Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 CrAdmitted-Finance | ₹13.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹14.3 CrAdmitted-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹14.3 Cr | L2 | Admitted-Finance |
| 3 | L3₹14.4 CrAdmitted-Finance | ₹14.4 Cr | L3 | Admitted-Finance |
| 4 | L4₹14.5 CrAdmitted-Finance | ₹14.5 Cr | L4 | Admitted-Finance |
| 5 | L5₹14.6 CrAdmitted-Finance | ₹14.6 Cr | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | sumaja electroinfra pvt ltd L5 | K. Ramachandra Rao Transmission and Projects Pvt. Ltd. L7 | Blue Star Ltd. L2 | suncity Enterprises L6 | Telmos Electronics L1 | SALASAR TECHNO ENGINEERING LIMITED L4 | Hartek Power Private L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | 72.5kV, 1250A, single 3 – ø or three 1 –ø, SF6 gas insulated, metal enclosed bus bars arrangement, consisting of 1250A single 3 – ø or three 1 –ø SF6 gas insulated switchgears, each Bus Bar comprising of :-
i ) Bus bar enclosures running through the length of the switchgear to interconnect each of the circuit breaker bay modules in double main bus system
ii)Three, 2-core, single phase or single 3 – ø voltage transformers/ PTs.
iii) 1250A, One 3 – ø or three 1 – ø, single pole, group operated isolator/disconnector and one, 3 – ø or three 1 – ø, single pole, group operated earthing switch with manual and motor driven operating mechanisms.
iv) 1250A, One high speed fault make 3 – ø or three 1 – ø, single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms.
v) Each GIS compartment with gas monitoring device, pressure switch etc. as required.
vi) Terminal boxes/ Local Control Cubicle.
vii) Interconnecting wiring/ piping.
viii) Grounding, support structures and platforms. | 2 | Set | 200 ₹236 | 1,05,84,000 ₹1.3 Cr | 62,29,052 ₹75.5 L | 1,21,71,384.76 ₹1.6 Cr | 58,50,000 ₹72.6 L | 67,95,546 ₹83.4 L | 56,00,000 ₹67.6 L |
| 2.00 | 72.5kV, 800A, single 3 – ø or three 1 –ø, Bus coupler bay module, consisting of 800A single 3 – ø or three 1 –ø SF6 gas insulated switchgears, comprising of:
i) 800A, One 3 – ø or three 1 –ø, SF6 gas insulated circuit breaker, complete with operating mechanism.
ii) Three,3-core,single phase current transformers(600-300-150/1-1-1A)
iii) Two sets of isolator/disconnector switches each of 800A, One 3 – ø or three 1 – ø, single pole, group operated isolator/disconnector switches each with 3 –ø or three 1 – ø, single pole, group operated earthing switch and complete with manual and motor driven operating mechanisms.
iv) Each GIS compartment with gas monitoring device, pressure switch etc. as required.
v) Terminal boxes/ Local Control Cubicle.
vi) Interconnecting wiring/ piping.
vii) Grounding, support structures and platforms. | 1 | Set | 1,20,00,000 ₹1.4 Cr | 52,92,000 ₹63.1 L | 56,06,147 ₹67.2 L | 51,27,904.37 ₹68.8 L | 47,00,000 ₹57.8 L | 55,72,950 ₹68.4 L | 50,50,000 ₹60.4 L |
| 3.00 | 72.5kV, 800A, single 3 –ø or three 1 –ø, Transmission line feeder circuit breaker bay modules, consisting of 800A single 3 –ø or three 1 –ø SF6 gas insulated switchgears, each comprising of:-
i) 800A, One 3 – ø or three 1 –ø, SF6 gas insulated circuit breaker, complete with operating mechanism for outgoing feeder.
ii) Three, 66kV LAs and Voltage detectors /sensors
iii) Three, 3-core, single phase current transformers(600-300-150/1-1-1A)
iv) 800A, One 3 – ø or three 1 – ø, single pole, group operated isolator/disconnector without earthing switch, complete with manual and motor driven operating mechanisms.
v) 800A, One 3 – ø or three 1 –ø, single pole, group operated isolator/disconnector with one, 3 – ø or three 1 – ø, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.
vi) 800A, One 3 – ø or three 1 – ø, single pole, group operated isolator/disconnector with one normal and one high speed fault make 3 – ø or three 1 – ø, single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms.
vii) Each GIS compartment with gas monitoring device, pressure switch etc. as required.
viii) Voltage detectors /sensors
ix) Terminal boxes/ Local Control Cubicle.
x) Interconnecting wiring/piping
xi) Grounding, support structures and platforms. | 4 | SET | 3,80,00,000 ₹4.5 Cr | 3,16,80,000 ₹3.8 Cr | 2,59,12,856 ₹3.1 Cr | 2,77,97,705.92 ₹3.6 Cr | 2,48,00,000 ₹3.1 Cr | 2,96,08,240 ₹3.6 Cr | 2,64,00,000 ₹3.1 Cr |
| 4.00 | 72.5kV, 400A, single 3 –ø or three 1 –ø, Transformer feeder circuit breaker bay modules, consisting of 400A single 3 – ø or three 1 –ø SF6 gas insulated switchgears, for 66/11kV transformer, each comprising of: -
i) One 3 – ø or three 1 – ø, SF6 gas insulated circuit breaker, complete with operating mechanism for incomer bay from 66/11kV transformer.
ii) Three, 3-core, single phase current transformers (300-150/1-1-1A).
iii) 400A, One 3 – ø or three 1 – ø, single pole, group operated isolator/disconnector without earthing switch, complete with manual and motor driven operating mechanisms.
iv) 400A, One 3 – ø or three 1 – ø, single pole, group operated isolator/disconnector with one, 3 – ø or three 1 – ø, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.
v) 400A, One 3 – ø or three 1 – ø, single pole, group operated isolator/disconnector with two earthing switches each comprising of one 3 – ø or three 1 – ø, single pole, group operated earthing switches complete with manual and motor driven operating mechanisms.
vi) Each GIS compartment with gas monitoring device, pressure switch etc. as required.
vii) Local Control Cubicle.
viii) Interconnecting wiring/piping.
ix) Grounding, support structures and platforms. | 2 | Set | 2,14,00,000 ₹2.5 Cr | 1,26,00,000 ₹1.5 Cr | 1,27,07,266 ₹1.5 Cr | 1,18,63,866.88 ₹1.6 Cr | 1,10,00,000 ₹1.4 Cr | 1,32,26,626 ₹1.6 Cr | 1,21,00,000 ₹1.4 Cr |
| 5.10 | a) 66kV XLPE copper Cable 1CX (400mm2) along with one no. spare cable coated with fire retardant Paint for connecting 66kV side of 66/11kV transformer with GIS. | 300 | Mtr. | 21,00,000 ₹24.9 L | 13,50,000 ₹17.2 L | 14,19,300 ₹18.0 L | 10,41,903 ₹13.8 L | 33,60,000 ₹40.9 L | 15,57,600 ₹19.1 L | 14,40,000 ₹22.3 L |
| 5.20 | b) Termination kit for both ends for 66kV XLPE copper Cable 1CX (400mm2). | 16 | No. | 40,00,000 ₹48.1 L | 10,08,000 ₹23.8 L | 9,92,576 ₹13.8 L | 9,71,503.68 ₹12.6 L | 18,40,000 ₹25.5 L | 21,42,640 ₹29.1 L | 10,88,000 ₹17.6 L |
| 6.00 | 25/31.5MVA, 66/11 kV Power T/F along with10% extra T/F oil (will be provided by HVPNL) | 2 | No. | - | - | - | - | - | - | - |
| 7.00 | 220V 100 AH Battery | 1 | Set | 2,50,000 ₹3.0 L | 2,07,000 ₹2.5 L | 3,00,818 ₹3.7 L | 2,75,695.85 ₹3.5 L | 2,00,000 ₹3.0 L | 4,00,494 ₹4.9 L | 3,50,000 ₹4.2 L |
| 8.00 | 66 kV Surge Arrestor | 6 | No. | 3,00,000 ₹3.6 L | 1,62,000 ₹2.0 L | 1,47,222 ₹1.8 L | 2,04,156.6 ₹2.6 L | 1,50,000 ₹1.9 L | 2,02,752 ₹2.5 L | 1,68,000 ₹2.3 L |
| 9.00 | 11 kV Surge Arrestor | 6 | No. | 36,000 ₹46,020 | 16,200 ₹20,390.40 | 51,960 ₹65,617.44 | 24,639.6 ₹33,239.47 | 45,000 ₹56,640 | 22,530 ₹27,286.32 | 45,000 ₹77,880 |
Tender Value
₹14.5 Cr
EMD Value
₹29 L
Closing Date
31 Aug 2020, 5:00 pmClosed
SE CONTRACTS
Office of Chief Engineer PD and C Shakti Bhawan, Sector-6, Panchkula
66kV GIS Substation Phase-1, Udyog Vihar, Gurgaon with LILO of one circuit of 66kV Dundahera Ph-IV Sec-23A D/C through underground cable and Creation of D/C underground XLPE cable from 220kV S/Stn Sec-20 to HSIIDC phase-I Udyog Vihar (GIS)
2020_HBC_135773_1
EPC-D 06 PD and C Dated 15.07.2020
Open Tender
Electrical Works
450 days
Phase-1, Udyog Vihar, Gurgaon
As per Tender Document
8 documents required · 8 mandatory
₹11,800
Yes
HVPNL
₹29 L
Yes
20 Apr 2021
15 Jul 2020
10 Sept 2020
15 Jul 2020
31 Aug 2020
15 Jul 2020
72.5kV, 1250A, single 3 – ø or three 1 –ø, SF6 gas insulated, metal enclosed bus bars arrangement, consisting of 1250A single 3 – ø or three 1 –ø SF6 gas insulated switchgears, each Bus Bar comprising of :- i ) Bus bar enclosures running through the length of the switchgear to interconnect each of the circuit breaker bay modules in double main bus system ii)Three, 2-core, single phase or single 3 – ø voltage transformers/ PTs. iii) 1250A, One 3 – ø or three 1 – ø, single pole, group operated isolator/disconnector and one, 3 – ø or three 1 – ø, single pole, group operated earthing switch with manual and motor driven operating mechanisms. iv) 1250A, One high speed fault make 3 – ø or three 1 – ø, single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms. v) Each GIS compartment with gas monitoring device, pressure switch etc. as required. vi) Terminal boxes/ Local Control Cubicle. vii) Interconnecting wiring/ piping. viii) Grounding, support structures and platforms.
72.5kV, 800A, single 3 – ø or three 1 –ø, Bus coupler bay module, consisting of 800A single 3 – ø or three 1 –ø SF6 gas insulated switchgears, comprising of: i) 800A, One 3 – ø or three 1 –ø, SF6 gas insulated circuit breaker, complete with operating mechanism. ii) Three,3-core,single phase current transformers(600-300-150/1-1-1A) iii) Two sets of isolator/disconnector switches each of 800A, One 3 – ø or three 1 – ø, single pole, group operated isolator/disconnector switches each with 3 –ø or three 1 – ø, single pole, group operated earthing switch and complete with manual and motor driven operating mechanisms. iv) Each GIS compartment with gas monitoring device, pressure switch etc. as required. v) Terminal boxes/ Local Control Cubicle. vi) Interconnecting wiring/ piping. vii) Grounding, support structures and platforms.
72.5kV, 800A, single 3 –ø or three 1 –ø, Transmission line feeder circuit breaker bay modules, consisting of 800A single 3 –ø or three 1 –ø SF6 gas insulated switchgears, each comprising of:- i) 800A, One 3 – ø or three 1 –ø, SF6 gas insulated circuit breaker, complete with operating mechanism for outgoing feeder. ii) Three, 66kV LAs and Voltage detectors /sensors iii) Three, 3-core, single phase current transformers(600-300-150/1-1-1A) iv) 800A, One 3 – ø or three 1 – ø, single pole, group operated isolator/disconnector without earthing switch, complete with manual and motor driven operating mechanisms. v) 800A, One 3 – ø or three 1 –ø, single pole, group operated isolator/disconnector with one, 3 – ø or three 1 – ø, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms. vi) 800A, One 3 – ø or three 1 – ø, single pole, group operated isolator/disconnector with one normal and one high speed fault make 3 – ø or three 1 – ø, single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms. vii) Each GIS compartment with gas monitoring device, pressure switch etc. as required. viii) Voltage detectors /sensors ix) Terminal boxes/ Local Control Cubicle. x) Interconnecting wiring/piping xi) Grounding, support structures and platforms.
72.5kV, 400A, single 3 –ø or three 1 –ø, Transformer feeder circuit breaker bay modules, consisting of 400A single 3 – ø or three 1 –ø SF6 gas insulated switchgears, for 66/11kV transformer, each comprising of: - i) One 3 – ø or three 1 – ø, SF6 gas insulated circuit breaker, complete with operating mechanism for incomer bay from 66/11kV transformer. ii) Three, 3-core, single phase current transformers (300-150/1-1-1A). iii) 400A, One 3 – ø or three 1 – ø, single pole, group operated isolator/disconnector without earthing switch, complete with manual and motor driven operating mechanisms. iv) 400A, One 3 – ø or three 1 – ø, single pole, group operated isolator/disconnector with one, 3 – ø or three 1 – ø, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms. v) 400A, One 3 – ø or three 1 – ø, single pole, group operated isolator/disconnector with two earthing switches each comprising of one 3 – ø or three 1 – ø, single pole, group operated earthing switches complete with manual and motor driven operating mechanisms. vi) Each GIS compartment with gas monitoring device, pressure switch etc. as required. vii) Local Control Cubicle. viii) Interconnecting wiring/piping. ix) Grounding, support structures and platforms.
a) 66kV XLPE copper Cable 1CX (400mm2) along with one no. spare cable coated with fire retardant Paint for connecting 66kV side of 66/11kV transformer with GIS.
b) Termination kit for both ends for 66kV XLPE copper Cable 1CX (400mm2).
25/31.5MVA, 66/11 kV Power T/F along with10% extra T/F oil (will be provided by HVPNL)
220V 100 AH Battery
66 kV Surge Arrestor
11 kV Surge Arrestor
66 kV NCT For 66/11kV T/F (300-150/1A)
11 kV NCT For 66/11T/F (1800-900/5A)
66kV C&R Panels i) Line Protection & Circuit breaker Panel (without auto reclose)
ii) T/F Protection & Circuit breaker Panel (without auto reclose)
iii) Bus Coupler Protection & Circuit breaker Panel (without auto reclose)
Time synchronization equipment
11 kV 15 Panel Board (2000A) with one SEM on each T/F I/C Panel (including one no. bus sectionalizer panel)
11 kV Power Cable XLPE 1C x1000mm2 coated with fire retardant paint for T/F to 11kV incomer with termination kit for both ends (4 runs per phase for each transformer allocating them 2 runs per phase for each 11kV I/C)
11 kV Power Cable XLPE 3C x 400sq mm coated with fire retardant Paint for Capacitor Bank with termination kit for both ends (2 runs)
11 kV Power Cable XLPE 3C x 50 sq mm coated with fire retardant Paint for station T/F with termination kit for both ends
6.804 MVAR 11 kV rating Capacitor Bank with 11 kV L&E Switch, RVTs and 11KV LA, reactor etc. as per technical specification.
220 V 100 AH Battery charger
220 V 100 AH D.C.D.B.
415 V LT AC Distribution Board 300 A
11/0.4 kV Station T/F 200 KVA
a). EOT-Crane as per clause 2.10.7 Section-1 and Clause 29.0 of GIS Specification. b). Mechanical Operated Crane as per clause 2.10.7 section-1 (each 1 No.)
1.1 kV Copper Control Cable armoured (FRLS) for 66kV bays & 11kV side of sizes 7CX4mm2, 2CX4mm2, 4CX4mm2, 2CX6mm2, 16CX2.5mm2, 10CX2.5mm2, 7CX2.5mm2, 3CX2.5mm2 etc. including junction box (as per Section-6 of copper control cable specification and Section-7 of Switchyard Erection).
650/1100 Volts 3.5 core 240 mm2 aluminium power cable (FRLS) from Aux. T/F to ACDB
650/1100 Volt 3.5 core 70 mm2 aluminium cable (FRLS) for oil filtration set.
650/1100 Volt 4 core 16 mm2 armoured (FRLS) copper power cable for MLDB etc and other cable required as per contract for 66kV bays.
Grounding system of the substation. Earthing Mat Material. The earth mat will be designed/quoted for soil resistivity of 50Wm. In case soil resistivity is more than 50Wm then the earth mat will be designed for actual soil resistivity. The payment of extra material to be used for earth mat shall be made on pro rata basis. The approximate area of earth mat to be laid is given in the corresponding columns of the substations. However, item will remain a Lot item. (850sq. mm approx.)
Fire Fighting Equipment as per section-6 i) 22.5 Kg Capacity FE CO2 type, Trolley Mounted
ii) 25 Kg Capacity FE DCP type, Trolley Mounted
iii) DCP 10 Kg Capacity, Wall mounted
iv) FE CO2 6.5 Kg Capacity, Wall mounted
v) DCP 5 Kg Capacity, Wall mounted
vi) Foam Type 9 Litre Capacity, Wall mounted
vii) Water CO2 9 Litre, Wall mounted
viii) Fire Buckets (12 Nos. with stand in one set)
Complete lighting of control room building, switchyard area, rod & street as per Section-7 of the Specification. a)Supply and installation of 2 fittings of 240W LED lamps with all accessories for Complete lighting of outdoor Switch yard area as per clause 16.0 of section 7 of the specifications.
b) Supply and installation of 35W LED tube on tubular steel poles along with the boundary wall at a distance of 30 meter as per as per clause 16.0 of section 7 of the specification
c) Complete lighting of road and street by providing 90W LED lamps on tubular steel poles at a distance of 15meter along the roads and streets as per as per clause 16.0 of section 7 of the specification.
d) Supply and installation of post top lantern 40W LED Lamps with all complete accessories at the entrance gate of sub-station.
e)Supply and installation of 40W LED Lamps with all complete accessories on corners of control room building.
High wall type spilt AC unit of 2 Ton capacity for computer room and C&R Panel Room (as per Technical specification)
Complete Substation automation system of 66/11kV substations including hardware (along with transducers) for 7 No. 66kV present bays and software (for present bays as well as 3 No. future bays) along with associated equipment for the bays (bay as defined in the technical specification, sec-sub-station automation system) as per technical specification.
Testing of IUM System at NABL accredited lab
66 kV bolted type single suspension string assembly with 6 numbers ANTI FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and suspension clamp set suitable for single Zebra ACSR. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators (type of insulator whether disc or polymer insulator to be identified at the time of bidding and quoted accordingly which will not be altered at later stage by the bidder).
Bolted type 11kV Single tension string assembly with 3 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and tension clamp sets suitable for Twin tarantulla Conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators (type of insulator whether disc or polymer insulator to be identified at the time of bidding and quoted accordingly which will not be altered at later stage by the bidder).
Boltless C-Wedge connectors matching with conductor size.
Spacers suitable for twin tarantulla conductor
Copper lugs glands, PVC ferrules for control cabling.
Fibre cleats, Aluminium clamps, bolts, nuts, washers etc for fixing control cables in trenches
a) Galvanized iron perforated tray with side coupler plate bolts, nuts, washers and clamps etc. of size 75x25x2 mm, 150X25X2mm, 100X25X2mm etc. & G.I. Conduits of 50mm/100mm dia from equipment to main trench as per Section-7, Switchyard erection. b) Painted lattice type steel trays of adequate size as per site requirement for laying control and power cables from panels (placed on top floor) to GIS & Transformers and for 11kV Outgoing cables & other cables identified as per site requirement confirming to Section-7 & 9. (Each 1 L/S).
Twin Tarantulla Conductor (approx)
ACSR Single Zebra Conductor (approx)
7/3.15 Earthwire
U-bolt 20mm dia
Lattice type steel structure for 66kV GIS S/Stn.Udyog Vihar, Phase-I, Gurugram. Supply of material, preparation of fabrication drawing, galvanizing and delivery of lattice type steel structure for tower and beams for 66/11kV switchyard fabricated from steel conforming to IS:2062 including nuts-bolts gusset plates foundation bolts and other accessories as per drawings supplied by the owner. Main S/Stn. Tower and beam i) Tower type CT-4 (HW/ST-5199)
ii) Tower type CT-5 (HW/ST-5195)
iii) Beam type CB-6 (HW/ST-10)
iv) Tower type DT-2 (HW/ST-5210)
v) Tower type DT-3 (HW/ST-5211)
vi) Beam type DB-2X (HTD/ST-154)
Equipment Supporting Structure i) 66 kV NCT Drg. No. HTD/ST-145
ii) 66 kV Surge Arrestor Drg. No. HTD/ST-89R
iii) 11 kV NCT Drg. No. HTD/ST-149
iv) 66kV Cable structure of galvanized iron along with foundation to be designed by bidder as per site requirement/size of cable
1.0 Equipments for maintenance i) Portable circuit breaker operation analyzer.
ii) Digital Micro-Ohm meter for contact resistance measurement Ranges (0-100 ohm) (0-1 milliohm), (0-10 milliohm).
iii) Dew Point meter
iv) Portable partial discharge monitoring system for GIS.
v) SF-6 Gas filling and evacuating plant
vi) SF-6 Gas leak detector (Portable)
vii) Tools for gas handling
viii) LT DC Leakage detector from control cabinets and LT cables
2.0 Common Spares, Maintenance and Testing Tools (66 KV) i)SF6 Gas pressure relief devices
ii) Pressure gauges (of each type) along with coupling device
iii)Rubber Gaskets, “ o” Rings and seals for SF6 Gas (each type)
iv) Molecular filter for SF6 Gas with filter bags (20% of total weight)
v) Density Monitors for SF6 Gas (each type)
vi) All types of Control Valves for SF6 Gas (each type)
vii) SF6 Gas of total gas requirement 20% (each no. 1)
viii) Enclosures, Insulators & main circuit to replace on each phase, any compartment of Busbar or bay (each type)
ix) Covers with all accessories necessary to close a compartment in case of dismantling of any part of the enclosure to ensure the sealing of this compartment (as applicable) a) For 3 Phase Enclosure
b) For Single phase enclosure
x) Locking device to keep the Disconnectors (Isolators) and Earthing switches in close or open position in case of removal of the driving Mechanism
xi) Bus Support insulator of each type for 3 phase/single phase enclosure (5% of total population)
xii) Pipe length (Copper or Steel as applicable) for SF6 Circuit of each type
xiii) SF6 to air bushing (66 KV of each type & rating) (each)
3.0 CIRCUIT BREAKERS (66 KV) i) Complete Circuit Breaker pole of each type & rating complete with interrupter, main circuit, enclosure and Marshalling Box with operating mechanism
ii) Fixed, moving and arcing contacts including insulating nozzles, (3 Nos. of each type)
iii) Rubber gaskets, `O' rings and seals for SF6 gas of each type
iv) Trip coil assembly with resistor as applicable, 3 Nos. of each type
v) Closing coil assembly with resistor as applicable, 3 Nos. of each type
vi) Molecular filter for SF6 gas with filter bags (10 % of total quantity used)
vii) SF6 Pressure gauge cum switch OR Density monitors and pressure switch as applicable, 3 Nos. of each type
viii) Coupling device for pressure gauge cum switch/ for connecting Gas handling plant, 3 Nos. of each type
ix) Corona rings if applicable
x)Relays, Power contactors, push buttons, timers & MCBs etc of each type & rating
xi) Closing assembly/ valve, 3 Nos. of each type Set
xii) Trip assembly/ valve, 3 Nos. of each type
xiii) Auxiliary switch assembly, 3 Nos. of each type
xiv) Operation Counter, 3 Nos. of each type
xv) Rupture disc, 3 Nos. of each type
xvi) Wind scope/ Observing window, 3 Nos. of each type, if applicable
xvii) Spring operated closing mechanism, 1 No. of each type, if applicable
xviii)Terminal Pad & connectors
4.0 Isolators , E/Switch & High Speed E/Switch (66 KV) i) Complete set of 3 nos. of single phase / one no. of 3-phase dis-connector including main circuit, enclosure, driving mechanism.
ii) 3 nos. of single phase / one no. of 3-phase Earthing switch including main circuit, enclosure, driving mechanism.
iii) Copper contact fingers for dis-connector male & female contact – for one complete (3 phase) dis-connector of each type and rating.
iv) Copper contact fingers for earthing switch male & female contacts, for one complete (3 phase) earthing switch of each type and rating
v) Open / Close contactor assembly, timers, key interlock for one complete (3 phase) dis-connector and (3 phase) earthing switch of each type and rating
vi) Push button switch.-each type, as applicable
vii) Limit switch and Aux. Switches for complete 3 phase equipment a) For isolator
b) For earth switch
viii) Rotor housing bearing assembly for complete 3 phase equipment a) For isolator
b) For earth switch
ix) Motor with gear assembly for complete 3 phase equipment a) For isolator
b) For earth switch
x). Corona shield rings as applicable
xi) Hinge pins for complete 3 phase equipment a) For isolator
b) For earth switch
xii) Bearings for complete 3 phase equipment a) For isolator
b) For earth switch
xiii) Interlocking coil with resistors, timers, key interlock for complete 3 phase
xiv) Relays, Power contactors, resistors, fuses, push buttons & MCBs a) For isolator
b) For earth switch
xv) Terminal pad and connectors (complete for one 3 phase equipment) a) For isolator
b) For earth switch
xvi) Aux. switch assembly (complete) with 10 NO & 10 NC OR more contacts
xvii) 72.5 kV, 1250 A, 3 – ø or 1 – ø high speed fault making grounding switch, Internal parts complete with all necessary gaskets mounting hardware etc.
xviii) 72.5 kV, 1250 A, 3 – ø or 1 – ø high speed fault making grounding switch operating mechanism complete with all necessary gaskets connecting apparatus.
5.0 Current Transformer, i) 66kV 1 ph CT ratio 600-300-150/1-1-1A complete with all gaskets and mounting hardware
ii) 66kV 1 ph CT ratio 300-150/1-1-1A complete with all gaskets and mounting hardware
6.0 Voltage Transformer/PT(66 KV), i) 66kV, 1-phase VT as per technical specifications complete with all gaskets and mounting hardware.
Civil Works 1.0 GANTRY TOWER/EQUIPMENT FOUNDATIONS Supply of labour, T&P, material and construction of RCC footings & pedestals etc. for steel gantry and equipment structures complete in all respects as per technical specifications & drawings attached with the tender document including cost of excavation, concreting, cement, reinforcement steel, form work, grouting, holding down bolts, backfilling etc. and other items not mentioned herein but required for the completion of work. A. Gantry Towers i) CT-4
iii) DT-2
B. EQUIPMENT i) 66kV LA
ii) 66kV NCT
iii) 11kV NCT
2.0 CABLE SUPPORT STRUCTURE Design, Engineering, supply of labour, material and construction of cable support structure foundations including all associated works, RCC, PCC, reinforcement steel, misc. structural steel and other items not mentioned herein but required for the completion of work as per technical specification. i) 66kV Cable Support Structure
3.0 OUT DOOR CABLE TRENCHES : Supply of labour, material such as cement, R/F steel, steel angles, flats, PCC and brick pillars below cable trenches for construction of Out Door Cable Trenches (ODCT) of required depth/type with pre-cast RCC covers including associated works like Cable Trench Culverts crossings for roads and collection chamber with 2HP morter, starter volt meter & amp-meter as per approved Trench layout plan, HVPNL drawings & technical specifications complete in all respect.
4.0 ROADS : Supply of labour, material and construction of cement concrete roads and walkways/shoulders from NH/SH/etc. to Switch yard/Switch house building as per GELO/CLO as per sectional detail drawing no. HCD/SK-181 R1 and technical specification. i) 6.0M from approach road.
ii) 5.0M wide as per GELO/CLO.
iii) 3.66M wide
5.0 ROAD CULVERT : Design, Engineering and const. of Pipe/RCC culvert(s) at suitable locations under the approach road (from main PWD/ HUDA/Municipal/Village road to the sub-station entry point) including, cost of labour, material complete in all respects as per I.R.C. Standards
6.0 PCC PAVEMENT : Construction of PCC pavement in front, rear/side (as per site conditions) of the switch house building as per drawing no. HCD/SK-172 & tech. specifications.
7.0 TRANSFORMER FOUNDATION : 7.1 Design, Engineering, supply of labour, T&P and material including RCC, PCC, Reinforcement steel, misc. structural steel and other item(s) not mentioned herein but required for the completion of work as per technical specifications for construction of below mentioned transformer foundations. i) 200 KVA, 11/0.4kV Station Transformer
7.2 Construction of transformer foundation including all associated works, RCC, PCC, reinforcement steel, misc. structural steel and other items not mentioned herein but required for completion of work as per technical specifications & drawing attached. In case extra foundation(s) or extra depth has/have to be constructed (as per approved T/F drawing) to complete the job, nothing extra would be paid on this account. i. 25/31.5MVA, 66/11kV T/F
8.0 CAPACITOR BANK FOUNDATIONS:Design, Engineering & supply of labour, material & construction of foundations for following rating capacitor bank with L&E switch, RVTs, LAs, capacitor unit and series Reactor etc. including chain link fencing 1.8M height around capacitor bank complete in all respect including any other items not specifically mentioned herein but required for completion of job as per technical specification. i) 6.804 MVAR 11kV capacitor bank with associated equipments complete.
9.0 SITE SURFACING: 9.1 Providing, supplying & laying 100mm thick two layers of uncrushed/crushed/broken stone/ pebbles gravel fill. The first layer after compaction shall make min. 50mm thickness course/layer of 40mm nominal size, including dressing, rolling & compaction complete as per specifications, GELO and instructions of XEN/Civil Works Division.
9.2 Providing, supplying & laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates & spreading 100mm thick layer of 40mm nominal size uncrushed/crushed/broken stone/ pebbles over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 40mm size uncrushed/crushed/ broken stone/pebbles wherever required in the bays covered under the present scope as detailed in the GELO & instructions of XEN/Civil Works Division.
10.0 BOUNDARY WALL 10.1 Supply of labour, material and providing:- (A) two coats of exterior acrylic emulsion paint on 6 ft. high U/C B/wall, 4½ ft. high front wall, 4½ ft. high side wall, main gate pillars including prepration of surface, cement based putty etc. as per GELO/CLO, tech. specs. of HVPNL. (B) Synthetic Enamel paint on gates and grill as per GELO/CLO, tech. specs. of HVPNL.
11.0 U/C FENCING & GATES : Providing & fixing chain link fencing including foundations, GI angle iron posts and gate(s) complete as per electrical layout & tech. spec. & as per drawing attached.
12.0 MULTI STOREY GIS HALL: Design including architecture and structure design/drawings, Engineering, supply of labour, T&P and material etc. for construction of multi storey GIS Hall comparising of ground, intermediate and 1st floor ( to accumulate 66kV GIS hall & Control Room Building ) including exterior weather proof paint, interior emulsion, all internal services like water supply including supply and providing of 5000ltr. Capacity double layer Sintex/Diplast PVC tank, Sewerage System, electrification including wiring, modular switches, lighting, maximum 20W 4ft. long LED tubes with fittings minimum 1960 lumens etc. ceiling/exhaust fans, plinth protection, Indoor trenches, Erection of EOT crane system and mechanical operated crane system adjacent to building, Soakage pit near the switch house building or connection of sewerage system to Soakage pit/sewerage system of local authority(as applicable ), connection to main water supply system of local authority, bore (as applicable) etc. and any other item not mentioned herein but required for completion of job as per specifications. Minimum size of the buildings has been provided in the GELO. Since the detailed engineering is in the scope of the successful bidder, no claim for increase in size of the building shall be admitted.
13.0 DRAINAGE-CUM-RAIN HARVESTING SYSTEM: 13.1 Supply of labour, material for construction of 1 no. recharge structures with bore well(s) as per HVPN drawings & specs. complete in all respect. The location of recharge structures shall preferably be located on corner(s) of the s/stn. & shall be got decided from concerned XEN/Civil Works Division on the basis of surroundings of the s/stn.(s). In case ground water table is less than 8m from FGL, rain harvesting well shall not be constructed (the drainage system with sump pit is to be constructed as per item mentioned below).
13.2 The successful bidder shall evolve design & drawing for drains, manholes with RCC covers and settlement tank including preparation of drainage layout drawing for disposal of rain water from building’s roof top & switch yard (s/stn.) area into bore well in such a way that there shall be no ponding of water on the roof and switch yard (s/stn.). The layout so developed shall be got approved from the employer. The location of sump-pit-cum-pump chamber shall preferably be located on corner(s) of the s/stn. and shall be got decided from the concerned XEN/Civil Works Division on the basis of surroundings of the substation(s). The successful bidder will also supply labour and material for construction of sump-pit-cum-pump chamber as per HVPNL drgs. & provide one no. non clog pump of 5HP of reputed make capacity with main switch, starter, volt meter, Amp. Mtr. etc. for disposal of excess water to outfall point. Any other item(s) not mentioned herein but is/are required for completion of works shall be done by the successful bidder without any extra cost to the employer.
14.0 RCC M-20 inclusive of labour, material, shuttering, Steel reinforcement etc. complete in all respects to compensate excess quantity required to execute difference in execution & tender drawings only due to increased depth of foundations.
BOQ for supply and Erection of LILO of one circuit of 66kV Dundahera Ph-IV – Sec-23A D/C Line at proposed 66kV S/Stn Udyog Vihar Ph-I (GIS) HSIIDC Gurgaon through underground cable (8) core) of size 1200sq mm2 by HVPNL from sr. No. 86 to 91. 1) . Detailed Survey (tentative route length: 33mtr.) Supply, Laying, Testing & Commissioning of Double Circuit 66kV 1200 mm2 Single Core Aluminium Conductor Milliken type, XLPE insulated Cable as per technical specification including loops and riser in trefoil formation with one spare cable for each circuit (6+2) and civil works complete in all respect including Manholes for jointing Bays, if required, on through rate basis as per technical specification with (tentative route length of directly buried cable (33Mtr), length of loops & riser (10+10=20) Total 33+20=53 mtr.) 53x8=424
2) Supply, Erection, Testing & Commissioning of Indoor End Terminations as per technical specification suitable for above cable & GIS termination as per, bidder’s design
3) Supply, Erection, Testing & Commissioning of 1 x 240mm2, Copper Conductor, PVC insulated, Unarmoured, 3.3 KV Sheath Bonding cable (to be decided as per requirement)
4) Supply, Erection, Testing & Commissioning of Straight Through Joints for each cable
5) Supply and Erection of Warning Tape
6) Supply, Erection, Testing & Commissioning of single phase Link Box with-out SVL for each cable (to be decided as per requirement)
BOQ for supply and errection of Creation of double circuit underground XLPE cable of size 1200sq mm2 (8 single core cable) from 220kV S/Stn Sec-20 to HSIIDC phase-I Udyog Vihar (GIS) (Tentative route length - 0.033kM) from Sr No. 92 to 108 1) Detailed Survey (tentative route length: 33mtr.) Supply, Laying, Testing & Commissioning of Double Circuit 66kV 1200 mm2 Single Core Aluminium Conductor Milliken type, XLPE insulated Cable as per technical specification including loops and riser in trefoil formation with one spare cable for each circuit (6+2) and civil works complete in all respect including Manholes for jointing Bays, if required, on through rate basis as per technical specification with (tentative route length of directly buried cable (33Mtr), length of loops & riser (10+10=20) Total 33+20=53 mtr.) 53x8=424
2) Supply, Erection, Testing & Commissioning of Indoor End Terminations as per technical specification suitable for above cable & GIS termination as per, bidder’s design
3) Supply, Erection, Testing & Commissioning of 1 x 240mm2, Copper Conductor, PVC insulated, Unarmoured, 3.3 KV Sheath Bonding cable (to be decided as per requirement)
4) Supply, Erection, Testing & Commissioning of Straight Through Joints for each cable
5) Supply and Erection of Warning Tape
6) Supply, Erection, Testing & Commissioning of single phase Link Box with-out SVL for each cable (to be decided as per requirement)
7) Detailed Survey, supply, laying, testing & commissioning of armoured Underground Fibre Optic Cable (24 fibre) in PLB HDPE Ducts of suitable size & strength alongwith accessories (as per requirement) in above mentioned sections, installation of joint boxes, interfacing with existing OPGW on through rate basis as per technical specification (through trench less method).
8) Detailed Survey, supply, laying, testing & commissioning of armoured Underground Fibre Optic Cable (24 fibre) in PLB HDPE Ducts of suitable size & strength alongwith accessories (as per requirement) in above mentioned sections, installation of joint boxes, interfacing with existing OPGW on through rate basis as per technical specification (open cut trench)
9) FODP 48F: Indoor type, rack mounted with FCPC coupling and pig tails (5mtrs. Each) as applicable at 66kV S/Stn. Udyog Vihar Ph-I and 220kV S/Stn., Sector-20, Gurugram.
10) (1.0) Telecom Equipment at 66kV S/Stn. Udyog Vihar Ph-I end (Note-8*) A) SDH Equipment (STM - 16 MADM upto 5 MSP protected directions) i) Base Equipment (Common cards, Cross connect/control cards, optical base cards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF etc. fully equipped excluding (ii) & (iii) below
ii) Optical Interface Cards/SFP a) S16.1 SFP (the quantities will be decided at the time of detail engineering)
b) L16.2 SFP (the quantities will be decided at the time of detail engineering)
c) S4.1 SFP (the quantities will be decided at the time of detail engineering)
d) L4.2 SFP (the quantities will be decided at the time of detail engineering)
iii) Tributary cards a) E1 Interface card ( Min. 32 interfaces per card)
b) Ethernet Interface 10/100 Base T with Layer-2 switching (Min. 8 interfaces per card)
c) Gigabit Ethernet (Layer 2) Interface (min. 2 nos.)
B. Equipment Cabinet with DDF and all installation accessories
2.0 Network Manager System - Craft Terminal a) Hardware
b) Software
3.0 VOIP telephone instrument with one common switch(min. 8 port) compatible with SLDC
4.0 Integration of the Equipment with existing network
Mandatory Spares Transmission Equipment II. Optical Interface Cards/SFP a) S16.1 SFP (the quantities will be decided at the time of detail engineering)
b) L16.2 SFP (the quantities will be decided at the time of detail engineering)
c) S4.1 SFP (the quantities will be decided at the time of detail engineering)
d) L4.2 SFP (the quantities will be decided at the time of detail engineering)
III. Tributary cards a) E1 Interface card ( Min. 32 interfaces per card)
b) Ethernet Interface 10/100 Base T with Layer-2 switching (Min. 8 interfaces per card)
c) Gigabit Ethernet (Layer 2) Interface (min. 2 nos.)
B. Pre Connectorized Optical Fibre Patch Cords (10 Mtrs.)-Pack of six Patch cords
Blue Star Ltd.
Hartek Power Private
SALASAR TECHNO ENGINEERING LIMITED
sumaja electroinfra pvt ltd
suncity Enterprises
K. Ramachandra Rao Transmission and Projects Pvt. Ltd.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid