Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹44 L
EMD Value
₹44,000
Closing Date
26 Mar 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC MEERUT
130 D PAARESHAN BHAWAN VICTORIA PARK MEERUT
WORK TENDER
2021_UPTCL_567765_1
T-141/20-21/ETC/MT
Open Tender
Electrical Works
Item Rate
90 days
MEERUT
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
SE ETC MEERUT
₹44,000
22 May 2021
10 Mar 2021
27 Mar 2021
10 Mar 2021
26 Mar 2021
10 Mar 2021
90 days
Amount
Work Portion
Opening / Cutting of R,Y & B phase of 220KV existing Main Bus / Jack Bus of Tarantulla/Zebra / Moose conductor between Bus section below gantry step by step during Bus Bar replacement work including dismantling of all type of associated clamps and fitting.
Dismantling of 220 KV Jumpers
Dismantling of supension fittings
Opening / Cutting of R,Y & B phase of 132KV existing Main Bus / Jack Bus of Tarantulla/Zebra / Moose conductor between Bus section below gantry step by step during Bus Bar replacement work including dismantling of all type of associated clamps and fitting.
Dismantling of 132 KV Jumpers
Dismantling of supension fittings
Opening / Cutting of R,Y & B phase of 33KV existing Main Bus / Jack Bus of Tarantulla/Zebra / Moose conductor between Bus section below gantry step by step during Bus Bar replacement work including dismantling of all type of associated clamps and fitting.
Dismantling of 33 KV Feeder/ PT/LA Jumpers.
Dismantling of 220/132/33 KV single Main Bus Bar, Bus section (R,Y & B) of single Zebra/ Moose/ Tarantulla conductor and lowering down of conductor from Sub-Station gantry to complete dismantling works including dismantling of all associated tension clamps fitting & disc insulator.
220 KV Main Bus Single Zebra/Moose conductor
132 KV Main Bus Single Zebra/Moose conductor
33 KV Main Bus Single Zebra/ Moose conductor
Complete cleaning of disc insulators for all phases by suitable liquid cleaner, testing of IR value by insulation tester, making series connection & ready for hoisting with all cost of men, T&P to complete the work.
Cleaning of disc insulator of 220 KV string
Cleaning of disc insulator of 132 KV string
Cleaning of disc insulator of 33 KV string
Stringing of various Single Phase Jack Bus / Bus Bar of 220 KV, 132 KV & 33 KV with different type conductor and different length of span as mentioned below. The work includes cutting & bending of conductor, fixing of single /double bolted type tension fitting Hoisting of disc insulator and shifting of material from store site to erection site and all other associated work to complete the work satisfactorily as per drawing and technical specification.
220 KV Main Bus Twin Moose conductor
132 KV Main Bus Twin Moose conductor
33 KV Main Bus Twin Moose conductor
Fixing of 220/132/33 KV quadruple Moose suspension fitting under bus section of main bus-I below gantries with suitable hardware such as hoisting of disc insulators etc. to complete the work in all respect satisfactorily.
Fixing of 220/132/33 KV Twin Moose suspension fitting under bus section of main bus-I below gantries with suitable hardware such as hoisting of disc insulators etc. to complete the work in all respect satisfactorily.
Jumpering, interconnection of equipment with specified conductor of various 220 KV, 132 KV equipments with main/Transfer/Jack Bus Bar of ACC Tarantulla / ACSR Moose/Zebra/Panther conductor. The work includes cutting of conductor, bending in proper shap, clamping with the help of clamps and all other associated work to complete the work.
Jumpering of 220 KV Main Bus Twin Moose conductor
Jumpering of 132 KV Main Bus Twin Moose conductor
Jumpering of 33 KV Main Bus , PT/LA Twin Moose conductor
Erection of 220/132 KV Section Isolator structure with base frame, isolator box, Polycone insulator complete with earthing and cable connection.
Providing and fixing of 220 KV Male arm assembly (Male arm contact 2000 amp) for 220 KV Isolator.
Providing and fixing of 220 KV Female arm assembly (Female arm contact 2000 amp) for 220 KV Isolator.
Providing & Fixing of Rotary head assembly 220 KV Isolator made of gun metal back side mounting up polyclone insulator and fitted with arm assembly top side mounting a plate of size 100x100x12 mm along with 4 No 12 mm dia hole in side mounting the copper contact & SS spring hot dip galvanized nut bolt & washer including dismantling of old rotary head assembly and fixing of new rotary 2000 Amp, proper checking alignment and adjustment as per technical specification
Providing and fixing of 132 KV Male arm assembly (Male arm contact 2000 amp) for 132 KV Isolator.
Providing and fixing of 132 KV Female arm assembly (Female arm contact 2000 amp) for 132 KV Isolator.
Providing & Fixing of Rotary head assembly 132 KV Isolator made of gun metal back side mounting up polyclone insulator and fitted with arm assembly top side mounting a plate of size 100x100x12 mm along with 4 No 12 mm dia hole in side mounting the copper contact & SS spring hot dip galvanized nut bolt & washer including dismantling of old rotary head assembly and fixing of new rotary 2000 Amp, proper checking alignment and adjustment as per technical specification.
Supply Portion
Bolted type single Tension fitting for Twin Moose Conductor suitable for 1 x16 No Disc insulator with buckle and hardware set as per techinical specification.
Bolted type single Tension fitting for Twin Moose Conductor suitable for 1 x16 No Disc insulator without turn buckle and hardware set as per techinical specification.
Bolted type single Suspension fitting for Quadruple Moose Conductor Suitable for 1x16 No Disc insulator with hardware set as per techinical specification.
Bolted type single Suspension fitting for Twin Moose Conductor Suitable for 1x16 No Disc insulator with hardware set as per techinical specification.
Bolted type single Tension fitting for Twin Moose Conductor suitable for 1 x10 No Disc insulator with turn buckle and hardware set as per techinical specification.
Bolted type single Tension fitting for Twin Moose Conductor suitable for 1 x10 No Disc insulator without turn buckle and hardware set as per techinical specification.
Bolted type single Suspension fitting for Quadruple Moose Conductor Suitable for 1x10 No Disc insulator with hardware set as per techinical specification.
Bolted type single Suspension fitting for Twin Moose Conductor Suitable for 1x10 No Disc insulator with hardware set as per techinical specification.
Bolted type single Tension fitting for Twin Moose Conductor suitable for 1 x4 No Disc insulator without turn buckle and hardware set as per techinical specification.
4 Bolted Type PG clamp suitable for Moose to Moose Conductor Complete with HDG nut bolt & washer as per technical specification.
4 Bolted Type PG clamp suitable for Moose to Panther Conductor Complete with HDG nut bolt & washer as per technical specification.
3 Bolted Type PG clamp suitable for Panther to Panther Conductor Complete with HDG nut bolt & washer as per technical specification.
Bimetallic 220 KV Bus/ Line Isolator clamp made of aluminum alloy LM-6 for Twin Moose conductor with HDG nuts & bolts and washer as per technical specification .
Bimetallic 220 KV Section Isolator clamp capacity 2000Amp made of aluminum alloy LM-6 for Twin Moose conductor with HDG nuts & bolts and washer as per technical specification .
Bimetallic 220 KV CVT clamp made of aluminum alloy LM-6 for Twin Moose conductor with HDG nut & bolts and washer as per Technical specification.
Bimetallic 132KV Isolator clamp for Twin Moose conductor with nut, bolts and washer as per technical specification.
Bimetallic 132KV Section Isolator clamp capacity 2000 Amp for Twin Moose conductor with nut, bolts and washer as per technical specification.
Bimetallic132 KV CVTclamp for Twin Moose conductor with nut, bolts and washer as per technical specification.
Bimetallic 33 KV Isolator clamp for Twin Panther conductor with nut, bolts and washer as per technical specification.
Bimetallic 33 KV Isolator clamp for Twin Moose conductor with nut, bolts and washer as per technical specification.
Bimetallic 33 KV Section Isolator clamp for Twin Moose conductor with nut, bolts and washer as per technical specification.
Bimetallic 33 KV PT clamp for Twin Moose conductor with nut, bolts and washer as per technical specification.
Bimetallic 33 KV LA clamp for Twin Moose conductor with nut, bolts and washer as per technical specification.
Spacers for 250 mm spacing suitable for Moose conductor 02 bolted made of aluminum alloy LM-6 complete with hot dip galvanized nut bolt & washer as per technical .specification.
Spacers for 100 mm spacing suitable for Moose conductor 02 bolted made of aluminum alloy LM-6 complete with hot dip galvanized nut bolt & washer as per technical .specification.
Spacers for 60 mm spacing suitable for Panther conductor 01 bolted made of aluminum alloy LM-6 complete with hot dip galvanized nut bolt & washer as per technical specification.
Gupta Elect and Engg Works
Meena Elect & Engg. Works
Perfect Power Transformer Associates
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .