Lamps as required.
One No. of 250 A, 50 KA, 4P MCCB with Thermal Magnetic Releases for Protection as Outgoing, C.T. operated Digital VAF Meter, ON/OFF/TRIP Indication Lamps and Phase Indication Lamps as required.
Three Nos. of 125 A, 25 KA, 4P MCCB with Thermal Magnetic Releases for Protection as Outgoing, ON/OFF/TRIP Indication Lamps and Phase Indication Lamps as required.
Four Nos. of 63 A, 10 KA, 4P MCB (C curve) with Thermal Magnetic Releases for Protection as Outgoing, ON/OFF/TRIP Indication Lamps and Phase Indication Lamps as required.
Two Nos. Time switch for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format
One Set of 300 Amps Al. Bus Bars with at Par Neutral BUS BARS as required.
All accessories such as fuses, auxillary contactors, auxillary switches, etc. complete as required.
ALL AS ABOVE 2 (A) To 2 (H)
Fabrication, SITC of Indoor MV Switch Board Panel made of 2 mm thick CRCA Sheet Steel, dust tight, vermin proof, totally enclosed, double door type, Wall/floor mounting, bottom entry type with removable gland plates suitable for operation at 415 V, 3 Phase, 4 Wire, 50 Hz, A.C.System complete with all accessories, interconnection, connection, earthing, painting, including fixing the panel, etc., complete as required and comprising of the following:
One No. of 125 A, 50 KA, 4P MCCBs with Thermal Magnetic Releases for Protection as INCOMERS with ON/OFF/TRIP Indication Lamps and Phase Indication Lamps.
Four Nos. of 63 A, 25 KA, 4P MCCB with Thermal Magnetic Releases for Protection as Outgoing, ON/OFF/TRIP Indication Lamps and Phase Indication Lamps as required.
One Set of 200 Amps Al. Bus Bars with at Par Neutral BUS BARS as required.
ALL AS ABOVE 3 (A) To 3 (C)
SITC of MV Switch Board [Wall mounted Panel] made out of 2mm Thick CRCA Sheet, dust tight and vermin proof, totally enclosed, cubicle type, suitable for operation at 415 V, 3 Phase, 4 Wire, 50 Hz, AC System with 63 Amps MCCB as incomer, 100 Amps Busbar and 8 Nos of out goings having 32 Amps FP MCB & 3 Phase Energy meter ( 10-60 Amps, class 1 accuracy), interconnection with 6 Sqmm wire/cable for outgoings (Busbar to MCB & MCB to energy Meter), 100 Amps bus bar strip for incomer, all connections, din bars for mounting all switch gears, proper dressing of cables, earthing, painting, grouting the Panel on wall, providing knock out glanding plates including providing proper separation between energy meters etc., complete as required.
SITC of MV Switch Board [Wall mounted Panel] made out of 2mm Thick CRCA Sheet, dust tight and vermin proof, totally enclosed, cubicle type, suitable for operation at 415 V, 3 Phase, 4 Wire, 50 Hz, AC System with 63 Amps MCCB as incomer, 100 Amps Busbar and 4 Nos of out goings having 32 Amps FP MCB & 3 Phase Energy meter ( 10-60 Amps, class 1 accuracy), interconnection with 6 Sqmm wire/cable for outgoings (Busbar to MCB & MCB to energy Meter), 100 Amps bus bar strip for incomer, all connections, din bars for mounting all switch gears, proper dressing of cables, earthing, painting, grouting the Panel on wall, providing knock out glanding plates including providing proper separation between energy meters etc., complete as required.
Supply of following size XLPE insulated PVC sheathed aluminium conductor armoured power cable of 1.1KV grade confirming to IS 7098 (PART-I) with upto date amendments as required.
4 X 16 SQ.MM
3.5 X 35 SQ.MM
3.5 X 120 SQ.MM
3.5 X 300 SQ.MM
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminiumconductor cable of 1.1 KV grade as required.
4 X 16 SQ.MM
3½ X 35 sq. mm (32mm)
3½ X 120 sq. mm (45mm)
3½ X 300 sq. mm (70mm)
Laying of one number PVC/XLPE insulated and PVC sheathed power cable of 1.1KV grade Upto 35 sq.mm in the existing RCC/Hume/STONEWARE/METAL/HDPE Pipe as required.
Laying of one number PVC/XLPE insulated and PVC sheathed power cable of 1.1KV grade Above 95 sq. mm and upto 185 sq. mm in the existing RCC/Hume/STONEWARE/METAL/HDPE Pipe as required.
Laying of one number PVC/XLPE insulated and PVC sheathed power cable of 1.1KV grade Above 185 sq.mm and upto 400 sq.mm in the existing RCC/Hume/STONEWARE/METAL/HDPE Pipe as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size in the existing masonry open duct Above 185 sq. mm and upto 400 sq. mm as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray Upto 35 sq. mm (clamped with 1mm thick saddle) as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray Above 185 sq. mm and upto 400 sq. mm (clamped with 1mm thick saddle) as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE powercable of 1.1 KV grade of following size on wall surface Upto 35 sq. mm (clamped with 1mm thick saddle) as required.
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders/ fixing on wall including bolts & nuts, painting etc as required.
300 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and laying of "B" Class G.I pipe of 100 mm dia, i/c excavation of bituminous/concrete road/pavement, excavation of Soil to maximum Depth of 1.20 Mtrs from ground refilling the Soil and with CC of ratio 1:3:6 on top for 0.15 Mtrs after laying Pipe and plastering, making good the same etc., as required.
Supplying and laying of 50 mm OD HDPE Pipe of PE 80 PN 6 ISI Marked along with all accessories like socket, bend etc., confirming to IS 4984 complete with fitting and cutting, jointing etc., direct in ground (.75 mtr below the ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., as required.
Supplying and laying of 125 mm OD HDPE Pipe of PE 80 PN 6 ISI Marked along with all accessories like socket, bend etc., confirming to IS 4984 complete with fitting and cutting, jointing etc., direct in ground (.75 mtr below the ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., as required.
Providing, laying and fixing of following dia RCC pipe NP2 class ( light duty ) in ground compkete with RCC collaars, jointing with cement mortar 1:2 ( 1 cement :2 fine sand including trenching (75 cm deep) and refilling etc as required.
Construction and supply of per-cast RCC Manhole Chamber of internal Dimension 1Mx1Mx1M ( External 1.2Mx1.2Mx1.2M) with RCC half split top cover of thickness 100mm with L angle reinforced at all sides of top and bottom of covers, lifting hook including finishing with Cement Cost as required.
Supply of 45W LED street light luminarie ( Efficacy not less than 110 Lumens/watt) with pressure die cast aluminium housing, toughened glass cover, IP 66, suitable for operating at 230 V+/- AC Supply as required.
Erection of existing metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 6.5 metre and upto 8.0 metre
Installation,Testing, Commissioning of street light fittings directly on street light pole, including connections with 3x1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable from MCB to fitting, earthing etc., complete as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixng 6 SWG GI wire on surface or in recess for loop earthing along with the existing surface/recessed conduit/submain wiring/cable as required.
Supply, installation, testing and commissioning of openwell type submersible pump of 210 LPM discharge (minimum) at 30 mtr head, C.I impeller, SS shaft etc with 3 HP/2.2KW motor suitable for 50mm dia delivery line for operation on 415 V, 3 phase power supply etc, min. 6 mtr suitable submersible cable including supply and fixing of 50mm dia NR Valve and butterfly valve and bringing the delivery line outside of the UG sump i/c all accessories and supports etc, complete as required (As per list of AAI approved makes)
Providing Civil Works as required as detailed below:
Structural steel work in single section, fixed with or without connection plate, i/c cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
Providing and laying in position cement concrete of specific grade excluding the cost of centering and shuttering. 1:4:8 (1 Cement: 4 coarse sand (zone-III): 8 graded stone aggregate 40 mm nominal size)
Centering and shuttering including struting, propping etc, and removal of all form for all heights
Providing and laying in position cement concrete of specific grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement. 1:2:4 (1 Cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Steel reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete
Brick work with bricks of class designation 60 in foundation and plinth in 1:6 (1 cement: 6 coarse sand)
Cement plaster 12mm thick of mixture 1:6
DEEPAKELECTRICALS
Manoprabha Electricals
C P MONCHESTER ELECTRICALS
RVD INFRA SOLUTION PVT.LTD.
vk sam engineering
DElite System Engineering (India) Pvt. Ltd.
CHENNAI ENGINEERING SERVICES
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .