| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹6.5 LAccepted-AOC | L-1 | Accepted-AOC Tender accepted due to the lowest tenderer | |
| 2 | L-2₹6.9 L+₹42,771.95 (6.57%)Rejected-Finance | L-2 | Rejected-Finance Not being L1 |
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
15 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Niwaru
AGE (I) Niwaru
AGE(I)/N-27 OF 2022-23 PROVN OF TOILET AND BATHROOM IN THE ARMY PRE-PRIMARY SCHOOL AT NIWARU MIL STN,JAIPUR AGE (I) NIWARU
2022_MES_559193_2
AGE(I)/N-27 of 2022-23
Open Tender
Civil Works
Item Rate
180 days
AGE (I) Niwaru
CLASS E
6 documents required · 6 mandatory
₹500
Yes
AGE (I) Niwaru
₹14,000
Yes
3 Jan 2023
30 Nov 2022
17 Dec 2022
30 Nov 2022
15 Dec 2022
1 Dec 2022
Amount
M&L for Surface excavation not exc. 30 cm deep and averging 15cm deep and getting out in soft/loose soil, complete all as specified and as directed by Engr-in-Charge.
M & L for hardcore(broken stones & boulders) of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed by Engr-in-Charge.
M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in plinth protection, 50mm thick finished even and smooth without using extra cement,complete all as specified and as directed by Engr-in-Charge.
Earth filling under floors including spreading, levelling, watering and well ramming in layers not exc 25cm thick. Note :- Soil obtained from excavation under item 1 here-in-before shall be used for filling, complete all as specified and as directed by Engr-in-Charge.
M & L for Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth foundation, or not exc 10 Sqm on plan & getting out in soft/loose soil ,complete all as specified and as directed by Engr-in-Charge.
Returning , filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm thick in hard/dense soil, complete all as specified and as directed by Engr-in-Charge.
Removing excavated material (soil) to a distance exc. 250 metre but not exc 500m and depositing, complete all as specified and as directed by Engr-in-Charge.
Removal of surplus excavated material to a distance not exc. 50 Mtr and depositing where directed at a level not exc. 1.5 Mtr above the starting point, complete all as specified and directed by Engineer-in-Charge
M&L for 75mm thick PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in sub base to floor finished fair and even, complete all as specified and as directed by Engr-in-Charge.
M & L for Cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate in foundation filling and mass concrete, complete all as specified and as directed by Engr-in-Charge.
Brick work with sub class 'B' bricks straight or curved on plan exc.6 metre mean radius built in Cement Mortar 1:6 in walls,complete all as specified and as directed by Engr-in-Charge.
Brick work with sub class 'B' bricks straight or curved on plan exc.6 metre mean radius built in Cement Mortar 1:4 in walls,complete all as specified and as directed by Engr-in-Charge.
Formwork to sides of concrete foundations, footings, base of columns, rafts and raft beams sides & soffits (if any) of foundation and plinth beams and similar work, vertical or to batter rough finished surfaces of concrete, complete all as specified and as directed by Engr-in-Charge.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) for flat srface of concrete, complete all as specified and as directed by Engr-in-Charge.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc, complete all as specified and as directed by Engr-in-Charge.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizintal or sloping and similar work exc 10cm but n exc 20cm wide for fair finished srfaces,complete all as specified and as directed by Engr-in-Charge.
Formwork to sides of pillars posts, struts, piers, columns and stanchions,complete all as specified and as directed by Engr-in-Charge.
M&L for Reinforced cement concrete (design mix) M-25 ( using 20mm graded crushed stone aggregate) in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc basement slabs, under reamed piles and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced cement concrete (design mix) M -25 ( using 20mm graded stone aggregate) as in columns, pillars, piers, posts & struts etc complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced cement concrete (design mix) M -25 ( using 20mm graded stone aggregate) as in lintels up to -1.5m clear span, seismic and other similar bands, lintel bands, plinth bands, roof bands and the like, complete all as specified and as directed by Engr-in-Charge.
M&L for Reinforced cement concrete (design mix) M -25( using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies deck slabs, and in shelves and the like complete all as specified and directed by Engineer-in-Charge.
S&F deformed or twisted mild steel bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips, complete all as specified and as directed by Engr-in-Charge.
S&F deformed or twisted mild steel bars 6 to 8 mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips, complete all as specified and as directed by Engr-in-Charge.
All as per item no No. 23 above but 6 to 8 mm dia in stirrups, spacers and binders, complete all as specified and as directed by Engr-in-Charge.
M&L for Rendering 10 mm thick on brick wall surfaces, in CM (1:6) and finished even and smooth surface without using extra cement, complete all as specified and as directed by Engr-in-Charge.
M&L Rendering 05 mm thick in CM 1:3 on ceiling surface finished fair and even, complete all as specified and as directed by Engr-in-Charge.
M&L Rendering 15mm thick in CM 1:4 on stone masnory surface or surface other than fair face of brick work wall, finished fair and even, complete all as specified and as directed by Engr-in-Charge.
M&L for Preparation of newly plastered surfaces of any description and treated with two coats of cement base paint of approved shade/tint over a coat of primer wall, complete all as specified and as directed by Engr-in-Charge.
M&L for Preparation of newly plastered surfaces of any description and treated with two coats of oil bound distemper of approved shade/tint over a coat of primer on wall, complete all as specified and as directed by Engr-in-Charge.
M&L for Preparation of newly plastered surfaces of any description and treated with two coats of oil bound distemper of approved shade/tint on ceillings, complete all as specified and as directed by Engr-in-Charge.
M&L for 30mm (average thickness) PCC 1:2:4 type B0 using 12.5mm graded stone aggregate as in floor and surfaces finished fair & even, complete all as specified and as directed by Engr-in-Charge.
M&L for screed bed or beding layer of cement mortar (1:6), 15mm thick for laying floor finishes, complete all as specified and as directed by Engr-in-Charge.
M&L for coloured Non Skid ceramic coloured tiles joint free 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and as directed by Engr-in-Charge.
M&L for coloured Glazed ceramic colored tiles size 300x200x7mm thick edge cut/joint free, on wall etc in the combination of light and dark shed concept. Set & jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick plaster in CM (1:4), complete all as specified and as directed by Engr-in-Charge.
The surface shall be painted with one coat of polymeric primer @ 0.30 Kg per sqm, conforming to IS : 3384, A layer of AOO based polymeric membrane, 3 mm thick (min), weighing not less than 3.5 Kg/m2 reinforced with polyster non woven fabric (weighing not less than 150 gm/sqm). Application of polymeric membrane shall be by torch application all as per manufacturer instructions. and finally applying one coat of bitumen @1.2 Kg/sqm on APP membrane before application on aluminium paint, complete all as specified and as directed by Engr-in-Charge.
S&F Figured glass, 4.0mm thick pin head type and glazing with oil putty in squares n exc 0.5 sq.m in each pane, complete all as specified and as directed by Engr-in-Charge.
S&F 28 thick "Rajshri" or equavalant as per PS Brand factory made PVC Supreme Door Shutter consisting of frame made ut of M.S. tubes of 19 guage thickness and size of 40mmx20mm for stiles, top and bottom rails having a coat of steel primers of approved make and maufacture. M.S frame covered with 4mm thick heat moulded "Rajshri" Prelam PVC 'C' Channel of size 28mm thickness, 75mm width out of which 60mm shall be flat and 15mm shall be tapered in 45 fdegree angle on either sides forming stiles, top and bottom rail and 100mm wide Rajshri Prelam PVC sheet out of which 100mm shall be flat and 15mm shall be tapered an additional of 5mm thick PVC sheet of 20mm width is to be stuck on the interior side of 'C' Channel using PVC solvent adhesive etc, complete all as specified & directed by Engr-in-Charge.
S&F Factory made Rajshri or equavalant as per PS Adjustable (PVC) Door frame Manufactured by M/S Rajshri of the size 65mm x 60mm with a walll thickness of 4mm, made out of exturated 4mm PVC foam sheet, meter cut at two corners and jointed with 2 Nos of 150mm lond brackets of 15 x15mm M.S Square tube. The two vertical door porfile are to be reinforced with 40 x 20mm M.S tube of 19 guage through out the frame. The door frame shall be fixed to the wall using 65/100mm long M.S Screw through the frame by using PVC fasters, complete all as specified & directed by Engr-in-Charge.
Soap dish brass CP ISI Mark, complete all as specified and directed by Engineer-in-Charge
S&F PVC (SWR) pipes 75 mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) pipes 110 mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors., complete all as specified and directed by Engineer-in-Charge.
S&F 75 mm PVC (SWR) bends any radius, complete all as specified and directed by Engineer-in-Charge.
S & F 110 mm PVC (SWR) bends any radius, complete all as specified and directed by Engineer-in-Charge.
S & F 75 mm PVC (SWR), junction single, (Single T) equal or unequal, complete all as specified and directed by Engineer-in-Charge.
S & F 110 mm PVC (SWR), junction single, (Single T) equal or unequal, complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) vent cowl of 110mm bore, complete all as specified and directed by Engineer-in-Charge.
M&L PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement, complete all as specified and directed by Engineer-in-Charge.
S&F stop valve 15mm, . copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions, complete all as specified and directed by Engineer-in-Charge.
S&F Stop valves 20 mm bore, . copper alloy screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and directed by Engineer-in-Charge.
M&L for PVC Nahani/ Floor Trap and squre in size of 100x 100mm including MS chromium plated grating 125mm dia of weight not less than 50gm for floor trap/ Nahani trap, complete all as specified and directed by Engineer-in-Charge.
M&L for new galvanised steel water tubing of 15 mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge.
M&L for new galvanised steel water tubing of 20 mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge.
S&F Rotational moulded polyethylene(Five Layer) water storage tanks 500 ltr (cylindrical vertical with closed top) hoisted and fixed in position, complete all as specified and directed by Engineer-in-Charge.
S&F Brass Ball valves 20 mm bore high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed, complete all as specified and directed by Engineer-in-Charge.
M&L for providing circular, raised platform of height 15 cm below the tank and base 10 cm more than the external dia of tank of PVC cylindrical water tank of capacity 500/1000 liters using PCC 1:3:6 type C1 using 20mm graded stone aggregate with smooth finish, complete all as specified and directed by Engineer-in-Charge
S&F PVC connection 15mm bore with 2 Nos PTMT nuts, 45 cm long fixed with one end to pillar tap & the other end to stop cock or iron pipe, complete all as specified and directed by Engineer-in-Charge
Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0, complete all as specified and directed by Engineer-in-Charge
S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and directed by Engineer-in-Charge
M&L for preparing of new untreated steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synethic enamel paint over one coat of red oxide, complete all as specified and directed by Engineer-in-Charge
M&L MS holdfast, hook and pintel hinges; large hasps and staples, clamps; hooks for hanging fans; and similar small articles conforming to Fe 209 Gde E-165 including necessary welding etc and fixed in position, complete all as specified and directed by Engineer-in-Charge.
S&F 100 mm butt hinges medium weight cold rolled mild steel, ISI marked, fixed to angle iron chowkats including welding, complete all as specified and directed by Engineer-in-Charge.
S&F Aluminium, anodised, barrel tower bolts 150mm long of extruded section, complete all as specified and directed by Engineer-in-Charge.
S&F Aluminium handles 125 mm size, . type, anodised, complete all as specified and directed by Engineer-in-Charge.
S&F 32mm dia PVC waste pipe flexible type for WHB 60cm long with union, complete all as specified and directed by Engineer-in-Charge.
Toilet paper holder of vitreous china fixed to walls with chromium plated (CP) brass screws(Make- PRAYAG CAT PART NO-BA-88 or equivalent of JAQUAR ,MARC,HINDWARE &PARRY WARE) fixed in repair, complete all as specified and directed by Engineer-in-Charge.
M&L Chromium plated Overhead Rain shower with relvoling joint and 115mmlong shower arm with wall flange 15 mm bore fancy type any colour (Make- JAQUAR CAT PART NO OHS-7489 or equivalent of MARC,HINDWARE &PARRY WARE) and fixed in repair, complete all as specified and directed by Engineer-in-Charge.
M&L Chromium plated angle stop cock with wall flange fancy type cast copper alloy 15 mm bore any colour (Make-JAQUAR CAT PART NO SOL-6053 equivalent of MARC,HINDWARE &PARRY WARE) fixed in repair, complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC valve less syphonic action type low level flushing cistern coloured with inlet ball valve float and handle incl bracket 10 Lit capacity, complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Flush pipe of polyethylene of low or high density of PVC, 32 mm dia, for low level cistern, complete all as specified and directed by Engineer-in-Charge.
S&F Waste fittings 32mm bore, brass, CP for glazed ware sinks, basins, etc. with long screwed shanks & fly-nuts, flange end bedded in red lead cement & other end fixed, complete all as specified and directed by Engineer-in-Charge.
S&F CP bottle trap with internal partition 32 mm size with 300 mm X 190 mm long wall connection pipe and wall flange for WHB (Make- CERA CAT PART NO CM 104 B or equivalent, complete all as specified and directed by Engineer-in-Charge.
S&F vitreous china wash down water closet pan ( Pedestal pattern ),white including connection to drain (or outgoing pipe) and to flushing pipe,anti-sypohonage pipe etc. & with plastic WC seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete including Cisteren and all necessary fittings, complete all as specified and directed by Engineer-in-Charge.
S&F Vitreous China wash hand basin top rest oval shaped flat back basin including half pedastal CERA Part No 1071 CYRCSS white / , coloured, , size 610x560mm including CP waste coupling but excluding taps, waste chain & plug, complete all as specified and directed by Engineer-in-Charge.
M&L CP cast copper alloy bib taps two way with wall flange and areator fancy type of 15 mm bore quarter turn, complete all as specified and directed by Engineer-in-Charge.
M&L 40mm thick PCC (1:2:4) type B0 as in DPC to horizontal or vertical surfaces including necessary formwork, complete all as specified and directed by Engineer-in-Charge.
M&L for machine cut Marble slab of any shade other than white and black 16 to 18 mm thick in risers & treads of steps, jambs, pillars, window cills, cooking platform and similar work over & including 20mm thick screed bed (bedding layer) in CM 1:6, pointing in white cement (1:2) using marble dust with admixture of pidment to match with marble shade including cutting and polishing (half mirror polish i.e half granite polish as per local trade practice), complete all as specified and directed by Engineer-in-Charge.
Vitreous China urinals, bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe including waste pipe of polyethylene of low or high density of PVC, 32 mm dia, for low level cistern, complete all as specified and directed by Engineer-in-Charge.
M&L for Providing, precast cement concrete blocks or slab 150mm thick 1:2:4 type B1 using 20mm graded stone aggregate with plain or inter locking joints as directed set in CM 1:6 kerbing/ edge block to hard standing/footh including necessary earth work, complete all as specified and directed by Engineer-in-Charge.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, set jointed over 25 mm thick sand cushioning, complete all as specified and directed by Engineer-in-Charge.
M&L Soakage wells of 3.6 m dia and 6.0m effective depth including excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of std size, complete all as specified and directed by Engineer-in-Charge.
M&L On site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc, complete all as specified by engineer In Charge.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 Sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 SQmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 25 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and unwelded sunken galvanized pressed steel terminal boxes covered with 3mm thick hylam/phenolic laminate while sheet cover for mounting switches, sockets, fan regulators as required for the following
(a) One light / fan controlled by one switch.
(b) One socket outlet 6 amp controlled by one switch on the same board with other switches.
S&F switch piano flush button type 230 / 250 V grade on top covers single pole one way 6 amp, complete all as specified and directed by Engineer-in-Charge.
S& F socket outlet 2 in 1, 2, & 3 pin, 6 amp, flush type multipurpose use flush mounting type 230 / 250 Volts grade (ISI Marked) on top covers complete, complete all as specified and directed by Engineer-in-Charge.
S& F Celling rose 3 plates polycarbonate body complete, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing wall mounting box type LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed by Engineer-in-Charge.
S & F MCB DB SPN 4 way double door suitable for 240 V complete all as directed including the following MCBs :- (a) MCB SPN 06 Amps, 10 KA - 01 No (b) MCB SP 06 Amps, 10 KA - 02 Nos
Earthing complete with galvanised steel earth plate electrode 600mmx600mmxthickness not less than 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electric plate No 3 connected to earth test point/MCB DBs all as specified and indicated compete with funnel, charcoal, dust, salt etc and GI protection pipe, medium grade 15mm bore and GI watering pipe 20mm bore light grade, 40mm thick precast RCC M-15 (nomial mix) cover reinforced with XPM weight not less than 4 Kg/Sqm with suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover, PCC M-15 (Nominal mix) pit, excavation and earth work in any type of soil and connected all as specified .Note:-soil used for filling should be free from stones.
Supply, laying, jointing and testing of 16 Sqmm, 2 core, LT underground cables, 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty armoured, with multistandred aluminium conductors, ISI marked, laid in trenches/walls/laid under roads/path or encased in GI pipe, complete all as specified and directed by Engineer-in-Charge
Sand cushioning for cables 8 cm below the cable and 15 cm above the cable complete all as specified and directed, complete all as specified and directed by Engineer-in-Charge
Brick protection with sub class 'B' old size brick well burnt laid flat for cable protection abutting each other laid dry with width equal to length of brick , complete all as specified and directed by Engineer-in-Charge
S&F GI pipe light grade with all fittings and fixed complete to wall & ceilings or laid in floor / trench of size 40 mm bore, complete all as specified and directed by Engineer-in-Charge
Supply and fixing MCB SPN, 240 Volts 6 Amps 10 KA in Existing panel, complete all as specified and directed by Engineer-in-Charge
Supply & laying galvanised Pipe, medium class, supplied and laid including fittings complete all as specifiied and directed by EIC for 25mm dia size of pipe complete.
Supply & fixing 25mm Gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe or for unions, complete all as specified and directed by Engineer-in-Charge
Brick masonry valve pit of size 60x60x60 cm (internal dimension of chamber incl plastering internal and flash pointing external as the work proceeds in same mortar complete with MS sheet cover handle, packing arrangement,earth worth in any type of soil incl removal to n.exc 50 mtr and paint with 2 coats of synthetic enamelled paint over a coat of red oxide primer to steel surfaces, complete all as specified and directed by Engineer-in-Charge
Cutting of existing CI/DI/GI water main pipe in position upto size 150 mm bore for insertion of new tees, branches etc complete all as specified and directed by Engineer-in-Charge (cast iron fittings such as tee, bends, collar, reducer etc shall be measured/paid separately).
RAMJI LAL & SONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .