RequiredOEM Authorization Certificate Bid to RA enabled No Automatic External Defibrillator (AED) ( 1 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Product Configuration Clinical Purpose Automatic external defibrillator should be fully automated
Requiredusing biphasic technology as per manufacturer recommendations energy level (joules) to deliver shock energy
Requiredcomplying with latest guidelines of AHA and must be upgraded to any future changes. * 1/4 Display AED have an LCD screen that display text prompts & ECG on screen AED have an LCD screen that display text prompts & ECG on screen Alarms/Prompts: Must provide both visual and audible prompts on CPR complying with latest AHA guidelines. * Construction: Compact
Requiredlight weight
Requiredportable with easily identifiable ON/OFF switch and preferably with a handle to carry * IPX rating for dust & water protection: IP55 or better * Power Power Source: AED shall be battery operated * Battery: AED Battery shall be non rechargeable
Requireddisposable and easily replaceable battery. * Battery Life: Standby life of AED battery shall be of >= 4 years
Requiredsufficient for eight hours of monitoring or minimum 100 shocks * Accessories Disposable electrode pads: Adult Disposable Electrode Pads - 2 nos. and Paediatric Disposable electrode pads - 2 Nos. are to be supplied for each unit of AED. If the Buyer demands
RequiredSeller shall supply total 4 nos. of Disposable Electrode Pads suitable for Adult Paediatric patients as per the requirement of the Buyer. * Certification & Warranty Warranty of AED: 5 years
Required[With out provision of free replacement of Battery during warranty period] 5 years
Required[With out provision of free replacement of Battery during warranty period]
Required5 years
Required[With provision of free replacement of Battery during warranty period] Or higher Shelf life of Disposable electrode pad: Two Years (if unused) * 2/4 Operating Conditions & Certification Operating Temperature: 0 degree to 50 degree C * Operating Humidity: 12% to 90% RH
Requirednon condensing * Operating Altitude: 100 to 15000 ft or above * Certification US FDA approved US FDA approved * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.