Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹11.0 LAccepted-AOC C O S 1 ESS GEE COMPLEX NEAR J K BANK SONAWAR BAZAR B B CANTT SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L-1 | Accepted-AOC BEING L1 | |
| 2 | L-2₹13.4 L+₹1.6 L (13.6%)Rejected-Finance | L-2 | Rejected-Finance BEING L-2 | |
| 3 | L-3₹15.9 L+₹4.1 L (34.6%)Rejected-Finance R O KHOJA BAGH BARAMULLA JAMMU KASHMIR | BARAMULLA | BARAMULLA | JAMMU AND KASHMIR | 193103 | L-3 | Rejected-Finance BEING L-3 | |
| 4 | L-4₹18.9 L+₹7.1 L (60.1%)Rejected-Finance R O KHREW TEH PAMPORE DISTT PULWAMA PIN 191103 J K | PULWAMA | JAMMU AND KASHMIR | 191103 | L-4 | Rejected-Finance BEING L-4 | |
| 5 | Rejected-Technical RAWALPORA WANABAL PATI YAYIL POST OFFICE SANAT NAGAR SRINAGAR 190005 J K | SRINAGAR | JAMMU AND KASHMIR | 190005 | - | Rejected-Technical HAVING ADEQUATE WORKLOAD IN TERMS OF NOTE NO 1 OF NIT. Bidder Firm has already appealed to NHEA for anticipated rejection and NHEA has rejected the same vide HQ 134 WE letter no 80060/Gen/861 EWS/442/E8 dated 30 June 2023. |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
20 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 861 EWS
GE 861 EWS c/o 56 APO
REPAIR AND MAINTENANCE OF EXTERNAL ELECTRIC LOW TENSION DISTRIBUTION SYSTEM AT KHUNMOH UNDER GE 861 EWS
2023_MES_597495_1
GE 861 EWS-29/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 861 EWS
As per tender documents
7 documents required · 7 mandatory
₹500
GE 861 EWS
₹40,000
Yes
21 Jul 2023
22 May 2023
27 Jun 2023
22 May 2023
20 Jun 2023
6 Jun 2023
Amount
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation of poles/stay/cable etc including getting out in any type of soil, complete all as specified and directed.
Excavation in trenches beyond 1.5 m wide and n.exc. 3 m deep for foundation of poles/stay etc including getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in depth, complete all as specified and directed.
Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point, complete all as specified and directed.
Sand cushioning to cable with dry fine sand in trenches 8 cm below the cable and 15 cm above the cable after laying, complete all as specified and directed.
Bricks laid in trenches flat with width equal to length of brick for cable protection well burnt sub class 'B' laid across the cable complete all ad specified and directed.
Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Plain cement concrete 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Pin type insulator porcelain, vitreous, white/ brown or green insulators including one galvanized MS spindle, two galvanized iron washer, GI nut of size 100 mm height and 65mm dia 1100 volts grade incl dismantling of old unsv, complete all as specified and directed.
Shackle type insulators, porcelain, vitreous white/ brown or green including galvanised MS strips, bolt, nuts and washer of size 75mm height and 90mm dia, size of strap section 31x3mm and dia of 12 mm for working pressure 1100 volts grade incl dismantling of old unsv, complete all as specified and directed.
Rolling type insulators, porcelain, vitreous white/ brown or green including galvanised MS strips, bolt, nuts and washer and dia of 12 mm for working pressure 1100 volts grade incl dismantling of old unsv, complete all as specified and directed.
Continuous earth wire/guard cradle hexagonal/rectangular fabricated with 4mm dia galvanized mild steel, binding wire incl dismantling of old unsv complete all as specified and directed.
Aluminium conductors steel reinforced (ACSR) of any size for OH lines including stretching, binding wire, jumpers, line taps etc incl dismantling of old unsv, complete all as specified and directed.
Supply and fixing steel tubular swaged pole with cast iron base plate finial tapper plug, bolts nuts and screws and specified type 410-SP-31 (9 Mtr long) in truly vertical position 1.5 m length of pole above ground level shall be painted with two coats of synthetic enamel paint in strips of 30 cm width, black and yellow alternatively and painting with two coats of aluminum paint over a coat of red oxide primer on rest part of pole and its connected parts complete all as specified laying GI pipe light grade for cable protection and fixing to existing pole with flat iron clamp 25x3mm including nuts bolts and washers etc complete of 40mm dia including taking out old unserviceable pole, complete all as specified and directed.
Supply & fixing in repair of stay assembly complete with accessories as shown in electric plate No. 1 and including loop type insulator white brown or green with over all dimensions 65x90mm, clearance of hole 16mm, complete all as specified and directed. Note:- Earth work , PCC shall be measured and paid for separately.
Cross arms, bracings, supports, clamps and back plate fabricated from structural steel section including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shapes size as indicated or directed and inclusive of one primer coat, and one under coat and one finished coat of aluminium paint incl dismantling of old unsv, complete all as specified and directed.
Restretching only the ACSR conductor fixed on over head line pole and tightening the ACSR, taking down the conductor from insulators complete with auth sag and rewinding with insulators in proper position after tightening with new aluminium winding wire of dia 2mm, complete all as specified and directed.
Supply and laying in repairs GI tubing light grade 50mm dia with all fitting laid in trenches or fixed on wall along pole complete for protection of electric cable/strip, complete all as specified and directed.
Supply & fixing in replacement air termination, single pointed aluminium rod 12mm dia and 300mm long, including necessary fittings and fixtures, complete all as specified and directed.
Supply & fixing in repair aluminium strip 25x3mm, with saddles and fixing screws etc. for roof conductors and down conductors above ground, complete all as specified and directed.
Test point terminal block made of gun metal or phosphorus bronze, size 75x75x25mm drilled and screwed including 3 Nos, 8mm dia, 25mm long hexagonal head screw including taking down of old, complete all as specified and directed.
M&L for repair/replacement of earthing complete with galvanised cast iron earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground less than 3.0m deep below normal ground level as earth electrode with top edge of the earth plate not less than 2.25mtr below ground level using GI strip 32x6mm as earth continuity conductor connected to earth plate by means of welding, GI thimbles, nuts, bolts & washers all as directed including providing earth wire protection pipe GI light grade 40mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover with handle of angle iron frame of size 40 x 40 x 6mm in PCC 1:3:6 adequate quantity of charcoal dust and salt and kalmi shore all around the earth plate, earth work in any type of soil remaining surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 or directed by Engineer-in-charge and incl testing on completion. Note :- (i) Item of earthing includes cost of 7.5 m long GI strip of size 32x6mm with protection pipe of 40mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by (-) 9.0%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
M&L for repair/replacement of earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion, complete all as specified and directed. Note :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 40mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by (-) 9.0%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
S&F in repairs 1100 volt grade heavy duty XLPE cable with PVC insulated aluminium conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 25 Sqmm nominal cross section 3.5 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete all as specified and directed. Note- Earth work and protection work shall be measured and paid for separately under respective items of BOQ.
All as per item No. 25 above but cross sectional area 35 Sqmm 3.5 core complete all as specified and directed.
All as per item No. 25 above but cross sectional area 50 Sqmm 3.5 core complete all as specified and directed.
All as per item No. 25 above but cross sectional area 70 Sqmm 3.5 core complete all as specified and directed.
All as per item No. 25 above but cross sectional area 95 Sqmm 3.5 core complete all as specified and directed.
All as per item No. 25 above but cross sectional area 150 Sqmm 3.5 core complete all as specified and directed.
All as per item No. 25 above but cross sectional area 16 Sqmm 2 core complete all as specified and directed.
All as per item No. 25 above but cross sectional area 10 Sqmm 2 core complete all as specified and directed.
Taking out from trenches/poles/wall etc LT UG Cable PVC insulated sheathed with multistranded aluminium conductor armoured and relaying after fault rectification duly tested in trenches/Poles/Wall of LT UG Cable of any sizes including earth work, complete all as specified and directed.
Supply and fixing in repair 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 4.0 sqmm, complete all as specified and directed.
Supply and fixing in repair 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 6.0 sqmm, complete all as specified and directed.
Supply and fixing in repair 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10.0 sqmm, complete all as specified and directed.
Supply and fixing in repair 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 16.0 sqmm, complete all as specified and directed.
Supply & fixing in replacement of danger notice board 1.6mm thick M.S sheet, vitreous enameled white with letters, figures and conventional skull and bone in signal red colour and fixed with M.S clamps, bolts and nuts of approved size for LT 20x15cm size. by replacing the unserviceable one, complete all as specified and directed.
Supply & fixing in replacement of voltmeter 0-500 volts digital type including taking down old existing unsv, complete all as specified and directed.
Supply & fixing in replacement of Ammeter 0-400 Amps digital type including taking down old existing unsv, complete all as specified and directed.
Supply & fixing in replacement of indication lamp (RYB) including taking down old existing unsv, complete all as specified and directed.
Supply and fixing in repair 1.5 Sqmm three core PVC insulated flexible copper conductor wire for street/security light terminal box , complete all as specified and directed.
LED flood light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including taking down old existing unsv, complete all as specified and directed.
LED flood light 50 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including taking down old existing unsv, complete all as specified and directed.
LED flood light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including taking down old existing unsv, complete all as specified and directed.
LED light fitting 1x20 watt, 230V, 4 feet surface mounted box type indoor decorative T-5 LED betten integrated type complete with all accessories internally pre-wired and including fixing on wall/ceiling with suitable PVC round/square block-02 Nos including connecting up with twin core copper cable with suitable size including taking down old existing unsv, complete all as specified and directed.
M&L for cutting of tree branches from any height and type of trees in route or near to LT overhead line as per the direction of Engr-in-Charge and cleaning the site, complete all as specified and directed. Note: (a) The tree branches shall be 2mtr away from outer conductor of OH lines after cutting. (b) Any damage caused due to Contractor's labour will be rectified by the Contractor without any extra cost to Govt. (c) T&P such as ladder, rope, cutter, axes and other required tools shall be provided by the Contractor.
Supply & fixing in repair MCCB 4 pole, 415 volts adjustable type, 160 Amps with breaking capacity 35/36 KA, complete all as specified and directed.
Supply & fixing in repair MCCB 4 pole, 415 volts adjustable type, 200 Amps with breaking capacity 35/36 KA, complete all as specified and directed.
Supply & fixing in repair MCCB 4 pole, 415 volts adjustable type, 250 Amps with breaking capacity 35/36 KA, complete all as specified and directed.
Supply & fixing in repair MCCB 4 pole, 415 volts adjustable type, 350 Amps with breaking capacity 35/36 KA, complete all as specified and directed.
Supply & fixing in repair MCCB 4 pole, 415 volts adjustable type, 400 Amps with breaking capacity 35/36 KA, complete all as specified and directed.
Supply & fixing in repair MCCB 4 pole, 415 volts adjustable type, 63 Amps with breaking capacity 16 KA, complete all as specified and directed.
Supply & fixing in repair Change over switch Off load 415 volts TPN in sheet metal enclosure of capacity 200 Amps, complete all as specified and directed.
Supply & fixing in repair Change over switch Off load 415 volts TPN in sheet metal enclosure of capacity 100 Amps, complete all as specified and directed.
Supply & fixing in repair Change over switch Off load 415 volts TPN in sheet metal enclosure of capacity 63 Amps, complete all as specified and directed.
Supply & fixing in replacement of PVC line spacer of superior quality, 4 way, spiral type, complete all as directed.
Supply & fixing in replacement of junction box of size 300x300x250 mm made of MS Sheet 1.6mm thick, front door openable with fixing screw painting with two coats of synthetic enamel powder coated paint over a coat of red oxide including alumn bus bar 4 Nos of size 25x3mm mounted on epoxy based post insulators and drilled holes for connection including 1 No MCBs 06 amps incl magnetic lock system all as required and fixed to poles using MS strip of size 32x6mm and nuts & bolts of required size all as required at site or as directed.
M/S Hilal Builders
M/S HAMIDULLAH KHUROO
M/S SHEIKH FEROOZ AHMAD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .