Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 134 1 PURVI BAGH DELHI ROAD MEERUT | MEERUT | MEERUT | UTTAR PRADESH | Admitted-Finance |
| 2 | Admitted-Finance 2ND FLOOR SHOP NO 303 MARUTI PLAZA RONCHI BANGAR TOWNSHIP MATHURA | MATHURA | UTTAR PRADESH | 281001 | Admitted-Finance |
| 3 | Admitted-Finance 0 0 0 NEAR DAK BUNGLOW NH 1 A NH 1A UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | Admitted-Finance |
Tender Value
₹50 L
EMD Value
₹50,000
Closing Date
17 Sept 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EDC 2 MT
SE EDC 2 MT
TNO.50/EDC2MT/2025-26
2025_PVVNL_1069393_1
TNO.50/EDC2MT/2025-26
Open Tender
Electrical Works
Lump-sum
180 days
EDD-SARDHANA
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
SE EDC 2 MT
₹50,000
27 Sept 2025
28 Aug 2025
17 Sept 2025
28 Aug 2025
17 Sept 2025
28 Aug 2025
Amount
33 KV, 11 KV & LT Line work
Cartage of following material from store center Meerut to Site of work including loading & unloading at both ends maximum distance up to 50 Km. :– A) PCC Pole 11 mtr. long
B) PCC Pole 8.5 mtr. long
C) 11 KV V type X-arm
D) LT ABC Cable 3x95+1x70+1x16 sq.mm
E) LT ABC Cable 3x50+1x35+1x16 sq.mm
F) Stay Set Complete
G) 11 KV XLPE Cable of size 3x300, 3x185, 3x70 sq.mm
H) 11 KV Cable Jointing Kit 3x300, 3x185, 3x70 sq.mm (Indoor/Outdoor)
I) 33 kv Pin Insulator with Pin
J) 11 kv Pin Insulator with Pin
K) 11 kv Disc Insulator with Fitting
L) 33 kv V type X-arm
M) GI Wire 6/8/10 SWG
N) Earthing Rod Complete
O) ACSR Weasal Conductor
P) ACSR Rabbit Conductor
Q) ACSR Dog Conductor
R) LT Distribution Box
Errection PCC Pole 11 mtr long after digging a pit of size 1.6 mtr deep in all type of Soil including grouting of the pole with proper ramming after completion of work.(as per UPPCL Respo)
Errection PCC Pole 8.5 mtr long after digging a pit of size 1.6 mtr deep in all type of Soil including grouting of the pole with proper ramming after completion of work. (as per UPPCL Respo)
Fixing of 11 KV V type X-arm (as per UPPCL Respo)
Laying lifting stringing of XLPE cable of size 3x70, 3x185, 3x300 sq.mm. including binding & jumpering properly. (as per UPPCL Respo)
Making of Jointing Kit indor/outdoor for 11 KV 3x70, 3x185, 3x300 XLPE (as per UPPCL Respo)
Fixing 11 KV Pin Insulator (as per UPPCL Respo)
Fixing 11 KV Disc Insulator (as per UPPCL Respo)
Fixing of 33 KV Pin Insulator with fitting (as per UPPCL Respo)
Fixing of 33 KV X-arm V type (as per UPPCL Respo)
Laying lifting stringing of proper sagging of ACSR Weasel Conductor for 3 phase, 3 wire 11 KV line including binding & jumpering properly. (as per UPPCL Respo)
Laying lifting stringing of proper sagging of ACSR Rabbit Conductor for 3 phase, 3 wire 11 KV line including binding & jumpering properly.
Laying lifting stringing of proper sagging of ACSR Dog Conductor for 3 phase, 3 wire 11 KV line including binding & jumpering properly.
Laying lifting stringing of proper sagging of ABC Cable of Size 3x95+1x70+1x16 sq.mm and 3x50+1x35+1x16 sq.mm including binding & jumpering properly.
Fixing of Stay Set complete (as per UPPCL Respo)
Fixing of GI Wire 6/8/10 SWG (as per UPPCL Respo)
Earting of each 11 KV line pople & T/F properly after drive of electrodes if size 20mmx2500mm and connection the earthing point with GL wire.(as per UPPCL Respo)
Fixing of LT Distribution box (as per UPPCL Respo)
Grouting of Pole (as per UPPCL Respo)
Grouting of Stay as per respo
Providing & fixing of HDPE pipe PE-80, PN-6, DN-200 mm. dia pipe for laying of 11 KV 3x185 sq.mm. XLPE cable (as per direction of Supervising engineer)
Laying of 11 KV 3x185 sq.mm. XLPE cable with HDD (Trenchless method) including cable laying for road crossing (as per direction of Supervising engineer)
Providing & Fixing of GI Barbed Wire (as per direction of Supervising Engineer)
Providing and fixing Various E Bracket for 11 KV (as per direction of Supervising Engineer)
Providing and fixing Various E Bracket for 33 KV (as per direction of Supervising Engineer)
Providing and fixing Number Plate With Clamp and nut bolts (as per direction of Supervising Engineer)
Providing and fixing Danger Plate With Clamp and nut Bolts (as per direction of Supervising Engineer)
Providing and fixing Clamp for 33 KV "V" type cross arm (as per direction of Supervising Engineer)
Providing and fixing various type of 11 KV & LT Clamp with Nut & Bolt
Providing and fixing of GI Pipe 150 mm dia. (as per direction of Supervising Engineer)
Providing and fixing of Holding & PG Clamp (as per direction of Supervising Engineer)
Providing and fixing of Shackle insulator (as per direction of Supervising Engineer)
Providing and fixing of Loop Guard complete 3 phase (as per direction of Supervising Engineer)
Providing and fixing of LT Shackle strip with nut & bold (as per direction of Supervising Engineer)
Providing and fixing of Spacer LT-PVC (as per direction of Supervising Engineer)
Providing and fixing of LT Piercing connector (as per direction of Supervising Engineer)
Providing and fixing stone pad
Providing and fixing MS Angle of size 65x65x6 (as per direction of Supervising Engineer)
Providing and fixing Top Channel (as per direction of Supervising Engineer)
Providing and fixing Dropper Channel (as per direction of Supervising Engineer)
Providing and fixing of Nut, Bolt for shackle insulator (as per direction of Supervising Engineer)
Providing and fixing Bolt, Nuts and washer all size (as per direction of Supervising Engineer)
Dismantling of damaged pole (as per direction of Supervising Engineer)
SHIVAM ENTERPRISES (BID ID -5540862)
P&H Engineering (BID ID -5540706)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .