Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC CIVIL LINE MATATILA ROAD TALBEHAT DISTT LALITPUR U P | TALBEHAT | LALITPUR | U P | L1 | Accepted-AOC L1 | |
| 2 | L2₹10.7 L+₹90,305 (9.21%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
Refer Docs
Closing Date
9 Nov 2021, 6:00 pmClosed
AGE I TALBEHAT
LAKE VIEW CAMP MIL STN TALBEHAT 284125
REPAIR/MAINT OF MCB/DB/SUBMAIN/METER PANEL BOX AND OTHER MISC ELECRICAL WORK AT TALBEHAT MIL STN
2021_MES_480817_1
AGE(I)/TBT/TOK-55/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
MILITARY STATION TALBEHAT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE I TALBEHAT
Exempted
18 Nov 2021
9 Oct 2021
12 Nov 2021
16 Oct 2021
9 Nov 2021
23 Oct 2021
Amount
Taking down Distribution Boards along with MCB's incl removing the same from site and making good to the disturbed surface complete.
Taking down existing sub main wiring of any type and description including removal of teak wood batten/pipe etc. complete.
Taking down meter box with existing meters carefully from site and making good to the disturbed surface complete all as specified and directed. Note: Existing meter will keep in safe custody for refixing after taking down.
M&L for sub main wiring with two single core PVC insulated of size 10 sqmm FRLS unsheathed copper conductor 1100 volt grade multistranded and incl drawn through and connected with proper lugs, including non metallic rigid PVC conduit and conduit accessories of 25 mm external dia and conduit FRLS accessories of ISI marks medium grade including 10.0 sqmm FRLS copper wire for earth continuity wire and connected of common earth dolly. Wire: Make -Mescab/Polycab/KEI PVC conduit: Make -Polycab/Precision/Plaza Note:- (i)One run of conduit two run of 10 sq mm copper conductor & one run of 10 sq mm copper conductor is measured as one unit. (ii) On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit and its accessories. (iii) On MCCB/MCB/Meter boxes wiring done on surface with flexible conduit and its accessories. (iv) PCC and white wash for making good surfaces, the rate included in sch of items.
M&L for sub main wiring with two single core PVC insulated of size 6.0 sqmm FRLS unsheathed copper conductor 1100 volt grade multistranded and incl drawn through and connected with proper lugs, including non metallic rigid PVC conduit and conduit accessories of 25 mm external dia and conduit FRLS accessories of ISI marks medium grade including 6.0 sqmm FRLS copper wire for earth continuity wire and connected of common earth dolly. Wire: Make -Mescab/Polycab/KEI PVC conduit: Make -Polycab/Precision/Plaza Note:- (i)One run of conduit two run of 6.0 sq mm copper conductor & one run of 6.0 sq mm copper conductor is measured as one unit. (ii) On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit and its accessories. (iii) On MCCB/MCB/Meter boxes wiring done on surface with flexible conduit and its accessories. (iv) PCC and white wash for making good surfaces, the rate included in sch of items.
M&L for sub main wiring with two single core PVC insulated of size 4.0 sqmm FRLS unsheathed copper conductor 1100 volt grade multistranded and incl drawn through and connected with proper lugs, including non metallic rigid PVC conduit and conduit accessories of 20 mm external dia and conduit FRLS accessories of ISI marks medium grade including 4.0 sqmm FRLS copper wire for earth continuity wire and connected of common earth dolly. Wire: Make -Mescab/Polycab/KEI PVC conduit: Make -Polycab/Precision/Plaza Note:- (i)One run of conduit two run of 4 sq mm copper conductor & one run of 4.0 sq mm copper conductor is measured as one unit. (ii) On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit and its accessories. (iii) On MCCB/MCB/Meter boxes wiring done on surface with flexible conduit and its accessories. (iv) PCC and white wash for making good surfaces, the rate included in sch of items.
S&F in replacement single pole and neutral enclosure with a two pin and earth plug socket complete with one single pole MCB of 20 Amp 240 volt. Make:- Legrand/Hager/Schneider/IndoAsian/Siemens.
S&F sheet metal enclosure double door MCB DB single pole and neutral 8 way 240 volts (Metallic) type. Make:- Legrand/Hager/Schneider/IndoAsian/Siemens.
S&F sheet metal enclosure single door MCB DB single pole and neutral 2 way with , 240 volts (Metallic) type fixing on main meter box for sub main of each accn. Make:- Legrand/Hager/Schneider/IndoAsian/Siemens.
S&F vertical sheet metal enclosure double door for MCCB D B Triple pole and neutral 4 way, (12+4) with 200 Amps rated bus bar 415 volts earth dolly IP-43, IK09, double door (Metallic) type. Make:- Legrand/Hager/Schneider/IndoAsian/Siemens. Note:-MCB are measured and paid separately under respective items.
S&F MCB SP 5 to 32 Amps 240 volts 'C' series, 10 KA, 50 Hz, confirming to IS/IEC-60898-1. Make:- As approved Make of DB
S&F MCB SP 40 to 63 Amps 240 volts 'C' series, 10 KA, 50 Hz, confirming to IS/IEC-60898-1. Make:- As approved Make of DB
S&F MCB SPN 40 to 63 Amps 240 volts 'C' series, 10 KA, 50 Hz, confirming to IS/IEC-60898-1. Make:- As approved Make of DB
S&F MCCB TPN 63 Amp, 440 volt 'C' series, 16 KA, 50 Hz, confirming to IS/IEC-60898-1. Make:- As approved Make of DB
Taking down of existing meters with wiring carefully, repair of meter box and wooden door, painting of steel plate and wooden door complete, refixing of 04 Nos meters with nut & bolts by drilling on existing steel plate with locking arrangement complete all as specified and as directed by Engineer-in-Charge. Note:- (i) Sub main of cable are measured and paid separately under respective items. (ii) PCC and white wash for making to the good surfaces, the rate are included in same sch of items.
S&F meter metal box (for existing 04 Nos meter & 04 Nos 2 way DBs) size 700x480x210 rustproof and cable entry from bottom and top side of each meter box and 04 Nos glasses in front on box, including refixing of existing meter with nut & bolts complete all as specified and directed. Make: Sintex Note:- (i) Sub main of cable are measured and paid separately under respective items.
Cutting of wall, floor and roads for fixing of pipe, boxes complete all as specified and directed.
M&L Rendering 10mm thick Cement plaster 1:4 on fair faces of brick work or concrete surfaces complete all as specified and as directed.
M&L for cement concrete in foundations, filling and mass concrete type C-2 (1:3:6) 20mm grade aggregate complete all as specified and as directed.
Supply and laying or fixing in replacement GI tubes light grade 40 mm dia, on place of rusted GI pipe in support of cables, on roof/pole/wall/laid in floor/in trenches. Make:- JINDAL, TATA, PRAKASH.
Note :- Debris obtained from all items should be removed in low lying areas as directed by Engr-in-charge out of MOD Land. (Rates quoted for items are deemed to be included for this, where removal of debris in the items is not considered.)
M/s Pooja Electricals
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .