Loading…
Loading…
Tender Value
₹89.4 L
EMD Value
₹1.8 L
Closing Date
12 Mar 2026, 10:30 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
45 days
Expenditure
Capital (Works)
Above/Below/Par
GENERAL
17 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees. N = Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of 'total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The balance sheet and all other financial documents attested/certified by CAs to substantiate fulfilment of Financial Eligibility Criteria should be with UDIN, failing which the offer is likely to be rejected without any further reference.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Substantially Completed Work means an ongoing work in which payment equal to or more than 90% of the present contract value (excluding the payment made for adjustment of Price variation (PVC), if any) has been made to the contractor in that ongoing contract and no proceedings of termination of contract on Contractor's default has been initiated. The credential certificate in this regard should have been issued not prior to 60 days of date of invitation of present tender.
Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Defination of Similar Work :- Supply, installation, testing and commissioning of HT panels/LT panels, cable laying, wiring/rewiring of any building/office in central government or state government or public sector undertakings (also called Public sector Undertakings (also called public sector enterprise)
52 conditions · 6 needing a document upload
Performance Guarantee: As per Indian Railways Standard General Condition of Contract 2022. 16.(4) Performance Guarantee The procedure for obtaining Performance Guarantee is outlined below: (a) The successful bidder shall have to submit a Performance Guarantee (PG) within 21 (Twenty one) days from the date of issue of Letter of Acceptance (LOA). Extension of time for submission of PG beyond 21 (Twenty one) days and upto 60 days from the date of issue of LOA may be given by the Authority who is competent to sign the contract agreement. However, a penal interest of 12% per annum shall be charged for the delay beyond 21(Twenty one) days, i.e. from 22ndday after the date of issue of LOA. Further, if the 60thday happens to be a declared holiday in the concerned office of the Railway, submission of PG can be accepted on the next working day. In all other cases, if the Contractor fails to submit the requisite PG even after 60 days from the date of issue of LOA, the contract is liable to be terminated. In case contract is terminated railway shall be entitled to forfeit Bid Security and other dues payable to the contractor against that particular contract, subject to maximum of PG amount. In case a tenderer has not submitted Bid Security on the strength of their registration as a Startup recognized by Department of Industrial Policy and Promotion (DIPP) under Ministry of Commerce and Industry, DIPP shall be informed to this effect. The failed Contractor shall be debarred from participating in re-tender for that work. (b) The successful bidder shall submit the Performance Guarantee (PG) in any of the following forms, amounting to 5% of the original contract value:- (i) A deposit of Cash; (ii) Irrevocable Bank Guarantee; (iii) Government Securities including State Loan Bonds at 5% below the market value; (iv) Pay Orders and Demand Drafts tendered by any Scheduled Commercial Bank of India; (v) Guarantee Bonds executed or Deposits Receipts tendered by any Scheduled Commercial Bank of India; (vi) Deposit in the Post Office Saving Bank; (vii) Deposit in the National Savings Certificates; (viii) Twelve years National Defence Certificates; (ix) Ten years Defence Deposits; (x) National Defence Bonds a n d (xi) Unit Trust Certificates at 5% below market value or at the face value whichever is less. Also, FDR in favour of FA&CAO (free from any encumbrance) may be accepted.
The Performance Guarantee shall be submitted by the successful bidder after the Letter of Acceptance (LOA) has been issued, but before signing of the contract agreement. This P.G. shall be initially valid upto the stipulated date of completion plus 60 days beyond that. In case, the time for completion of work gets extended, the Contractor shall get the validity of P.G. extended to cover such extended time for completion of work plus 60 days. (d) The value of PG to be submitted by the Contractor is based on original contract value and shall not change due to subsequent variation(s) in the original contract value. (e) The Performance Guarantee (PG) shall be released after physical completion of the work based on 'Completion Certificate' issued by the competent authority stating that the Contractor has completed the work in all respects satisfactorily. (f) Whenever the contract is rescinded, the Performance Guarantee already submitted for the contract shall be encashed. (g) The Engineer shall not make a claim under the Performance Guarantee except for amounts to which the President of India is entitled under the contract (not withstanding and/or without prejudice to any other provisions in the contract agreement) in the event of: (i) Failure by the Contractor to extend the validity of the Performance Guarantee as described herein above, in which event the Engineer may claim the full amount of the Performance Guarantee. (ii) Failure by the Contractor to pay President of India any amount due, either as agreed by the Contractor or determined under any of the Clauses/Conditions of the Agreement, within 30 days of the service of notice to this effect by Engineer. (iii) The Contract being determined or rescinded under clause 62 of these conditions.
Security Deposit: As per Indian Railways Standard General Condition of Contract 2022. 16.(1) Security Deposit: The Security Deposit shall be 5% of the contract value. The Bid Security submitted by the Contractor with his tender will be retained/encashed by the Railways as part of security for the due and faithful fulfillment of the contract by the Contractor. Provided further that, if Contractor submits the Cash or Term Deposit Receipt issued from a Scheduled commercial bank of India or irrevocable Bank Guarantee Bond from a Scheduled commercial bank of India, either towards the Full Security Depositor the Part Security Deposit equal to or more than Bid Security, the Railway shall return the Bid Security, to the Contractor. Balance of Security Deposit may be deposited by the Contractor in cash or Term Deposit Receipt issued from Scheduled commercial bank of India or irrevocable Bank Guarantee bond issued from Scheduled commercial bank of India, or may be recovered at the rate of 6% of the bill amount till the full Security Deposit is recovered. Provided also that in case of defaulting Contractor, the Railway may retain any amount due for payment to the Contractor on the pending "on account bills" so that the amounts so retained (including amount guaranteed through Performance Guarantee) may not exceed 10% of the total value of the contract. The Irrevocable Bank Guarantee submitted towards Security deposit shall be initially valid up to the stipulated date of Maintenance period plus 60 days and shall be extended from time to time, depending upon extension of contract granted in terms of Clause 17A and 17B of the Standard General Conditions of Contract. Note: Security Deposit deposited in cash by the Contractor or recovered from the running bills of a Contractor or submitted by contractor as Term Deposit Receipt(s) can be refunded/returned to the contractor, in lieu of irrevocable Bank Guarantee bond issued from scheduled commercial bank of India, to be submitted by him, for an amount equal to or more than the already available Security Deposit, provided however that, in a contract of value less than Rs. 50 Crore, such refund/ return of the already available Security Deposit is permitted up to two times and in a contract of value equal to or more than Rs. 50 Crore, such refund / return of the already available Security Deposit is permitted up to three times.
Refund of Security Deposit: Security Deposit mentioned in sub clause (1) above shall be returned to the Contractor along with or after, the following: (a) Final Payment of the Contract as per clause 51.(1) and (b) Execution of Final Supplementary Agreement or Certification by Engineer that Railway has No Claim on Contractor and (c) Maintenance Certificate issued, on expiry of the maintenance period as per clause 50.(1), in case applicable. 16. (2) (ii) Forfeiture of Security Deposit: Whenever the contract is rescinded as a whole under clause 62 (1) of these conditions, the Security Deposit already with railways under the contract shall be forfeited. However, in case the contract is rescinded in part or parts under clause 62 (1) of these conditions, the Security Deposit shall not be forfeited. 16.(3) No interest shall be payable upon the Bid Security and Security Deposit or amounts payable to the Contractor under the Contract, but Government Securities deposited in terms of Sub- Clause 16.(4) (b) of this clause will be payable with interest accrued thereon
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
@ 18% GST has been included in schedule rate, GST will be paid to the firm's at the time of billing, subjected to firm's production of sufficient documentary evidences in support of same. NOTE: % of GST as applicable during the period of execution.
Inspection charges of RITES / Third Party Inspection (TPI) Agencies are to be borne by the contractor where necessary as per extent rule (where the value of purchase order exceeds Rs. 5 lakhs)
The work shall be treated as on work contract basis and the rates tendered shall be for complete items of work (except the materials, if any, stipulated for supply by the department) inclusive of all taxes (including works contract tax,if any duties, and levies etc and all charges for items contingent to the work, such as packing, forwarding, insurance, freight and delivery at site for the materials to the supplied by the contractor, watch and ward of all materials (including those if any supplied by the department) for the work at site etc.)
Unless and otherwise mentioned in the tender documents, the following works shall be done by the contractor, and therefore their cost shall be deemed to be included in their tendered cost- i)Foundations for equipments and components where required, including foundation bolts. ii)Cutting and making good all damages caused during installation and restoring the same to their original finish. iii)Sealing of all floor openings provided by him for pipes and cables, from fire safety point of view, after laying of the same. iv)Painting at site of all exposed metal surfaces of the installation other than pre-painted items like fittings , fans, switchgear/distribution gear items, cubicle switch board etc. Damages to finished surfaces of these items while handling and erection, shall however be rectified to the satisfaction of the Engineer-in-charge. v)Testing and commissioning of complete installation
Unless and otherwise specified, power supply and water supply will be arranged by the contractor at the site for installation purpose. However, for testing purpose, electricity supply will be available free of cost to the contractor. Contractor will take due care to ensure safety of electrical installation during execution of work
The contractor shall co-ordinate with all other agencies involved in the building work is not hampered due to delay in his work. Recessed conduit and other works, which directly affect the progress of building work, should be given priority.
Tools for Handling and Erection All tools and tackles required for handling of equipments and materials at site of work as well as for their assembly and erection and also necessary test instruments shall be the responsibility of the contractor
Care of Buildings: Care shall be taken by the contractor to avoid damage to the building during execution of his part of the work. He shall be responsible for repairing all damages and restoring the same to their original finish at his cost. He shall also remove at his cost all unwanted and waste materials arising out of his work from the site.
Structural Alterations to Buildings: (i) No structural member in the building shall be damaged/altered, without prior approval from the competent authority through the Engineer-in-charge. (ii) Structural provisions like openings, cutouts, if any, provided by the department for the work, shall be used. Where these require modifications, or where fresh provisions are required to be made, such contingent works shall be carried out by the contractor at his cost. (iii) All such openings in floors provided by the Department shall be closed by the contractor after installing the cables/ conduits/ rising mains etc. as the case may be, by any suitable means as approved by the Engineer-in-charge without any extra payment. (iv) All chases required in connection with the electrical works shall be provided and filled by the contractor at his own cost to the original architectural finish of the buildings
Addition to an Installation: Any addition temporary or permanent to the existing electrical installation shall not be made without a properly worked out scheme/ design by a qualified Electrical Engineer to ensure that such addition does not lead to overloading, safety violation of the existing system.
Work in Occupied Buildings: (i) When work is executed in occupied buildings, there would be minimum of inconvenience to the occupants. The work shall be programmed in consultation with the Engineer-in-charge and the occupying department. If so required, the work may have to be done even before and after office hours. (ii) The contractor shall be responsible to abide by the regulations or restrictions set in regard to entry into, and movement within the premises. (iii) The contractor shall not tamper with any of the existing installations including their switching operations or connections thereto without specific approval from the Engineer-in-charge.
Conformity to IE Act, IE Rules, and Standards: All Electrical works shall be carried out in accordance with the provisions of Indian Electricity Act, 2003 and Indian Electricity Rules, 1956 amended up to date and As per RDSO specification
Quality of Materials: All materials and equipments supplied by the contractor shall be new. They shall be of such design, size and materials as to satisfactorily function under the rated conditions of operation and to withstand the environmental conditions at site
Inspection of Materials and Equipments: Materials and equipments to be used in the work shall be inspected by the Departmental officers. Such inspection will be of following categories: (i) Inspection of materials/ equipments to be witnessed at the manufacturer's premises in accordance with relevant BIS/ Agreement Inspection Procedure. (ii) To receive materials at site with Manufacturer's Test Certificate(s). (iii) To inspect materials at the Authorized Dealer's Godowns to ensure delivery of genuine materials at site. (iv) To receive materials after physical inspection at site. The Departmental officers will take adequate care to ensure that only tested and genuine materials of proper quality are used in work. Similarly, for fabricated equipments, the contractor will first submit dimensional detailed drawings for approval before fabrication is taken up in the factory. Suitable stage inspection at factory also will be made to ensure proper use of materials, workmanship and quality control. The tender specifications will stipulate the inspection requirements or their waiver for various materials/ equipments including norms of inspection in specific cases
Ratings of Components: All components in a wiring installation shall be of appropriate ratings of voltage, current, and frequency, as required at the respective sections of the electrical installation in which they are used. All conductors, switches and accessories shall be of such size as to be capable of carrying the maximum current, which will normally flow through them, without their respective ratings being exceeded
Conformity to Standards: All components shall conform to relevant Indian Standard Specifications, wherever existing. Materials with ISI certification mark shall be preferred. A broad list of relevant Indian Standards is given in Appendix D. These Indian Standards, including amendments or revisions thereof upto the date of tender acceptance, shall be applicable in the respective contracts
Only quality materials of reputed make as specified in the tender will be used in work.
Testing: All tests, to be done before, during and after installation, shall be carried out, and the test results shall be submitted to the Engineer-in-charge in prescribed Performa, forming part of the Completion Certificate
Commissioning on Completion: After the work is completed, it shall be ensured that the installation is tested and commissioned
Shramikkalyan portal:- (i) Contractor is to abide by the provisions of various labour laws in terms of above clause 54,55, 55-A and 55-B of Indian Railways Standard General Conditions of Contract. In order to ensure the same, an application has been developed and hosted on website 'www.shramikkalyan.indianrailways.gov.in'. Contractor shall register his firm/company etc. and upload requisite details of labour and their payment inthis portal. These details shallbe available in public domain. The registration /updation in Portal shall be done as under: (a)Contractor shall apply for one time registration of his company/firm etc. in the Shramikkalyan portal with requisite details subsequent to issue of Letter of Acceptance. Engineer shall approve the contractor's registration in the portal within 7 days of receipt of such request. (b)Contractor once approved by any Engineer, can create password with login ID (PAN No.) for subsequent use of portal for all Letter of Acceptances (LoAs)issued in his favour. (c)The contractor once registered on the portal, shall provide details of his Letter of Acceptances (LoAs)/ Contract Agreements on shramikkalyan portal within 15 days of issue of any LoA for approval of concerned Engineer. Engineer shall update (if required) and approve the details of LoA filled by contractor within 7 days of receipt of such request. (d)After approval of LoA by Engineer, contractor shall fill the salient details of contract labours engaged in the contract and ensure updating ofeach wage payment to them on shramikkalyan portal on monthly basis. (e)It shall be mandatory upon the contractor to ensure correct and prompt uploading of all salient details of engaged contractual labour & payments made thereof after each wage period. (ii)While processing payment of any'On Account Bill' or 'Final Bill' or release of 'Advances' or 'Performance Guarantee / Security deposit', contractor shall submit a certificate to the Engineer or Engineer's representatives that "I have uploaded the correct details of contract labours engaged in connection with this contract and payments made to them during the wage period in Railway's Shramikkalyan portal at 'www.shramikkalyan.indianrailways.gov.in' till____Month,____Year.
Please read the Explanatory note for detail description of work, their make etc and all other attached documents before submission of Tender.
Any other reputed make/ brand other than as mentioned in the explanatory note may be included during the execution of the works on an urgent basis/as per direction when needed with approval of competent authority.
Electrical work for Laundry Building-Santragachi.
ELECT-CHG-25-26-LDRY-S-40~SER
ELECT-CHG-25-26-LDRY-S-40
Open
Works - General
12 Months
Howrah, West Bengal
₹0
₹1.8 L
12 Mar 2026
11 Feb 2026
26 Feb 2026
158 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 51,41,268.96 | ||
| — | 75.00 | — | — | ||
| Supply of 20W or higher wattage LED tube light with Batten ( integrated electronic driver).As per CEGE approved Specification for LED tube light-high power,2100 Lumen output,220V, 50Hz AC with constant current driver with short circuit and overload protection etc. | — | — | — | 25,296.75 | |
| — | 75.00 | — | — | ||
| Fixing and Commisioning of 20W or higher wattage LED tube light with Batten. | — | — | — | 3,044.25 | |
| — | 40.00 | — | — | ||
| "Supply of40W or higher wattage LED tube light with Batten, IP65 corrosion resistant, glarefree, impact proof, surface mounting MCPCB based LED, CRI 80 +, 4000 Kelvin or more, similar to the product Century LED Elite prime capsule cat ref No XCEL040C ( integrated electronic driver). | — | — | — | 1,57,830.4 | |
| — | 40.00 | — | — | ||
| Fixing and Commisioning of 40W or higher wattage LED tube light with Batten. | — | — | — | 1,428.8 | |
| — | 20.00 | — | — | ||
| Supply, of LED High Bay light fittings 200W LED, LED chip Efficacy (Lumen/watt) 130, Luminaire System Efficacy - Lumen output - (Lumen/watt) 120, 6000 K IP-65, IK 07. Accessories for each luminaire: Metallic adjustable Brackets (Stainless steel),SS Eye Bolts (as per IS:4190:1984 latest),Set of Bolt,Nut, Washers (SS),Die cast aluminium brackets etc. ISI Marked 3 Core cable for input power ( min Length:250 mm ).Test report from NABL lab to be submitted Warranty period (in Months) 36 or more. | — | — | — | 5,25,423.8 | |
| — | 20.00 | — | — | ||
| Fixing and commissioning of LED High Bay light fittings. | — | — | — | 5,977.4 | |
| — | 14.00 | — | — | ||
| Supply, of LED Street light fittings 45W LED, LED chip Efficacy 130 Lm/Watt, IP-66. Light should be as per HQ specification. | — | — | — | 17,796.66 | |
| — | 14.00 | — | — | ||
| Fixing and commissioning ofLED Street light fittings45 W LED, IP-66. | — | — | — | 1,779.68 | |
| — | 1.00 | — | — | ||
| Supply and Testing of TTA Make Distribution panel, consisting of Incoming- MCCB 4P 400 A Qty -01, Outgoing -i) MCCB 4P 250 A Qty -02, ii) MCCB 4P 100 A Qty - 02, iii) MCB 2P 63 A Qty - 02, iv) MCB 2P 40 A Qty- 04 v) MCB 2P 32 A Qty- 04 with suitable TPN 400 A copper busbar, indication lights, suitable spreder link, contactor with all modern facilites required for scada, volt meter, amp meter energy meter time switches etc. | — | — | — | 5,56,000 | |
| — | 1.00 | — | — | ||
| Erection, Installation and commissioning of TTA make Distribution panel . including civil job. | — | — | — | 34,513.7 | |
| — | 2.00 | — | — | ||
| Supply and Testing of TTA Make Distribution panel, consisting of Incoming- MCCB 4P 100 A Qty -01, Outgoing -i) MCCB 4P 63A Qty -02, ii) MCB 3P 40 A Qty - 02, iii) MCB 2P 40 A Qty - 02,with suitable TPN 100 A copper busbar, indication lights, suitable spreder link, contactor with all modern facilites required for scada, volt meter, amp meter energy meter time switches etc.. Panel should be as per IEC 61439 or latest. | — | — | — | 4,66,000 | |
| — | 2.00 | — | — | ||
| Erection, Installation and commissioning of TTA make Distribution panel . including civil job. | — | — | — | 69,027.4 | |
| — | 4.00 | — | — | ||
| "Supply of SP&N 12-way DB (SD) Thermoplastic Circuit breaker boxes IP 65 (with metric knockouts for cable entry)consisting with DP 32A 10kA MCB-1 no as incoming and SP 20 A,10kA MCB - 4 nos, SP 16 A,10kA MCB - 4 nos, as outgoing with Neutral links and Earth bar etc., | — | — | — | 39,756.6 | |
| — | 4.00 | — | — | ||
| Fixing and Commisioning of SP&N 12-way DB (SD) Thermoplastic Circuit breaker boxes IP 65 (with metric knockouts for cable entry)consisting with DP 32A 10kA MCB-1 no as incoming and SP 20 A,10kA MCB - 4 nos, SP 16 A,10kA MCB - 4 nos, as outgoing with Neutral links and Earth bar etc., | — | — | — | 1,445.88 | |
| — | 5.00 | — | — | ||
| Supply of TP&N 6-way DB (DD) consisting with FP 63A 10kA MCB-1 no as incoming and 20A 10kA SP MCB-8 Nos, 16A 10kA SP MCB-8 Nos as outgoingwith Cu.bus-bar, Neutral links , Spreader Link, Earth bar and DinRail etc.,(ALL MCB will be C series.Thickness of material (in mm)1.6 mm (MSsheet). | — | — | — | 36,478.8 | |
| — | 5.00 | — | — | ||
| Fixing and Commisioning of TP&N 6-way DB (DD) consisting with FP 63A 10kA MCB-1 no as incoming and 20A 10kA SP MCB-8 Nos, 16A 10kA SP MCB-8 Nos as outgoingwith Cu.bus-bar, Neutral links , Spreader Link, Earth bar and DinRail etc., with complete wiring and accessories to complete job. | — | — | — | 2,437.7 | |
| — | 10.00 | — | — | ||
| Supply of Industrial type Socket 3 phase 5 pin, (3P+1N+1E) 125Amp IP 67 with mechanical interlocking and plug 125 amp 3P + N + E water tight IP 67(similar to hensel cat no 9755100 and 045-6). | — | — | — | 9,11,400 | |
| — | 10.00 | — | — | ||
| Installation & commissioning of Industrial type Socket and plug with all accesssories. | — | — | — | 5,983.2 | |
| — | 15.00 | — | — | ||
| Supply of Industrial type Socket 3 phase 5 pin, (3P+1N+1E) 63Amp IP 67 with mechanical interlocking and plug 63 amp 3P + N + E water tight IP 67(similar to hensel cat no 75352-6 and 035-6). | — | — | — | 4,51,500 | |
| — | 15.00 | — | — | ||
| Installation & commissioning of Industrial type Socket and plug with all accesssories. | — | — | — | 8,974.8 | |
| — | 20.00 | — | — | ||
| Supply of 40 amps C series MCB 2 pole -qty -2 with suitable enclosure. | — | — | — | 64,406.8 | |
| — | 20.00 | — | — | ||
| Fixing and Commissioning of 40 amps C series MCB 2 pole -qty -2 w ith suitable enclosure. | — | — | — | 3,220.4 | |
| — | 20.00 | — | — | ||
| Supply of Cable Junction Boxes of size (Box Dimensions LXBXH in mm) 450x375x200 mm or as per site requirement, IP 65 with metric knockouts for cable entry with 3-Phase in- coming and out going connection consists of 3-Phase and neutral terminal as per relevant ISS, with suitable bridge arrange- ment with all necessary accessories. Make-IS standard Indian make | — | — | — | 47,000 | |
| — | 20.00 | — | — | ||
| Fixing and commissioning of Cable junction box ( of fibre body) for 3-Phase in- coming and out going connection consists of 3-Phase and neutral terminal as per relevant ISS, with suitable bridge arrange- ment of size : 450mm X 375mm x 200 mm or as per site requirement.,as per relevent specification/drawing. Fixing shall be made with necessary arrangements as per site requirement, cables are to be terminated with proper socketing arrangement to complete job. | — | — | — | 1,163.6 | |
| — | 10.00 | — | — | ||
| Supply of Brushless DC (BLDC) Motor Ceiling Fan, ISI marked, Sweep size: 1400 mm, Minimum Air delivery-210 Cubic Meter/Min, total harmonic distortion- 8% [max], Rated Voltage: 230 V,50HZ Single phase AC, Blade thickness (Min): 1.1mm, Blade material : Aluminium, Bearing: Double ball bearings, Down rod size (without shackle) : 300mm, Shank & Shackle thickness(Min) : 2mm, canopy : 2 nos., colour standard: white, BEE rating : 5 star (as per Ministryof Power Notification Number: S.O. 2210 (E) and S.O. 2211 (E) dated. 12th May 2022 or latest), Rated power-28 watt [max], Warranty [Min] 30 Months. Conforming to- (i)IS:374/2019 with Amendment No. 1/2022 or latest (ii)IS:302 (Part 2/Sec 80) - For safetyrequirement (iii)IS:14700 (Part 3/Sec2) for THD. Speed control with electronic regulator(step type with minimum 5 running positions) and Regulators shall be provided with radioand television interference suppressing devices as per clause 10.7 of Amendment No. 1/2022to IS 374/2019 or latest. | — | — | — | 24,000 | |
| — | 10.00 | — | — | ||
| Fixing and commissioning of Brushless DC (BLDC) Motor Ceiling Fan, ISI marked, Sweep size: 1400 mm, suitable for 230V, 50Hz, AC supply confirming to Class:I of IS: 374/latest. Fixing of the fan shall be done with suitable clamp, hook, nut/bolts etc. and connection with flexible twin twisted multistrand Copper wire and removing of the existing old fan (if any) and handing over of the same to Railway Store with clear acknowledgement, as per site requirement. | — | — | — | 1,162.2 | |
| — | 20.00 | — | — | ||
| Supply of Wall Mounted Fan with Brushless DC (BLDC) Motor, sweep size 400 mm with feature of Oscillaton & Vertcal Adjustable Tilt Mechanismn Minimum Air Delivery 65 cubic meter/min,Rated Voltage: 230 V, 50Hz, Single phase AC, Motor Winding Material: Copper, No. ofBlades-3, Provided with Pull cord or string based speed control mechanism with minimum 3 speed stepsn Colour: White, Minimum Service Value 1.43 as per BEE 5 star rating (BEE's Schedule- 32, Table & Wall-Mounted Fan), Conforming to IS 555:1979 (Reaffirmed Year: 2020) with all amendments. | — | — | — | 92,203.4 | |
| — | 20.00 | — | — | ||
| Fixing and Commissioning of Wall Mounted Fan WITH 5 STAR and above RATING 400 mm size , suitable for 230V, 50Hz, AC supply as per site requirement. | — | — | — | 2,574.4 | |
| — | 6.00 | — | — | ||
| Supply of Moduler type Exhaust Fans300 mm , 1400 RPM suitable for 230V, 50Hz, AC supply, Conformity to Indian Standrad IS: 2312 (latest).accessories such as Frame, Legs Set,Rubber Clamps & Other Hardware - inclusive in the scope of supply. | — | — | — | 13,611.84 | |
| — | 6.00 | — | — | ||
| Fixing and commissioning of Heavy Duty Exhaust Fans as per consignee requirement. | — | — | — | 777.3 | |
| — | 8.00 | — | — | ||
| Supply of Earthing arrangement with supply of Hot Dip Galvanized (HDG) earth cone and all other requisite materials as per CEE/GRC's Drg. No.CEE/G/A3/P-150, Alt.1 including sump box with salt and charcoal, metalic cover etc. as per site supervisor's instruction. Cost includes supply of all materials mentioned in the Drawing including 02 mtrs 25x5mm GI strip for connection from earth electrod pipe to light pole /Rail pole etc. Make: Any IS standard Indian make. | — | — | — | 29,400.96 | |
| — | 8.00 | — | — | ||
| Erection of Earthing arrangement with erection of Hot Dip Galvanized (HDG) earth cone and all other requisite materials as per CEE/GRC's Drg. No.CEE/G/A3/P-150, Alt.1 including sump box with salt and charcoal, metalic cover etc. as per site supervisor's instruction. Cost includes erection of all materials mentioned in the Drawing including 02 mtrs 25x5mm GI strip for connection from earth electrod pipe to light pole /Rail pole etc. | — | — | — | 7,092.96 | |
| — | 100.00 | — | — | ||
| Concealed Wiring of light and fan point by 1.5 sq. mm, Single Core, Multistrand (22/0.3mm), Copper Conductor (flexible), Unsheathed, Flame Retardant Low Smoke and Halogen(FR- LSH), PVC insulated Cable of 1100V grade, Type-C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked. Earthing the point with 1.5 sq. mm, Single Core, Multistrand (22/0.3mm), Copper Conductor (flexible), Unsheathed, FR-LSH, PVC insulated Cable of 1100V grade, Type-C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked,through PVC Conduit Pipe of Nominal Size 20mm/25mm(as per site requirement) and in the length of 3 mtrs, Socket ended (at one end ), medium mechanical stress, White Color, Resistant to Flame Propagation to grade UL-94 V0, Conforming to IS 9537 (Part 3) 1983 (Reaffirmed Year : 2017) with amendment no. 2 or latest with ISI mark. Modular Electrical Switch, 6 A, 230 V, SP, 1 Way, 1 Module, Unenclosed type as per Clause no.7.1.3, Method of Activation of switch shall be of Rocker type as per Clause no. 7.1.5, Switch shall be Flush type as per Clause no.7.1.6 and shall be installed as per Design A mentioned in the Clause no.7.1.7, Current carrying material as per Clause no. 22.5, with cover made of tough non-ignitable insulating material and bare of tough non-ignitable insulating material or of vitrified ceramic material, Conforming to IS:3854/1997 (reaffirmed 2017) with latest amendments and ISI mark. including supply of all required materials like lamp holder,Aluminium, batten type, with shade carrier ring,ISI marked, Base: B-22 suitable for use at 250V, Conforming to IS: 1258(Rev.-3)-2005)with amdt-3. With BACK plate of 53 MM. Dia & 45 MM PCD.., ceiling rose, Modular type Socket outlet suitable for 3 pin plug, 6A, 230V, 2 Module, Shuttered (Operation of Shutter should be independant of Earthing Point), Cover made of tough Non-Ignitable insulating material, material of base -vitrified ceramic, Conforming to IS : 1293-2019, Amendment no. 1 or latest with ISI mark ,suitable moduler stainless steel JB box with moduler PVC cover , stainless steel switch Board with moduler PVC cover,PVC Spacers, PVC Saddles,PVC Bends, PVC Tees to be provided as and where required as per direction of consignee,. Provision of moduler fan regulator should be kept on switch board . The plate should include 2 blank space for further installation of switches.including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. All materilas would be as per latest specification as issued from HQ/GRC time to time if available or latest IS and IE rules which is available.Covers or cover parts or parts of them, which are intended to ensure protection against electric shock, shall be held in place at two or more points by effective fixings..The cost includes supply of all materials to complete job. ( Two 5-ampere socket point treated as one point). | — | — | — | 76,695 | |
| — | 350.00 | — | — | ||
| "Concealed Sub circuit wiring by 2.5 sq. mm, Single Core, Multistrand (36/0.3mm), Copper Conductor(flexible), Unsheathed, Flame Retardant Low Smoke and Halogen (FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS: 694- 2010(reaffirmed 2020), ISI marked. with 2.5Sq mm earthing wire of Single Core, Multistrand (36/0.3mm), Copper Conductor(flexible), Unsheathed, Flame Retardant Low Smoke and Halogen (FR- LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS: 694-2010(reaffirmed 2020), ISI marked. through PVC Conduit Pipe of Nominal Size 25mm and in the length of 3 mtrs, Socket ended (at one end ), medium mechanical stress, White Color, Resistant to Flame Propagation to grade UL-94 V0, Conforming to IS 9537 (Part 3) 1983 (Reaffirmed Year : 2017) with amendment no. 2 or latest with ISI mark with Supply & fixing of PVC Circular Box and Ceiling rose if required with connection from running circuit as per direction of Consignee. including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. All materilas would be as per latest specification as issued from HQ/GRC time to time if available or latest IS and IE rules which is available.The cost includes supply of all materials to complete the job. *Quantity per meter means-one meter conduit with 2 (two) meters Cu. cable of size 2.5 sq mm for phase & neutal and 1mtr of 2.5 Sq.mm PVC Cu. cable as earthing with Supply of PVC Circular Box and Ceiling rose as per direction of Consignee. | — | — | — | 54,575.5 | |
| — | 200.00 | — | — | ||
| "Concealed Sub circuit wiring by 4 sq. mm, Single Core, Multistrand (56/0.3mm), Copper Conductor (flexible), Unsheathed, Flame Retardant Low Smoke and Halogen(FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked with 4 Sq mm earthing wire of Single Core, Multistrand (56/0.3mm), Copper Conductor (flexible), Unsheathed, Flame Retardant Low Smoke and Halogen(FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked through PVC Conduit Pipe of Nominal Size 25mm and in the length of 3 mtrs, Socket ended (at one end ), medium mechanical stress, White Color, Resistant to Flame Propagation to grade UL-94 V0, Conforming to IS 9537 (Part 3) 1983 (Reaffirmed Year : 2017) with amendment no. 2 or latest with ISI mark including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. All materilas would be as per latest specification as issued from HQ/GRC time to time if available or latest IS and IE rules which is available.The cost includes supply of all materials to complete the job. *Quantity per meter means-one meter conduit with 2 (two) meters Cu. cable of size 4 sq mm for phase & neutal and 1mtr of 4 Sq.mm PVC Cu. cable as earthing. | — | — | — | 41,016 | |
| — | 30.00 | — | — | ||
| Point Wiring by PVC conduit /PVC Casing & Capping : -- Internal wiring for light, fan , plug points and night lamp points by 1.5 sq. mm, Single Core, Multistrand (22/0.3mm), Copper Conductor (flexible), Unsheathed, Flame Retardant Low Smoke and Halogen(FR-LSH), PVC insulated Cable of 1100V grade, Type-C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked.Earthing the point with 1.5 sq. mm, Single Core, Multistrand (22/0.3mm), Copper Conductor (flexible), Unsheathed, Flame Retardant Low Smoke and Halogen(FR- LSH), PVC insulated Cable of 1100V grade, Type-C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked through PVC Conduit Pipe of Nominal Size 25mm and in the length of 3 mtrs, Socket ended (at one end ), medium mechanical stress, White Color, Resistant to Flame Propagation to grade UL-94 V0, Conforming to IS 9537 (Part 3) 1983 (Reaffirmed Year : 2017) with amendment no. 2 or latest with ISI mark. or PVC Casing & capping, ISI marked, white color, double locking, Resistant to Flame Propagation to grade UL-94 V0, as per IS:14927 Part 2 : 2001 (Reaffirmed Year : 2017 ) or latest, Standard Length: 2 meter, Size: 25x16mm. including Modular Electrical Switch, 6 A, 230 V, SP, 1 Way, 1 Module, Unenclosed type as per Clause no.7.1.3, Method of Activation of switch shall be of Rocker type as per Clause no. 7.1.5, Switch shall be Flush type as per Clause no.7.1.6 and shall be installed as per Design A mentioned in the Clause no.7.1.7, Current carrying material as per Clause no. 22.5, with cover made of tough non-ignitable insulating material and bare of tough non-ignitable insulating material or of vitrified ceramic material, Conforming to IS:3854/1997 (reaffirmed 2017) with latest amendments and ISI mark., including supply of all required materials like lamp holder,Aluminium, batten type, with shade carrier ring,ISI marked, Base: B-22 suitable for use at 250V, Conforming to IS: 1258(Rev.-3)-2005)with amdt-3. With BACK plate of 53 MM. Dia & 45 MM PCD.., ceiling rose, Modular type Socket outlet suitable for 3 pin plug, 6A, 230V, 2 Module, Shuttered (Operation of Shutter should be independant of Earthing Point), Cover made of tough Non-Ignitable insulating material, material of base -vitrified ceramic, Conforming to IS : 1293-2019, Amendment no. 1 or latest with ISI mark ,suitable PVC moduler JB box ,switch Board, Spacers, Saddles,Bends, Tees to be provided as and where required as per direction of consignee,. Provision of moduler fan regulator should be kept on switch board .The plate should include 2 blank space for further installation of switches.including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. All materilas would be as per latest specification as issued from HQ/GRC time to time if available or latest IS and IE rules which is available.The cost includes supply of all materials to complete job. ( Two 5-ampere socket point treated as one point). | — | — | — | 20,847.6 | |
| — | 90.00 | — | — | ||
| "Circuit/Sub-circuit wiring by PVC conduit/PVC casing capping wiring by 2.5 sq. mm, Single Core, Multistrand (36/0.3mm), Copper Conductor(flexible), Unsheathed, Flame Retardant Low Smoke and Halogen (FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS: 694-2010(reaffirmed 2020), ISI marked.Continuous Earthing with 2.5 sq. mm, Single Core, Multistrand (36/0.3mm), Copper Conductor(flexible), Unsheathed, Flame Retardant Low Smoke and Halogen (FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS: 694-2010(reaffirmed 2020), ISI marked through PVC Conduit Pipe of Nominal Size 25mm and in the length of 3 mtrs, Socket ended (at one end ), medium mechanical stress, White Color, Resistant to Flame Propagation to grade UL-94 V0, Conforming to IS 9537 (Part 3) 1983 (Reaffirmed Year : 2017) with amendment no. 2 or latest with ISI mark. or PVC Casing & capping, ISI marked, white color, double locking, Resistant to Flame Propagation to grade UL-94 V0, as per IS:14927 Part 2 : 2001 (Reaffirmed Year : 2017 ) or latest, Standard Length: 2 meter, Size: 25x16mm. to be provided as and where required as per direction of consignee including PVC Circular Box and Ceiling rose if required with connection from running circuit as per direction of Consignee,stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. All materilas would be as per latest specification as issued from HQ/GRC time to time if available or latest IS and IE rules which is available.The cost includes supply of all materials to complete job. *Quantity per meter means-one meter conduit with 2 (two) meters Cu. cable of size 2.5 sq mm for phase & neutal and 1mtr of 2.5 Sq.mm PVC Cu. cable for earthing with Supply of PVC Circular Box and Ceiling rose as per direction of Consignee. " | — | — | — | 13,347.9 | |
| — | 30.00 | — | — | ||
| "Circuit/Sub-circuit wiring by PVC conduit/PVC casing capping wiring by 4 sq. mm, Single Core, Multistrand (56/0.3mm), Copper Conductor (flexible), Unsheathed, Flame Retardant Low Smoke and Halogen(FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked.Continuous Earthing with 4 sq. mm, Single Core, Multistrand (56/0.3mm), Copper Conductor (flexible), Unsheathed, Flame Retardant Low Smoke and Halogen(FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked Cable through PVC Conduit Pipe of Nominal Size 25mm and in the length of 3 mtrs, Socket ended (at one end ), medium mechanical stress, White Color, Resistant to Flame Propagation to grade UL-94 V0, Conforming to IS 9537 (Part 3) 1983 (Reaffirmed Year : 2017) with amendment no. 2 or latest with ISI mark. or PVC Casing & capping, ISI marked, white color, double locking, Resistant to Flame Propagation to grade UL-94 V0, as per IS:14927 Part 2 : 2001 (Reaffirmed Year : 2017 ) or latest, Standard Length: 2 meter, Size: 25x16mm. to be provided as and where required as per direction of consignee including PVC Circular Box and Ceiling rose if required with connection from running circuit as per direction of Consignee,stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. All materilas would be as per latest specification as issued from HQ/GRC time to time if available or latest IS and IE rules which is available.The cost includes supply of all materials to complete job. *Quantity per meter means-one meter conduit with 2 (two) meters Cu. cable of size 4 sq mm for phase & neutal and 1mtr of 4 Sq.mm PVC Cu. cable for earthing with Supply of PVC Circular Box and Ceiling rose as per direction of Consignee. " | — | — | — | 5,872.8 | |
| — | 10.00 | — | — | ||
| "Supply of 3 modular plate and metal/pvc box with 6A/16A twin socket Shutter type and 16 or 20A switch. All item will be modular type and separate (as per PCEE specification no.CEE/P/56/301 /MAINTENANCE, Dtd. 17/11/2022.) | — | — | — | 4,550 | |
| — | 10.00 | — | — | ||
| Fixing and commissioning of 3 modular plate and metal/pvc box with 6A/16A twin socket Shutter type and 16 or 20A switch. All item will be modular type and seperate. (Wiring will be covered under Shedule item No.2 as per site requirement). | — | — | — | 269.5 | |
| — | 10.00 | — | — | ||
| "Supply of modular PC Board consisting of 03 nos. switches with inbuilt LED indication, 03 nos. sockets and modular SP MCB 10A, 10kA, Type B- 01 No. with Stainless Steel 12M Box and all other accessories to complete job for concealed wiring. Specs: Modular Electrical Switch, 6 A, 230 V, SP, 1 Way, 1 Module, Unenclosed type as per Clause no.7.1.3, Method of Activation of switch shall be of Rocker type as per Clause no. 7.1.5, Switch shall be Flush type as per Clause no.7.1.6 and shall be installed as per Design A mentioned in the Clause no.7.1.7, Current carrying material as per Clause no. 22.5, with cover made of tough non-ignitable insulating material and bare of tough non-ignitable insulating material or of vitrified ceramic material, Conforming to IS:3854/1997 (reaffirmed 2017) with latest amendments and ISI mark and Modular type Socket outlet suitable for 3 pin plug, 6A, 230V, 2 Module, Shuttered (Operation of Shutter should be independant of Earthing Point), Cover made of tough Non-Ignitable insulating material, material of base -vitrified ceramic, Conforming to IS : 1293-2019, Amendment no. 1 or latest with ISI mark. with modular SP MCB 10A, 10kA, Type B- 01 No. ISI marked, rated voltage: 240V AC, conforming to IS/IEC 60898-1:2015 (Reaffirmed Year:2024) or latest, with rated short circuit current capacity 10KA, fixed unadjustable time current characteristics suitable for use in protection of industrial, commercial and domestic electrical installations. along with 12M stainless steel Box, moduler cover plate and Stainless Steel boxes and all other accessories including stainless steel fastener, Pin Type Terminal End Lugs to complete job as per specification attached or with latest amendment or specification issued from HQ/GRC if any time to time. | — | — | — | 14,399.9 | |
| — | 10.00 | — | — | ||
| Fixing and commissioning of modular PC Board consisting of 03 nos. switches with inbuilt LED indication, 03 nos. sockets and modular SP MCB 10A, 10kA, Type B- 01 No. with Stainless Steel 12M Box, moduler cover plate duly Concealed in wall surface including all other accessories to complete job with latest amendment or specification issued from HQ/GRC if any time to time, including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. (Wiring will be covered under Shedule item No. as per site requirement). | — | — | — | 221.9 | |
| — | 600.00 | — | — | ||
| Laying of cable / cables in under ground along the road through cable trench etc . as per standard drawing including necessary termination , connection and testing.Trenching and laying of U/G cables in any kind of soil trench of size minimum 0.40 mtr wide and 1 mtr deep covered with necessary bricks for protection of the cables including filling of space between brick and cable/cables with sand and refilling the trench with excavated soil, leveling up, and restoring the surface duly rammed. | — | — | — | 65,436 | |
| — | 100.00 | — | — | ||
| Laying of cable / cables across the road, track, drain etc through RCC/GI pipe confirming to IS standard of size 100mm or 150mm (or any suitable size as per field requirement based on the actual size of the cable) as per relevant specification and as per standard drawing with necessary termination, connections and testing .Cost also includes collection of cable/cables from Railway store if required.GI pipe will be supplied by contractor. | — | — | — | 24,965 | |
| — | 50.00 | — | — | ||
| Laying of cable/ cables on wall / structure through PVC casing pipe of size 4inches or 3inches with accessories or as per site requirement with suitable clamp / saddle/ fixtures etc with necessary termination, connection and testing as per standard drawing.Cost also includes collection of cable/cables from Railway store if required. | — | — | — | 3,750 | |
| — | 3.00 | — | — | ||
| Transportation of cables in rolls with or without wooden drums from the store of concerned SSEE or any store of kharagpur to the site of works. | — | — | — | 3,036.24 | |
| — | 100.00 | — | — | ||
| "Supply of HDPE pipe of size 110mm dia s per specification ISI mark IS no. 4984;2016 of reputed make,to complete job. Make-TATA/Jindal/Any ISI Approved. | — | — | — | 15,793 | |
| — | 100.00 | — | — | ||
| Erection and commissioning of HDPE pipe of size 110mm dia to complete job. | — | — | — | 1,579 | |
| — | 1.00 | — | — | ||
| "Supply and installation Tower ladder of Aluminium Tiltable Tower Ladder without bucket type having Reach height of 41-50Reach Height, (Foot) 41-50 Ladder Open Heigh tMin (Foot) 39-45, Ladder Closed Height Min (Foot) 18-24, Bottom Width (inch) 18-25, Platform Size (inch) 24x24, Number of Steps 41-50, Adjustable Height Yes, Load Capacity, (Kg) 120-150" | — | — | — | 1,39,322 | |
| — | 1.00 | — | — | ||
| Supply Fixing and commissioning of Energy meter digital LCD display, 3 Phase 4 wire, 415 V AC, primary current settable at site, secondary -/ 5 Amp, Aux:220V AC with display of active,reactive and apparent energy (KHW/KVAH/KVArh), complete set along with 3 Nos. Current transformer of 300/5 Amp or 400/5Amp. | — | — | — | 2,094.92 | |
| — | 1.00 | — | — | ||
| Fixing and commissioning of Energy meter digital LCD display, 3 Phase 4 wire, 415 V AC, primary current settable at site, secondary -/ 5 Amp, Aux:220V AC with display of active,reactive and apparent energy (KHW/KVAH/KVArh), complete set along with 3 Nos. Current transformer of 300/5 Amp or 400/5Amp. | — | — | — | 209.49 | |
| — | 3.00 | — | — | ||
| Supply , installation and commissioning of 2 Ton Green AC 5 Star (ISEER value Not less than 5.8) Inverter AC - Variable Speed Wall Mount Split AC details specification-BEE StarRating - 5, Type of Air conditioner - High wall split AC, Technology of AC - Inverter (Variable Speed), Coil Material- Copper, Eco-friendly refrigerant, Minimum length of copper pipe and suitable connecting electrical cable for Installation and commissioning- 5 meter, warranty on Machine 1 year, Warranty on Compressor- 10 Or higher including supply with Installation and Commissioning. | — | — | — | 1,77,375 | |
| — | 60.00 | — | — | ||
| Supply of suitable copper pipe for connecting of delivery to 1.5 TR split AC with insulation. | — | — | — | 14,700 | |
| — | 3.00 | — | — | ||
| "Supply of MCB DP 25 AMP Starter and socket plug with indicator Make: IS approved." | — | — | — | 1,627.11 | |
| — | 3.00 | — | — | ||
| "Fixing and commissioning of MCB DP 25 AMP Starter and socket plug with indicator. | — | — | — | 208.05 | |
| — | 50.00 | — | — | ||
| Supply o f Hot dipped Galvanized wire mesh cable trays size: 54mm/200mm with coupling kit and other accessories. It shall be manufactured with a longitudinal 'T- welded' safety edge All Accessories including couplers , mounting accessories (Mechanically tested & supplied by cable tray manufacturer must be used) are required of same finish as per site requirement. Trays should comply Standard EN ISO 14 61: at least 550 h of SST. The deflection of cable tray must be no more than 1/200th of the distance between two supports and tested in accordance with the standard IEC 61537. Wire-mesh cable trays must be designed with an optimum span of 1.5 m, considering the maximum carrying capacity authorized by the manufacturer. Assemblies with specific fire resistant properties must have an E30-E90 certificate. Rod-dia must be from 3.9mm to5.9mm for different sizes. | — | — | — | 64,000 | |
| — | 50.00 | — | — | ||
| Fixing and commissioning of Hot dipped Galvanized wire mesh cable trays size: 54mm/200mm with coupling kit and other accessories. | — | — | — | 2,406 | |
| — | — | — | 7,84,261.37 | ||
| on Sub-Total | GST @ 18% | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .