| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.0 LAccepted-AOC C O DR UMASHANKAR SHARMA RANGIYA TINIALI NEAR RAIL GATE POST RANGIYA DIST KAMRUP ASSAM PIN 781354 | KAMRUP | ASSAM | 781354 | L1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L2₹39.7 L+₹2.7 L (7.39%)Rejected-Finance T50 H NO T 50 NANGLI RAJAPUR NIZAMUDDIN EAST NEAR ISBT SARAI KALE KHAN SOUTH DELHI SOUTH DELHI DELHI 110013 UDYAM DL 08 0028221 | SOUTH EAST DELHI | DELHI | 110013 | L2 | Rejected-Finance BEING L2 BIDDER |
Tender Value
₹40.5 L
EMD Value
₹81,000
Closing Date
26 Oct 2022, 6:00 pmClosed
GE RANGIA
GE Rangia C/O 99 APO Rangia
PROVISION OF SURFACE DRAINAGE AT CERTAIN LOCATION AND OTHER SANCTIONED WORKS AT HATTIGOR MILITARY STATION UNDER GE RANGIA
2022_MES_555404_1
8604/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
HATTIGARH
AS PER NIT
9 documents required · 9 mandatory
₹500
GE RANGIA
₹81,000
Yes
13 Dec 2022
30 Sept 2022
28 Oct 2022
30 Sept 2022
26 Oct 2022
14 Oct 2022
Amount
M&L for PCC (1:4:8) type D2 ( using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as per specified and as directed by Engineer-in-charge.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc. 6m mean radius in cement mortar 1:6, complete all as per specified and as directed by Engineer-in-charge.
M&L for brick work with sub-class `B' old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
M&L for hardcore of guage not exc. 63mm deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface of broken stone or boulders, complete all as per specified and as directed by Engineer-in-charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated or semi-corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as specified and as directed by Engineer-in-charge.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as specified and as directed by Engineer-in-charge.
S&F Mild Steel Plates for steel gates (plain or Chequered) channels, square cut or notched, forming holes, with riveted, bolted or welded attachment confirming to 410-W (Gde-E-250) quality-B complete all as specified and as directed by Engineer-in-charge.
S&F MS steel work in tubular trusses including special shaped washers etc., complete using ERW or induction butt welded tubes confirming to IS 1161- 1979 graded St 240, complete all as per specified and as directed by Engineer-in-charge.
M&L for 100 mm thick cement concrete type D-2, 1:4:8 (using 40 mm graded stone aggregate) in sub base in flooring/ hard standing, complete all as specified and as directed by Engineer-in-charge.
M&L for 50 mm thick Cement concrete type B2, 1:2:4 (using 20 mm graded stone aggregate) in sub base in flooring/ hard standing, complete all as specified and as directed by Engineer-in-charge.
S&F coloured non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles over 15 mm thick screed bed or bedding layers in CM 1:6 complete all as per specified and as directed by Engineer-in-charge.
S&F coloured non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles over 10 mm thick screed bed or bedding layers in CM 1:4 complete all as per specified and as directed by Engineer-in-charge.
S&F of Gl power coated snap grid frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 450 mm centre to centre and suspended from GI wire of 3mm dia and all as specified and as directed by Engineer-in-charge.
S&F 4mm thick Non asbestos fibre cement building board / E-board fixed to GI frame (snapgrid) of standard section as per manufacturers instructions fixed in ceiling flat or sloped complete all as specified and as directed by Engineer-in-charge.
M&L for Mild steel TMT bars 10 mm dia. and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as per specified and as directed by Engineer-in-charge.
M&L for mild steel TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips quality, complete all as per specified and as directed by Engineer-in-charge.
M&L for damp proof course to horizontal or vertical surfaces including necessary formwork in cement concrete (1:2:4) mix type B-0, 40 mm thick, complete all as per specified and as directed by Engineer-in-charge.
M&L for form work for side of pillars, posts, columns & similar works vertical or batter complete all as specified and as directed by Engineer-in-charge.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilivers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. Fair finished surface of concrete flat complete all as per specified and as directed by Engineer-in-charge.
M&L for Formwork to sides of concrete foundation, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter fair finished surface of concrete flat complete all as per specified and as directed by Engineer-in-charge.
M&L for Formwork to chullah hoods, chajjas, weather shades, corbels, water troughs and similar items including edges, fair finished surface of concrete flat complete all as per specified and as directed by Engineer-in-charge.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) including edges fair finished surface of concrete flat complete all as per specified and as directed by Engineer-in-charge.
M&L for RCC (nominal mix) type B-1, 1:2:4 (20 mm graded Agg) as in chajjas complete all as per specified and as directed by Engineer-in-charge.
M&L for reinforced cement concrete (nominal mix) type B-l, 1:2:4 (20 mm graded aggregate) as in footing, foundation, plinth beams, lintels etc., complete all as per specified and as directed by Engineer-in-charge.
M&L for RCC (nominal mix) type B-1, 1:2:4 (20 mm graded Agg) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies,canopies, deck slabs and in shelves complete all as per specified and as directed by Engineer-in-charge.
M&L for reinforced cement concrete (nominal mix) type B-l, 1:2:4 (20 mm graded aggregate) as in columns, pillars, piers, posts and struts etc, complete all as per specified and as directed by Engineer-in-charge.
M&L for reinforced cement concrete (nominal mix) type B-l, 1:2:4 (20 mm graded aggregate) as in lintel over 1.5m span, complete all as per specified and as directed by Engineer-in-charge.
M&L for 15 mm thick rendering on fair faces of brick work or concrete surface on external surfaces in cement mortar (1:4) and surface finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
M&L rendering 10mm thick on other than fair faces of brick work or on other side of lathing in cement mortar 1:6, surface to be finished fair & even without using extra cement, complete all as specified and as directed by Engineer-in-charge.
M&L 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in hard standing/plinth protections, finished even and smooth without using extra cement complete all as per specified and as directed by Engineer-in-charge.
M&L for preparing newly plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed by Engineer-in-charge.
M&L for steel ventilators with top hung shutter including hinges, steel peg stay, complete all as per specified and as directed by Engineer-in-charge.
M&L for steel windows with side hung shutter including projecting type hinges with steel handle and steel peg stay ,complete without glazing bars,dovetailed or welded, complete all as per specified and as directed by Engineer-in-charge.
M&L for steel windows without side hung shutter including projecting type hinges with steel handle and steel peg stay ,complete without glazing bars,dovetailed or welded, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparation of new steel or iron surface of any description and applying two coats of synthetic enamel paint over a coat of red oxide, primer over 10cm width or girth complete all as specified and as directed by Engineer-in-charge.
S&F Stainless steel wire cloth, 0.36 mm dia of wire and average width of aperture 1.40 mm and fixed with tinned stacks, or galvanized wire staples complete all as per specified and as directed by Engineer-in-charge.
M&L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as per specified and as directed by Engineer-in-charge.
S&F 3 mm thick sheet glass, ordinary quality in squares not exceeding 0.5 Sqm in each pane fixed with cut & mitred beads, complete all as specified and as directed by Engineer-in-charge.
M&L precast pre-polished cement concrete chequered tiles 300x300x25mm thick set jointed and pointed in with grey cement and pigment laid over and including 15 mm thick screed bed in CM 1:6 in floorings, complete all as per specified and as directed by Engineer-in-charge.
M&L for sand filling under floors or in foundations spreading and levelling in layers not exc. 25 cm thick including watering and consolidation, complete all as per specified and as directed by Engineer-in-charge.
M&L for 35mm thick 2nd class hard wood, plain, framed panelled shutters (any number of panels) with panels of timber flat on both side (feather edged) or of veneered particle board medium density, wood particle board with commercial face veneers etc., complete all as per specified and as directed by Engineer-in-charge.
M&L for 35 mm thick second class hardwood glazed and skeleton shutter for doors open rebated and prepared to receive glass, gauge etc. (without sash bar) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc. sizes of member as specified in SSR part I section & clause 8.24 (a), complete all as per specified and as directed by Engineer-in-charge.
S&F Pressed steel double door frame of size 60 mm x 125 mm for doors with one or more rebates including necessary fixing lugs ,hinges, lock strike plate etc,as specified,supplied & fixing in opening as per specification and drawing including filling of PCC (1:3:6) in 20 mm aggregates complete all as specified and as directed by the Engineer-in-charge.
S&F aluminium alloy 300 mm anodised sliding door bolts with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast - aluminium alloy, complete all as specified and as directed by Engineer-in-charge.
S&F 150 mm long extruded Aluminium alloy handles, fabricated type, anodised, complete all as per specified and as directed by Engineer-in-charge.
S&F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously untreated wood or wood based surfaces of any description, exceeding 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed by Engineer-in-charge.
Excavation in post holes (or similar holes) each n.exc 0.5cum in soft/loose soil and getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering and removing of surplus soil to a distance n.exc 50 meters and making good surface, complete all as per specified and as directed by Engineer-in-charge.
M&L for PCC 1:3:6 type C-2 (40mm graded stone aggregate) as in foundations, fillings and mass concrete complete all as per specified and as directed by Engineer-in-charge.
S&F Mild steel work in hand rails, wind ties, posts and struts in fencing screwed or welded to shape as directed, including all necessary drilling, bolting or riveting etc., and similar work confirming to Fe 410 - O or Fe 310 - O, complete all as per specified and as directed by Engineer-in-charge.
Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
M&L for preparing new plastered surfaces and applying two coats of cement base paint on surfaces of walls, complete all as specified and as directed by Engineer-in-charge.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
M&L for 100 mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregate) as in flooring/ hard standing, surface finished fair and even without using extra cement, complete all as specified and as directed by Engineer-in-charge.
M&L for Glass dividing strips, 38 x 3 mm thick and inserted in position to confirm to design, complete all as per specified and as directed by Engineer-in-charge.
Supply only chainlink MS galvanised fencing, mesh size 50mm square, dia of mesh wire 3.15mm, complete all as per specified and as directed by Engineer-in-charge.
Fixing only chainlink fencing incl line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc incl provision of binding wire complete all as specified and directed.
S&F Mild Steel Round Bar 10mm dia (Gde - I, IS-432) as in Stiffener to Chain Link Fencing including necessary cutting, bending, hoocking, bindingetc., complete all as specified and as directed.
S&F Mild steel screw bolts of 11 to 15 mm dia of neck (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and as directed by Engr-in-Charge.
M&L for preparation of new or previously untreated steel or iron surface of any description and applying two coats of synthetic enamel paint over a coat of red oxide, primer not exc. 10 cm complete all as specified and as directed by Engineer-in-charge.
M&L for Framed work as in doors or gates of any section (solid/hollow) with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other rivering, running rails and uides) and hanging; also fastening and fixing complete using Fe-290(Gde E-165) complete all as specified and as directed by Engineer-in-charge.
S&F mild steel, plain, black sheet 0.63mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc., complete all as specified and as directed by Engineer-in-charge.
M&L for cement concrete 1:2:4 type B-1, (using 20 mm graded aggregate) 40 mm thick as in pavement/ hard-standing, surface finished fair and even using extra cement complete all as specified and as directed by Engineer-in-charge.
Removing Excavated soils exceeding 250 M but not exceeding 500 M and depositing where directed at a level not exceeding 1.5 M above the starting point, complete all as specified and as directed by Engineer-in-charge.
M & L for cement concrete 1:2:4 type B1(using 20 mm graded crushed stone aggregate) as in surface channel of drain, benching & coping finished even and smooth with using extra cement, complete all as specified and as directed by Engineer-in-charge.
S&F Reinforced concrete pipes, 600mm dia class NP2, laid and jointed complete with collars, complete all as specified and as directed by Engineer-in-charge.
M&L for Reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in cover slab etc and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed by Engineer-in-charge.
M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and incl PVC casing capping sleeves and caps of adequate width and length with all accessories and fittings like bends . elbow crosses etc with PVC round block and PVC terminal boxes with 3.00mm thick plastic laminated sheet cover for mounting fittings etc like switches sockets and fan regulator incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly complete all as specified and as directed for one light point controlled by one switch, complete all as per specified and as directed by Engineer-in-Charge.
All as per serial item No. 68 above but for one ceiling/exhaust fan point controlled by one switch.
All as per serial item No. 68 abovee but for one 3 pin 5 Amps socket outlet on same board.
All as per serial item No. 68 above but for one 3 pin 5 Amps socket outlet on independent board.
All as per serial item No. 68 above but with 4 sqmm (nominal area) cable with 4.00 sq mm size copper earth continuity conductor of green colour for 15 A socket outlet on independent boards.
Supply and fix switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal, complete all as specified and as directed by Engineer-in-charge.
Supply and fix switch piano flush type, 6/5 Amps 240 volts single pole one way, complete all as specified and as directed by Engineer-in-charge.
Supply and fix socket outlet, 3 pin 6/5 Amps, flush type, complete all as specified and as directed by Engineer-in-charge.
Supply and fix switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal, complete all as specified and as directed by Engineer-in-charge.
Supply and fix ceiling rose surface backelite three terminals, PVC/polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge.
Supply and fix LED tube light fittings1 x 20 Watt, 220 V, AC decorative box type with driver holder including LED tube rodconnecting up with three core flexible copper conductor cable from ceiling rose to tube light fitting complete all as specified and as directed by Engineer-in-charge.
S&F buliding security light fittings 18 Watt LED New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP openning seperate driver compartment with IP65 protection and impact resistance of IK07 and including connection up with twine core twisted flexible copper conductor cable, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing ceiling fan having sweep size of 1200 mm, 240 volt, energy efficient, 3 blades, down rods, electronic regulator with inetrnal pre-wired including accessories such as hook, nuts, bolts, etc. min air delivery 210 CFM with service value 6.00 BEE. five star rated with brushless direct current motor (BLDC), complete all as per specified and as directed by Engineer-in-charge.
Supply and fix MCB SPN 240 Volts 6 to 32 Amps breaking capacity 10 KA rating, complete all as specified and as directed by Engineer-in-charge.
Supply and fix MCB SP 240 Volts 6 to 32 Amps breaking capacity 10 KA rating, complete all as specified and as directed by Engineer-in-charge.
Supply and fix sheet metal enclosure powder painted for MCB SPN 12 way DB with din rail and bus bar including making good to the disturbed surface matching with the existing complete all as specified and as directed by Engineer-in-charge.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge.
Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
Supply, fixing, testing and commissioning of 10 Sqmm, 2 Core XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100Volt grade complete all as specified and as directed by Engineer-in-charge.
S&F 32 mm High density polyethylene pipes (HDPE) of pressure rating 6 kgf/sqcm laid in trenches, complete all as per specified and as directed by Engineer-in-charge.
S&F building security light bracket made out of GI tubing 25 mm bore medium grade 1.20 Mtr long bend to required shape as in bracket for street light fittings fixed with two pair or MS flat iron 40mm x 5mm size and clamp of required lenght and shape with bolts nuts and washers suitable for steel tubular pole including painting of mild steel flat iron surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge.
S&F PVC rectangular block for mounting, DBs, etc. with 3mm thick plastic laminated sheet cover of size 300 x 250 x 50 mm deep complete all as specified and as directed by Engineer-in-charge.
Supply & laying GI pipe 40 mm bore light grade for protection of UG cable, complete all as specified and as directed by Engineer-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs), complete all as specified & testing on completion. NOTE:- (I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate.
S&F LED light fitting 1x9W /1X10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-charge.
Supply and fix sheet metal enclosure powder painted for MCB SPN 08 way DB with din rail and bus bar including making good to the disturbed surface matching with the existing complete all as specified and as directed by Engineer-in-charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
M/S MICROAPPS SOFTWARE PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .