Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.3 CrAdmitted-Finance SCHINDLER HOUSE MAIN STREET HIRANANDANI GARDENS POWAI MUMBAI 400076 MAHARASHTRA INDIA | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400076 | +0.00% | ₹1.3 Cr | L1 | Admitted-Finance |
Updated dates
Tender Value
₹1.3 Cr
EMD Value
₹2.5 L
Closing Date
21 May 2026, 3:00 pmClosed
EE,ELD-4,DDA
EE,ELD-4,DDA
Comprehensive Maintenance of lifts installed at Pocket-11 at Sector G7/G8, Narela.
2026_DDA_907160_1
09/EE/ELD-4/DDA/2026-27
Open Tender
Electrical Works
365 days
NARELA
Please refer Tender documents.
11 documents required · 11 mandatory
₹0
₹2.5 L
05/05/2026 at 11.00 A.M. in the chamber of SE(E)/
4 Jun 2026
2 May 2026
22 May 2026
2 May 2026
21 May 2026
6 May 2026
5 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Annual comprehensive maintenance of 53 Nos. (16-Passengers), Schindler make lifts with 13 landing/openings with ARD at rated speed of 1.75 mtr./ second which includes routine, preventive and break down maintenance for a period of one year including repair / replacement of all worn out items, accessories and control equipments, defective parts with minimum down time as per inventory, terms & conditions enclosed etc. complete as required. | - | Month | 7,33,469 | - | BI01010001010000000000000515BI0100001113 |
| 2 | Annual comprehensive maintenance of 3 Nos. (16-Passengers), Schindler make lifts with 12 landing/openings with ARD at rated speed of 1.75 mtr./ second which includes routine, preventive and break down maintenance for a period of one year including repair / replacement of all worn out items, accessories and control equipments, defective parts with minimum down time as per inventory, terms & conditions enclosed etc. complete as required. | - | Month | 40,229 | - | BI01010001010000000000000515BI0100001114 |
| 3 | Annual comprehensive maintenance of 01 Nos. (13-Passengers), Schindler make lifts with 12 landing/openings with ARD at rated speed of 1.75 mtr./ second which includes routine, preventive and break down maintenance for a period of one year including repair / replacement of all worn out items, accessories and control equipments, defective parts with minimum down time as per inventory, terms & conditions enclosed etc. complete as required. | - | Per Month | 12,920 | - | BI01010001010000000000000515BI0100001115 |
| 4 | Annual comprehensive maintenance of 1 Nos. (13-Passengers), Schindler make lifts with 13 landing/openings with ARD at rated speed of 1.75 mtr./ second which includes routine, preventive and break down maintenance for a period of one year including repair / replacement of all worn out items, accessories and control equipments, defective parts with minimum down time as per inventory, terms & conditions enclosed etc. complete as required. | - | Month | 13,325 | - | BI01010001010000000000000515BI0100001116 |
| 5 | supplying & replacement of following Non Working, damaged & missing Lift parts for lift equipment no 10908820 & 10908823 to keep lifts functional:
Landing door panel Qty 2.00
Kit IDN Safety gear act. m. TL SA-GED1X Qty 2.00
PCBA CANCP 211.Q sus.57618362 Qty 2.00
PowSup_230VAC_26VDC(HF150W SDR 26 G) Qty 2.00
PCBA COPKGL 51.Q Qty 8.00
PCBA COPKGL 31.Q Qty 8.00
Module VVVF5+ drive T2L/C2 EU/NA Qty 2.00
SDIC53.Q anti-sulphur resistors Qty 2.00
Batt_VRLA_12V_12Ah_HD_F2_40C_2K Qty 4.00
Wiring LDU-VF 6mm2 w. AES IND Bionic 5.4 Qty 4.00
Inverter 24VDC-230VAC 800W Qty 2.00
COP GS 120-IN 9/6 M without VCA Qty 2.00
Set motor VVVF Qty 2.00
Travelling Base Cable HQ <= 60 CCL Qty 130.00
LOP GS 100 M-1WSF ASSEMBLED (COMPLETE) Qty 20.00 | - | JOB | 9,76,484 | - | BI01010001010000000000000515BI0100001117 |
| 6 | supplying & replacement of following Non Working, damaged & missing Lift parts for lift equipment no 10908826 & 10908828 to keep lifts functional:
LOP cable 1.5mm2, L=3600mm Qty.20.00 Nos.
SKS extension Bionic 5 L=3800 Qty 10.00
IND Intercom (3-way) Harness cable Qty 6.00
CAT 6 flat Travelling cable Qty 120.00
PCBA SCPU1.Q + SW 9.85,anti-sulphur res. Qty 2.00
SDIC53.Q anti-sulphur resistors Qty 2.00
Module VVVF5+ drive T2L/C2 EU/NA Qty 2.00
Set motor VVVF Qty 2.00
PCBA CANCP 211.Q sus.57618362 Qty 2.00
Cross Flow Fan / ULF2-1042CS III Qty 2.00
Landing door panel Qty 2.00
2.5 sq. mm 4 core cu cable for SPD to JH Qty 4.00
2.5 sq. mm 2 core cu cable for TAS I/P Qty 4.00
Inverter 24VDC-230VAC 800W Qty 2.00
Batt_VRLA_12V_12Ah_HD_F2_40C_2K Qty 4.00
PowSup_230VAC_26VDC(HF150W SDR 26 G) Qty 2.00
Bi- Stable magnet switch with harness Qty 4.00
10 sq. mm 4 core cu cable for SPD to JH Qty 4.00
1 sq. mm 2 core cu cable for SPD alarm Qty 4.00
Kit LSC154 DO V15/FEC T2L/T2R Qty 2.00
Travelling Base Cable HQ <= 60 CCL Qty 120.00
LOP GS 100 M-1WSF ASSEMBLED (COMPLETE) Qty 20.00
COP GS 120-IN 9/6 M without VCA Qty 2.00 | - | JOB | 10,52,614 | - | BI01010001010000000000000515BI0100001118 |
| 7 | supplying & replacement of following Non Working, damaged & missing Lift parts for lift equipment no 10908876 & 10908877 to keep lifts functional:
Sup. Mod. TL IND 32A w. AES BIC5 Qty 2.00
Base Module TL IND with AES Bionic 5.4 Qty 2.00
LOP cable 1.5mm2, L=3600mm Qty 2.00
PCBA CANCP 211.Q sus.57618362 Qty 2.00
IND Intercom (3-way) Harness cable Qty 6.00
SKS extension Bionic 5 L=3800 Qty 10.00
CAT 6 flat Travelling cable Qty 120.00
SDIC53.Q anti-sulphur resistors Qty 2.00
Module VVVF5+ drive T2L/C2 EU/NA Qty 2.00
Set motor VVVF Qty 2.00
Cross Flow Fan / ULF2-1042CS III Qty 2.00
2.5 sq. mm 4 core cu cable for SPD to JH Qty 8.00 Qty
2.5 sq. mm 4 core cu cable for SPD to JH Qty 8.00
2.5 sq. mm 2 core cu cable for TAS I/P Qty 8.00
Batt_VRLA_12V_12Ah_HD_F2_40C_2K Qty 4.00
Bi- Stable magnet switch with harness Qty 4.00
10 sq. mm 4 core cu cable for SPD to JH Qty 8.00
COP GS 120-IN 9/6 M without VCA Qty 2.00
Travelling Base Cable HQ <= 60 CCL Qty 130.00
Kit LSC154 DO V15/FEC T2L/T2R Qty 2.00
PCBA SCPU1.Q + SW 9.85,anti-sulphur res. Qty 2.00 | - | JOB | 10,44,627 | - | BI01010001010000000000000515BI0100001119 |
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.84 MB
BOQ_953497.xls
BOQ • 0.28 MB
NIT09.pdf
Tender Documents • 1.82 MB
Download all tender documents and submit your bid