Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAccepted-AOC 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L1 | Accepted-AOC Being overall reasonable | |
| 2 | L2₹15.6 L+₹1.7 L (11.8%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹16.5 L+₹2.6 L (18.3%)Rejected-Finance FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹17.0 L+₹3.1 L (22.3%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹17.5 L+₹3.6 L (25.9%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
22 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (C) KIRKEE
GE (C) KIRKEE RANGE HILLS ROAD KIRKEE PUNE-411003
COMPREHENSIVE REPAIR MAINTENACE OF LT ELECTRIC DISTRIBUTION LINES PANELS AND ALLIED WORKS AT DUNKIRK LINE UNDER AGE EM I IN GE CENTRAL KIRKEE
2021_MES_470599_1
8500/E8 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (C) KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE (C) KIRKEE
₹40,000
Yes
21 Oct 2021
25 Aug 2021
23 Sept 2021
25 Aug 2021
22 Sept 2021
9 Sept 2021
25 Aug 2021 - 8 Sept 2021
60 days
Amount
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of pipes and getting out in soft / loose soil complete all as specified and directed By Engineer in charge.
Excavation in trenches n.exc. 1.5 mtr in wide and exc. 1.5 mtr but n. exc 3.0 m in depth and getting out in soft/disintegrated rock complete all as specified and directed By Engineer in charge.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed By Engineer in charge.
Removing of excavted material to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Material and Labour for Plain Cement concrete 1:3:6 type C-2, using 40 mm graded aggregates as in foundation for filling in, mass concrete for foundation of pole, rtransformer, panel board, stay, post top lantern, repairs to road cutting, drain, path etc complete all as specified and as directed by Engineer in charge.
Material and Labour for Plain Cement concrete 1:2:4 type B-1, using 20 mm graded aggregates as in coping of new pole/reconstruction old damaged copings etc, including necessary formwork complete all as specified and as directed by Engineer in charge.
Material and labour for sand cushioning to under ground cable/ at cable trenches, hand punning complete all as specified and directed by Engr-in-charge.
Material and Labour for brick protection with sub class 'B' brick for UG Cable complete all as specified and directed by Engr-in-charge.
Dismantling and taking out carefully old/unserviceable UG cable of any type, any size from trenches/Poles/Ducts/LT Panels after dismantling ends from OH conductors/MCCB/Joint boxes for relaying/refixing or carrying to store for Schedule of credit complete all as specified and as directed by Engineer in Charge.
Supply, Laying , jointing and fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT Panel board, 1100 Volts, heavy grade duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed complete all as specified and directed by Engineer in charge for following size:-
6 Sqmm 2 core
10 Sqmm 2 core
16 Sqmm 2 core
10 Sqmm 4 core
16 Sqmm 4 core
25 Sqmm 3.5 core
50 Sqmm 3.5 core
70 Sqmm 3.5 core
95 Sqmm 3.5 core
240 Sqmm 3.5 core
Supply and errect true vertical position steel tubular swaged poles complete with cast iron base plate, finial taper plug bolts, nuts and screws confirming to IS : 2713 and made out of structural steel tube confirming to IS : 1161 and painted internally with a coat of bituminous paint and externally one primer coat and one under coat and one finishing coat of Aluminium paint of Type 410 SP-31 (9 metre long) including taking out defective steel/wooden pole complete all as specified and as directed by Engineer in Charge.
Material and Labour for Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts,bolts,washers, welding, bending cold or hot, drilling holes for bolts,in any shape or sizes as indicated with and including one primer coat and two coats of alluminium paint complete all as specified and directed by Engineer in Charge.
Material and labour for ACSR Conductor including jointing with existing conductor and strining on LT pole and proper fastening topin/shackle insulators with aluminium binding wires and required jumpering connections complete all as specified and as directed by Engineer in Charge including taking down old unserviceable conductors of any type.
Supply and fix pin type porcelain, vitreous brown insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and directed by Engineer in Charge.
Supply and fix shackle type porcelain, vitreous white, brown or green insulator including galvanised mild steel straps, wahsers, insulator bolts, wahsers and nuts, height in 100 mm, dia 115 mm, for grade 1100 volts complete all as specified and directed by Engineer in Charge.
Supply and fix loop type insulator, porcelain vitreous brown of size 65X90mm and clearance hole 16mm complete all as specified and directed by Engineer in Charge.
Material and Labour for stay assembly using 16mm dia galvanized rod complete all as shown in electrical plate no 1 of SSR Part I including dismantling and taking down unserviceable one complete all as specified and directed by Engr-in-charge. (Note:- Clamps, loop insulator, earth work, PCC required for the subject work shall be measured and paid separately under relevant item of this BOQ)
Material and Labour for stay wire using galvanised steel strand of 7/3.15 mm complete with necessary binding including dismantling and taking down unserviceable one complete all as specified and as directed by Engineer in charge.
Supply and fix earth continuity wire using GI wire not less than 4mm dia on pole including dismantling and taking downunserviceable one complete all as specified and as directed by Engr-in-charge.
Material and labour for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3 meter long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300mm dia and 3 meter long using suitable mechanical drilling rig (for drilling near the specified location), connected with galvanised steel earthing leadof 25x4mm all as shown in Plate no 2, connected to the erthing test point, concrete pit in PCC 1:3:6 Type C2 with pit cover, funnel, wire mesh, 32mm dia light grade GI Tubing for protection of GI strip 25x4mm, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessay returning filling in and removal complete all as specified in SSR PArt I, including testing to achieve earth resistance value as per IS specification on completion complete all as specified and as directed by Engineer in Charge.
Material and labour for restraining of overhead ACSR conductor of any size of 4 wire 35-45 meter span on pole after disconnecting all jumpering connection and binding of insulators and refixing all jumpering connection and insulator binding with aluminium conductor by providing tools and plants required for the work complete all as specified & directed by Engineer in Charge.
Material and labour for restraining of overhead ACSR conductor of any size of 2 wire 35-45 meter span on pole after disconnecting all jumpering connection and binding of insulators and refixing all jumpering connection and insulator binding with aluminium conductor by providing tools and plants required for the work complete all as specified & directed by Engineer in Charge.
Material and labour for restraining of GI cradle guard hexagonal/rectangular of size 35-45 meter span on pole after disconnecting all bindings on cross arms and redoing all bindings by providing required tools and plants required for the work complete all as specified & directed by Engineer in Charge.
Material and labour for restraining GI earth wire of any size 35-45 meter span on pole after disconnecting all binding on cross arms and redoing all bindings by providing required tools and plants required for the work complete all as specified & directed by Engineer in Charge.
Material and Labpur for cutting / trimming of tree branches around 3 meter distance from conductors of HT overhead line of span upto 50 meters including removing of cut branches and cleaning of site complete all as directed by Engineer in Charge.
Material and Labour for cutting / trimming of tree branches around 3 meter distance from conductors of LT overhead line of span upto 40 meters including removing of cut branches and cleaning of site complete all as directed by Engineer in Charge.
Supply and Fix in replacement of MCCB of 4 pole 400 Amps with breaking capacity 25 KA with thermal and magnetic release complete all as specified and directed by Engr-in-charge.
Supply and Fix in replacement of MCCB of 4 pole 250 Amps with breaking capacity 25 KA with thermal and magnetic release complete all as specified and directed by Engr-in-charge.
Supply and Fix in replacement of MCCB of 4 pole 200 Amps with breaking capacity 25 KA with thermal and magnetic release complete all as specified and directed by Engr-in-charge.
Supply and Fix in replacement of MCCB of 4 pole 160 Amps with breaking capacity 25 KA with thermal and magnetic release complete all as specified and directed by Engr-in-charge.
Supply and Fix in replacement of MCCB of 4 pole 125 Amps with breaking capacity 25 KA with thermal and magnetic release complete all as specified and directed by Engr-in-charge.
Material and labour for providing electronic cable fault locator suitable for LT 1100 volts to find out fault of underground cable laid in various locations and marking locations of all faults on ground for repairs for cables of following sizes:- (Note:- UG Cable, excavation and earthwork, sand cushioning, brick cover, jointing kit etc required for the subject work shall be measured and paid under relevant items of this BOQ)
6 Sqmm to 16 Sqmm 2 core
10 Sqmm to 25 Sqmm 4 core
35 Sqmm to 50 Sqmm 3.5 core
70 Sqmm to 150 Sqmm 3.5 core
180 Sqmm to 300 Sqmm 3.5 core
Supplying, fixing, jointing and testing heat shrinkable Straight through joint, with and including jointing materials and necessary earth work suitable for 1100 V , XLPE LT cable of size10 sqmm to 16 sqmm , 2 core, complete all as specified and as directed by Engineer in charge.
All as per item Ser No 33.00 above but cable of size 10 Sqmm to 16Sqmm, 4core.
All as per item Ser No 33.00 above but cable of size 25 Sqmm to 50 Sqmm Sqmm, 3.5 core.
All as per item Ser No 33.00 above but cable of size 70 Sqmm to 150 Sqmm Sqmm, 3.5 core.
All as per item Ser No 33.00 above but cable of size 185 Sqmm to 300 Sqmm Sqmm, 3.5 core.
Supply and Fix LED driver suitable for 45 Watt LED security light complete all as specified and as directed by Engineer in Charge. Make- Crompton/HPL/Bajaj as approved by GE.
Supply and Fix LED driver suitable for 25 Watt LED security light complete all as specified and as directed by Engineer in Charge. Make- Crompton/HPL/Bajaj as approved by GE.
Supply and Fix LED driver suitable for 20/15 Watt LED security light complete all as specified and as directed by Engineer in Charge. Make- Crompton/HPL/Bajaj as approved by GE.
Supply and Fix LED security light fittings, 45 Watt with LED driver complete with bracket made of 25/32 mm GI Pipe, Light grade, clamps, nut, bolt and washers including taking down old defective street light of any type/size complete all as specified and as directed by Engineer in Charge. Make:- Halonix, Cat Part No. HLSLD 06 45W CWDLR or equivalent from list of make as approved by GE.
Supply and Fix LED Building security light fittings, 25 Watt with LED driver complete with bracket made of 25/32 mm GI Pipe, Light grade, clamps, nut, bolt and washers including taking down old defective street light of any type/size complete all as specified and as directed by Engineer in Charge. Make:- Halonix, Cat Part No. HLSLD 14 25W CWDL LWP or equivalent from list of make as approved by GE
Supply and Fix Surge protector suitable for 45 Watt LED security light complete all as specified and as directed by engineer in Charge. Make;- Crompton/HPL/Bajaj as approved by GE.
Supply and Fix Surge protector suitable for 25 Watt LED security light complete all as specified and as directed by engineer in Charge. Make;- Crompton/HPL/Bajaj as approved by GE.
Supply and fix in replacement PVC flexible cable, 1.5 Sqmm stranded copper conductor, twin core complete all as specified and as directed by Engineer in Charge.
Supply and fix in replacement Contactor Type ML-2 AC 220 Volts, for 20 Amp complete all as specified and as directed by Engineer in Charge. Make :-L&T/Legrand/C&S as approved by GE.
Supply and fix in replacement Street light timer dial type, maxi rex 4 QT, 230 Volts, 230 Amp complete all as specified and as directed by Engineer in Charge. Make :-L&T/Legrand/C&S as approved by GE.
Material and Labour for painting of steel pole, any type upto 7.5 meter height above ground level with two coat of aluminium paint complete with and including painting of cross arm/clamps etc complete all as specified and directed by Engineer in charge.
Material and Labour for painting of steel pole, any type upto 9.5 meter height above ground level with two coat of aluminium paint complete with and including painting of cross arm/clamps etc complete all as specified and directed by Engineer in charge.
Material and Labour for painting of Two pole structure upto 9.5 meter height above ground level with two coat of aluminium paint complete with and including painting of cross arm/clamps etc complete all as specified and directed by Engineer in charge.
Material and Labour for painting of Four pole structure upto 9.5 meter height above ground level with two coat of aluminium paint complete with and including painting of cross arm/clamps etc complete all as specified and directed by Engineer in charge.
Material and Labour for painting of Six pole structure upto 9.5 meter height above ground level with two coat of aluminium paint complete with and including painting of cross arm/clamps etc complete all as specified and directed by Engineer in charge.
Notes for item No-48.00 to 52.00 : Rate quoted by bidder shall be inclusive of following:- (a) Scraping out wornout old paint and preparing the surface smooth for applying for paint.
Material and Labour for numbering of HT/LT poles serially with letter/number size of width and height upto 40mm insitu with aluminium paint complete all as specified and as directed by Engineer in Charge.
Material and Labour for GI tubing, Light grade, 40mm bore, on with and including necessary clamps, nuts, bolts and washers, under road cross, ISI marked for cable protection complete all as specified and as directed by Engineer in Charge.
Material and Labour for GI tubing, Light grade, 50mm bore, on with and including necessary clamps, nuts, bolts and washers, under road cross, ISI marked for cable protection complete all as specified and as directed by Engineer in Charge.
Material and Labour for jumper connections of length upto 1.5m with existing size and gauge of ACSR, binding with existing conductors for LT OH lines including taking out unserviceable jumpers complete all as specified and as directed by Engineer in Charge.
Supply and Fix feeder pillar box with 400 amps change over switch-01 No, fixed inside, outdoor type weather proof, vermin proof, made out of 3mm thick CRCA sheet, front operated double door 60cmX60cmX45cm fabricated on angle iron frame 50X50X5mm grouted on ground in PCC 1:3:6 upto 45cm below ground level, 30cm ground clearance,opening for two incoming and one outgoing cable of size 240 sqmm connecting both incoming and outgoing cables with suitable size of cbale lugs etc complete all as specified and as directed by Engineer in charge.
Material and labour for danger notice plate 1.6mm thick MS sheet, vitreous enamelled whiote, with letters,figures and conventional skull and bone in signal red colour and fixed with MS clamps, bolts and nuts of approved size for LT 1100 volts, 20x15cm size including taking down old danger board complete all as specified and as directed by Engineer in charge.
Material and labour for danger notice plate 1.6mm thick MS sheet, vitreous enamelled whiote, with letters,figures and conventional skull and bone in signal red colour and fixed with MS clamps, bolts and nuts of approved size for HT 11000 volts, 25x20cm size including taking down old danger board complete all as specified and as directed by Engineer in charge.
Supply and Fix Cast Iron HT/LT cable route indicator, round shaped, 120mm dia, 8mm thick, duly embossed with MES HT/LT cable fixed on flat iron 25x3mm thick, 300mm long and grouted in PCC including taking down old iunserviceable Route indicatoe complete all as specified and as directed by Engineer in Charge. Note:- PCC required for the item shall be measured and paid separeately under relevant item of this BOQ.
Material and labour for PVC line separator, round shape, spiral type, suitable for 4 conductor, 1100 volt grade complete all as specified and as directed by Engineer in Charge.
SOURABH ENGINEERS
SKS Electricals
Mahindra Electric Stores
MANGAL ELECTRICAL STORES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .