Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.5 LAccepted-AOC AT PO DAKRA KHALARI DIST RANCHI JHARKHAND PIN 829210 | RANCHI | JHARKHAND | 829210 | L1 | Accepted-AOC The L1 bidder is techno-commercially qualified. The quoted rate has been accepted by the Competent Authority, NK Area | |
| 2 | L2₹9.4 L+₹48,195.51 (5.40%)Rejected-Finance 00 C O LAKHAN LAL AGRAWAL RATU ROAD NEAR KABLISTHAN RANCHI JHARKHAND 834001 | RANCHI | JHARKHAND | 834001 | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical AT PO DAKRA DISTT RANCHI JHARKHAND 829210 | RANCHI | JHARKHAND | 829210 | - | Rejected-Technical Technically disqualified. |
Tender Value
₹9.6 L
EMD Value
₹12,100
Closing Date
6 May 2025, 5:00 pmClosed
SO EnM NK
GM OFFICE, NK AREA
Repair and maintenance of 3.3 KV Overhead Line for separate dedicated power supply from CRO Substation to Borehole 43 and tapping point to Borehole 24 under Churi UG Project, NK Area
2025_CCL_334557_1
GM (NK)/EnM/e-NIT/2025-26/20
Open Tender
Electrical and Maintenance Works
Item Rate
21 days
Churi Colliery, NK Area
As per NIT
2 documents required · 2 mandatory
₹12,100
17 Jun 2025
25 Apr 2025
7 May 2025
26 Apr 2025
6 May 2025
26 Apr 2025
26 Apr 2025 - 2 May 2025
Amount
Dismantling of pole / street light standard / strut embedded in cement concrete foundation etc as required.
Dismantling of over head lines comprising of copper / aluminium over head conductor, G.I. wire, cross arms, insulators etc as required
Erection of steel tubular or rail pole struct in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required. Above 11.00 meters and up to 13.00 meter.
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required
Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required
Supplying and erection of a set of cross bracing frame work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height, complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc (as per drawing) and painting with primer and finish paint as required
Supply and erection of 7/16 SWG G.I wire for continuity.
Supply of 8 SWG G.I. wire for rings of Cradle Guard
Erection of cradle guard as required.
Tree trimming / Branch cutting under Overhead lines.
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Providing and making steel pole collar with cement concrete (1 cement : 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc as required.
Transporting of pole from unit store to work site
Painting of poles including structures by red oxide and aluminum paint
Writing of respective HT/LT Feeder name/ Nos. voltage and poles with paint with color coding of respective HT/LT feeder and poles.
Total impact of GST for the purpose of CTC
M/S PRAVEEN KUMAR (BID ID -1150825)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .