Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹6.7 LAccepted-AOC VPO KANHETI TEHSIL DISTRICT CHARKHI DADRI 127306 | CHARKHI DADRI | CHARKHI DADRI | HARYANA | 127306 | L-1 | Accepted-AOC accepted | |
| 2 | L-2₹6.8 L+₹10,116 (1.50%)Rejected-AOC HOUSE NO 8 VILLAGE ALAWALPUR BAWAL REWARI VILLAGE ALAWALPUR BAWAL REWARI 123501 | BAWAL | REWARI | HARYANA | 123501 | L-2 | Rejected-AOC rejected | |
| 3 | L-3₹8.3 L+₹1.6 L (23.2%)Rejected-AOC 121004 | L-3 | Rejected-AOC rejected | |
| 4 | L-4₹8.4 L+₹1.7 L (24.5%)Rejected-AOC | L-4 | Rejected-AOC rejected | |
| 5 | Rejected-Technical | - | Rejected-Technical ENLISTMENT NOT FOUND |
Tender Value
₹7.8 L
EMD Value
₹15,520
Closing Date
14 Jan 2020, 3:00 pmClosed
RAVINDER KUMAR, EXECUTIVE ENGINEER
EXECUTIVE ENGINEER, PUBLIC HEALTH ENGINEERING DIVISION BAWAL
Badhrana Detailed estimate for providing and installing 1 No. additional tubewell and connecting pipe line Drilling of 2 No. tube well at village Ransi Majri and Jaisinghpur Khera through local Bocky machine and DTH.
2020_HRY_114384_1
PHED/BAWAL/ 11-75
Open Limited
Civil Works - Others
Works
120 days
RANSI MAJRI AND JAISINGHPUR KHERA
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
EXECUTIVE ENGINEER
₹15,520
Yes
2 Jun 2020
6 Jan 2020
15 Jan 2020
6 Jan 2020
14 Jan 2020
6 Jan 2020
Amount
Drilling of 230 MM dia bore by local bookie type machine in all kind of soils and boulders upto 130 mm dia except rocky strata including the cost of all consumable stores, fuel, oil, soil stabilizing material and transportation of rig and other accessories to the site of proposed bore and back (including cost of lowering of all sizes of casing pipe while boring and extracting the same against earth frictions etc.) complete to the satisfaction of the Engineer-in-charge. Drilling from 0 to 110 and 0 to 95 mtrs 110 mtr. + 95 mtr. = 205 mtr.
Drilling of 200 mm dia bore by DTh rig as per ISI code 2800-1991 (part-I) and 2810-1979 as amendment up to in all kinds of soil including cost of all consumable store,oil soil stablishing material to the site of proposed bore and back complete in all respect Drilling from 95 to 165 mtrs = 70 mtr.
Supplying and lowering 219.10 mm outer dia ERW steel pipes as per IS 4270-1992 as amended pipe in 4 to 7 meters random length with 88.90mm of threaded ends (8 threads to an inch or 25.40mm) manufactured out of 6.40mm thick MS plates with required number of MS socket 177.80 length with inside thread to match the pipe threads and made out of MS plate in to borehole in vertical position including cost of all scaffolding, derricks, Jim, poles, tools and plants, ropes, gays MS clamp embedded in foundation etc. complete in all respects to the satisfaction of the Engineer-in-Charge of the work including cost of all cutting, threading of pipe, welding where required and all sockets ( 92 mtr. + 72 mtr.= 164 mtr.)
Supplying and lowering 219.10mm outer dia mild steel slotted pipes to be as per is 4270-1992 amended upto date and duly ISI marked in random length of 4 m to 7 m with design of slots as IS : 8110-1995 and ISI 2800/1991(Part-I) with amended upto date with checricumferential weld made out of 7.04m thick MS sheet. These will also be screwed and sockets and with required number of MS socket of specification as epr item No.3 above for jointing the slotted length and plain ERW steel pipe.(M.S. screen ) ( 18 + 18) = 36 mtr.
Supplying and fixing well threaded M.S. cap for 219.10mm outer dia M.S. pipe as per ISI 226/1975 as amended upto date to the satisfaction of the Engineer-in-charge
Development of T/well according to clause 9.3 of IS: 2800-1991 (part-I) as amended upto date and specifications attached and as directed by the Engineer-In-Charge of the work including the cost of all consumable stores, fuel, oil, compressors, pumps and machinery etc. as required for this work. When developed by compressor of 450 CFM, 250 PSI and suitable rating of 10 hrs.
Supplying, erection testing and commissioning of submersible pumping sets as per BIS specification No. 8034-1989 9as amended upto date for pumps. The pumping set of 15.00 BHP, 250 LPM discharge and 150 mtrs. Head of CRI make.
Supply, erection, testing and commissioning wall mounted electric testing and commissioning of wall mounted electric panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angel iron frame work and completely powder coated of appromximate size 1350x750 mm and 400mm deep having following items) a) Main switch 63 Amp. 1 No. (L&T, Siemens, ABB) b) Volt meter 100x100 range 0 to 500 volt 1 No, (AE/KAPPA/L&T) c) Volt meter 100x100 range 0 to 100 volt 1 No, (AE/KAPPA/L&T) d) CT 100/3 No. (AE/KAPPA/L&T) e) VSS & ASS 1 No. of approved make f) SPP 1 No. of approved make. g) Motor starter Star Delta 1 No. (L&T/Siemens/ABB) h) Capacity KVAR as per site requirement i) Indicating lamp one set
CI Specials of ISI Marked Tees, Bends, reducers etc. for pipe line at head works all specials duly ISI marked
GI Specials of ISI Marked Tees, Bends, reducers etc. for pipe line at head works all specials duly ISI marked
Bidder Name
Amount
Yadav Enterprises
Satyapal Singh Contractor
Sandeep Kumar Contractor,Deroli Jat
PARVEEN KUMAR
Yadav Enterprises
PARVEEN KUMAR
Sandeep Kumar Contractor,Deroli Jat
Yadav Enterprises
PARVEEN KUMAR
Sandeep Kumar Contractor,Deroli Jat
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .