Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 3 LSC 2ND FLOOR OPP ANNADLOK SOCIETY GATE NO 1 DDA MARKET MAYUR VIHAR PHASE 1 NEW DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹12.7 L
EMD Value
₹15,900
Closing Date
31 Jan 2026, 11:00 amClosed
GM(EXCV)NCL, NIGAHI PROJECT
OFFICE OF GENERAL MANAGER (EXCV)NIGAHI, PO-NIGAHI, DISTT-SINGRAULI (MP)
Annual Maintenance Contract for 05 Nos. 2Ton AC and 01 No. 5Tone AC Installation in 20/90 Bajrang and Matang Dragline at Nigahi Project for the period of 365 day ( one year)
2026_NCL_351089_1
NGH/EXCV/TENDERS/25-26/080
Open Limited
Excavation Department Work
Item Rate
365 days
NCL NIGAHI PROJECT
AS PER NIT
4 documents required · 4 mandatory
₹15,900
28 Jan 2026
12 Jan 2026
2 Feb 2026
12 Jan 2026
31 Jan 2026
13 Jan 2026
12 Jan 2026 - 19 Jan 2026
Scope of Work/Technical Specifications- Annual Maintenance Contract for OEM fitted Air Conditioners fitted in operator cabin and PCR units of 20/90 Bajrang and Matang Dragline at site at Nigahi Project for a period of one year. The details of the Air Conditioning System fitted in Matang Draglines are as follows: 1. Air conditioner fitted in Operator Cabin: 01 no. of 2 Ton 2. Air conditioner fitted in AC Electrical PCR: 01 no. of 2 Ton 3. Air conditioner fitted in DC Electrical PCR: 01 no. of 2 Ton The details of the Air Conditioning System fitted in Bajrang dragline are as follows: 1. Air conditioner fitted in Operator Cabin: 01 no. of 2 Ton 2. Air conditioner fitted in AC Electrical PCR: 01 no. of 5 Ton 3.Air conditioner fitted in DC Electrical PCR: 01 no. of 2 Ton Scope of work is as follows: 1. To carry out periodic / scheduled inspection and maintenance of entire system. Thorough inspection of all air conditioning systems by team consisting of system specialist with helpers in line with checklist and OEM/OPM recommendations 2. Attend and rectify the minor breakdown / repair, if any, within 24 hours of reporting the problem and rectify the major breakdowns within 72 hours of reporting. 3. Periodic inspection and maintenance for Air Conditioner system, Refrigerant Gas, Chemical cleaner and Compressor oil to be provided by contractor/AMC holder during AMC period. 4. Any leakage in air conditioner will be checked in every point by soap solution. 5. Vacuum formation in the system by means of vacuum pump. 6. Refrigerant charging (R410c, R407c) with the adjustment of high and low pressure cut offs. 7. Ensuring proper cooling within the PCR room, operator cabin. 8. Replacement of any defective / faulty parts of the Plant Air Conditioner on the machine. The necessary spare parts will be provided by NCL Nigahi departmentally except Refrigerant and Compressor oil, which has to be provided by contractor. 8. To assist in planning and procurement for maintenance and repair spare parts & stocking at our end. Maximum Likely numbers of workmen to be deployed for work per day is 05Nos.
Annual Charges for Annual Maintenance Contract for repair and maintenance of OEM fitted Air Conditioning System in Operator Cabin and PCR units of 20/90 Matang Dragline at Nigahi Project as per scope of work including labour charges, charges of Refrigerant, compressor oil, tools tackles, profit, transportation & any misc.charges at Nigahi Project, NCL.
Annual Charges for Annual Maintenance Contract for repair and maintenance of OEM fitted Air Conditioning System in Operator Cabin and PCR units of 20/90 Bajrang Dragline at Nigahi Project as per scope of work including labour charges, charges of Refrigerant, compressor oil, tools tackles, profit, transportation & any misc.charges at Nigahi Project, NCL.
Total impact of GST for the purpose of CTC
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 3.72 MB
ANNEXURESANDOTHERIMPORTENTDOCUMENT.pdf
Tender Documents • 0.28 MB
UNDERTAKINGASPERANNEXURE-II.pdf
Tender Documents • 0.08 MB
BOQ_363831.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .