| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.3 LAccepted-AOC | ₹16.3 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹16.4 L+₹15,120 (0.93%)Rejected-AOC | ₹16.4 L+₹15,120 (0.93%) | L2 | Rejected-AOC NOT being L1 |
| 3 | L3₹16.7 L+₹42,720 (2.62%)Rejected-AOC | ₹16.7 L+₹42,720 (2.62%) | L3 | Rejected-AOC NOT being L1 |
| 4 | L4₹17.0 L+₹73,560 (4.52%)Rejected-AOC T 3 HILL CREST APARTMENT BEHIND AMBABAI TEMPLE VASCO DA GAMA GOA 403 802 | VASCO DA GAMA | SOUTH GOA | GOA | 403802 | ₹17.0 L+₹73,560 (4.52%) | L4 | Rejected-AOC NOT being L1 |
| 5 | L5₹17.5 L+₹1.2 L (7.46%)Rejected-AOC | ₹17.5 L+₹1.2 L (7.46%) | L5 | Rejected-AOC NOT being L1 |
| Sl No | Description | Qty | Unit | MAYUR ELECTRIC SERVICES L1 | U k Enterprises L4 | Onkar Electricals L2 | BSK Construction L6 | PAUL REFRIGERATION L5 | S and G Constructions L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and fix of MCB distribution board, single door CRCA steel sheet enclosure powder coated, SPN 4 Way, 200 Amp rated shrouded copper bus bar for each phase, fully insulated and shrouded neutral bar, earth bar, wire set and cable ties for cable management, IP 43 and IK 09 protection with reversible metal door with provision for MCB/ Isolator/ RCCB/ RCBO as incomer and SP MCBs as outgoing etc complete all as specified and as directed.
Note: MCBs/ Isolator/ RCCB/ RCBO shall be measured and paid in separate items. | 144 | EACH | 650 ₹93,600 Lowest | 1,360 ₹1,95,840 | 800 ₹1,15,200 | 3,000 ₹4,32,000 | 1,500 ₹2,16,000 | 1,300 ₹1,87,200 |
| 2.00 | Supply and fix RCBOs for earth leakage, overload and short circuit protection, double pole, 300mA, 40Amps, 50Hz, 230v complete all as specified and as directed. | 144 | EACH | 2,200 ₹3,16,800 | 3,500 ₹5,04,000 | 1,000 ₹1,44,000 Lowest | 2,500 ₹3,60,000 | 4,300 ₹6,19,200 | 2,600 ₹3,74,400 |
| 3.00 | Supply and fix MCB, SP 32 Amps, 240V, 10 KA 'C' curve, current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed. | 288 | EACH | 135 ₹38,880 Lowest | 150 ₹43,200 | 200 ₹57,600 | 700 ₹2,01,600 | 240 ₹69,120 | 200 ₹57,600 |
| 4.00 | Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete including provision of one 20A, 240 volts single pole MCB complete all as specified as directed. | 144 | EACH | 1,100 ₹1,58,400 | 1,550 ₹2,23,200 | 1,500 ₹2,16,000 | 2,200 ₹3,16,800 | 1,700 ₹2,44,800 | 1,050 ₹1,51,200 Lowest |
| 5.00 | Material and labour for sub main wiring complete with and including 2 runs of 4 sqmm, single core FRLS, PVC insulated and unsheathed, multistranded, copper conductor cable, single core, 1100 Volts grade drawn through and including non metallic rigid white/ ivory colour PVC casing capping of suitable size including accessories etc as required and fixed on walls and 1 runs of 4 sqmm FRLS, PVC multistranded copper conductor cable for earthing and connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge.
Note : 2 runs of 4 sqmm PVC insulated cable and 1 run of 4 sqmm cable and one run of PVC casing capping shall be measured as one unit length. | 3,000 | RUNNING METRE | 340 ₹10,20,000 | 245 ₹7,35,000 | 370 ₹11,10,000 | 260 ₹7,80,000 | 200 ₹6,00,000 Lowest | 300 ₹9,00,000 |
Tender Value
₹19.5 L
EMD Value
₹39,000
Closing Date
16 Apr 2026, 6:00 pmClosed
GE (I) (CG) GOA
Military Engineer Service, GE(I) CG Goa, HQ CG DHQ-11, Chicolna, PO Bogmalo, Goa-403 806
PROVISION OF DEFICIENT POWER POINT AT CERTAIN TYPE-II MARRIED ACCOMODATION AT TRV, CHICOLNA UNDER GE (I) (CG) GOA
2026_MES_757938_1
8632/GOA/E8
Open Tender
Civil Works
Item Rate
120 days
GE (I) (CG) GOA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (I) (CG) GOA
₹39,000
3 Jun 2026
26 Mar 2026
23 Apr 2026
26 Mar 2026
16 Apr 2026
9 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply and fix of MCB distribution board, single door CRCA steel sheet enclosure powder coated, SPN 4 Way, 200 Amp rated shrouded copper bus bar for each phase, fully insulated and shrouded neutral bar, earth bar, wire set and cable ties for cable management, IP 43 and IK 09 protection with reversible metal door with provision for MCB/ Isolator/ RCCB/ RCBO as incomer and SP MCBs as outgoing etc complete all as specified and as directed. Note: MCBs/ Isolator/ RCCB/ RCBO shall be measured and paid in separate items. | |||||
| 2Supply and fix RCBOs for earth leakage, overload and short circuit protection, double pole, 300mA, 40Amps, 50Hz, 230v complete all as specified and as directed. | |||||
| 3Supply and fix MCB, SP 32 Amps, 240V, 10 KA 'C' curve, current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed. | |||||
| 4Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete including provision of one 20A, 240 volts single pole MCB complete all as specified as directed. | |||||
| 5Material and labour for sub main wiring complete with and including 2 runs of 4 sqmm, single core FRLS, PVC insulated and unsheathed, multistranded, copper conductor cable, single core, 1100 Volts grade drawn through and including non metallic rigid white/ ivory colour PVC casing capping of suitable size including accessories etc as required and fixed on walls and 1 runs of 4 sqmm FRLS, PVC multistranded copper conductor cable for earthing and connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge. Note : 2 runs of 4 sqmm PVC insulated cable and 1 run of 4 sqmm cable and one run of PVC casing capping shall be measured as one unit length. | |||||
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
8632TENDERPAGES.pdf
Tender Documents • 0.67 MB
BOQ_848976.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .