| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹67.8 LAdmitted-Finance A 18 GR FLOOR SITA ESTATE AZIZ BAUGH MAHUL ROAD CHEMBUR E MUMBAI 400 074 | MUMBAI SUBURBAN | MAHARASHTRA | 400074 | ₹67.8 L | L1 | Admitted-Finance |
| 2 | L2₹75.1 L+₹7.3 L (10.8%)Admitted-Finance B 10 2 ADJACENT TO COLGATE CO MIDC AREA WALUJ AURANGABAD MAHARASHTRA 431136 | AURANGABAD | MAHARASHTRA | 431136 | ₹75.1 L+₹7.3 L (10.8%) | L2 | Admitted-Finance |
| 3 | L3₹76.7 L+₹9.0 L (13.2%)Admitted-Finance | ₹76.7 L+₹9.0 L (13.2%) | L3 | Admitted-Finance |
| 4 | L4₹81 L+₹13.2 L (19.5%)Admitted-Finance | ₹81 L+₹13.2 L (19.5%) | L4 | Admitted-Finance |
| 5 | L5₹82.5 L+₹14.7 L (21.7%)Admitted-Finance A54 BEACH QUEEN JUHU PARADISE COOP HOUSING SOC PLOT NO 35 BTPS NO II AZAD ROAD JUHU KOLIWADA SANTACRUZ WEST MUMBAI | ₹82.5 L+₹14.7 L (21.7%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Kalpaka Power Control L1 | UNITED GENSETS PVT LTD L2 | AVA POWER AND RENEWABLE LLP L5 | VIRTUSTECHNO L3 | ROOPLAXMI ELECTRICALS L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | DIESEL GENERATING SET (Radiator type) Supply, installation, testing and commissioning of : | 1 | Each | 66,60,500 ₹66,60,500 Lowest | 74,00,000 ₹74,00,000 | 81,41,472 ₹81,41,472 | 74,70,000 ₹74,70,000 | 74,07,998 ₹74,07,998 |
| 2.001010 KVA / 808 KW at 0.8 PF 415V, 3 Ph 50 Hz Diesel Generating Set 'mainly for Prime duty operations but to be selected for continuous operation including all accessories complete with: i) Rubber-in-shear vibration mounts ii) Starting battery, leads, charger panel, '1# Battery Charger consisting of Followings and any other accessories required to complete the package. Transformer, Rectifier, D.C.Ammeter, D.C. Voltmeter, Charge rate selector switch [TRICKLE/BOOST/OFF], Lamp for battery charging indication iii) Residential duty silencer with flanges, anti-vibration springs, mounting pads etc., iv) Flexible connections (horizontal & vertical) v) MS piping from day tank to engine vi) Radiator with all the necessary accessories. vi) Foundation bolts, etc., vii) Auto DG Synchronisation Kit and Auto Load dependent start stop system. viii) Acoustic Enclosure CPCB/MPCB approved. ix) All other components specified in the specification or as required to complete the job x)All necessary approvals required by submitting all relevant documents and drawings to all concerned authories and getting it approved and handing it over to the client good for running the DG without any issues are included in this contract Thermal Insulation:- Supply and laying of Exhaust pipes complete with: i) Thermal insulation with TF quality (thickness as required but min of 75mm thick) Vendors must confirm the same for its compliance and obtain all necessary approvals. And no separate payment shall be made of approvals. 'ii) Aluminium cladding(22g). iii) All powder coated M.S. support as required to support the DG exhaust pipe as per site condition (no separate payment shall be made for the supports including foundation as required) | ||||||||
| 3.00 | SITC of Exhaust Pipe -Class B MS pipe 350mm / 14" dia between Engine and Silencer inculding bends, Thermal insulation for 6" pipe ( 50mm thick cladding using 64 kg/m3 density mineral wool and Aluminium sheet wrapping), All M.S. support as required to support the DG exhaust pipe as per site condition (no separate payment shall be made for the supports) | 10 | m | 9,955 ₹99,550 | 5,000 ₹50,000 Lowest | 8,484 ₹84,840 | 18,500 ₹1,85,000 | 67,447 ₹6,74,470 |
| 4.00 | MS Steel Support for Exhaust piping | 30 | Kg | 150 ₹4,500 | 150 ₹4,500 | 156 ₹4,680 | 140 ₹4,200 | 138 ₹4,140 Lowest |
| 5.00NOTE : All the Statutory approvals from CPCB & MPCB, Electrical inspector or any other approvals related to DG commissioning are covered in scope of DG Vendor only. | ||||||||
| 6.00ELECTRICAL : | ||||||||
| 7.00DG AMF & Synchronisation Panels:- Supply, installation, testing and commissioning of DG power Panel including the AMF, Logic control & Synchronising (PLC based) with all the necessary components and accessories as specified and shown on drawing with all specification as required and mentioned in the specification. ' i) Main Aluminium busbars with bar type feeder connections' & all internal wiring with (FRLS wires)and connections. ii) Earthing all components,frame etc. to a common internal earth bar. iii) Painting all sheet metal works. iv) All accessories & supporting structure.v) Brass glands and crimpinglugs for sending and receiving ends.vi) All ammeters with C.T's and voltmeter and energy' meters with necessary fuses.vii) Panel components as specifiedviii) MS base frame.ix) All switch gear to have' short circuit levels as specified x ) Breakers 'a) Bus coupler breaker shall be 4P, EDO type, b) Incomer Breaker should be 3 P + Neutral Contactor, EDO type, c) Outgoing ACB Breakers should be MDO type. AMF logic and control panel 1# Neutral Contactor of suitable capacity 1# Load manager with the indicating parameters like KW,KVA,KVAR,F,P.F,V,A etc. 1# Set of Current Transformer of Suitable ratio of Class 1 Accuracy for metering 1# Electronic Hooter 1 Set of Push Buttons-HOOTER ACCEPT/FAULT CLEAR 1# Control Swich [ON/OFF-for DG manual control] 1# Mode Selector Switch [AUTO/MANUAL/TEST/OFF] '1 Set of Indicating lamps for 'Load On Set ', 'Load On Mains'etc. xi) Auto Synchronizing Panel, 1# Double Voltmeter, 0-500V ,1# Double Frequency Meter, 45-55 Hz,1# Synchroscope,2# Dark Lamps,1# Synchronising Auto/ManualSelector Switch,1# Synchronising ON/OFF Selector Switch,1# Auto Synchronizing Relay,1Set of Instrument Fuses as required 'Isolator (Bus coupler)( Fixed Type-30 KA) | ||||||||
| 8.00Cable Termination Making cable end terminations including brass compression glands and crimping type copper lugs for cable sizes mentioned below of aluminium or copper. | ||||||||
| 9.00 | 3.5 C 240 sqmm A2XFY | 6 | Each | 2,000 ₹12,000 Lowest | 9,000 ₹54,000 | 2,538 ₹15,228 | 2,500 ₹15,000 | 2,232 ₹13,392 |
Tender Value
₹82.7 L
EMD Value
₹1.7 L
Closing Date
9 Jun 2025, 3:00 pmClosed
Director,TMC
Office of Engineering Services, Second Floor, Khanolkar Shodhika, ACTREC Kharghar Node, Navi Mumbai - 410210
Supply , Installation , testing and commissioning of 1 No 1010 KVA DG for SSPCC building at ACTREC
2025_TMC_860325_1
ET-17/1010 KVA DG/2025
Open Tender
Electrical Works
Item Rate
150 days
ACTREC, Kharghar
As per Tender Document
2 documents required · 2 mandatory
₹0
₹1.7 L
ACTREC,Kharghar
11 Sept 2025
16 May 2025
10 Jun 2025
16 May 2025
9 Jun 2025
16 May 2025
16 May 2025 - 23 May 2025
26 May 2025
Amount
DIESEL GENERATING SET (Radiator type) Supply, installation, testing and commissioning of :
SITC of Exhaust Pipe -Class B MS pipe 350mm / 14" dia between Engine and Silencer inculding bends, Thermal insulation for 6" pipe ( 50mm thick cladding using 64 kg/m3 density mineral wool and Aluminium sheet wrapping), All M.S. support as required to support the DG exhaust pipe as per site condition (no separate payment shall be made for the supports)
MS Steel Support for Exhaust piping
NOTE : All the Statutory approvals from CPCB & MPCB, Electrical inspector or any other approvals related to DG commissioning are covered in scope of DG Vendor only.
ELECTRICAL :
Cable Termination Making cable end terminations including brass compression glands and crimping type copper lugs for cable sizes mentioned below of aluminium or copper.
3.5 C 240 sqmm A2XFY
UNITED GENSETS PVT LTD (BID ID -3224588)
VIRTUSTECHNO (BID ID -3223892)
ROOPLAXMI ELECTRICALS (BID ID -3223422)
AVA POWER AND RENEWABLE LLP (BID ID -3228223)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .