Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L1 | Accepted-Finance OK | |
| 2 | L2₹33.9 L+₹2.7 L (8.78%)Accepted-Finance | L2 | Accepted-Finance OK | |
| 3 | L3₹35.2 L+₹4.1 L (13.3%)Accepted-Finance | L3 | Accepted-Finance OK | |
| 4 | L4₹36.0 L+₹4.8 L (15.5%)Accepted-Finance BARIYAWAN BARIYAWAN BARIYAWAN BARIYAWAN AMBEDKAR NAGAR UTTAR PRADESH 224210 | AMBEDKAR NAGAR | UTTAR PRADESH | 224210 | L4 | Accepted-Finance OK | |
| 5 | L5₹37.1 L+₹6.0 L (19.3%)Accepted-Finance | L5 | Accepted-Finance OK |
Tender Value
₹44.4 L
EMD Value
₹88,740
Closing Date
11 Jul 2025, 6:00 pmClosed
MAJ MANISH E WASNIK
GE (CENTRAL) DELHI CANTT-10
GE/TOKEN-17/2025-26
2025_MES_714477_1
GE/TOKEN-17/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE (CENTRAL) DELHI CANTT-10
AS PER NIT
9 documents required · 9 mandatory
₹500
Yes
GE (CENTRAL) DELHI CANTT-10
₹88,740
Yes
17 Jul 2025
14 Jun 2025
14 Jul 2025
14 Jun 2025
11 Jul 2025
28 Jun 2025
Amount
Demolition of cement concrete (un-reinforced) in any floor n.exc 15cm thickness ( below or above ground level ) not otherwise specially provided including removal of rubbish out side complex (MOD land), complete all as specified.
M & L for 25 mm thick cement concrete 1:2:4 type B-0 (using 12.50mm graded stone aggregate) as in sub base of tiles, surface even and rough without using extra cement, complete all as specified.
M&L for 75 mm thick cement concrete 1:3:6 type C2 (using 20mm graded stone aggregate). Plinth protection laid to a slope of 1 in 24 in alternate basis system.Surfaces even and smooth without using extra cement Each bay shall not exceed 3m in length, 12mm wide & 75mm deep joint shall be formed between the bays which shall be filled with Mastic filling to full depth comprising a mixture of 1 part of heator hot blow bitumen 85/25 portion and two parts of heated badrapur sand (by volume) complete all as specified and directed.
Demolition of brick work built in cement mortar in any description and position, complete all as specified.
M&L for brick work with sub class 'B' brick straight or curved on plan exc 6 metre mean radius with old size bricks, built in cement mortar 1:6, complete all as specified.
All as per item no 11 before but except bricks
M&L for brick work with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls with old size bricks, built in cement mortar 1:4, complete all as specified.
M&L for cement concrete 1:2:4 type B1(using 20mm graded stone aggregate) as in blocks for hold fast, coping, benching etc. including weathering, slightly rounded or chamfered angles or throating including form work to concrete surfaces, complete all as specified.
Taking down cement plaster of any description and in any position of brick or stone wall/concrete surfaces on walls ,ceiling etc including raking out joints ,hacking for key scrubbing down with water etc & prepared to receive new plaster complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar on fair faces of brick work or concrete surfaces , applied in two layers ie. Ist layer of 10 mm thick rendering in cement mortar (1:6 ) and 2nd ( top ) layer of 5 mm thick rendering in cement mortar (1:4 ) mixed with WPC finished even and fair etc complete all as specified and directed.(Note:- WPC shall be measured and paid seperately.)
M&L rendering 10 mm thick in CM 1:6 on internal brick/concrete wall surfaces of any description, and finishing the surfaces even and fair without using extra cement complete all as specified and directed .
Supply only integral water proofing admixture of approved quality.
M&L for rendering 5 mm thick in Cement Mortar (1:3) on ceiling finished even and fair without using extra cement complete all as specified and directed.
M&L complete removal of existing treatment of old surface of ceiling and applying three coat of white wash on ceiling complete all as specified and directed.
M&L prepration on new plastered surfaces of ceiling and applying three coat of white wash on ceiling complete all as specified and directed.
M&L for preparation of the newly plastered surfaces of walls applying wall care putty of 1 mm thickness over plastered surface to prepare the surface even and smooth to receive primer and applying one coat primer & two or more coats Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification.
M&L for preparation of old decorated surface (plastered or unplastered) of walls by complete removal of existing treatment by mechanical grinder and applying cement base wall care putty of 1 mm thickness over plastered surface to prepare the surface even and smooth to receive primer and applying one coat primer & two or more coats Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification.
Taking down chowkats or frames n.exc 1.5 sqm each with shutters (without taking off shutters from frames), complete all as specified.
Taking down chowkats or frames exc. 1.5 Sqm and n.exc 4 Sqm each with shutters (without taking off shutters from frames ), complete all as specified.
S&F Factory Made single extruded WPC (Wood Polymer Composite) Solid door/window/Ceosetory windows & other frames/ chowkat of size 45 x 70 mm comprising of virgin PVC polymer of K value 50-60 (Suspension Grade), calcium carbonate and natural fibers( wood powder/ rice husk/ wheat husk) and nontoxic additives ( max toxicityindex of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face & 1100 N Edge), min compressive strength of 58N/sqmm and resistance to flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed with MS Holdfast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engr in charge. Note: -For WPC solid door/windows frames, minus 5mm tolerance in dimension i.e., depth and width of profile dimension on plus side shall be acceptable but no extra payment on this account shall be made”.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and nontoxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of EngineerIn- Charge. (Note: stainless steel butt hinges shall be paid separately under relevant item).
S&F 5.5 mm thick toughened glass in square exc 0.5 sq. m in each pane each complete all as specified.
S&F mild steel work as in hold fast 25x3mm flat iron and similar articles conforming to Fe-410-0, complete all as specified.
Dismantling boarding any description (board/plywood) fixed in any position with screw, complete all as specified
S&F Factory Made 18mm thick 100% Solid WPC ( Wood polymer Composite ) Laminated Board of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbm having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compissive of 50 N/mm2 , Modulus of elasticity 850N/mm2 and esistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter and fixinng stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws. All as per direction of Engineer -In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company : For WC/Bathroom/Toilet/Kitchen and Cabinets.
S&F 125 mm long (size) butt hinges, medium weight, cold rolled mild steel, complete all as specified.
S&F 75 mm long L Bihari concealed type hydrauilc hinges incl stainless screw complete all as specified.
S&F Stainless Steel Cylindrical lock complete all as specified and directed.
S&F 200mm long stainless steel barrel tower bolt of extruded section, complete all as specified.
S&F stainless steel AISI 304 grade floor door stopper with hard drawn steel spring 140mm long complete all as specified and directed.
S&F 100mm long, extruded fancy type SS handle for kitchen cup boards shutters, cabinets, crocery shelf drawers fixed with nuts , screw and washer of mild steel bright finished , complte all as specified.
S&F ball catches with 8mm dia steel ball and brass body and striking plate including letting in and fixed, complete all as specified.
S&F Door closer hydrau lically regulated,(Aluminium extruded section body) designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified
Dismantling of stone slabs and tiles of any description or thickness in floors, wall, aprons etc laid, bedded and pointed in any mortar, all as specified.
S & F for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 all as specified and as directed.
M&L for Glazed ceramic tiles in vertical surface 600x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar (1:3) complete all as specified and as directed.
M&L for double charged vitrified Ceramic tiles light shade 8 to 9 mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm of size (600mm X 1200mm), in floors etc. set and jointed with epoxy tile grout to match the colour of tiles using 3mm thick PVC spacers complete including 15mm thick screed bed in cement mortar 1:4, complete all as specified and directed.
All as per item No 38 above but as skirting over and including 10mm thick rendering in CM 1:3.
M&L for 18-20mm thick coloured granite stone work Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to matchwith shade of granite.
S&F 20 mm thick interlock pattern rubber flooring in Gym area Made from 100% natural rubber, rubber flooring is made from natural, renewable resources and is resistant to extreme temperatures. Installed on any surfacewith sutable adhesive complete all as specified and as directed.
Taking up or down 15 mm dia GI tubing and connections complete all as specified.
Taking up or down 20 mm dia GI tubing and connections including cleaning for re-fixing, complete all as specified.
Supplying and laying of CPVC 20mm OD pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified complete with fitting as required.
Supplying and laying of CPVC 25 mm OD pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified complete with fitting as required.
Dismantling of cast iron pipe of any dia (soil/waste/vent) with fittings etc fixed to walls,ceiling, on floors & from trenches if required including taking out any type of joints complete all as specified.
S & F 75 mm dia (bore of pipe) cast iron (sand cast) soil, waste, vent pipe in any length with or without ears with cement joint fixed to walls, complete all as specified.
S & F 100 mm dia (bore of pipe) cast iron (sand cast) soil, waste, vent pipe in any length with or without ears with cement joint fixed to walls, complete all as specified.
S&F 110mm dia (bore of pipe) cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with cement joints, complete all as specified.
S&F 75mm dia (bore of pipe) cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with cement joints, complete all as specified.
S&F 110mm dia (bore of pipe) cast iron Tee (any radius), diminishing pieces or tapers (larger bore measured) with cement joints, complete all as specified.
S&F 75mm dia (bore of pipe) cast iron Tee door with ovel access (any radius), diminishing pieces or tapers (larger bore measured) with cement joints, complete all as specified.
All as per item 92 above but fitted with oval access door for 110mm dia (bore of pipe).
All as per item 93 above but fitted with oval access door for 75 mm dia (bore of pipe)
S&F in repair cast iron floor trap square type with Cockroch Proofing CP grating with or without hole including provision of jointing to waste pipes in run lead joint dia of outlet 75 mm, complete all as specified.
S&F in repair Salt Glazed Stone Ware (SGSW) gully traps square or round mouthed type size 150x150mm including excavation/earth work, bed concrete, surrounding concrete and CI grating, complete all as specified.
S&F in repair Vitreous china premium/ 1st qualitywash down water closet wall hung EWC white/ ivory/off white (closedpattern incl all necessary accessorieslike rag bolts/ gel gasket etc. (excluding flushing cistern & flushpipe) complete in all respect all as specified. Make - Jaquar Cat No- CNS-WHT-959NUF/ or equvalent to Roca Cat No RS346640460 and Kohler cat No K-32427IN-0
S&F in repair concealed type Wall Hung flushing Cistern with Drainage L-Bend Pipe with Gasket & Installation Kit (Suitable for EWC). Make: Jaquar Cat No- JCS-WHT-2431FS / or equvalent to Roca Cat No RE890010100 and Kohler cat No K-26353IN-M-NA.
S&F in repair CONTROL PLATE OPAL for flushing CISTERN.Make: Jaquar Cat No- JCP-CHR-852415 or equvalent to Roca cat No-RA890189000 and Kohler Cat No -K-75890IN-M-CP.
S&F in repair Vitreous China Urinal, full stall type,white (excluding flushing cistern, flush pipe and waste pipe)(Back Inlet) With Fixing Accessories, Size: 385x325x635 mm.Make: Jaquar Cat No- URS-WHT-13253N / or equvalent to Roca Cat No RS3590J300C and Kohler cat No K-20713IN-ER-0
S&F in repair Urinal spreader fixing with 15 mm dia pipe complete all as specified and as directed.
S&F 8 mm thick Curved shaped urinal partition with frosted glass of Size Height: 900 Width: 450 Fixed on wall with the help of SS grade 316 brackets. Make Jaquar JSE-CHR-110UC450X or equvalent to Cera Cat No. : S4090104 Hindware Cat No-SU81OSC(C)-STD-CR
S & F in repair Brass CP health faucet hand shower type with 8mm dia 1.0 Meter long Flexible Tube and Wall Hook with N.R.V screwed for iron pipe fancy type long body all as specified and directed.Make Jaquar ALD-CHR-577 or equvalent to Roca cat No-RF9061A1 and Kohler Cat No -K-77364IN-CP
Supply & fix in repair PVC connection pipe of 15mm x 600mm long with 2 Nos brass check nuts with washers, complete all as specified.
Supply & fix in repair CP connection pipe of 15mm x 600mm long with 2 Nos brass check nuts with washers, complete all as specified.
S&F fancy type brass chromium plated toilet paper holder, complete all as specified.Make: CERA cat part no.F5004110, Prayag-BA38, Somany 27213033091 or equivalent.
S&F in repair fancy type brass chromium plated soap dish, complete all as specified.Make: CERA cat part no.F5004106, Prayag-BA15, Somany 27213033051 or equivalent.
S&F in repair SS cachorach trap grating 125mm dia, complete all as specified.
S&F in repairs vitreous chinaware coloured Table Top Basin wash hand basin of size 520x360 complete including , CP Waste coupling ,waste pipe ,complete fixing arrangement and cutting for and pinning in walls & making good complete all as specifed and directed by Engr in charge. Make: Jaquar Cat No- FLS-WHT-5931 or equvalent to Roca Cat No RS3270B8000 and Kohler cat No-K-25318IN-0
S&F in repair fancy type 15mm dia brass chromium plated quarter turn basin mixer with braided hose for mixing hot and cold water screwed down for iron pipe and fixed to WHB complete all as specified.Jaquar Cat No- COP-CHR-001BPM or equvalent to Roca Cat No RT5A349EC00 and Kohler cat No-K-27485IN-4-CP
S&F in repair fancy type chromium plated quarter turn brass angle valve type suitable for 15mm bore pipe complete all as specified.Make: Jaquar FLR 15053PM, CERA F1001201, Hindware F570043”
S & F in repair fancy type sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with CP brackrt gaurd and railling 60 cm long complete all as specified.
S&F in repair fancy type glass corner 300mm radius of 10mm thick toughned glass with CP railing fixed with screws fancy type complete all as specified .
S&F in repair fancy type glass corner 250mm radius of 10mm thick toughned glass with CP railing fixed with screws fancy type complete all as specified .
S&F stainless steel of AE - SI 316 grade tubular towel ring including apair of CP brass bracket complete all as specified.Make: Jaquar AQN-CHR-7721, or equvalent to Kholer cat No- K-5631IN-CP, Roca cat No- RA816070172.
S&F in repairs Two Way Bib Cock quarter turn screwed down, screwed for iron pipe, 15mm dia, fancy type, cast copper alloy, chromium plated long body with flange complete all as specified.Make: Jaquar ARI-CHR-39041, or equvalent to Kholer cat No- K-25432IN-4-CP, Roca cat No- RT5A9325CA1.
S&F in repair 1000 ltr capacity rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position with 20mm Ball brass valves,high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule Minimum wt 20mm-210grm and s&f in repair 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed incl Dismantling of PVC water tanks of exc 500 litres and n.exc 1000 litres capacity of any condition or type incl complete all as specified and directed.
S&F in repairs of 25mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed
Cutting shrubs, wild growth, plants not exc 30 cm girth grown on permanent structures and removing same from roots and stopping the recurrence by injecting herbicide Glyphosphate 4+ solution (04 % concentrate) into plant root to eliminate further growth. Application shall be as per manufacturer intructions. The disturbed area shall be repaired with PCC (1:2:4) Type B0 mix and surface finished even and smooth in cm 1:4 incl applying two coats of matching finish of adjacent area. Minimum plant in each block is 10 Numbers.
Dismantling of brick tiles or terracing tiles single layer on roof and removing the rubbish outside complex (MOD land),incl removal of vagitation if any complete all as specified.
Demolition of mud in roof, any thickness, including mud plastering and mud phuska under brick tiles at any situation and height, complete all as specified.
Roughening surfaces of old concretefloor by picking, sweeping clean andwashing down with water to removedust, etc
M &L for Brushing neat cement slurry with 3 Kg of cement per square metre complete all as specified and directed .
M&L for cement concrete 1:2:4 type B1 (using 12.5mm graded stone aggregate) on roof padding surface finished even and smooth without using extra cement complete all as spd & directed.
M&L for rendering 10mm thick on top of roof concrete in cement mortar 1:4 with water proofing compound at the rate of 3% by weight of cement to have a smooth surface for laying of water proofing membrane. Note: Water proofing compound will be measured and paid seprately.
M&L for APP based polymeric membrane plain finish minimum weighting 3 kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt not less than 150 gms/sqm) over one coat of 85/25 bitumen @1.2 kg/sqm and paste the membrane with torching method and again apply a coat of 85/25 bitumen @ 1.2 kg/sqm at overlapping joints. Notes itmes ser No 87 : (a) The work shall be executed through authorised applicator of manufacturer only. (b) Authrised Applicator shall be approved by GE before starting of work. (c) All materials shall be procured directly form manufacturer. The purchase voucher shall be produced to the Engineer-in-Charge for his verification of material. Engineer-in-Charge shall deface the original purchase vouchers. (d) MOU with authorized applicator will be submitted by contractor immediately after placing of work order. (d) A guarantee amount of 5% of contract of work done for item Nos 87 of BOQ will be retained for 5 years of the completion of work.
S&F for Heat Resistant Terrace Tiles (300 mm x 300 mm x 9 to 10 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and set and jointed with epoxy tile grout to match the colour of tiles using 3mm thick PVC spacers complete including providing skirting along the parapet walls of height as directed in the same manner including 15 mm thick backing coat in cement mortar 1:4, complete all as specified & directed.
M & L Cement concrete 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in roof kerbs or mud stops etc including weathering slightly rounded or chamfered edges, finished even and smooth without using extra cement complete all as specified.
M&L for followings :- (i) Removing plaster & finishes all around the coloumns, slabs & beams (on all four sidescription of column to full height , three sidescription of beam to entire span & bottom of slab to area as directed) (ii) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible) (iii) Removal of cover concrete with under cutting of up to a depth of 20mm beyond reinforcement around full circumference & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed) (iv) Cleaning exposed concrete substrate by using water jet. (v) Removing visible rust along the length of reinforcement using hand tools as approved. Supply & applying of rust removing chemical to remove rust from existing reinforcements. (The Engr-in-charge may order sand blasting if rust is visible) (vi) Any other work as directed by Engr-in-charge to present clean surface for determination of type of repair to be carried out complete all as specified and directed.
M&L for providing rust proof /anti corrosive treatment to bars :- (i) cleaning of all exposed bars (new & old) alround (ii) Apply a single coat of Alkaline rust converting primer on alround bars new & old as recommended by the manufactuer (iii) Apply two coats of Epoxy phenolic anti corrosive protective coat on bars alround new & old as recommended by the manufactuer. Note : Anti corrosive treatment shall be continuous espcially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of re bars (those towards the concrete substrate) should not be left without coating.
M&L for providing PMM (Polymer modified cementitious mortar) :- (i) Dry sub strate surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible.(In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) of 25 mm thickness. Note : Application of PMM shall be preferably be in coats of appx 10mm thickness. PMM work shall be executed in fairely rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use. (iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufactuer complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for parapet railing, balconies, metre rooms shaft area any description complete as specified and directed upto six storey height..
M&L for Preparation of new steel and iron surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of redoxide primer, complete all as specified.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 for hand grip in balcony railing and roof terrace or grills complete all as specified and as directed.
S&F 20 mm Ball brass valves,high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed. Minimum wt 15 mm -142grm , 20mm-210grm ,25mm -455grm,40mm-690grm complete all as specified and directed.
S&F of 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed complete to walls, ceilings or in floors with suitable clamps/bracket including taking down old PVC/CI pipes and necessary cutting through RCC roof and brick work etc (above six storey height) and making good all as specified.
S&F of 110 mm dia PVC (SWR) bends any radius with solvent joints, complete all as specified.
S&F powder coated aluminium Door seal not less than 1.00 mtr long with fine fibres suitable for fixing in doors.
Removing building materials etc.to a distance of 5.00km beyond the land included in the rates, including loading, unloading and stacking at the destination.
M&L for preparation of newly plastered surfaces of walls and providing and applying putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified as directed by Engr-in-charge.
M&L for preparation of old decorated plastered surfaces of walls, complete removal of existing treatment by rubbing , brooming down, washing with water etc and providing and applying plaster of Paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified as directed by Engr-in-charge.
S&F factory made uPVC any colour fixed glazed window/ventilator made of ( small series) frame 47 x 50mm mullion 47 x 68mm both having wall thickness of 1.9 + 0.20mm and single glazing bead of appropriate dimension ( Area upto 0.75 sqmtr) comprising of uPVC multichambered frame and mullion (wherevr required) extruded profile duly reinforced with 1.60 +0.20mm thick galvanised mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropraiate dimension, EPDM gasket, G.I. fasteners 100 x 8mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless screw etc.Profile of frame shall be miterd cut and fusion welded at all corners, mullion (if reqd) shall be also fusion welded including 5mm thick toughened glass drilling holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of reqd size and approval quality, all complete as per approved drg and direction of Engr in charge. Note: For uPVC frame, sash and mullion extruded profiles ,minus 5% tolerance in dimension i.e depth and width of profile dimension in higher side shall be acceptable but no extra payment on this account shall be made
S&F factory made uPVC any colour three track three panels sliding window with flyproof S.S. wiremesh ( Two nos. glazed & one no. wiremesh panels ) upto 1.50m ht made of big series frame 116 x 45mm & sash 46 x 62mm both having wall thickness of 2.3 + 0.20mm and single glazing bead/ double glazing beading of appropriate dimension ( Area of window upto 1.50 sqmtr) comprising of uPVC multichambered frame and mullion (wherevr required) extruded profile duly reinforced with 1.60 +0.20mm thick galvanised mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropraiate dimension, EPDM gasket, G.I. fasteners 100 x 8mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless screw etc.Profile of frame & sash shall be miterd cut and fusion welded at all corners, mullion (if reqd) shall be also fusion welded including 5mm thick toughened glass and SS wire mesh fixed and drilling holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of reqd size and approval quality, all complete as per approved drg and direction of Engr in charge. Note: For uPVC frame, sash and mullion extruded profiles ,minus 5% tolerance in dimension i.e depth and width of profile dimension in higher side shall be acceptable but no extra payment on this account shall be made.
S&F in repair Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specied and as directed including dismantling.
S&F in repair Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge / roof covering/ cladding to wall, fixed with self tapping screws as specified all as specified and as directed including dismantling.
M&L cutting and chases pinning in concrete block/ Brick work making good to facings where required and pointing in cement morter 1:3 and cutting chases for concealed water tubing or conduit wiring,etc and making good cutting not exc 10 cm girth.
S & F for 75 mm dia (bore of pipe) cast iron vent cowls complete all as specified.
S & F for 100 mm dia (bore of pipe) cast iron vent cowls complete all as specified.
Cleaning and drying the brick surfaces, and make it dust free. Prewetting the surface with water before application of Dampblock 2k, and then applying a skim coat of polymerised putty and after drying 2 coats of Smartcare dumpblock 2K @1.5 Kg/ Sqm. (Application of plaster shall be measured and paid in appropriate item).
Material & Labour for providing and fixing stainless steel (Grade 304) grill made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the grill with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangementcomplete all as specified and directed.
S&F in Repair False ceiling with GRG (Glass fiber Reinforced Gypsum) tile with semi perforated 12 mm thick micro tegular edged of size 595 x 595 mm of approved textures design and patterns having moisture content less than 2%, humidity resistance of 99%, NRCO.50 to 0.75 as per IS 8225:1987. Noncombustible as per BS 476(Part 4)-1970 and light reflectance of 85% (minimum) to be laid in the horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33 mm thick (galvanized @120 gms per Sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000 mm, cross -T of size 15 x 32 mm of length 1200 mm and secondary intermediate cross - T of size 15 x 32 mm of length 600 mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanized mild steel items (galvanized @80 grams per Sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod up to 1000 mm length and L-shaped level adjuster of size 85x25x2 mm. Galvanized iron perimeter wall angle of size 24 x 24 x 0.40 mm of length 3000 mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450 mm c/c and 40 mm long dry wall wood screws., complete all as spd by any. in. Change.
Providing and fixing 6mm thick Suede Finish Greenlam, or equivalent exterior grade Clad (High Pressure Laminates) made up of 1300mm x 3050mm in size and conforming to EN 438-6:2016 standard, EDF Grade. Exterior CLAD HPL should be made under high pressure, using thermosetting Phenolic resin treated kraft layers, Amino plastic resin treated Exclusive & UV conforming Exterior Grade Decorative paper on both sides and UV protection layer above the décor papers on both sides. Clad should be resistant to wet conditions and meets permissible increase on mass, have density >1.35 gm /cm3, UV resistance of a minimum of 4 on a grey scale rating after 1500 hours, Resistance to artificial weathering including light fastness of a minimum rating of 4 (after 650 MJ/m2 radiant exposure). The product must conform to European Fire-Retardant norms of Bs1d0 when classified in accordance with EN 13501-1. The Fire-Retardant Additive must be Halogen free to protect the environment. HPL must be a green product conforming to GRIHA, GreenPro and Green Guard Gold certification and meet Anti-bacterial and Anti-termite property under JIS Z2801 (The manufacturer should provide 12 years warranty on manufacturing related defects). Finish and colour of compact laminates should be finalized under direction of Engineer –in-charge.Clad should be installed on Aluminium tubular substructure in the size of 50mm x 25/50mm or as per site requirement fixed at a maximum centre-to-centre distance of 400mm to 600mm with the help of 5mm dia colour matching rivets with sliding holes and fixed holes on the HPL. The aluminium tubular substructure should be fixed on wall with the help of dead load bearing brackets and wind load bracket by 10mm fastener. Wind load bracket will have vertical slot & dead load bracket will have in horizontal slot & maintain 6mm both horizontal and vertical gap between two installed clad panels. Shade/design of clad should be finalized under direction of Engineer –in-charge.
M&L cement concrete 1:4:8 type D- 2 (40mm graded stone aggregate) as in sub base, hard standing of 75 mm thick, complete all as specified.
M&L for rubber moulded Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors over 20 mm thick screed bed in cement morter (1:6) complete all as directed.
Material and labour Machine pressed precast concrete rubber moulded interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed.
M&L Hardcore of broken stone or boulders guage n.exc 63mm deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface
Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in soft/loose soil complete all as specified.
Returning filling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil complete all as specified.
Removing excavated materials to a distance n.exc 50 m and depositing where directed.
M&L PCC 1 : 4 : 8 type D2 using 40mm graded stone aggregates as in foundation of manholes, posts etc complete all as specified.
M&L for PCC 1 : 2 : 4 type B2 using 20mm graded aggregates as in surfaces channels and drains complete all as specified.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement incl forms, moulds, mitred/stoped ends etc complete all as specified.
S&F DWCPE(SN8) 150mm dia (Internal Dia) pipes,snap fit coupler and rubber ring incl testing and laid and properly jointed laid in trenches to a level on concrete bed complete all as specified.
M&L for Brick work sub class ‘B’ bricks state or curved on plan built in cement mortar 1:4 using old size bricks complete all as specified and directed.
M&L for precast factory made manhole cover, area of each cover n.exc 0.60 Sqm, 100mm thick with SFRC concreting including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 100mm internal dia pipe, complete all as specified.
M&L for rendering 15mm thick on top of roof concrete in cement mortar 1:4 with water proofing compound at the rate of 3% by weight of cement to have a smooth surface for laying of water proofing membrane. Note: Water proofing compound will be measured and paid seprately.
Demolition and breaking up drain pipes (glazed stone ware, AC or reinforced concrete),150 mm dia pipe of any description and in any position set and jointed in cement mortar complete all as specified and directed by Engr-in-Charge
Demolition of brick work built in cement mortar in any description and position, complete all as specified.
Demolition of cement concrete (un-reinforced) in any floor n.exc 15cm thickness ( below or above ground level ) not otherwise specially provided including removal of rubbish out side complex (MOD land), complete all as specified.
M&L for brick work with sub class 'B' brick straight or curved on plan exc 6 metre mean radius with old size bricks, built in cement mortar 1:6, complete all as specified.
M&L for rendering 15mm thick in cement mortar (1:4) on concrete/ fair surfaces of block masonry, finished even and smooth without using extra cement with and including mixing water proofing compound as per manufacturers instructions complete all as specified and as directed by Engr-in-Charge. Water proofing compound shall be measured and paid for separately under appropriate item of Sch "A' as supply only on requirement basis
Taking down carefully copper/aluminium point wiring (light/fan/ socket/power) complete from the wall by cutting/ chasing including fittings and fixtures such as switches, ceiling roses, pendants holder, regulators, sockets,light fittings etc for credit and making good the disturbed surfaces of wall, floor etc complete all as specified and directed.
Taking down carefully sub main wiring of any description.
M & L for Point wiring (concealed) complete with 1.5 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade with multi stranded copper conductor drawn through in and including non metallic medium grade rigid PVC conduit, ISI marked not less than 20 mm dia including all accessories concealed in wall by cutting chases and including provision of 1.5 sqmm PVC insulated unsheathed copper cable FRLS as earth continuty conductor including fabricated branded modular metal flush box duly make embossed, concealed in walls and making the adjacent surfaces smooth through POP work & painting as per site requirement and with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc, complete all as specified and as directed for the followings:-
One light /Ceiling fan/exhaust fan point controlled by one, one way switch .
One light point controlled by two Nos two way switches
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent but not below the switch board of light point.
(e) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
All as per item No.139 herein before but with 4 Sqmm cable for one 3 pin 15 Amp switch socket outlet and using 4 sqmm PVC single core copper conductor cable multistranded as earth wire complete all as specified and directed. Notes itmes ser No 139 : (a) The work shall be executed through authorised applicator of manufacturer only. (b) Authrised Applicator shall be approved by GE before starting of work. (c) All materials shall be procured directly form manufacturer. The purchase voucher shall be produced to the Engineer-in-Charge for his verification of material. Engineer-in-Charge shall deface the original purchase vouchers. (d) MOU with authorized applicator will be submitted by contractor immediately after placing of work order. (d) A guarantee amount of 5% of contract of work done for item Nos 139 of BOQ will be retained for 5 years of the completion of work.
M&L switch Modular type 6 Amps SP 230V AC complete all as specified and directed.
M&L switch modular type 6 amp two way complete all as specified and directed.
M&L Modular socket outlet 5 pin 6 Amp socket 2 module complete all as specified and directed.
M&L switch Modular type 16 Amps SP 230V AC complete all as specified and directed.
M&L Modular socket outlet 5 pin 6/16 Amp universal socket 2 module complete all as specified and directed.
S&F ceiling rose, PVC / Polycarbonate, isolated body with three terminals.
S&F of modular AC Box consisting of 20 Amp multipower socket including MCB SP of capacity 25 Amp mini MCB, ‘C’ curve, single phase 240 V, AC including modular box, frame, cover plate including plug top with indicator complete all as specified and directed .
Supply in replacement and fix Slim LED T-5 batten luminaire surface mounted with aluminium extruded housing & polycarbonate diffuser, 4 feet system wattage of 20 Watts with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 20%, colour temperature - 6500K, surge protection 2.5 KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 Degree C, system efficacy at luminaire level >120 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed by Engr-in-charge.
S&F in replacement of Slim LED T-5 batten luminaire surface mounted with aluminium extruded housing & polycarbonate diffuser 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 25000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficacy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
S&F in replacement of decorative type wall mounted luminaire (comet type) with unbreakable poly carbonate materials with 1x14 watt LED bulb B22 Base having lumen efficiency 100lm/w, 6500K complete all as directed.
S&F in replacement of LED 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 100 lm/W with a life class of 25000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<20%, CRI>80, Color Temperature-6500K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed complete all as specified and directed by Engr-in-charge.
S&F LED 2 X 2 ft backlite surface mounted fitting 36/40 Watts with Metallic CRCA powder coated body with high efficiency opal/PMMA diffuser with system efficacy > 100 lm/W, CRI>80, color temperature >5700k, IP 20, Power factor<0.95, THD<10%, 25000 burning hours , Ambient temperature 0 to 500 DegC, Driver should meet IEC complaint for safety, with voltage variation range of 150-270 V and surge protection of 2.5 KV including necessary fixing arrangementsfixed complete all as specified and directed.
M&L for angle Lamp holder with metalic ring, pvc/ polycarbonate type back plate with LED bulb 09 watt, 900 lumens out put, 6500K suitable for B-22 base all as per directed
S&F 35 W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie should not less than 100lm/W. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:65 protected. It has an electronic driver complaint to IEC safety standards with a power factor>.0.95, voltage variation range 120-270V, THD<20%, High and low voltage protection along with a surge protection of 4 KV internal including provision of sutable dia GI light grade pipe1.2 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed.
Supply & fix LED bollard lights ,10W ,single phase with decorative LED bollard lights luminaire with diffuser and painted spun aluminium deflector pre wired and provision of twin core flexible wire,copper conductor of 0.5 Sqmm from light fitting to loop in box complete and M&L for making foundation for bollard light of size 250mmx250mmx400mm and plastering & painting the surface of foundation complete all as specified and direcetd by Engineer-in-Charge.
S & F water heater storage type (Geyser) vertical type ABS body maximum operating pressure 8 bar with safety valve nickle coated element with suitable size of fastner and incl provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection, having adjustable knob for temperature control and inner tank should be glass line coated complete all as specified of capacity 25 ltr having heating element 2 KW and not less than 5 star rating.
Supply and fixing ceiling fans complete three blade, Robust and reliable inverter motor (brush less DC Motor) powered by ECM technology, BEE 5 star rating for energy saving, rated Air delivery >220cum/min, AC single phase 230/240 V of size 1200 mm sweep including making connection with three core flexible copper cable pvc insulated of suitable length, down rods, Remote of Ceiling fan and accessories complete.
Supply and fixing of wall mounted fan 400 mm sweep, aerodynamic designed, air delivery ≥ 70 CMM, thermal over load protected motor, 3 blade white colour, 230 volts, 50 Hz, 1300 RPM with 90 degree oscillation and having speed & oscillation control by two pull cords system complete all as specified
Supply and fixing Ventilating Fan 250 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm and making necessary opening in brick wall/window as per site condition complete all as specified and as directed.
S&F factory made epoxy powder coated Distribution board (MCCB DB) TPN 4 way vertical type, IP - 43 Protection made out of min 1.6 mm thick CRCA sheet, fabricated, metal double door fixed to wall and suitable for universal mounting and including 200 Amps rated copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removeable gland plated with knockouts and suitable for TPN MCCB 125/160 Amps as incomer and 12 SP or 04 Nos TP MCBS as outgoing complete all as specified.
Supply & Fix in replacement MCCB 160 Amp, 16 KA, 415 Volts 4 pole with copper lugs complete all as specified and directed by Engineer-in-Charge.
S&F MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete Note:-(i) MCB shall be measured & paid separately (ii) make of DBs & MCB should be same
S&F RCBO Double Pole 63 Amps , 30mA , 240 volts 10 KA 50 HZ complete.
S&F MCB SPN 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
S&F MCB SP 6 - 32 Amps 240 volts 10 KA 50 HZ 'B' curve complete.
M&L for Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS unsheathed cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS unsheathed cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls all as specified and as directed. Note:- (1) Two runs of cable, one run of earth continuity conductor and one run of PVC conduit shall be measured as unit length. (2) The damaged surfaces to be made good with plastering will be carried out by contractor and cost of the same deem to be included in the quoted rates. Nothing extra in this account will be admissible.
M&L for Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS unsheathed cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS unsheathed cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls all as specified and as directed. Note:- (1) Two runs of cable, one run of earth continuity conductor and one run of PVC conduit shall be measured as unit length. (2) The damaged surfaces to be made good with plastering will be carried out by contractor and cost of the same deem to be included in the quoted rates. Nothing extra in this account will be admissible.
M&L for Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS unsheathed cable 1100 volts grade, multistranded copper conductor cable with one run of 10 sqmm single core PVC insulated FRLS unsheathed cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls all as specified and as directed. Note:- (1) Two runs of cable, one run of earth continuity conductor and one run of PVC conduit shall be measured as unit length. (2) The damaged surfaces to be made good with plastering will be carried out by contractor and cost of the same deem to be included in the quoted rates. Nothing extra in this account will be admissible.
Dismantling and taking out old unserviceable Earthing and M&L earthing complete with GI electrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earth plate not less than 1.50 mtr below normal ground level connected to GI wire 4.0 mm as earthing lead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze drilled and screwed all as specified including excavation and earth work and disposal of surplus soil incl 15 mm GI tubing light grade and necessary fitting for protection of GI wire incl laying of alternate layer of charcoal dust and common salt PPC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MS angle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia GI pipe Medium grade for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed. Note:- Galvanised wire and protection light grade GI pipe upto 7.5 mtr shall be deemed to be in the rates.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc of size 4.0 mm thick galvanised wire with duly fixed on suitable size complete
M&L for fixing of suitable size of fan hook/ clamp made mild steel 6 mm thick in round shape fixing in 40mm GI pipe, load carrying capacity not less than 6 kg and necessary accessories as per site requirement complete all as specified and directed.
Supply and fix loop in /loop out box of suitable size PVC moulded terminal box with locking arrangement comprising of one 4 way conncetor all as specified and directed
Supply,laying PVC under ground XLPE insulated heavy duty electric cables armoured with aluminium conductor, 1100 volts grade, cross sectional area 6 sqmm 2 core laying in trenches, fixed along wall, through GI pipe under floor complete.
S&F for HDPE double wall corrugated pipes conforming to IS-14930 Part-II with IP Protection of IP-67 having outer dia 50 mm and inner dia of 32 mm with necessary couplers, bends etc for protection of LT cable all as specified and directed.
Excavation in trenches n.exc 0.45 m wide and n.exc 0.60 m depth for laying of LT cables etc. and getting out in hard/dense soil soil soil complete all as specified
Removal of excavation material not exc 50 Meter and depositing where directed at a level not exc. 1.5 M above the starting point complete all as specified and directed.
Schedule of Credit
POONAM ENTERPRISES (BID ID -3347453)
M/S MANINDER CONSTRUCTION CO. (BID ID -3346624)
m/s VK construction company (BID ID -3344972)
M/s SAAR ENGINEERS (BID ID -3347029)
DEEP BUILDER (BID ID -3345222)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .