Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹14.3 LAccepted-AOC 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | 1 | Accepted-AOC Lowest bidder | |
| 2 | 2₹16.6 L+₹2.0 L (13.4%)Rejected-AOC | 2 | Rejected-AOC 2nd | |
| 3 | 3₹17.2 L+₹2.6 L (17.5%)Rejected-AOC | 3 | Rejected-AOC 3rd | |
| 4 | 4₹21.5 L+₹6.8 L (46.3%)Rejected-AOC A 93 SECTOR 36 GREATER NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201308 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201308 | 4 | Rejected-AOC 4th |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
2 Dec 2023, 6:00 pmClosed
GE AF TUGHLAKABAD
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
SPECIAL REPAIR/REPLACEMENT TO WIRING, ELECTRICAL FITTINGS AND FIXTURES IN CERTAIN SMQs AT 7 BRD AND PROVN OF SPLIT TYPE ACs AT VARIOUS LOCATION AT 7 BRD UNDER GE (AF) TUGHLAKABAD
2023_MES_626597_1
GE/TKD-64/2023-24
Open Tender
Civil Works - Others
Item Rate
180 days
GE AF TUGHLAKABAD
MES contractor enlisted having deposited Standing Security with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
9 documents required · 9 mandatory
₹500
GE AF TUGHLAKABAD
₹52,000
Yes
24 Jan 2024
3 Nov 2023
4 Dec 2023
10 Nov 2023
2 Dec 2023
17 Nov 2023
Amount
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR as shown Note: 1) Making hole in wall, insulation of copper tubes, stand for outdoor unit (wall mounted/roof top type), T&P required for installation & making good the disturbed surface is deemed to be included in quoted rates.
Supply and fixing Industrial socket sheet metal enclosure with socket plug top and MCB single pole and neutral with a two pin and earth plug and socket with one single pole MCB of 20 Amp complete all as specified and directed by Engineer-in-charge.
Taking down old UNSV split,window AC included metal clad socket, copper tubes, included outdoor unit from various location and keep at MES yards or store all as specified and directed by Engineer-in-charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 160 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA, complete all as specified and directed by Engineer-in-charge.
M&L Sub main wiring complete with non-metallic rigid PVC insulated fire retardant grade unsheathed 1100V grade multistranded copper conductor cable 2 run of 4 Sqmm single core confirming to IS-694 with copper conductor drawn through PVC casing capping/conduit heavy duty and accessories in walls, roof and floors along with 1 run of 4 Sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity conductor complete including chase cutting by cutter concealed in PVC conduit all as specified and as directed by Engineer-in-Charge. Make: Plaza/Havells/Finolex/Kallinga
Taking down carefully copper/aluminium point wiring (light, Fan, Socket or power) fitting such as switches, ceiling roses, pendents, regulators, sockets etc complete removing material to store for keeping in safe custody and making good disturbed surfaces of walls, floors etc all as specified as directed.
Material & Labour for concealed point wiring with single core PVC insulated and unsheathed 1100 volts grade cable with multistranded copper conductor of size 1.5 Sqmm nominal area drawn through & including non metallic rigid PVC conduit (circular/flat pvc conduit), medium duty not less than 20 mm dia concealed in wall/fixed with all fittings including tees , junction boxes, modular GI gang box & provision for modular box and modular cover of suitable size for mounting modular switches , sockets & regulators & drawing through continuous earth wire of PVC insulated unsheathed 1100 volts grade cable with copper conductor solid conductor of size 1.5 sqmm complete all as specified & directed by Engineer -In-Charge. Note: 1) Cost for cutting chases and making good to match the existing surface shall be deemed to be included in the quoted rate. 2) Rates are deemed to be inclusive of Modular GI gang box & cover plates of any module & Qty as required on site.
For one light point/call bell controlled by one single pole switch & socket.
For one fan/exhaust fan point controlled by one single pole switch.
For one 3 pin sockets outlet 5 Amps on the same board with other switches with cable of size 1.5 sqmm
For 3 pin socket outlet 5Amps independent with cable 1.5 Sqmm size
For one 3 pin sockets outlet 15 Amps idependent with cables 2.5sqmm size
Supply and Fixing in replacement of modular switches 1 way, 6 Amp 1 module complete all as specified & directed by Engineer - In-Charge.
Supply and Fixing in replacement of modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified & directed by EIC.
Supply and Fixing in replacement of modular switches 1 way, 16 Amp 1 module complete all as specified & directed by Engineer - In-Charge.
Supply and Fixing in replacement of modular Socket 6A/16A - 2/3 pin combined 2 module, complete all as specified & directed by Engineer - In-Charge.
S&F in replacement of Single pole and neutral metal clad enclosure with a two pin and earth including plug and socket complete set with one single pole MCB of 20 Amps,complete all as specified and directed.
S&F in replacement of Fan modular fan regulator 4 step, 1 module, complete all as specified & directed by EIC.
S&F in replacement of Modular Bell push 6A 1 module, complete all as specified & directed by Engineer - In-Charge.
S&F in replacement ofDing Dong AC. 230 volts, single pole, complete all as specified & directed by Engineer - In-Charge.
Supply & Fixing in replacement of Ceiling Rose, 3 phase polycarbonate isolated body complete all as specified & directed by Engr-In-Charge.
M&L for Taking out the unserviceable wall mounted Panel board including all connection and supply, installation, commissioning and testing of LT panel, indoor type, double door, IP 65 Protection, CPRI Approved base frame mounted dust proof and vermin proof with bus bar of 200 Amps current capacity to accommodate 3 Phase, 415Volt with suitable aluminium busbar designed as per relevant IS connected to busbar by aluminium strip of suitable Size, fabricated out of 3.15 mm thick CRCA sheet for outer chamber and 2 mm thick for partition and doors and painting with seven tank process with twin shutter closing, locking arrangements and with 2 nos earthing sprout connectors complete and fixed in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in foundation 40 cm above ground level including provision for fixing of MCCB160A, 16 KA, 4Pole -1 Nos (Incomer), Digital VAF Meter, LED Indication Lamps, CT's etc and outgoing MCCB 100A, 16KA, 3 Pole-2 Nos, outgoing mcb 40 A, k0 KA, 4 pole - 1 nos, along with spare space for fixing of 01 Nos MCCB complete control wiring for the above accessories all as specified and as directed.
Supply and fix in replacement of factory made epoxy polyster powder coated VTPN distribution board 8 way with incomer MCCB of 100Amps, 4 pole, 16KA, fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-54 protection) fixed on wall and standard DIN rail, earth bar and cable ties for cable management, suitable for one incoming and 6 outgoings complete all as specified and confirming to IS: 8623 Note: (i) Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate.
Supply and fix in replacement of factory made epoxy polyster powder coated distribution board SPN 6 way fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, suitable for one incoming and 6 outgoings complete all as specified and confirming to IS: 8623 (Make: Legrand /Siemens). Note: Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate.
S&F in repalcement of MCB SP 6-32 Amps,10 KA 230 Volts, 50 Hz complete all as specified and as directed by Engr-in-charge.
S&F in repalcement of MCB SPN 32 Amps,10 KA 230 Volts, 50 Hz complete all as specified and as directed by Engr-in-charge.
S&F in repalcement of MCB SP 63 Amps,10 KA 230 Volts, 50 Hz complete all as specified and as directed by Engr-in-charge.
S&F in replacement of MCCB 100 Amps, 16 KA, 4 Pole, with thermal & megnetic release setting, including spreader, complete all as specified and directed by Engr-in-charge.
S&F in replacement of submain wiring with unsheathed multi-stranded FR Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 4 Sqmm single core HR Grade and one run of 2.5 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB/ Geyser/ AC plug points complete all as specified and as directed. Note :- (i) Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall. (ii) Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit.
M&L in replacement of Earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron strip 25×4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated complete all as specified and directed.
S&F in replacement of LED retrofit tubelight, 4 ft long of 20 watt, complete all as directed.
S&F in replacement of LED 2 ft retrofit tubelight of 10 watt, complete all as directed.
S&F in replacement LED building light/ street light of 45 watt,230V pressure die cast aluminium housing ,heat resistant toughned glass with frame,IP Protection IP 66 battery optics for uniform distribution aving surge protection 10 KV sealed driver complete all as specified and as directed by Engineer -in-charge. Make: Crompton cat No: LSTS-45-CDL or equivalent make of Philips /Wipro/C&S/Havell's Note: Twin core copper wire of 1.5 Sqmm upto 7Rm required for connection of street light fitting is deemed to be included in quoted rates
S&F in replacement of GI Pipe Street light bracket made out of 40mm dia light grade GI pipe 1.5 mtr long and make to shape fixing with suitable size of Flat iron clamp nut, bolt and washers connection including two coats of synthetic enamel paint over a coat of red oxide primer and fixing light fitting on bracket and all electrical connection comlete all as specified and directed by Engr-in-Charge
S&F in replacement exhaust fan made of sturdy engineering plastic complete with louvers shutter working voltage 230 V ,50 Hz 1200 RPM copper winding of sweep 300 mm complete with blade, connecting up and including provision of three core flexible copper wire of size 23/0.0076 from ceing rose to exhaust fan including make necessary arrangement to fix on wall/window complete all as specified and directed. (Note- Existing old/unsv exhaust fan to be deposited to E/M store for completion of BER board)
S&F in replacement Electric Water heater storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 Ltr BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc. Note- Existing old/unsv Electric Water heater to be deposited to E/M store for completion of BER board.
S&F in replacement ceiling fans complete with blades, down rods, electronic regulator and accessories 230 V 1200 mm sweep. Min Air delivery 210 CFM with service value 6.00 BEE Five star rated with Brushless Direct current motor(BLDC) Note- Existing old/unsv ceiling fans to be deposited to E/M store for completion of BER board.
Dismantling and refixing ceiling fan after complete cleaning of dust, applying a coat of painting on ceiling fan complete with synthetic enamel paint by spraying including filling cavities with filler, writing MES Noon ceiling fan and connecting up and including provision of cable from ceiling rose to connector to foundation complete all as specified and directed.
Dismantling & refixing only exhaust fan after complete cleaning all dust, one coat of painting of exhaust fan complete with synthetic enamel paint by spraying including filling cavities with filler, writing MES No on exhaust fan and connecting up and including provision of cable from ceiling rose to connector to fdn complete all as specified and directed.
Dismantling & refixing water storage type of 25 Ltrs complete with help of anchor fasteners, nuts, bolts makingh necessary electrical connections and water connection with new PVC Connection of 15 mm size heavy duty internally steel coated ISI Marked of length 600 mm complete all as specified and directed
Dismantling & refixing LED Tube Light any type and size complete with clamp making necessary electrical connections complete all as specified and directed by Engr-in-Charge.
M/S Delhi Engineering Co.
SRA Engineering
Deepak Electricals
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .