Tender Value
₹30.8 L
EMD Value
₹61,640
Closing Date
17 Jun 2026, 3:00 pmClosed
Executive Engineer (E)
EEE PWD DHC and ND/Central G.F. MSO Bldg. ND
1) Maintenance and operation of E and M service at Chief Election officer, Kashmere Gate, New Delhi. 2) Maintenance and operation of E and M services at MSO Building, New Delhi. (SH - Comprehensive Maintenance of Vertive make PAC system).
2026_PWD_293286_1
62/EE(E)/PWDDHC,ND/C/2026-27
Open Tender
Electrical Works
Works
365 days
New Delhi
Please refer Tender documents.
17 documents required · 17 mandatory
₹0
₹61,640
20 Jun 2026
11 Jun 2026
17 Jun 2026
11 Jun 2026
17 Jun 2026
11 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Comprehensive maintenance and minor repair of Precision Air Conditioning Machine of following size capacity suitable for critical technology/ equipment room direct expansion microprocessor Precision Air Conditioner with allied accessories, piping, controller, etc installed at MSO Building & CEO Kashmiri Gate.
1.1) 7.5 kW, 2 TR PAC
1.1.1) Datamate, 7.5 kW, 2 TR, 3Ph, 415 Vac, 50 Hz, R407C, Air Conditioning Machine at 3rd Floor Server Room | 12 | Months | 11,103 | ₹1,33,236 |
| 2 | 1.1.2) Datamate, 7.5 kW, 2 TR, 3Ph, 415 Vac, 50 Hz, R407C, Air Conditioning Machine at 11th Floor Server Room | 12 | Months | 11,103 | ₹1,33,236 |
| 3 | 1.1.3) Datamate, 7.5 kW, 2 TR, 3Ph, 415 Vac, 50 Hz, R407C, Air Conditioning Machine at 11th Floor Server Room | 12 | Months | 11,103 | ₹1,33,236 |
| 4 | 1.1.4) Datamate, 7.5 kW, 2 TR, 3Ph, 415 Vac, 50 Hz, R407C, Air Conditioning Machine at 11th Floor Server Room | 12 | Months | 11,103 | ₹1,33,236 |
| 5 | 1.1.5) Datamate, 7.5 kW, 2 TR, 3Ph, 415 Vac, 50 Hz, R407C, Air Conditioning Machine at 11th Floor Server Room | 12 | Months | 11,103 | ₹1,33,236 |
| 6 | 1.2) 12.5 kW, 3 TR PAC
1.2.1) Datamate, 12.5 kW, 3 TR, 3 Ph, 415 Vac, 50 Hz, R407C, Air Conditioning Machine at 7th Floor Server Room | 12 | Months | 14,205 | ₹1,70,460 |
| 7 | 1.2.2) Datamate, 12.5 kW, 3 TR, 3 Ph, 415 Vac, 50 Hz, R407C, Air Conditioning Machine at 11th Floor Server Room | 12 | Months | 14,205 | ₹1,70,460 |
| 8 | 1.2.3) Datamate, 12.5 kW, 3 TR, 3 Ph, 415 Vac, 50 Hz, R407C, Air Conditioning Machine at 11th Floor Server Room 12 Months 14205.00 Month 170460.00 | 12 | Months | 14,205 | ₹1,70,460 |
| 9 | 1.2.4) Datamate, 12.5 kW, 3 TR, 3 Ph, 415 Vac, 50 Hz, R407C, Air Conditioning Machine at 11th Floor Server Room | 12 | Months | 14,205 | ₹1,70,460 |
| 10 | 1.2.5) Datamate, 12.5 kW, 3 TR, 3 Ph, 415 Vac, 50 Hz, R407C, Air Conditioning Machine at 11th Floor Server Room | 12 | Months | 14,205 | ₹1,70,460 |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.73 MB
BOQ_389709.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .