Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹77.0 LAccepted-AOC 1 3 183 40 46 PLOT NO 36 VAIKUNTHA SAI NAGAR NEW BAKARAM GANDHI NAGAR HYDERABAD TELANGANA 500080 | HYDERABAD | TELANGANA | 500080 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹87.0 L+₹10.0 L (13.0%)Rejected-Finance PRAGATHI PRIDE APARTMENT 3 4 520 FLAT NO 203 BARKATPURA HYDERABAD 500 027 | HYDERABAD | TELANGANA | 500027 | L2 | Rejected-Finance rejected | |
| 3 | L3₹87.6 L+₹10.6 L (13.8%)Rejected-Finance ELECTRICAL ENGINEERING CONTRACTORS D NO 13 186 1 PLOT NO 58 BDL COLONY BADANGPET POST BALAPUR MDL HYDERABAD 500 112 | HYDERABAD | TELANGANA | 500112 | L3 | Rejected-Finance rejected | |
| 4 | L4₹91.3 L+₹14.3 L (18.6%)Rejected-Finance PLOT NO 112 SHAILI GARDENIA YAPRAL RANGAREDDI TELANGANA 500087 | MEDCHAL MALKAJGIRI | TELANGANA | 500087 | L4 | Rejected-Finance rejected | |
| 5 | L5₹92.3 L+₹15.4 L (20.0%)Rejected-Finance | L5 | Rejected-Finance rejected |
Tender Value
Refer Docs
EMD Value
₹2.4 L
Closing Date
4 Aug 2020, 3:00 pmClosed
CCE(RND) SOUTH
PB No. 1569 Akbar Road Secunderabad -03
OPERATION AND MAINTENANCE OF ENM, WATER SUPPLY, FIRE FIGHTING,FIRE ALARM INSTALLATIONS AT CIC COMPLEX, DSST, TPMC, CDA (RND), INTEGRATION WEAPON SYSTEM, NANO, QRSAM, ATCLS, CANISTER, SPRITE, 50 TON TEST BED AT DRDO LABS ASL, RCI (OUTSIDE), DRDL, DMRL
2020_DRDO_571415_1
83576/ENM/ONM/LABS/CON
Limited
Support/Maintenance Service
Item Rate
330 days
Hyderabad
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Yes
CCE(RND) SECUNDERABAD
₹2.4 L
Yes
15 Sept 2020
15 Jul 2020
6 Aug 2020
15 Jul 2020
4 Aug 2020
21 Jul 2020
Amount
CIC COMPLEX, MH,SH & NDT CPDC ASL
Manning & Operation for the following, as per detailed scope of work indicated a Annexures-II-VI on all days excluding sundays and holidays from 9.00 am to 5.30 pm
DG Sets with all related Accessories of Various Capacities mentined in Annexure -II (Inventory Of Installations).
SubStations (External Electrifications) including Area lighting mentined in Annexure -II (Inventory of Installations).
Intenal Electrifications mentined in Annexure -II (Inventory of Installations).
Annual Maintenance Contract for the following as per detailed scope of work indicated a Annexures-II-VI
Fire Alarm Systems
Fire Fighting Systems
Same as mentioned in above but in additional hours
MRSAM STORAGE
Manning & Operation for the following, as per detailed scope of work indicated a Annexures-II-VI on all days in a week including sundays and holidays for 03 (Three) Shift
DG Sets with all related Accessories of Various Capacities mentined in Annexure -II (Inventory Of Installations).
SubStations (External Electrifications) including Area lighting mentined in Annexure -II (Inventory of Installations).
Intenal Electrifications mentined in Annexure -II (Inventory of Installations).
Annual Maintenance Contract for the following as per detailed scope of work indicated a Annexures-II-VI
Fire Alarm Systems
Fire Fighting Systems
KAUTILYA (DSST)
Manning & Operation for the following, as per detailed scope of work indicated a Annexures-II-VI on all days in a week including sundays and holidays for 03 (Three) Shift
DG Sets with all related Accessories of Various Capacities mentined in Annexure -II (Inventory Of Installations).
SubStations (External Electrifications) including Area lighting mentined in Annexure -II (Inventory of Installations).
Intenal Electrifications mentined in Annexure -II (Inventory of Installations).
Annual Maintenance Contract for the following as per detailed scope of work indicated a Annexures-II-VI
Fire Alarm Systems
Fire Fighting Systems
Technical Management Centre, CDA(R&D), IWS, Seminar Hall,
Operation of External/Internal power supply, DG Set, Area lighting,Water Supply System, , as per detailed scope of work indicated a Annexures-I-VI on all days excluding sundays and holidays from 9.00 am to 5.30 pm
DG Sets with all related Accessories of Various Capacities mentined in Annexure -II (Inventory Of Installations).
SubStations (External Electrifications) including Area lighting mentined in Annexure -II (Inventory of Installations).
Intenal Electrifications mentined in Annexure -II (Inventory of Installations).
Annual Maintenance Contract for the following as per detailed scope of work indicated a Annexures-II-VI
Fire Alarm Systems
Fire Fighting Systems
Same as mentioned in above but in additional hours
Operation of External/Internal power supply, Area lighting,Water Supply System, , as per detailed scope of work indicated a Annexures-I-VI on all days excluding sundays and holidays from 9.00 am to 5.30 pm
DG Sets with all related Accessories of Various Capacities mentined in Annexure -II (Inventory Of Installations).
SubStations (External Electrifications) including Area lighting mentined in Annexure -II (Inventory of Installations).
Intenal Electrifications mentined in Annexure -II (Inventory of Installations).
Annual Maintenance Contract for the following as per detailed scope of work indicated a Annexures-II-VI
Fire Alarm Systems
Fire Fighting Systems
Same as mentioned in above but in additional hours
QRSAM, ATCLS, CANISTER,SPRITE, 50 T TEST BED.
Operation of External/Internal power supply, Area lighting,Water Supply System, , as per detailed scope of work indicated a Annexures-I-VI on all days excluding sundays and holidays from 9.00 am to 5.30 pm
DG Sets with all related Accessories of Various Capacities mentined in Annexure -II (Inventory Of Installations).
SubStations (External Electrifications) including Area lighting mentined in Annexure -II (Inventory of Installations).
Intenal Electrifications mentined in Annexure -II (Inventory of Installations).
Annual Maintenance Contract for the following as per detailed scope of work indicated a Annexures-II-VI
Fire Alarm Systems
Fire Fighting Systems
Same as mentioned in above but in additional hours
Special servicing by OEM including cost of standard replaceable with all required accessories etc complete for the following installations.
D Check of 750 KVA DG Set (DSST)
D Check of 200 KVA DG Set (CIC)
B Check of 500 KVA DG Set (IWS), (NaNo), (ATCLS)
B Check of 250 KVA DG Set (Seminar Hall)
B Check of 100 KVA DG Set (NANO)
B Check of 160 KVA DG Set (MRSAM Storage)
Transformer Oil Filteration for the following as per standard with Authorised agency duly approved by the Dept including BDV test Before and After Oil filteration
Oil filteration of 1250 KVA Transformers (Manufacturing Hangar)
Oil filteration of 1000 KVA Transformers (CIC) & (DSST)
Oil filteration of 500 KVA Transformers (IWS & ATCLS)
Oil filteration of 250 KVA Transformers(Seminar hall)
Oil filteration of 315 KVA Transformers(CRMC)
Oil filteration of 160 KVA Transformers(CDA(R&D))
Oil filteration of 100 KVA Transformers(Sprite)
Oil filteration of 315 KVA Transformers(TPMC)
Supply of EXTRA TRANSFORMER OIL for Top up
Transporation of Diesel from petrol Pump to respective work site (Diesel will Supplied By Dept)
Supply of following Consumables and Spares as per the direction of Engineer icharge
Silica Gel
1 / 2 Module Surface Box
3 Module Surface Box
4Module Surface Box
6 Module Surface Box
8 Module Surface Box
1 Module Front Plate
2 Module Front Plate
3 Module Front Plate
4 Module Front Plate
6 Module Front Plate
8 Module Front Plate
16A Switches
16A Sockets
6A Switches
6A Sockets
100W for step regulator
40A, 4P, RCCB
63A, 4P, RCCB
40A/ RCBO, 100MA, 4P
63A/RCBO, 100MA,4P
6-32A DP MCB
6-32A TP MCB
6-32A SP MCB
Philips : PLS11W/865/2PIN
Philips : PLC18W/865/4P
Philips 2X36W CFL Electronic Ballast
Philips 28W T5 LAMP
Philips 11MFD Capacitor
Philips : HPSV Lamp 70W Tubular
Philips : 20MFD Capacitor
SN58 Ignitor for 70-400HPSV Lamp
Philips: BSN70 M261 HPSV Ballast
Philips 14W 2feet Tube light
Philips 4 x 14W Elec. Ballast
Philips 20W LED Tube
Philips 51W LED Drivers
Philips 35W LED Driver
Philips EBE 2X36W Electronic Choke
Philips PLL/36W CFL Lamp
11W choke
28W choke
2 x 28W choke
40W tubelight
BSN250M261 HPSV Ballast
33MFD Capacitor
36W 4Pin PLS lamps
HPSV Lamp 150W Tubular
BSN150 OC HPSV Ballast
HPSV Lamp 250W Tubular
2x 16 W Industrial Type LED LightFixtures(Philips:(TMC 501 P2XT-LED 16 W Master LED Tube) or Equilent
12 W LED surface Mounted LightFixtures(Bajaj: BGCML 12 01 WW) or Equilent
15 W 5000K Recess mounted LED down lighter LightFixtures(philips : BBS 175 1XD LED=5000 PSU WH) or Equilent
40 W Recess mounted LED lighter LightFixtures(philips : RC3808 LED 30-6500 PSE OD WH) or Equilent
10 W LED Bulk Head lighter LightFixtures(philips : WT202W LED 65 CW PSU S1 PC) or Equilent
1.5 Sqmm FRLS Copper Wire
2.5 Sqmm FRLS COpper Wire
4 Sq mm FRLS Copper Wire
6 Sq mm FRLS Copper Wire
25mm Casing Caping
Sintex Pole Junction Box
Rewinding of 1200mm Sweep Ceiling Fan
Rewinding of 305mm Dia Exhaust Fan
Rewinding of 380mm Dia Exhaust Fan
Philips 9W LED Driver
Philips 16W LED Driver
Philips 10W LED light fixture
Philips 22W LED light fixture
Philips 70W LED Driver
Philips 90W LED Driver
Philips 165W LED Driver
Short body taps
Long body/Angle taps
Spindle of long body Tap
Angle Cock/ taps
Urinal Hose pipe
Flush Hose Pipe
Float valve for Water tank
Float valve for EWC/IWC
MCCB 36 Amp three pole
MCCB 250 Amp Four pole
contactor MNX 32
MCCB 100 Amp
MCB 6 Amp
2 feet LED light
UV light LED 2 feet
LBRP60CL22CD 60 W
HRC FUSE (HF14X51) 32 AMP
MNX09 Contactor
MCB 10 Amp SP
SMPS 12 volt output 1.3 Amp (MES-15-12)
Heating coil 5 KW 230 Volt AC (A0116)
Smoke Detectors
Heat Detectors
Response Indicators,
Sounders,(Hooter)
control module,
Duct Detectors
Exit signage, ,
Fault Isolators Module
Sirens
Battery of 12 Volt
8 Way Wago/ Phonix Terminal Connector
Whether Proof Manual Call Point
Monitor Relay Module
Beam Master with Emitter & Reciver
CHARAN ELECTRICALS
SATYAM ELECTRICALS
Millennium Power and Security Solutions
SHASTAS
Eldi Techs
Shri Sai Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .