Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹17.5 L+₹1.4 L (8.43%)Rejected-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹22.4 L+₹6.3 L (38.9%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹23.0 L+₹6.8 L (42.2%)Rejected-AOC 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹26.5 L+₹10.4 L (64.3%)Rejected-AOC A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L5 | Rejected-AOC Rejected |
Tender Value
₹32.8 L
EMD Value
₹65,600
Closing Date
21 May 2022, 6:00 pmClosed
GE (P) AF Gurgaon
GE (P) AF Gurgaon Near Atul Kataria Chowk Gurgaon
CA NO. GE(P)AF/GUR-10/2022-23 REPAIR/MAINT OF AIR CONDITIONING, REFRIGERATOR, WATER COOLER AND OTHER COOLING APPLIANCES AT AF STN PALAM UNDER GE (P) AF GURGAON
2022_MES_519481_1
GE(P) AF/Gur-10/2022-23
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (P) AF Gurgaon
All as per NIT
10 documents required · 10 mandatory
₹500
GE (P) AF Gurgaon
₹65,600
20 Jun 2022
22 Apr 2022
23 May 2022
22 Apr 2022
21 May 2022
6 May 2022
Amount
S&F in replacement Blower/ condensor fan motor of three speed, testing, commissioning complete suitable for window type 1.5 to 2 Ton AC suitable to operate 230V AC all as specified and directed.
S&F in replcement of blower motor suitable for indoor unit rating and capacity as per site requirement for upto 2.0 ton capacity Split type AC complete all as specified and directed.
All same as per ser item No 2 above here in before but suitable for condensor fan of out door unit of split AC up to 2.0 TR capacity complete all as specified and directed.
S&F in replacement Blower fan made out of platic suitable for window/split type AC upto 2.0 ton capacity complete all as specified and directed.
S&F in replacement Condenser fan blade made out of aluminium/plastic as per matching to existing suitable for window split type AC upto 2.0 ton capacity complete all as specified and directed.
S&F in replacement Front grill suitalbe for window type AC upto 2 ton capacity complete all as specified and directed.
S&F in replacement of condensing coil suitable for window type room AC of capacity 1.5/2 ton.as per sample complete all as specified and directed.
S&F in replacement cooling coil suitable for window type room AC of capacity 1.5/2 ton.as per sample complete all as directed.
S&F in replacement Condensing coil suitable for split type AC of capacity 2 ton complete all as specified and directed.
S & F in replacement cooling coil suitable for split type AC of up to capacity 2 ton complete all as specified and directed.
S&F Indoor unit suitable for 2 TR split type AC suitable as per existing. Make:- LG/VOLTAS/DAIKEN. Cat No - (Make Voltas SAC_245V_ADZ(R32) white) complete all as specified and directed.
S&F in replacement MCB single pole, 32 Amps, 10 KA 240 Volts, 50 HZ type. C series complete all as specified and directed.
M&L in replacement PCB for window/Split type AC up to 2 Ton capacity complete all as specified and directed.
Suuply & Fix in replacement of company sealed compressor any type of existing make for split/ window type AC capacity 1.5 Ton with all fixing accessories complete all as specified and as directed by Engineer-in-charge.
All same as per ser item No. 14 here-in-before but of split/ window type AC capacity 2.0 Ton complete all as specified and directed.
S&F in replacement Starting Capacitor of 80 to 120 mfd complete all as specified and directed. Make Tibcon/ Epscos
S&F in replacement Running Capacitor of 06-45 Mfd suitable for window / split type AC complete all as specified and directed. Make Tibcon/ Epscos
S&F in replacement Starting Relay suitable for AC of any capacity complete all as specified and directed. Make- Hitech/Floron/Nafron/Rafron/ Ranutrol
S&F in replacement Thermostat switch suitaible for AC 1.50 to 2.00 ton capacity complete all as specified and directed. Make : Ranutrol or make as approved .
S&F in replacement Wiring kit suitable for 1.5 to 2.0 ton capacity AC complete complete all as specified and directed.
S&F in replacement Air filter of existing make : synthetic, PVC suitable for 1.5 to 2.0 ton capacity AC window/Split type complete all as specified and directed.
S&F in replacement Refrigerant gas filter and capilary assembly complete suitable for AC upto 2 ton capacity complete all as specified and directed.
S&F in replacement gas charging pin valve complete all as specified and directed.
Supply only refrigerant R-22 suitable for gas charging of Split AC/ Window AC.Complete all as specified and directed
Supply only refrigerant R-32 suitable for gas charging of Split AC/ Window AC.Complete all as specified and directed
M&L for replacement of split valve ¼” for split AC 1.5 ton capacity complete all as specified and directed.
All same as per item no 27 above here in before but 1/2" complete all as specified and directed.
S&F in replacement compressor shut off valve 3/8" for split AC 1.5 ton capacity complete all as specified and directed.
S&F in replacement compressor shut off valve 3/8" for split AC 2 ton capacity complete all as specified and directed.
S & F in replacement of Copper tubing of size 1/4" suitble for any type of split type AC complete all as specified and directed.
All same as per Ser item No. 31 but size 1/2" complete all as specified and directed.
All same as per Ser item No. 31 but size 3/8" complete all as specified and directed.
All same as per Ser item No. 31 but size 5/8" complete all as specified and directed.
S&F in replacement flexible condencer water pipe suitable for any type of AC complete all as specified and directed.
S&F in replacement PVC conduit 50mm dia including all clamps, tees & accessories and connecting the condensate pipe of Acs to this conduit for proper drainout of condensate water from Acs of Bldgs upto 5 (five) storey. MAKE- AKG/National
S&F in replacement of synthetic rubber tube for insulation for refrigerant copper piping of size 1/4" internal dia split type AC complete all as specified and directed suitable for the under mentioned sizes. MAKE- KAIFLEX or equivalent as approved.
All same as per ser item No. 37 but size 1/2" complete all as specified and directed.
All same as per ser item No. 37 but size 3/8" complete all as specified and directed.
All same as per ser item No. 37 but size 5/8" complete all as specified and directed.
S&F in replacement of window AC kit complete chasis including cooling coil, condensing coil, fan motor, blower, condensing fan and complete body without compressor suitable for window AC of capacity upto 2.0 ton complete all as specified and as diretced by Engineer-in-charge
S&F in replacement of remote for window / split type AC as per matching existing complete all as specified and directed.
S&F in replacement of condensate water collecting tray for window AC installed in bldg upto 5 storey complete all as specified and directed.
S&F in replacement metal plug top 2 pole and earth, 20 Amps, 250 volts suitalbe for sheet metal enslousers complete all as specified and directed. MAKE - L&T
S&F in repalcement metal clad socket 2 pole and earth, 20 Amps 250 volts suitalbe for sheet metal enclusers complete all as specified and directed. MAKE L&T
S&F Outdoor unit suitable for 2 TR split type AC suitable as per existing complete all as specified and directed.. Make:- LG/VOLTAS/DAIKEN. (Make Voltas SAC_245V_ADZ(R32) white)
S&F in replacement sheet metal enclosure single pole and neutral with 2 pin and earth socket complete with one single pole MCB 32 A, 10 KA 'C' series complete all as specified and directed.
M&L in replaqcement sub main wiring with two run of single core strated copper conductor cable of size 2.5 Sqmm and 1.5 Sqmm copper conductor cable as earth continuity conductor drawn in existing conduit or PVC casing capping complete all as directed.
M&L in replaqcement sub main wiring with two run of single core strated copper conductor cable of size 4 Sqmm and 2.5 Sqmm copper conductor cable as earth continuity conductor drawn in existing conduit or PVC casing capping complete all as directed.
S&F in replacement AC stand suitable for out door AC unit up to cap of 2 ton capacity complete all as specified and directed..
M&L for servicing of water cooler of any capacity including cleaning of water cooler from inside and outside with potassium permanaganates, servicing of colling coil, fan, motor, condensor, fan blades and its connected water and refrigerant fittings complete all as specified and directed.
Supply and charging the gas in the water cooler of any make and capacity including testing and detecting leakage if any with nitrogen gas and vaccum the sytem after rectification of all leakages complete all as specifie and directed.
S&F in replacement thermostat switch suitalbe for water cooler of any make & size complete all as specified and directed. Make : Renutrol or equivalent as approved.
S&F in replacement starting relay/over load relay suitalbe for water cooler of any make & size complete all as specified and directed.
S&F in replacement defective push cock 15 mm bore chromium plated heavy duty suitable for water cooler of any make and capacity complete all as specified and directed.
M&L for preparation of old painted surfaces of water cooler by removing old deteriorated paid, making surfaces smooth and applying two coats of synthetic enamel paint over a coat of red oxide primer by spray painting complete all as specified and directed..
S&F in replacement fan motor ISI marked suitalbe for water cooler capacity upto 150 ltrs of any make complete all as specified and directed. MAKE GEC
S&F in replacement of condenser fan of any make suitable for water cooler upto 150 ltrs capacity complete all as specified and directed.
S&F in replacement 15 mm dia PVC connection of length upto 600mm with PTMT nuts on both ends complete all as specified and directed.
S&F in replacement condenser coil suitable for water cooler upto 150 ltrs capacity complete all as specifed and directed.
S&F in replacement steel/aluminium waste water tray suitable for water cooler upto 150 ltrs capacity complete all as specifed and directed.
S&F in replacement company sealed compressor unit of water coolers of capacity 40 to 180 ltrs complete all as specified and directed. MAKE- KIRLOSKAR
M&L for servicing of desert cooler of any size including cleaning of desert cooler from inside & outside, greasing of fan kit, motor, water pump and connected accessories complete all as specified and directed. Note : Unserviceable parts requires replacement shall be measured and paid separately as supply only under respective items of this schedule.
M&L for painting of desert cooler capacity upto 4000 Cfm with two coats of approved synthetic enamel paint inside & outside including fan/fan blade/brackets after scrapping the rust,peal of paint and preparation of surface complete all as specified and directed by Engr-in-Charge. Note : The rates are inclusive of taking down cooler from any height, removal to workshop for painiting and refixing in position after painting.
S&F in replacement of wood wool pad (set of three) heavy duty for desert cooler complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of desert cooler sub mersible water pump complete with electric motor single phase 230 volts 50Hz including lead, connecting & testing complete all as specified and directed. Make:- Khaitan or equivalent as approved.
S&F in replacement desert cooler fan motor,copper wound suitable for upto 450mm sweep SP 230 volts 50HZ including legs, rubber bush nuts/bolts for fixing of fan motor complete with connection & testing. Make : KHAITAN or equivalent as approved.
S&F in repalcement of commercial ply wood BWP 4mm thick ISI marked for desert cooler of any size to close the opening between desert cooler grill and window complete all as directed by Engr-in-Charge.
S&F in replacement plug top 3 pin 5 Amps complete all as specified and directed. Make : Anchor or equivalent as approved from list of make.
S&F in replacement plug top 3 pin 15 Amps complete all as specified and directed. Make : Anchor or equivalent as approved from list of make.
S&F in replacement motor capacitor 2.5/3.15/4 Mfd complete all as specified and directed. Make Tibcon or equivalent as approved.
S&F in replacement front grill made of MS complete with air guide vanes suitable for desert cooler of capacity 4000 Cfm complete all as specified and directed.
S&F in replacement of body without side panels made out of galvanised iron sheets of of 18 gauge for bottom tank & 20 gauge for top cover of desert cooler body duly painted with red-oxide & 2 coat of synthetic enameled paint complete with fixing of all spare all as directed by Engineer-in-charge
S&F in replacement of side panels of desert cooler body of 22 gauge of existing size & shape duly painted with red-oxide & 2 coat of synthetic enameled paint complete with fixing of all spare all as directed by Engineer-in-charge.
S&F in replacement of float valve assembly with PTMT ferrule 15 mm dia and PVC ball valve suitable for water cooler up to 150 ltrs capacity and desert cooler upto 4000 Cfm complete all as directed by Engr-in-Charge.
S&F in replacement of PVC rubber pipe 15mm bore heavy duty including pvc elbow threaded suitable for insertion in flexible PVC pipe complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of PVC water distributor four way complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of Cooling coil complete with cooling chamber of refrigerator of capacity 320 Ltrs complete all as specified and directed.
S&F in replacement of compressor for refrigerator of capacity 340 Ltrs double door (Make-Haier) as per matching to existing complete all as specified and directed.
M&L for repair to refrigerator any capacity upto 310 Ltrs including replacement of all spares like any relay, wiring, thermostate, capacitor, leakage testing & stopping the leakage and charging the refrigerant gas complete all as specified as directed.
M&L for repair to deep freezer any capacity upto 425 Ltrs including replacement of all spares like any relay, wiring, thermostate, capacitor, leakage testing & stopping the leakage and charging the refrigerant gas complete all as specified as directed.
Supply & fix compressor for bottled water dispenser including brazing work creating vacuum for 24 hrs for pressure testing and charging of refrigerant R134a, having option of dispensing hot and cold water with cooling capacity 3 ltrs/hr and tank capacity of 3.4 ltrs, heating capacity 6 ltrs/hr and tank capacity1.6 ltrs, working in R - 134a refrigerant, complete all as specified and as directed by Engr-in-Charge. Make-Voltas/LG/Emerson Copeland
S&F in replacement of Voltage Stabilizer for automatic operation single phase 230 volts 50 C/s AC 160 volt to 250 volts + 2.5 % of capacity 5 KVA electronic digital type wall mounted type, complete all as specified and directed by Engr-in-charge. Make: Cat No 1SB44B of Volina/Cat No PS 170 Power plus of Crompton/Cat No VG-500 of V-Guard Note: Unserviceable units will be deposited to MES store
S&F in replacement of mini magic pure-T dispenser, tank material of stainless steel, its function for Hot, Normal & cool complete all as specified and as directed by Engineer-in-charge.Voltas/LG/Godrej
Annual maintenance for Dehumidifier (Make - BRY Air) which include servicing overhaulling and regular inspection for any defect (A) Servicing (i) Checking the motors and starter. (ii) Checking the operation and proper functioning of controls (iii) Checking up bed speed and bed drive (iv) Inspecting and cleaning air filter (v) Lubricating the bearings of motors and fans etc (vi) Inspection of reactivation site and re genaration heat source (vii) Inspaection of all seals (viii) Insapection of reduction gear unit, sprocket wheel and adjustment of sprocket chain (ix) Inspection of flexible connection of process and reactivation fans from unit (x) Checking tha air pressure balancing and air flow of system (xi) Checking the plant profrmance (xii) Checking of all other parts
(B) Overhaulling (i) Checking andinspection of bed (s), bed screen (ii) Checking and inspection of bed seal, center divider seal & radius and end seal for each unit (iii) Greasing/Lubricating of all motors, drives, bearings etc (iv) Checking and inspecting impellers of 'Reactivation' fans as well as 'process' fan (v) Overhauling of the bed drive gear reduction unit (vi) Checking of associate dust work for air vapour tightness (vii) Detailed check of the air pressure balancing of the system /unit (viii) Detailed check of the performance of the system /unit Note :- This AMC includes only servicing, overhauling and minor repair and any major parts to be replaced should be measured and paid seprately as 'Supply only' under respective item of Schedule.
Supply only following items for dehumidifier installed at 16 BRD complete all as specified and directed. (Make - BRY Air dehumidifier unit FFB-1500
Bed drive motor (Cat No - E61821)
Bed drive motor pulley
Bed drive timing belt
Drive cog segment
Idler assembly
Idler spring
Process fan wheel
React fan wheel
Process fan motor
React fan motor
Seal group (Cat No - E11009E)
Heater
React temp safety thermostate
Cool down thermostate
React pressure swiitch (Cat No - E31360)
Process air filter
React air filter
RTV sealant
Bed failure limit switch
Controler
Humidistat sencor
Humdistat
Note for ser item No. 1 to 87.22 :-
1. The contractor shall provide and deploy sufficient technician with helpers (as approved by GE / Engineer-in-charge) for maintenance of summer appliances at 13BRD, 16 BRD, 27 ED & 31 MCU and contractor's site supevisor/site engineer shall report at 0900 hrs daily excluding Sunday & holiday to collect the complaints & complete the same complaint detailed by JE E/M /Engineer-in-charge with in 24 hrs.
2. The complaints shall be rectified with in 24 hrs. If the complaints is/are not complited on same day (except repair/ replacement of major items like repair/ replacement of compressor, cooling coil, condensing coil, fan motor ducting work of AC plant & insulation work. these work can be completed in time period (max 36 Hrs) as decided by Engineer-in-charge after which recovery shall be made as under), the recovery will be done as follows
(a) After 24 Hrs Rs - 1000.00 Per complaint per day.
The decesion of GE on recovery against penalty shall be final and binding and No representation whatsoever shall be entertained.
3. The technicians for repair of summer appliances can be called during non-working days/hrs (i.e. Sunday, Holidays & after working hrs) for any vital complaint at AF Station PALAM.
Note:- The amount of Rs 1,48,268/- against Schedule of Credit on Page Nos 120 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance
M/S Anand Enterprises
numac powertech
Saini Enterprises
M/s Adhikari construction co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .