| Sl No | Description | Qty | Unit | ARADHYAARYAN CONSTRUCTION PRIVATE LIMITED L1 | NEW HI TECH WORKS L2 |
|---|---|---|---|---|---|
| 1.00 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m in -All kinds of soil. | 1,450 | Sqm | 21.44 ₹31,088 Lowest | 30 ₹43,500 |
| 2.00 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge All kinds of soil | 2,198.53 | Cum | 333 ₹7,32,110.49 | 211 ₹4,63,889.83 Lowest |
| 3.00 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) | 143.86 | Cum | 6,666 ₹9,58,970.76 | 4,600 ₹6,61,756 Lowest |
| 4.00 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering - All work up to plinth level: 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) | 2.66 | Cum | 6,666 ₹17,731.56 | 4,000 ₹10,640 Lowest |
| 5.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | 1,648.2 | Cum | 90.33 ₹1,48,881.91 Lowest | 195 ₹3,21,399 |
| 6.00 | Supplying and filling in plinth with fine sand under floors, including watering, ramming, consolidating and dressing complete. | 135.56 | Cum | 333 ₹45,141.48 Lowest | 1,500 ₹2,03,340 |
| 7.00 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. | 124.96 | Sqm | 999 ₹1,24,835.04 | 750 ₹93,720 Lowest |
| 8.00 | Centering and shuttering in cluding strutting, propping etc. and removal of form for:Foundations, footings, bases of columns, etc. for mass concrete | 364.43 | Sqm | 333 ₹1,21,355.19 | 270 ₹98,396.1 Lowest |
| 9.00 | Centering and shuttering in cluding strutting, propping etc. and removal of form for Walls (any thickness) include attached pilasters, buttresses, plinth and string courses etc. | 1,000.02 | Sqm | 999 ₹9,99,019.98 | 280 ₹2,80,005.6 Lowest |
| 10.00 | Centering and shuttering in cluding strutting, propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers | 1,951.99 | Sqm | 333 ₹6,50,012.67 Lowest | 475 ₹9,27,195.25 |
Tender Value
₹9.7 Cr
EMD Value
₹19.5 L
Closing Date
19 Jan 2023, 2:00 pmClosed
Executive Engineer, Projects Div. JMC
Town Hall JMC
Construction of Library and Gymnasium Hall at Ambedkar Hall, Jammu
2023_HAUDD_201871_1
Fresh e-NIT 83(P) of 2022-23 of Projects Div. JMC
Open Tender
Civil Works
Item Rate
720 days
Jammu
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
Yes
Chief Accounts officer, JMC
₹19.5 L
Yes
Town Hall JMC
7 Feb 2023
7 Jan 2023
20 Jan 2023
7 Jan 2023
19 Jan 2023
7 Jan 2023
12 Jan 2023
Amount
Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m in -All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge All kinds of soil
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering - All work up to plinth level: 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with fine sand under floors, including watering, ramming, consolidating and dressing complete.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Centering and shuttering in cluding strutting, propping etc. and removal of form for:Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering in cluding strutting, propping etc. and removal of form for Walls (any thickness) include attached pilasters, buttresses, plinth and string courses etc.
Centering and shuttering in cluding strutting, propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering in cluding strutting, propping etc. and removal of form forColumns, Pillars, Piers, Abutments, Posts and Struts
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer- in - charge. Note: - Cement content considered in this item is @ 330 kg/ cum. Excess/ less cement used as per design mix is payable/ recoverable separately All works upto plinth level.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer- in - charge. Note: - Cement content considered in this item is @ 330 kg/ cum. Excess/ less cement used as per design mix is payable/ recoverable separately All works above plinth level and upto floor V level
Centering and shuttering in cluding strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering in cluding strutting, propping etc. and removal of form for: Stairs, (excluding landings) except spiral Staircases.
Centering and shuttering in cluding strutting, propping etc. and removal of form for: Edges of slabs and breaks in floors and walls under 20 cm wide
Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete
Providing & fixing GRC JALI (30mm Minimum thick) on external walls as per the architectural drawing including Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven storey height made with 40 mm dia M.S. tube 1.5 m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffoldings for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc complete as per directions and approval of Engineer-in-charge.
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand)
Providing and laying autoclaved aerated cement blocks masonry with150mm/ 230mm/ 300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for separately).
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in superstructure above plinth level upto floor V level in cement mortar 1:4 (1 Cement : 4 coarse sand ) and curing complete. The rate includes providing and placing in position 2 nos. 6 mm dia M.S bars at every third course of masonry work.
Random Rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with: Cement mortar 1:6 (1 Cement : 6 coarse sand)
6 mm cement plaster of mix:1:3 (1 cement : 3 fine sand)
Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ per lite respectively conforming to IS: 2547(Part - 1 & II) 1976, applied on hacked / uneven background such as bare brick/ block/ RCC work on walls and ceiling at all floors and locations, finished in smooth line and level etc. complete.
15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 coarse sand)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm)
Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications:Two or more coats applied @ 1.25 liter/10sqm over and including one coat of special primer applied @ 0.75liter /10sqm
Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour and shade Area of slab over 0.50 sqm
Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite Work
Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counters and similar location in marble/granite / stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate.
Chequerred precast cement concrete tiles 22mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing, cleaning and curing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand) . Light shade using white cement
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand)including grouting the joints with white cement and matching pigments etc. complete Size of tile 1000x1000 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of tile 1000x1000 mm
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown
Providing and laying machine cut, mirror polished, Italian Marble stone flooring laid in required pattern in linear portion of the building all complete as per architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 18 mm thick Italian Marble stone slab, Perlato, Rossoverona, Fire Red or Dark Emperadore etc.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60mm thickness, including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.60mm pressed, mild steel welded or rigidly fixed together by mechanical means, including M.S pressed butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile C Fixing with carbon steel galvanized dash fastener of required dia and size (to be paid for separately).
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
Providing and fixing carbon steel galvanized (minimum coating 5 micron)dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2) counter sunk head, comprising of 10 m dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete masonry etc. as per direction of Engineer-in-charge. 10x80 mm
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws (35 mm thick)
Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete. 200 mm weighing not less than 120 gms.
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 150x10 mm
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 100x10 mm
Providing and fixing bright finished brass handles with screws etc. complete: 75 mm
Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge.
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete
Providing and fixing to the inlet mouth of rain water pipe fixing cast iron grating 15 cm diameter and weighing not less than 440 grams
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 sand : 4 stone aggregate 10mm and down grade) including finishing with cement mortar 1:3 (1 cement : 3 sand) as per standard design : In 75x75mm deep chase
Providing and fixing tiled False Ceiling of specified materials of size 595x595mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms/sqm both side inclusive ) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200 x 600mm and secondary cross “T” of length 600mm and size 24x25 mm made of 0.30mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.30mm and laying false ceiling tiles of approved texture in the grid including, wherever, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27x37x25x1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.8 mm spaced at 1200mm center to center along size 85x30x0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white colour tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with waterproofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with with water proofing cement compound @ 0.253kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with waterproofing cement compound @ 0.126 kg/sqm . This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. c) IInd course of 20mm cement plaster 1:3 (1 cement: 3 sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. c) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of area. d) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.) (with 5 years service guarantee)
Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs,balconies, terraces etc consisting of following operations. a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs) c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineerin- charge. 23.7.1 With average thickness of 120mm and minimum thickness at khurra as 65 mm
Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in-Charge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.(Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevant Item*). (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35%, Light reflection internal 10 to 15%, light reflection external 10 to20%, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer -in- Charge.
Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:4:8 or leaner mix (i/c equivalent design mix)
Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge
Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. work
Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead : Of area of 3 sqm. and below
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 meters lead.
Dismantling tile work in floors and roofs lay in cement mortar including stacking material within 50 meters lead. For thickness of tiles 10 mm to 25 mm
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meters lead
Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 meters lead
Demolishing mud phaska in terracing and disposal of material within 50 meters lead
Dismantling and stacking within 50 meters lead, fencing posts or struts including all earth work and dismantling of concrete etc. in base of T or L iron or pipe
Dismantling C.I. or asbestos rain water pipes with fittings and clamps including stacking the material within 50 meters lead: 100 mm dia pipe
Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead
Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge
Installation Of Pit Puzzle Car Parking System /Automatic (6 Grid 3 Level Pit Puzzle Type Automatic car system,) Complete as per Specification
Preparation of sub grade by excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re- olling the sub grade and disposal of surplus earthwith lead upto 50 metres
Consolidation of sub grade with power road roller of 8 to 12 tonne capacity including making good the undulations etc. and re- olling the sub grade
Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineer-in-charge
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber,finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. Note: Cement content considered in M-30 is @ 340Kg/Cum. Excess/Less cement used as per design mix is payable, recoverable separately.Cement concrete prepared with batch mixing machine.
Providing and fixing in position pre-moulded joint filler in expansion joints.
Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade ‘A’ sealing compound.
Painting road surface marking with adequate nos of coats to give uniform finish with ready mixed road marking paint conforming to IS: 164, on bituminous surface in white/yellow shade, including cleaning the surface of all dirt, scales, oil, grease and foreign material etc. complete. New work (Two or more coats)
Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-in charge.(Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment). Overhead informatory road signage
Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge.
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Jockey Pump).Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325.M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.180 lpm at 75 m Head
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. It should be complete as per specifications & directions of Engineer-in-charge.4 x 25 sqmm ( 28 mm )
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. It should be complete as per specifications & directions of Engineer-in-charge.3.5 x 50 sqmm ( 35 mm )
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. It should be complete as per specifications & directions of Engineer-in-charge. 3 X 10 sq. mm (22mm)
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. 150 mm width x 50mm depth x 1.6 mm thickness.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supplying & laying one number XLPE insulated PVC sheathed Aluminium Conductor armoured UG cable of 1.1 KV grade Conforming to IS 7098/1988 with upto date ammendment of following size in the existing RCC/HUME/ METAL /GI /CI /Stoneware/DWC pipe/ masonary Open Duct/ cable tray/ open in air etc. as requred. 4 core, 25 sq.mm. Aluminium Armoured
Supplying & laying one number XLPE insulated PVC sheathed Aluminium Conductor armoured UG cable of 1.1 KV grade Conforming to IS 7098/1988 with upto date ammendment of following size in the existing RCC/HUME/ METAL /GI /CI /Stoneware/DWC pipe/ masonary Open Duct/ cable tray/ open in air etc. as requred. 3.5 core, 50 sq.mm. Aluminium Armoured
Supply and fixing in position 1 m wide Insulation mat made of elastomeric polymers Material (Class -A) of 415V grade as per IS 15642-2006 . Thickness of insulation mat shall be not less than 2 mm to withstand 1.1 KV dielectric strength AS PER IS 15652 : 2006. It should be complete as per specifications & directions of Engineer-in-charge.
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (For Underground) 200 mm. dia (wall thickness = 6.3 mm)
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (For Underground) 150 mm. Dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. (Plant Room piping/Vertical Riser/Downcomer/Floor) 25 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.(Plant Room piping/Vertical Riser/Downcomer/Floor) 32 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.(Plant Room piping/Vertical Riser/Downcomer/Floor) 40 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. (Plant Room piping/Vertical Riser/Downcomer/Floor) 50 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. (Plant Room piping/Vertical Riser/Downcomer/Floor) 65 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. (Plant Room piping/Vertical Riser/Downcomer/Floor) 80 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. (Plant Room piping/Vertical Riser/Downcomer/Floor) 100 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. Plant Room piping/Vertical Riser/Downcomer/Floor) 150 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. (Plant Room piping/Vertical Riser/Downcomer/Floor) 250 mm dia (wall thickness 6.3 mm)
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :50 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :80 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :100 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :150mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :200 mm dia
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80 mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150 mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :200 mm dia
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.150 mm dias
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 40 m
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun metal
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: 2 way-100 mm dia M.S. Pipe. (FOR UG TANK)
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: 4 way - 150 mm dia M.S. Pipe. (FOR UG TANK & EXTERNAL RING MAIN)
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Pendent Sprinkler
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Upright Sprinkler
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Horizontal side wall sprinkler
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 150mm dia
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 150mm dia
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 700 mm
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1000 mm
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1200 mm
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1500 mm
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
Providing and fixing standard fireman's axe with heavy insulated rubber handle conforming to IS: 926 complete.
Providing and fixing hose BOX of size 900mmx2100mm made of 16 gause thick MS sheet with 4 mm thick frant glass doors in front painted "FIRE" in red paint i/c recessary locking /Key arrangement shall be painted with one coat of primer & two coat of finished stove enameled post office red colour paint .
Providing and fixing hose cabinet of size 750mmX600X250mm made of 16 gause thick MS sheet with 4 mm thick float glass doors in front painted "FIRE" in red paint i/c recessary locking arrangement suitable to accommodate external hydrant with butterfly valve 2 nos. 15 mtr. long hose pipe. 1 no. brach pipe mounted on wall or raised brick platform & duly painted with post office red externally and white internally with synthetic enamel paint complete in all respects for external hydrant.
Supplying, installing, testing and commissioning of pressure vessel for pressurization of fire system complete with valves at outlet / drain to operate as per operating sequences including 25 mm dia drain valve, air release valve with stop cock on the top, outside with one coat of primer & two coats of synthetic enamel paint of approved shade complete as required to operate commonly main fire pump, sprinkler pump & jockey pump at drop of pressure, automatically at required pressure setting. Complete as per manufacturer's specifications & as directed by Engineer- in-charge. working pressure:- 15 kg/sqcm test pressure: 20 kg/sqcm
Providing, Fixing, testing and commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 8 Kg/cm2 and test pressure 16 Kg/cm2 to provide relief from stresses at pipe flanges. 200 mm dia
Providing, Fixing, testing and commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 8 Kg/cm2 and test pressure 16 Kg/cm2 to provide relief from stresses at pipe flanges. 150 mm dia
Providing, Fixing, testing and commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 8 Kg/cm2 and test pressure 16 Kg/cm2 to provide relief from stresses at pipe flanges. 80 mm dia
Supply, fixing, testing and commissioning of screwed type brass/bronze lever operated ball valve of full flow with stainless steel ball (AISI 304 & spindle AISI 410) with setting & gland of superior quality having minimum working pressure of 16 kg/sqcm.25 mm Dia
Providing and fixing 25 mm dia inspection & testing assembly with gun metal ball valve, gun metal sight glass ,Reducer ,union, G.I PIPE. Connection to drain pipe/riser.
Providing & fixing cast iron 100 mm dia. Foot valve with nuts, bolts, 1.5 mm thick CAF gasket complete with all accessories (To be provided into UG Fire Water Tanks).
Providing, fixing water flow meter on test line complete with all accessories for flow indication, monitoring & testing of fire pumps with bypass arrangment including piping & bypass valves.150 mm dia
Supply and fixing of 4 Nos G.I round bottom FIRE BUCKET of 9 LTR. Capacity field with sand including proper supporting /mounting arrangement MS Angle Iron Frame painted by fire red colour over 2 coats of red oxide paint and written with white paint FIRE complete in all respects as per direction of Engineer Incharge.
Providing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire Extinguishers as described below: Concealed work, including cutting chases and making good the walls etc.Providing and fixing of 4.5 Kg. carbon-di-oxide type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase ingernal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming ro IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with internal charge.
Providing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire Extinguishers as described below: Concealed work, including cutting chases and making good the walls etc.Providing and fixing 6.0 Kg. ABC Powder type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with inernal charge.
Providing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire Extinguishers as described below: Concealed work, including cutting chases and making good the walls etc.Providing, fixing, testing and commissioning of 50 Litres (trolley mounted) Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked TAC approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and confoming to IS: 910.
Providing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire Extinguishers as described below: Concealed work, including cutting chases and making good the walls etc.Providing, fixing, testing and commissioning of CO2 type Fire Extinguisher of capacity 22.5 kg filled with Co2 Gas as per IS 15222 with controll discharge mechanism fitted with Hose, Horn & TROLLEY confirms to IS 2878 bearing ISI mark. Co2 Cylinder as per IS 7285.
Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate size including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc.
Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.
Providing and fixing white vitreous china flat back half stall urinal of size580x380x350mm with White P.V.C automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS:2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required: Single half stall urinal with 5 liter P.V.C automatic flushing cistern
Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps.
Providing and fixing white vitreous china water closet squatting pan (Indian type) Orissa pattern W.C. pan of size 580x440 mm
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
Providing and fixing Differecially abled toilets including Wash basin, Water closet,Cistern, grab bars & hand rails etc. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge. For physically handicap person consisting of; Wall mounted WC Pan-01 no. with built in Jet of Cera CAT no.S1046105 Concealed Cistern Cistern-01 no. of Cera CAT no. B1110108 & Knob B1120118 Soft Close Seat Cover -01 no of Cera CAT no.B1520106 Wall hung Wash Basin -01 no of Cera CAT no.S2040147 Spatula Single lever Cera CAT no F9030451 Wall mounted Grab bar 600 mm long - 2 nos of Cera CAT no.B2210106 Wall mounted Hinged hand rail 750 x 100-01 no Cera CAT no B2210108 Bottle Trap Cera CAT no F8060403 Waste Coupling Cera CAT no F8050101 Stainless soap dish Cera CAT no F5007106 Tissue paper holder Cera CAT no F5007110
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing toilet paper holder C.P. brass
Providing and fixing soil waste, Rain water and vent pipes 100 mm dia. Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing and fixing soil waste, Rain water and vent pipes 75 mm dia. Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing and fixing M.S. holder-bat clamps of approved design to sand cast iron/ centrifugally cast iron(spun) pipes embedded in and including cement concrete blocks 10x 10 x 10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls, etc. For 100mm dia pipe
Providing and fixing M.S. holder-bat clamps of approved design to sand cast iron/ centrifugally cast iron(spun) pipes embedded in and including cement concrete blocks 10x 10 x 10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls, etc. For 75mm dia pipe
Providing and fixing bend of required degree with access door insertion rubber washer 3mm thick, bolts and nuts complete100 mm diaHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing plain bend of required degree: 100 mm dia Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing single equal plain junction of required degree. 100 x 100 x 100mm Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing single unequal plain junction of required degree : 100x100x75 mm Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing terminal guard 100 mm Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe 100 mmSS 304 grade coupling with EPDM rubber gasket
Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe 75 mm SS 304 grade coupling with EPDM rubber gasket
Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron pipe of diameter: 100mm
Providing and fixing trap of self cleansing design with sand cast iron screwed down or hinged grating with or without vent, arm complete, including cost of cutting and making good the walls and floors. 100mm inlet and 100mm outlet Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing M.S. holder bat clamp of approved design to sand cast iron/ cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5 mm flat of specified shape, projecting 75 mm outside the wall surface and fixed on wall with 4nos, 6mm dia expansion hold fasteners, including drilling necessary holes in brick wall/ CC/RCC surface and the cost of bolts etc. The pipes shall be fixed to the already fixed brackets with the help of 30 mm x1.6 mm galvanised M.S. flats of specified shape and of total length 420 mm and shall be fixed with M.S. nuts, bolts, & washers of size 25x6 mm, one bolts on each side of the pipe. Total bracket length 580 mm of approved shape and design (for single 100 mm dia pipe)
Providing and fixing M.S. holder bat clamp of approved design to sand cast iron/ cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5 mm flat of specified shape, projecting 75 mm outside the wall surface and fixed on wall with 4nos, 6mm dia expansion hold fasteners, including drilling necessary holes in brick wall/ CC/RCC surface and the cost of bolts etc. The pipes shall be fixed to the already fixed brackets with the help of 30 mm x1.6 mm galvanised M.S. flats of specified shape and of total length 420 mm and shall be fixed with M.S. nuts, bolts, & washers of size 25x6 mm, one bolts on each side of the pipe. Total bracket length 810 mm of approved shape and design (for two 100 mm dia pipes)
Providing and fixing M.S. holder bat clamp of approved design to sand cast iron/ cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5 mm flat of specified shape, projecting 75 mm outside the wall surface and fixed on wall with 4nos, 6mm dia expansion hold fasteners, including drilling necessary holes in brick wall/ CC/RCC surface and the cost of bolts etc. The pipes shall be fixed to the already fixed brackets with the help of 30 mm x1.6 mm galvanised M.S. flats of specified shape and of total length 420 mm and shall be fixed with M.S. nuts, bolts, & washers of size 25x6 mm, one bolts on each side of the pipe. Total bracket length 1040 mm of approved shape and design (for three 100 mm dia pipes)
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with brackets of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg.
Providing,Fixing wall mounted Double Coat hook on door complete. (MAKE-1: JAQUAR, MODEL NO. COAT HOOK: AKP-CHR-35761P OR EQUIVALENT.)
Providing & fixing wall mounted 300mm Long SS Grab Bar including cutting & making good the walls. (MAKE-1: JAQUAR, MODEL NO. GRAB BAR: AKP-CHR-35701PS OR EQUIVALENT.)
Providibng and fixing straight type Macfit single body push fit type WC pan connector with factory supplied spring loaded seal guard of integral single mould sealing fins made of flexible EVA body, including bush/adaptor for use with C.I. Pipe as supplied with the pan connector.
Providing and fixing cast brass Floor cleanout plug with suitable insert keys for opening in brass cap, male threaded joint/reducer with G.I. socket caulked to Pipe/fittings of CI pipe including cost of lead joints etc. complete in all respect. 100 mm dia
Providing and fixing GI inlet fitting with maximum 3 inlets 32,40 or 50 mm size fabricated from 100 dia GI pipes and sockets,fixed to C.I. trap with Drip Seal joint and set in cement concrete as per standard drawing complete as directed by Engineer-incharge.
Providing and fixing SS Grating of 125 mm dia of approved quality and colour complete as per direction of engineer in charge. Circular Type 125 mm nominal dia with 25 mm waste hole
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing 15 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing 20 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing 25 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing 32 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing 40 mm nominal outer dia Pipes
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.:Internal work - Exposed on Wall 32 mm nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.:Internal work - Exposed on Wall 40 mm nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.:Internal work - Exposed on Wall 50 mm nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) 65 mm dia. nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) 80 mm dia. nominal bore
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 65mm nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :
Providing and fixing Thermoflex or Kaiflex thermal insulation tubing, a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including protection by wrapping with 24 gauge alumminium sheet with riveted screw joints all required accessories complete as per specification. 13 mm thick (Exposed Pipes) For 15 mm dia Pipe
Providing and fixing C.P. brass Short body bib cock of approved quality conforming to IS:8931 with flow rate 2.5 litre per minute at 3 bar: (MAKE-1: JAQUAR, MODEL NO. SHORT BODY BIB COCK: FLR-CHR-5037NG OR EQUIVALENT.) 15mm nominal bore
Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931
Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc. if required will be paid separately). 50 mm dia
Providing and laying D.I. specials of class K-12 suitable for push-on jointing as per IS : 9523 : Up to 600 mm dia
Providing push-on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket. 100 mm dia pipes
Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS : 8329 : 100 mm dia Ductile Iron Double Flanged
Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.
Making hole up to 20x20 cm and embedding pipes up to 150 mm diameter in masonry and filling with cement concrete 1:3:6 (1 cement : 3 coarse sand 6 graded stone aggregate 20 mm nominal size) including disposal of malba.
Disinfecting C.I. water mains by flushing with water containing bleaching powder @ 0.5 gms per litre of water and cleaning the same with fresh water, operation to be repeated three times including getting the sample of water from the disinfected main tested in the municipal laboratory. 100 mm diameter C.I. pipe
Butterfly valve (manual) with C.I body SS disc nitrile sheet & O ring & PN 16 Pressure rating as specified 100 mm nominal bore 80 mm dia.
Butterfly valve (manual) with C.I body SS disc nitrile sheet & O ring & PN 16 Pressure rating as specified 100 mm nominal bore 100 mm dia.
Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 16 rating as specified. 80 mm dia.
Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 16 rating as specified. 100 mm dia.
Providing & fixing CI `Y' Strainer (screwed/ flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flange/ unions nuts, bolts and washers complete as required. 65mm nominal bore
Providing and fixing M.S fabricated hot dipped galvanized coating puddle flange comprising of 600 mm dia long M.S class 'B' pipe (screwed end up to 50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of required size including cutting holes in centre of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cutout in shuttering during concrete casting of tank of following diameter. (Location: Underground / Overhead Tanks.) 25mm dia pipe, 600mm long with size of 250x250x6 mm MS plate
Providing and fixing M.S fabricated hot dipped galvanized coating puddle flange comprising of 600 mm dia long M.S class 'B' pipe (screwed end up to 50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of required size including cutting holes in centre of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cutout in shuttering during concrete casting of tank of following diameter. (Location: Underground / Overhead Tanks.) 32mm dia pipe, 600mm long with size of 250x250x6 mm MS plate
Providing and fixing M.S fabricated hot dipped galvanized coating puddle flange comprising of 600 mm dia long M.S class 'B' pipe (screwed end up to 50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of required size including cutting holes in centre of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cutout in shuttering during concrete casting of tank of following diameter. (Location: Underground / Overhead Tanks.) 40mm dia pipe, 600mm long with size of 300x300x6 mm MS plate
Providing and fixing M.S fabricated hot dipped galvanized coating puddle flange comprising of 600 mm dia long M.S class 'B' pipe (screwed end up to 50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of required size including cutting holes in centre of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cutout in shuttering during concrete casting of tank of following diameter. (Location: Underground / Overhead Tanks.) 50mm dia pipe, 600mm long with size of 350x350x6 mm MS plate
Providing and fixing M.S fabricated hot dipped galvanized coating puddle flange comprising of 600 mm dia long M.S class 'B' pipe (screwed end up to 50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of required size including cutting holes in centre of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cutout in shuttering during concrete casting of tank of following diameter. (Location: Underground / Overhead Tanks.) 65mm dia pipe, 600mm long with size of 350x350x6 mm MS plate
Providing and fixing M.S fabricated hot dipped galvanized coating puddle flange comprising of 600 mm dia long M.S class 'B' pipe (screwed end up to 50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of required size including cutting holes in centre of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cutout in shuttering during concrete casting of tank of following diameter. (Location: Underground / Overhead Tanks.) 80mm dia pipe, 600mm long with size of 400x400x6 mm MS plate
Providing and fixing M.S fabricated hot dipped galvanized coating puddle flange comprising of 600 mm dia long M.S class 'B' pipe (screwed end up to 50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of required size including cutting holes in centre of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cutout in shuttering during concrete casting of tank of following diameter. (Location: Underground / Overhead Tanks.) 150mm dia pipe, 600mm long with size of 450x450x6 mm MS plate
Providing and fixing motorised butterfly valve with float type sensors suitable for 240 volts with working pressure rating of not less than 6 kg/cm2 with control panel and sensors to open valve when water level is low in tanks and to close when water level is high in water tanks including necessary cables, conduits, upto junction box (upto 6 mt qty approx.) etc., complete. 32 mm dia
Providing and fixing water meter with direct reading dial in "KL" with all internal parts in gunmetal, strainer, flanged distance piece for easy removal in future, 100 mm dia Bourden type pressure guage and isolation cock including necessary test certificate for the meter. (For water supply metering from source). 80 mm dia
Providing and fixing water meter with direct reading dial in "KL" with all internal parts in gunmetal, strainer, flanged distance piece for easy removal in future, 100 mm dia Bourden type pressure guage and isolation cock including necessary test certificate for the meter. (For water supply metering from source). 32 mm dia
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) including bed concrete as per standard design All around S.W. pipe 150 mm diameter S.W. pipe
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) including bed concrete as per standard design All around S.W. pipe 200 mm diameter S.W. pipe
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) including bed concrete as per standard design All around S.W. pipe 250 mm diameter S.W. pipe
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : Upto haunches of S.W. pipe150 mm diameter S.W. pipe
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : Upto haunches of S.W. pipe 200 mm diameter S.W. pipe
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : Upto haunches of S.W. pipe 250 mm diameter S.W. pipe
Providing and fixing square- mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. 180 x 150 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 60 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Inside size 90x80 cm and 60 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes: Size 90 x 80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Size 120x90 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manholes Manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m
Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25 mm and over all minimum length 263mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing. including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality. HD – 20 Circular shape 560mm internal diameter
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250 mm diameter
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 350 to 450 mm diameter
Constructing brick masonry road gully chamber of specified size with common burnt clay(non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4coarse sand) including precast R.C.C. horizontal grating with frame complete as per standard design: Chamber size 50x45x60 cm including precast R.C.C grating with frame 500x450 mm horizontal grating
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as10 sqm on plan including disposal of excavated earth, leadupto50meterand lift upto 1.5m, as directed by Engineer-in-Charge. All kinds of soil
Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. Ordinary rock
Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. Hard rock (requiring blasting)
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Boring/ drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800(part 1), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire and running charges of all equipment tools plants and machineries required for the job, all complete as per direction of Engineer-in-charge upto 90 m depth below ground level.All types of soil 400 mm dia.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings and accessories etc all complete for all depths as per direction of Engineer-in-charge.150 mm nominal size dia.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well screen (RMS) pipe with ribs, conforming to IS: 12818, including hire and labour charges, fittings and accessories etc all complete for all depths as per direction of Engineerin-charge 150 mm nominal size dia.
Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/medium/coarse in required grading and sizes as per actual requirement all complete as per direction of Engineerin-charge.
Development to tube well in accordance with IS: 2800(part 1) and IS:11189 to establish maximum rate of usable water yield without sand content ( beyond permissible limit) with required capacity air compressor, running the compressor for required time till well is fully developed measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete including required hire & labour charges of air compressor tools & accessories, etc. all, as per direction of Engineer-in-charge
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe removable as per requirement all complete for bore well of : 150 mm dia
Providing and fixing M.S clamp of required dia to the top of casing/ housing pipe of tube well as per IS:2800 (part 1), including necessary bolts & nuts of required size complete: 150 mm clamp.
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS: 2800 (part 1) 150 mm dia
Butterfly valve (manual) with C.I body SS disc nitrile sheet & O ring & PN 16 Pressure rating as specified.80 mm dia.
Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 16 rating as specified.80 mm dia.
Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work)100 mm dia. nominal bore
Supply, Lowering, installation & testing of KSB make submersible pumping set with 10 HP motor 18 stage pump suitable for maximum capacity of 20 m3 hr. at 100 mtr. Head respectively. With Three Phase.
Providing & fixing cable 6 sq.mm. From submersible pump to panel board.
Providing & fixing Panel Board for submersible pump fitted with DOL starter ammeter, voltmeter single phase preventer standard/indo/cop make MCB of off switch push bottom duly wired and made out of 16/18 SWG sheet.
Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material: All kinds of soil.
Supplying and stacking at site. 53 mm to 22.4 mm size stone aggregate
Boring/ drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800(part 1), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire and running charges of all equipment tools plants and machineries required for the job, all complete as per direction of Engineer-in-charge upto 90 m depth below ground level. All types of soil 300 mm dia.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 6 way Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 8 way Double door
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40amps
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing following rating, double pole, single phase and neutral, 240 volts, residual current circuit breaker ( RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required. 63 amps
Supplying and fixing following rating, double pole, single phase and neutral, 240 volts, residual current circuit breaker ( RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required. 40amps
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. Group – C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group – C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor 2 X 16 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor 4 x 10 sq.mm + 2 x 6 sq.mm. earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor 4 x 16 sq.mm + 2 x 6 sq.mm. earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.Make:KEI,Worldcab,RR Kable,Bonton
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.Make:KEI,Worldcab,RR Kable,Bonton
Supplying and fixing of call bell / buzzer suitable for single phase,230 volt complete as required.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV antenna socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)
Supplying and drawing following pair 0.5 mm dia FRLS PVCinsulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 1 Pair
Supplying and drawing following pair 0.5 mm dia FRLS PVCinsulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
Supplying and drawing following pair 0.5 mm dia FRLS PVCinsulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.3 Pair
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. 1 run of cable
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 25 mm
Providing and fixing of lightning conductor finial, made of 25mm dia 300mm long, copper tube, having single prong at top, with 85mm dia 6 mm thick copper base plate including holes etc. complete as required.
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
Providing and fixing GI tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor as required. (for horizontal run).
Providing and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor as required. (For vertical run.)
Providing and fixing testing joint, made of 20mm x 3mm thick G.I. strip, 125mm long with 4 Nos. of G.I. bolts, nuts, check nuts and spring washers etc. complete as required.
Providing and laying G.I. tape, 32mm x 6mm thick, from earth electrode directly in ground as required.
Earthing with G.I. earth pipe 4.5 metre long, 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement etc. with charcoal or coke and salt complete as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe FRLSom earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 95 sq. mm and upto 185 sq. mm
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 70 sq. mm (38mm).
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 150 sq. mm (50mm).
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 300 sq. mm (70mm).
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 4 X 10 sq. mm (25mm).
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 4 X 16 sq. mm (28mm).
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 70 sq. mm (38mm)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Upto 35 sq. mm
Supply, laying and termination of the following sizes of 650/1100 volts grade PVC insulated copper conductor wires in existing conduits including end terminations with copper lugs. 3 x 2.5 sq.mm. Copper conductor ,PVC insulated PVC sheathed wires
Supplying and fixing in position of the following sizes of GI conduit buried in ground 600 mm deep including all accessories complete as required and as per specifications
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.100mm dia
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
Supplying, installation, testing & commissioning of addressable fire control module complete as required.
Supplying, installation, testing & commissioning of addressable phone control module complete as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.
Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
Supplying, installation, testing & commissioning of ceiling/wall mounted loud speaker, 3/1.5 Watt in ABS enclosure complete as required.
Supplying, installation, testing & commissioning of 6 inches dia, 2 watts, 70/100 volts ceiling speaker complete as required.
audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required.
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required speaker cable Single pair, 2-core, 1.5 sqmm
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required speaker cable Two pair, 2-core, 1.5 sqmm
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required speaker cable Three pair, 2-core, 1.5 sqmm
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required speaker cable Four pair, 2-core, 1.5 sqmm
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
Providing and fixing of non woven geotextile having thickness of 400 GSM, having minimum tear strength of 250 ASTM D4533, Width wise atleast 215 ASTM D4533 having puncture strength of 1550 plus asper ASTM D6241 Having elongation at Break of 57% plus as per ASTM D 4595 in two layers, made out of long fibres to hold the modules including cutting, sizing, Heat welding and needle punched for high porosity and proper percolation. Complete as per entire satisfaction of engineer-in-charge.
Supply & installation of Polymer based modules (Honeycomb design on each plate) made up of 100% recycled polypropylene capable of taking light vehicular movement upto atleast 30 tonnes / sqm with adequate backfilling & 4 small plates combination creating 3 spans inside the module. These modules are made from combination of large (683*410mm) and small (369*410mm) plates along with external locks. Each large plate should have atleast fourteen external locking slots inorder to give stability to tank. These tank should have optimum connection & block stability using double lock stability. Each single tank is made of four large and four small plates in case of single tank and 10 large & 12 small plates for triple tank. Capacity of single tank is (.683*.410*.450) equals to 0.126 CUM. Weight of each large plate should be atleast 1050 gms and each small plate should be atleast 550 gms.
Supply & installation of FRP based Microfilter with diameter of 750 mm and height 1000 mm having inlet of 6 inches and outlet of 6 inches with SS 304 mesh . Flow rate of microfilter should be atleast 40 - 45 KL / Hr. (FRP based RWH Filters should be GRIHA and SVAGRIHA Certified. The product should be registered under GRIHA Criterions 21 & 18 and SVAGRIHA Criterion 9. Certificate should be valid on the current date.)
Providing & fixing PN 16 butterfly valve including rubber gasket, flanges, nuts, bolts, washers & painting complete as required 80 mm dia.
Providing & fixing brass ball valve with CW617N grade brass with hard chrome plated ball inside PTFE (Teflon) seat & ring with chrome plated centre handle with female BSP threads tested to a pressure not less than 15 Kg / sqcm complete:in all respects 25 mm dia.
Providing & fixing brass ball valve with CW617N grade brass with hard chrome plated ball inside PTFE (Teflon) seat & ring with chrome plated centre handle with female BSP threads tested to a pressure not less than 15 Kg / sqcm complete:in all respects 50 mm dia.
Providing & fixing dual plate C.I. wafer type check valve tested to a pressure not less than 16 Kg/sqcm, including rubber gasket, flanges, union, nuts, bolts, washers & painting complete as required 80 mm dia.
Providing & fixing neoprene rubber double flanged rubber expansion joint (anti vibration bellow) of standard length as per manufacturer’s specifications. suitable for hydrostatic test pressure of 15 kg/sqcm including all necessary fittings i.e. rubber gasket, nuts, bolts, washers etc complete as required 80 mm dia.
Providing & fixing CI `Y' Strainer (screwed/ flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flange/ unions nuts, bolts and washers complete as required (on pump suction) 50 mm
Providing, Structural steel members in position at all levels and at all heights as specified in the drawings made out of standard MS sections consisting of MS angles, ISMC, ISMB conforming to IS 226/2062/800. Cost to include fabricating necessary Gusset Plates, Stiffener plates, Brackets, Bolts, Cleats, seating angles etc., to the required size, shape, alignment etc, as per the drawings. Cost to include welding of members using structural steel welding electrodes as per IS 814/816/817, testing as per IS 7307 (PART 1), necessary equipments, tools and tackles, staging, scaffolding required etc.,complete. including a coat of zinc chromate primer.
Providing and fixing Heavy class GI pipe (IS 1239 up to 150 mm dia. and IS3589 6.35 mm thickness above 150 mm dia.)header complete for pump suction / discharge manifold comprising of flanges, unions, check nuts, tee elbow etc. including all flanged connections as per drawing / site requirement. Supports from wall, floor and ceiling etc. Including dead end flanged connection complete as required. The header size shall also include tee connections with blank flanges for the future connections. two coats of synthetic enamel paint of approved shade as per IS : 2379 pipe colour code 80 mm dia
Irrigation hydropneumatic system One Set of pumps - (1 Working + 1 Standby) Water Flow Rate 50 LPM each Head 40 M RPM 2900.
Providing and fixing Heavy class GI pipe (IS 1239 up to 150 mm dia. and IS3589 6.35 mm thickness above 150 mm dia.)header complete for pump suction / discharge manifold comprising of flanges, unions, check nuts, tee elbow etc. including all flanged connections as per drawing / site requirement. Supports from wall, floor and ceiling etc. Including dead end flanged connection complete as required. The header size shall also include tee connections with blank flanges for the future connections. two coats of synthetic enamel paint of approved shade as per IS : 2379 pipe colour code 32 mm dia
Providing and fixing Heavy class GI pipe (IS 1239 up to 150 mm dia. and IS3589 6.35 mm thickness above 150 mm dia.)header complete for pump suction / discharge manifold comprising of flanges, unions, check nuts, tee elbow etc. including all flanged connections as per drawing / site requirement. Supports from wall, floor and ceiling etc. Including dead end flanged connection complete as required. The header size shall also include tee connections with blank flanges for the future connections. two coats of synthetic enamel paint of approved shade as per IS : 2379 pipe colour code 40 mm dia
Providing and fixing Heavy class GI pipe (IS 1239 up to 150 mm dia. and IS3589 6.35 mm thickness above 150 mm dia.)header complete for pump suction / discharge manifold comprising of flanges, unions, check nuts, tee elbow etc. including all flanged connections as per drawing / site requirement. Supports from wall, floor and ceiling etc. Including dead end flanged connection complete as required. The header size shall also include tee connections with blank flanges for the future connections. two coats of synthetic enamel paint of approved shade as per IS : 2379 pipe colour code 50 mm dia
Providing, Structural steel members in position at all levels and at all heights as specified in the drawings made out of standard MS sections consisting of MS angles, ISMC, ISMB conforming to IS 226/2062/800. Cost to include fabricating necessary Gusset Plates, Stiffener plates, Brackets, Bolts, Cleats, seating angles etc., to the required size, shape, alignment etc, as per the drawings. Cost to include welding of members using structural steel welding electrodes as per IS 814/816/817, testing as per IS 7307 (PART 1), necessary equipments, tools and tackles, staging, scaffolding required etc.,complete. including a coat of zinc chromate primer.
Supply of 4ft Linear Suspended/Surface diffused LED luminaire with system power [28W ± 5%], dimension should not be more than 1220 x 35 x 35mm should be available in 3000K/4000K/6000K color temperature operational voltage range of 90-265V, power factor > 0.9, THD < 10%, Inbuilt surge protection of 2.5 KV, Luminaire has Ingress protection of IP20 The luminaire should have minimum lumen output of 2200 lumens , CRI of >80 . The LEDs used have a life of 50000 burning hrs Lumen maintenance as per L70B10 with SDCM<=3 binning Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, IES, LM 79, LM 80, & TTC certificates will be provided from NABL accredited lab Certification: CE Certified, Design Patented/Registered, ROHS compliant, BIS Certification for Luminaires & Drivers. Make:- Klite Model Kl-3402/Regent/LT/Trilux
Supply, Installation, Testing and Commissioning of IP-40 rated 12W LED ceiling recessed bowl shaped back-lit panel light - Indoor luminaire with soft uniform Light distribution. Luminaire should be made of die-cast aluminium for better thermal management. High efficiency diffuser for glare free, uniform light distribution. CRI (Ra) : >80, SDCM≤ 3 to avoid color deviation , Led life should be atleast L70B10 50,000hrs High lumen output (Delivered) of at least 100lm/w.High PF constant current LED driver with surge and thermal protection with follwoing ratings Power Supply : Integrated Power Factor : >0.90 THD : <20% Surge Protection : 2.5KV Efficiency : >83%.Suitable for operation on 240V, 50Hz single phase ac supply, Operating Voltage : 90-265Vac Operating Temperature : -15°~+50°C.Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, IES, LM 79, LM 80, & TTC certificates will be provided from in house NABL accredited lab Certification: CE Certified, Design Patented/Registered, ROHS compliant, BIS Certification for Luminaires & Drivers Make: Klite Model-KL-3321/Regent/LT/Trilux
Supply, Installation, Testing and Commissioning of IP-65 rated 12W bulk head, Luminaire should be made of die cast aluminium with non corrosive SS fasteners.IK-08 Non yellowing UV stabilized translucent polycarbonate diffuser for glare free, uniform light distribution.Silicone gasket. Integral constant current power supply.CRI (Ra) : >80.Power Supply : Integral Power Factor : >0.95 THD : <10% Surge Protection : 2.5KV Efficiency : >85%. Frequency : 50-60Hz, Operating Voltage : 100-277Vac, Opaerating Temperature : -15°C~+50°C. Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, IES, LM 79, LM 80, & TTC certificates will be provided from in house NABL accredited lab Certification: CE Certified, Design Patented/Registered, ROHS compliant, BIS Certification for Luminaires & Drivers Make: Klite Model-KL-4074/Regent/LT/Trilux
Supply, Installation, Testing and Commissioning of Recessed 2x2 LED luminaire with system power [40W ± 5%], Available in 3000K/4000K/6000K color temperature, made of CRCA housing with aluminium front frame, must be equipped with Prismatic Acrylic diffuser UGR<21 . Powder coated with white epoxy polyester with operational voltage range of 180-240V, power factor > 0.95, THD < 10%, Inbuilt surge protection of 2.5 KV, Luminaire has Ingress protection of IP44 The luminaire should have minimum lumen output of 4000 ± 10% lumens , CRI of >80 . The LEDs used have a life of 50000 burning hrs Lumen maintenance as per L70B10 with SDCM<=3 binning Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, IES, LM 79, LM 80, & TTC certificates will be provided from in house NABL accredited lab. Certification: CE Certified, Design Patented/Registered, ROHS compliant, BIS Certification for Luminaires & Drivers Make: K-Lite Model KL-2288/Regent/LT/Treilux
Supply, Installation, Testing and Commissioning of IP-40 rated 18W LED ceiling recessed back-lit panel light - Indoor luminaire with soft uniform Light distribution. Luminaire should be made of die-cast aluminium for better thermal management. High efficiency diffuser for glare free, uniform light distribution. CRI (Ra) : >80, SDCM≤ 3 to avoid color deviation , Led life should be atleast L70B10 50,000hrs High lumen output (Delivered) of at least 100lm/w.High PF constant current LED driver with surge and thermal protection with follwoing ratings Power Supply : Integrated Power Factor : >0.90 THD : <20% Surge Protection : 2.5KV Efficiency : >83%.Suitable for operation on 240V, 50Hz single phase ac supply, Operating Voltage : 90-265Vac Operating Temperature : -15°~+50°C.Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161- /05/06/07, Surge : IEC 61000-4-5, IES, LM 79, LM 80, & TTC certificates will be provided from in house NABL accredited lab. Certification: CE Certified, Design Patented/Registered, ROHS compliant, BIS Certification for Luminaires & Drivers Make: Klite Model-KL-3322/Regent/LT/Trilux
Supply, Installation, Testing and Commissioning of Linear wall line n dot LED mirror light luminaire with system power [20W ± 5%], should be available in 3000K/4000K/6000K color temperature, minimum dimesnion 600 x 36 x 75, should be made up of High-Grade Aluminium with Die-cast Endcaps, Diffuser/Lens Material : Polycarbonate, Diffuser Finish : Vaccum Metalized Chrome Finish, UGR<12, operational voltage range of 90-265V, power factor > 0.9, THD < 10%, Inbuilt surge protection of 3 KV, Luminaire has Ingress protection of IP20. The luminaire should have minimum lumen output of 1000 lumens , CRI of >80 . The LEDs used have a life of 50000 burning hrs Lumen maintenance as per L70B10 with SDCM<=3 binning Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5,IES, LM 79, LM 80, & TTC certificates will be provided from NABL accredited lab.Certification: CE Certified, Design Patented/Registered, ROHS compliant, BIS Certification for Luminaires & Drivers Make: Klite Make:- KL-3315 /Regent/LT/Trilux
SITC Fresh air fan 250 mm
Supplying and fixing of RJ-11/RJ 45 (Both Twin socket)I/O Telephone outlet with shutters along with suitable base plate,key stone and surface/concealed back boxes of adequate module size, etc comple in all respect.
BUILDING PANEL INCOMER 1 No. 250amps 4P MCCB (25KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. 1 No.250 amps ATS METERING & INDICATION for each Incomer 1 set of R,Y,B phase indicating lamps Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA, harmonics upto 15th order & %THD) with RS-485 Port. Sets of 250/5A, CL-1, 15VA CTs for measuring. Sets of phase indicating lamp with 2A control MCBs. BUS-BAR325A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS Nos. 160 Amp TPN MCCB Nos. 100 Amp TPN MCCB 9 Nos. 63 Amp TPN MCB 6 Nos. 40 Amp DP MCB Building panel as described above.
4 Megapixel CMOS image sensor, H.264 & MJPEG dual-stream encoding, Max 20FPS@4MP (1920×1080) & 25/30FPS@960P(1280×960), 4mm Lens, Day/Night(ICR), Array IR Distance: 25m,(4MP HD IP SMART IR 25 Mtr Dome Camera with HD Lens)
4 Megapixel CMOS image sensor, H.264 & MJPEG dual-stream encoding, Max 20FPS@4MP (1920×1080) & 25/30FPS@960P(1280×960), 4mm Lens Day/Night(ICR), 2DNR, AWB, AGC, BLC,Max. IR Distance: 30m, 1 Array LED , IP66, Mobile Soft: CMOB,(4MP HD IP SMART IR 30 Mtr Bullet Camera with HD Lens)
Unmanaged Network Switches (24 port) Minimum 4/8 nos. 10/100/1000 BASE-T Ethernet Ports. Uplink port should have sufficient speed to avoid network congestion, preferably network should not be loaded more than 70% at any stage, fully IEEE 802.3 compliant,Protocols and compliances , The switch should provide all standard protocols and compliances AND Mounting Shall Be Rackmount, wall or desktop mounting options.
1 Mtr Cat 6 patch cord with 23 AWG suitable for Gigabit connection, it should be suitable to maintain the bending radius as per relevant code.
NVR , 64 Ch. with Upto 1080p Realtime Live View, H.264/MJPEG dual codec decoding, Max 96Mbps incoming bandwidth, Support 8 SATA HDD up to 32TB, 2 USB2.0, HDMI / VGA simulta video output, Support Multi-brand network cameras, ONVIF Version 2.0 conformance,
Supply, installation, testing and commissioning of 4TB HDD
Supply, installation, testing and commissioning of Video Managment Software.
Supply, installation, testing & commissioning of Client Workstation having Intel Core i5 orginal motherboard, 16 GB RAM, Video graphics card 2 GB Licensed Windows 8 Professional (64 bit) and 1 TB Hard Disk with Web camera,Printer and finger print scanner.
Supplying, Installation,Testing & Commissioning of 40 " LED Full HD TV Resolution 1920 x 1080 ,Contrast Ratio (Typical) 5000:1,Built-in Speaker (10W + 10W), Magic Clone (to USB), Auto Source Switching & Recovery, Lamp Error Detection, Super Clear Coating, Temperature Sensor, Plug and Play (DDC2B), Pivot Display, Clock Battery, PIP/PBP, Video Wall (10x10), Image Rotation, Button Lock, HDCP Support, Smart Scheduling, Smart F/W update, Built-In MagicInfo Premium-Swith Mounting Brackets as per Technical Specification complete in all respect.
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. 3 ½ C - 300 sq mm Aluminium
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. 3 ½ C - 150 sq mm Aluminium
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. 3 ½ C - 50 sq mm Aluminium
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. 4C- 16 sq mm Aluminium
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. 4C- 10 sq mm Aluminium
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. 4C- 6 sq mm Aluminium
Supply of following sizes XLPE insulated (Heavy duty) Aluminium or Copper conductor armoured cables suitable for working voltage upto and including 1100 Volts complete as required and as per specifications. 2 x 6 sq.mm
Termination of the following sizes of XLPE insulated Aluminium/ Copper conductor cable including providing terminal lugs,double compression gland , crimping the joints ,providing insulation tape,effecting terminal connections to the equipment complete as required. 2 x 6 sq,mm, Al conductor cable
Supply, fixing and laying of Heavy duty PVC pipes complete buried in floor with joints and other accessories as required. 63 mm dia, 2mm thick
Supply, erection, testing and commissioning of 6 M high Tubular pole as per Technical specifications and with following components :- Including supply and installation of 6 ways-20A connector & 6A MCB mounted on 6mm thick painted M.S/GI plate, insulated, and fixed inside the pole suitable for termination of armoured aluminium cable as required and wiring to Luminaries from the 6A MCB, with 3x2.5 sq.mm. PVC insulated copper, stranded conductor (P+N+PE) double sheathed wire including terminations. 6 meters high tubular pole with single arm of length 1.5 meter, smoothly curved making an angle of 10 deg to 15 deg with the horizontal plane complete as required.
Supply, Installation, Testing and Commissioning of post top LED luminaire with system power [45W ± 5%], indirect lighting i.e module should be set at the bottom of the luminiare and light should glide from the reflector to give glare free lighting experience , Should be available in 3000K/4000K/6000K color temperature, with minimum dimension Ø590 x 450mm made of Extruded aluminum and Base should be made from Pressure die cast aluminum suitable for Ø60mm OD pipe. Powder coated with epoxypolyester with operational voltage range of 100-277V, power factor > 0.95, THD < 10%, Inbuilt surge protection of 6 KV, Luminaire has Ingress protection of IP65 and IK 06. The luminaire should have minimum lumen output of 3200 lumens delivered @ 3000K with indirect lighting , CRI of >80 . The LEDs used have a life of 60,000hrs L70 B10 burning hrs Lumen maintenance as per L70B10 with SDCM<=3 binning Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161- 03/05/06/07, Surge : IEC 61000-4-5, IES, LM 79, LM 80, & TTC certificates will be provided from in house lab/C34 NABL accredited lab. Certification: CE Certified, Design Patented/Registered, ROHS compliant, BIS Certification for Luminaires & Drivers Make: K-Lite/Unilamp/Regent
Supply of 3.6m decorative circular pole should be made up of circular mild steel pipe (grade YST 210) top to bottom 114mm dia. Wind speed considered in design 50 m/sec in compliance with IS 875 Part 3 : 1987.Pole section welded by certified welders using high end MIG welding processes. PDC aluminium service door 348mm height x 80mm width shall be provided with the company logo embossed on the bottom of the door and safety rope with IP protection rating.The control gear tray is prewired with 2.5 Sq.mm cable, 6A MCB and 32A terminal connectors for loop-in / loop-out arrangement. Any other internal cables and connections shall not be covered in the scope of supply. Mild steel mounting plate 200mm Sq x 12mm thick Steel of grade E250 to IS 2062 : 2011 with 4 elongated holes 38 x 19 to suit M16 x 300mm bolts of grade 4.6. This mounting steel plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation. All dimension and weight are within +/- 5% tolerance. The pole is coated with pure polyester powder coating or epoxy zinc phosphate primer and finished using environmentally stable polyurethane based paint (coating thickness 60-80 microns). The Pole shall be provided with Graphite grey / Anthracite grey / Black as standard colour options. Make: K-Lite/Ligman/LT
Supply,Receiving and fixing in position, effecting proper connections, testing and commissioning of 120W street light LED 3000K, 4000K, 5700K 230-240Vac CRI =80 MacAdam step 3 Dimension : 738 x 289 x 114 mm Optical Distribution : Type III Electronic driver ON/OFF IP rating IP66, Housing and front frame made of pressure die-cast aluminium featuring high strength and anti corrosion. The front frame of the luminaire is hinged for easy open and ease of maintenance. Suitable for mounting on to Ø60 pipe at -15° to +°15 lateral (side entry) and vertical (top mount). Mechanical resistance IK08. Pure polyester powder coated process: Acid treatment & pure polyester powder coating. Clear tempered glass. High light transmittance lens. Lamp fixed position. This luminaire contains built-in LED modules. Minimum luminous efficacy 115lm/w, LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire >60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >85%, power factor >0.9, THD <10%, Surge protection 6KV. The fixtures proposed must have passed LM 79 & LM-80, Reports from NABL laboratory will be submitted post the issuance of LOA to the successful bidder and before the supply of material. Make of LEDs -LEDs of CREE / LUMINOUS / OSRAM / SEOUL / SAMSUNG/LUMILED /NICHIA/CITIZEN. CE & BIS Certified. Make: K-Lite- Model Waco/Unilamp/Ligman existing 9 Mtr pole as per specifications,complete in all repects including nipple for fixing of Light fixture on pole.
Supply installation testing & commisioning of of Static White 3000K/4000K/6000K sports/facade /flood light luminaire made up Extruded aluminium housing and module with excellent thermal management heat sink & Mounting bracket made of CRCA sheet (3mm thickness) with polycarbonate optical cover should have minimum Dimension of 342 x 135 x 245mm, Must have option of antiglare visor. Power consumption should be between 120W at steady state full intensity luminaire, the luminous flux of the luminaire is upto 13500 lm for 6000K BEAM - 12°/25°/40/60. The ingress protection is IP67 and impact resistance of IK08. The luminaire is integrated with high power module with CRI≥70, SDCM≤3. The luminaire should contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire L70B10 >84,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >90%, Power factor >0.95, THD <7.8%, Surge protection 6KV. The driver input voltage 240Vac at 50-60Hz, operating voltage of 100-277Vac.Adequate heat sink with proper thermal management shall be provided. The fixtures proposed must have passed LM 79 & LM-80, Reports from NABL laboratory will be submitted post the issuance of LOA to the successful bidder and before the supply of material. Make of LEDs -LEDs of CREE / LUMINOUS / OSRAM / SEOUL / SAMSUNG/LUMILED /NICHIA/CITIZEN. CE & BIS Certified. Make: K-Lite/Unilamp/Ligman
Supply installation testing & commissioning of bollard light made up of Extruded aluminum bottom pipe (grade 6063 with test certificate) Ø166 x 3mm thickness & die-cast aluminum top cover, SS fasteners. Pre treated silicone gaskets. Die-cast aluminum mounting plate Ø167 x 4mm thick with 4 elongated holes 20 x 14 to suit M12 bolts at PCD 110 with pure polyester powder coating. This mounting plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation. Hot dip galvanized foundation bolt. Should have minimum Dimension of Ø166 x 975mm, Clear polycarbonate diffuser with controlled downward light emission. Lamp at fixed position. Power consumption should be between 14W to 16W at steady state full intensity luminaire, the minimum luminous flux of the luminaire should be 900 lm for 3000K with 360° symmetric distribution. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C o +50°C. Driver efficiency >87%, power factor >0.95, THD <8.2%, Surge protection 3KV. The ingress protection is IP65 and impact resistance of IK08. The driver input voltage 240Vac at 50-60Hz, operating voltage of 100-277Vac. Adequate heat sink with proper thermal management shall be provided. The fixtures proposed must have passed LM 79 & LM-80, Reports from NABL laboratory will be submitted post the issuance of LOA to the successful bidder and before the supply of material. Make of LEDs -LEDs of CREE / LUMINOUS / OSRAM / SEOUL / SAMSUNG/LUMILED /NICHIA/CITIZEN. CE & BIS Certified. Make: K-Lite-Model KL-5565/Unilamp/Ligman
Supply, Installation & Commissioning of Solar PV stand alone Street Lighting System comprising of two 37 Wp / one 74 Wp SPV module, one 12 V, 75 Ah Tubular Plate sealed maintenance free VRLA Gel Battery, one luminaries with inbuilt inverter, dusk to dawn circuit for automatic switching on & off at dusk & dawn and 24 W LED Light, pole, one charge-regulator, module mounting structure, Pole mounted Battery box, cables and other fittings along with 5 (five) years guarantee / warranty period (25 years for SPV Module).
Supply, installation Testing including civil foundation work & commissioning of fixed type high mast lighting tower (16 mtr.) with 8 Nos. 300 watt LED flood light fittings for outdoor lighting application.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Providing and Fixing ceremonial stones for Inauguration and Foundation including cost of Plates of black Granite etched and painted as per the directions of Engineer-in-Charge, construction of Padestal in Brickwork with painting and plastering complete, curtain etc complete job Stones for inauguration and foundation
NEW HI TECH WORKS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.47 MB
BOQ_539574.xls
BOQ • 0.60 MB
Drawings.pdf
Other Document • 31.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .