Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹32,240
Closing Date
13 Dec 2024, 4:00 pmClosed
ED Budgam, KPDCL
ED Budgam, KPDCL
Creation of 200 KVA sub station for providing of power supply and street lighting to Court Complex Chadoora
2024_PDD_266093_2
EDB/89 of 2024-25
Open Tender
Electrical and Maintenance Works
Turn-key
30 days
ED Budgam, KPDCL
As per SBD
7 documents required · 7 mandatory
₹1,000
Executive Engineer, ED Budgam, KPDCL
₹32,240
18 Dec 2024
7 Dec 2024
14 Dec 2024
7 Dec 2024
13 Dec 2024
8 Dec 2024
7 Dec 2024 - 8 Dec 2024
Amount
Work items identified;
Supply , installation, testing and commisioning of 200 kVA ,11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound , and with LV Cable Box having detachable Aluminium Gland plate 11/0.433KV, 3-phase(EE Level-II) complete in all respect as per Standards.
Supply, installation, testing and commisioning of 9 mtr (410 SP-33) long Steel Tubular Poles complete with base plate(350x350x5mm), top cap, Earthing Channel(75x40x6mm) including digging of pit positioning etc, complete in all respect as per Standards.
Supply, laying, stringing, tensioning, binding of 50 Sqmm ACSR Conductor complete in all respects as per standards.
Supply,Carraige upto site and fixing of GI V cross-arm with top Bracket including clamp duly fabricated as per site requirement including clamps(50x8 mm), GI Nuts & Bolts,washers etc complete in all respects as per standards.
Supply,Carraige upto site, fixing and installation of GI Channels of different sizes including clamps and braces.
Supply,Carraige upto site,Installation,testing and Commissioning of 11kV Polymeric composite Pin Insulators 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm complete in all respects as per standards.
Supply and fixing of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6) mm, nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete in all respects as per standards.
Supply,Carraige upto site,Installation,testing and Commissioning of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm complete in all respects as per standards.
Supply, Carraige upto site, installation, testing and Commissioning of Gapless Surge Arrestor 9 kV, 10 kA, LA with polymer housing, Stn. Type complete in all respects as per standards.
Supply, Carraige upto site, installation, testing and Commissioning of 11 kV G.O AB Switch 3-phase, 3 pole 200-Amp, vertical Type with fittings complete in all respects as per standards.
Supply, Carraige upto site, installation, testing and Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A complete in all respects as per standards.
Supply, Carraige upto site, laying, stringing, tensioning, binding of 185mm² (2Ckt )1.1kV Grade, XLPE Insulated Stranded Conductor FRLS type cable complete in all respects as per standards.
Supply,Carraige upto site, fixing of Aluminium Thimbles of size 240/185 Sqmm.
Supply,Carraige upto site, fixing and Commissioning of Aluminium Solderless Clamps of size 240/185 Sqmm.
Supply, Carraige upto site, installation, testing and Commissioning of LT Distribution Box for 200 kVA DTR with 315 Amp MCCB 3P 25 kA for incomer & 160 Amp MCCB 3P 16 kA 3 No.s for Outgoing Circuits.complete in all respects as per standards.
Earthing of substation-Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 25 mmx3 mm, for connection of transformer body,G.O set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover complete in all respects as per standards.
Cement bottoming 1:2:4 mix as per Standards 0.5cum/0.45 cum pole comlete in all respects.
Earthing of steel tubular poles complete by GI pipe 40mm or GI rod 20mm 3.0 mtr long through GI strip 25x3 as per standards.
Painting of Poles with one coat of Red Oxide and two coats of alimunium paint to give uniform shine.
Supply and fixing of GI barbed wire Anti climbind Device with clamps complete in all respects as per Standards
Supply and fixing of danger plates with clamps complete in all respects as per Standards
SITC of 8.0 mtr Long GI (65 micron DFT single dip) Octogonal poles uniformally tappered with thickness of 3mm with bottom/top Dia of 155 mm x 70mm & base plate of 260x260x16mm/pcd 250 mm provided with proper door opened gear box for connections on the bottom side with G.I. Foundation Bolts (J Type) M20x700 mm long (Set of 4 no.’s per pole)
Laying of RCC foundation for 8.0 mtr. Long Octagonal poles including proper curing. 0.585mX0.585mX1.0m (RCC with concrete ratio 1:1.5:3 with minimum 8 Nos. of 12 mm dia longitudinal MS reinforcement rods with rings of 8 mm dia not more than 200 mm C.C for fixing the pole).
Earthing of Octagonal Pole Complete by GI Pipe 40 mm or GI Rod 20mm 3 mtr long through GI Strip (25x3)mm
SITC of Pre fabricate galvanized Two way top bracket (1000mm long with 48.3 OD GI Pipe) to be fitted on top of Octogonal pole for holding lighting
SITC of DK thermoplastic cable Junction/ Termination T boxes 8"x10"of class IP55/IP65 fitted with two 2-5 Amp MCB strip,4-way terminal block / connectors Incl. copper lugs, Clamps ,nut & bolts washers etc (Hansel or equivalent make) or poles with two way type bracket to be fitted properly inside the door opened gear box provided on the bottom side of the pole.
SITC120 Watt LED Luminaries of IP 67 protection
Surge Protector for the 120 watt LED type lighting fixture complete.
3X1.5 mm 2 PVC insulated multistrand flexible copper wire for service connections from connection plate to the LED luminary individual circuit including loop & earthings laid properly.
HDPE pipe 50 mm O/D and inner Dia 38 mm including trench excavation in hard soil (0.3x0.45x1000m) for laying of 25/16 sq mm Almunium armoured cable . The job further inludes refilling back the same and removal of surplus excavated material to an appropriate place.
SITC LT 25 mm² 4 core Aluminium XLPE Armoured cable to be carried through conduit/pipe U/G or A/G only in case of site constrains excluding cost of pipe & trench excavation. The cable shall include end termination lugs with its crimping /taping.
SITC LT 16 mm² 2 core Aluminium XLPE Armoured cable to be carried through conduit/pipe U/G or A/G only in case of site constrains excluding cost of pipe & trench excavation. The cable shall include end termination lugs with its crimping /taping.
SITC of Dust/rain/snow-proof canopy type mini-outdoor LT feeder panel of size 450X300mm with front door opening duly powdered colour coated with inbuilt 2No TPN 16-32 Amp MCCB,TPN busbars of same capacity installed on cement concrete block with 4 angle iron legs grouted in the cement concrete of termination of main 25sqmm cable and outgoing 25/16 sqmm cable circuits.
NOTE: 1.The rates quoted by the bidder for all the items shall be inclusive of GST/freight/insurance/storage/installation/testing and any other charges FOR Creation of 200 kVA sub station along with HT/LT Network and street lighting for court Complex Chadoora under the jurisdiction of ED Budgam, KPDCL.
JUNAID BASHIR WANI (BID ID -2283316)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .